THERMAX LIMITED

SUSTAINABLE SOLUTIONS IN THE FIELD OF ENERGY AND ENVIRONMENT

DMF - DESIGN SUMMARY

DUAL MEDIA FILTER


PARAMETERS VALUE UOM
Outlet TSS <5 ppm
Standard Model VERSADMF07
Diameter 1200 mm
HOS 1500 mm
Frontal line size 65 NB
Shell thickness 4 mm
Dish thickness 5 mm
Vessel MOC MS
Piping MOC MS
Operating Pressure 3.5 Kg/cm2
Rubber Lining NA mm
Individual
Frontal Valve Valve
2
s VERSADM F UNIT DETAIL: — VERSAACF UNIT DETAIL: — (CARBON —IV—450)
NOT SCALE THE DRAWING

IN DOUBT PLEASE ASK.

MODEL NAME DIA ’D’ H.O. S PPE NB PIPE NB SHELL DISH MOC MODEL NAME DIA ‘D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
DIMENSIO NS ARE IN

A 'D1' 'D2' THK.mm THK.mm 'D1 ’ 'D2’ THK.mm THK.mm A


VERSADM F/ACF/IRF/OC VERSADMF01 800 1500 50 20 4 5 MS VERSAACF01 800 1500 50 20 4 5 MS
VERSADMF02 900 1500 50 20 4 5 MS VERSAACF02 900 1500 50 20 4 5 MS
VERSADMF03 900 1500 65 20 4 5 MS VERSAACF03 1000 1500 50 20 4 5 MS
VERSADMF04 1000 1500 50 20 4 5 MS VERSAACF04 1100 1500 65 20 4 5 MS
VERSADMFOS 1000 1500 65 20 4 5 MS VERSAACFOS 1200 1500 65 20 4 5 MS
VERSAD r06 100 1500 65 20 4 5 MS VERSAACF06 1300 1500 65 52 4 5 MS
VERSAD r0y 200 1500 65 20 4 5 MS VERSAACF07 1400 1500 65 52 4 6 MS
VERSAD r0g 200 1500 80 20 4 5 MS VERSAACF08 1500 1500 80 52 5 6 MS
VERSAD r09 300 1500 65 32 4 5 MS VERSAACF09 1600 1500 80 52 5 6 MS
VERSAD r 0 300 1500 80 52 4 6 MS VERSAACF10 1700 1500 100 32 5 6 MS
PI VERSAD r i 400 1500 65 52 4 6 MS VERSAACF11 1800 1500 100 32 5 6 MS
VERSAD r 2 400 1500 80 52 4 6 MS VERSAACF12 1900 1500 100 32 6 8 MS
V41
V1 V4 VERSADMF13 1400 1500 100 52 5 6 MS VERSAACF13 2000 2000 100 32 6 8 MS
D1NB D1 VERSADMF14 1500 1500 80 32 5 6 MS VERSAACF14 2100 2000 100 40 6 8 MS
VERSADMF15 1500 1500 100 32 5 6 MS VERSAACF15 2200 2000 125 40 6 8 MS
V50 VERSADMF16 1600 1500 80 32 5 6 MS VERSAACF16 2300 2000 125 40 6 10 MS
D1 VERSADMF17 1600 1500 100 52 5 6 MS VERsAAcr17 2400 2000 150 40 6 10 MS
VERSADMF18 1700 1500 100 52 5 6 MS
VERSADMF19 1800 J500 100 52 5 6 MS
D1 V2 V6 D1 VERSADMF20 1800 1500 125 52 5 6 MS VERSAIRF UNIT DETAIL: —
VERSADMF21 1900 1500 100 32 6 8 MS
V12

VERSADMF22 1900 1500 125 32 6 8 MS


MODEL NAME DIA ’D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
V50 VERSADMF23 2000 2000 100 40 6 8 MS 'D1 ’ 'D2’ THK.mm THK.mm
VERSADMF24 2000 2000 125 40 6 8 MS
VERSAIRF01 800 1500 50 20 4 5 MS
PI VERSAD r25 2100 2000 100 40 6 8 MS
VERSAIRF02 900 1500 50 20 4 5 MS
VERSAD r26 2100 2000 125 40 6 8 MS
VERSAIRFOS 1000 1500 50 20 4 5 MS
VERSAD r2y 2200 2000 125 40 6 8 MS
VERSAIRF04 1100 1500 65 20 4 5 MS
VERSAD r2g 2200 2000 150 40 6 8 MS VERSAIRFOS 1200 1500 65 20 4 5 MS
RETD RNED 0 N

WRITTEN CONSENT.

VERSAD r29 2300 2000 125 40 6 8 MS VERSAIRF06 1300 1500 65 32 4 5 MS


VERSAD r30 2300 2000 150 40 6 8 MS VERSAIRF07 1400 1500 65 32 4 6 MS
g E VERSAD r3i 2400 2000 125 50 6 10 MS VERSAIRF08 1500 1500 80 32 5 6 MS E
USED, COPIED, REPRODUCED OR

VERSAD r32 2400 2000 150 50 6 10 MS VERSAIRF09 1600 1500 80 32 5 6 MS


CONNECTION WITH

NOTE — : VERSAIRF10 1700 1500 100 32 5 6 MS


VERSAIRF11 1800 1500 100 32 5 6 MS
1 . VERSA Vessel s a re a I so ava i I a bI e in MSRL
MUST

VERSAOC U NIT DETAI L: — VERSAIRF12 1900 1500 100 32 6 8 MS


MOC. The Ru bber Linin g of thic k ness 3 mm VERSAIRF13 2000 2000 100 40 6 8 MS
MODEL NAME DIA ‘D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
INTERESTS WITHOUT

wilI be pro vided to vess el. VERSAIRF14 2100 2000 100 40 6 8 MS


'D1 'D2’ THK.mm THK.mm VERSAIRF15 2200 2000 125 40 6 8 MS
THIS DRAWING lS THE PROPERTY OF THERMAX LIMITED

VERSA0C01 800 1500 65 20 4 5 MS VERSAIRF16 2300 2000 125 40 6 10 MS


IS SUBMITTED AS CONFIDENTIAL INFORMATION

VERSA0C02 900 1500 80 20 4 5 MS VERSAIRF17 2400 2000 125 50 6 10 MS


VALVE LEGEND VERSA0C03 1000 1500 100 32 4 5 MS
VERSA0C04 1100 1500 100 52 4 5 MS INSTRUMENT DETAI LS: —
VERSAOCOS 1200 1500 100 52 4 5 MS
SHOULD NOT

SR.
VERSA0C06 1300 1500 125 52 4 5 MS NO. MARK DESCRIPTION ros. orr. MAKE
° 1 PI PRESSURE INDICATOR 2 Nos. EACH M 0 DEL THERMAX APPD.
VERSA0C07 1400 1500 125 52 4 6 MS
WAY DETREME NTAL TO

VERSA0C08 1500 1500 125 40 5 6 MS


VERSA0C09 1600 1500 150 40 5 6 MS
CONTRACT.

CAD FILE NO. CODE NO. CLIENT: — PROJ ECT: —


APPD. BY A R
CO NSU LTANT: — TITLE: — P& I DIAGRAM FOR
VERSA FILTERS
CHKD. BY US P
THERMAX LIMITED (DM F/ACF/IRF/OC)
TENDER, ORDER
00 14.03.18 ISSUED FOR INFORMATIO N ABJ US P AR DRAWN BY ABJ WATER A WASTE SOLUTIONS
REQUEST
REV. DRAWN CHKD. APPD. ENVIRONMENT HOUSE, O.C.NO. DRG. NO. SHEET NO. REV. NO.
PLOT NO. 90—92, BG BLOCK,
DATE DESCRIPTION DATE 14.03. 18 SCALE — THERMAX STD/ VDMACIROCW 3B 1 1 0F 1 00

EX HIBITED
NO. BY BY BY M.I.D.C BHOSARI, PUNE—411026.(INDIA)
THERMAX LIMITED
SUSTAINABLE SOLUTIONS IN THE FIELD OF ENERGY AND ENVIRONMENT

IRF - DESIGN SUMMARY

IRON REMOVAL FILTER


PARAMETERS VALUE UOM
Outlet Iron Content <0.03 ppm
Standard Model VERSA IRF05
Diameter 1200 mm
HOS 1500 mm
Frontal line size 65 NB
Shell thickness 4 mm
Dish thickness 5 mm
Vessel MOC MS
Piping MOC MS
Operating Pressure 3.5 Kg/cm2
Rubber Lining NA mm
Individual
Frontal Valve Valve
2
s VERSADM F UNIT DETAIL: — VERSAACF UNIT DETAIL: — (CARBON —IV—450)
NOT SCALE THE DRAWING

IN DOUBT PLEASE ASK.

MODEL NAME DIA ’D’ H.O. S PPE NB PIPE NB SHELL DISH MOC MODEL NAME DIA ‘D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
DIMENSIO NS ARE IN

A 'D1' 'D2' THK.mm THK.mm 'D1 ’ 'D2’ THK.mm THK.mm A


VERSADM F/ACF/IRF/OC VERSADMF01 800 1500 50 20 4 5 MS VERSAACF01 800 1500 50 20 4 5 MS
VERSADMF02 900 1500 50 20 4 5 MS VERSAACF02 900 1500 50 20 4 5 MS
VERSADMF03 900 1500 65 20 4 5 MS VERSAACF03 1000 1500 50 20 4 5 MS
VERSADMF04 1000 1500 50 20 4 5 MS VERSAACF04 1100 1500 65 20 4 5 MS
VERSADMFOS 1000 1500 65 20 4 5 MS VERSAACFOS 1200 1500 65 20 4 5 MS
VERSAD r06 100 1500 65 20 4 5 MS VERSAACF06 1300 1500 65 52 4 5 MS
VERSAD r0y 200 1500 65 20 4 5 MS VERSAACF07 1400 1500 65 52 4 6 MS
VERSAD r0g 200 1500 80 20 4 5 MS VERSAACF08 1500 1500 80 52 5 6 MS
VERSAD r09 300 1500 65 32 4 5 MS VERSAACF09 1600 1500 80 52 5 6 MS
VERSAD r 0 300 1500 80 52 4 6 MS VERSAACF10 1700 1500 100 32 5 6 MS
PI VERSAD r i 400 1500 65 52 4 6 MS VERSAACF11 1800 1500 100 32 5 6 MS
VERSAD r 2 400 1500 80 52 4 6 MS VERSAACF12 1900 1500 100 32 6 8 MS
V41
V1 V4 VERSADMF13 1400 1500 100 52 5 6 MS VERSAACF13 2000 2000 100 32 6 8 MS
D1NB D1 VERSADMF14 1500 1500 80 32 5 6 MS VERSAACF14 2100 2000 100 40 6 8 MS
VERSADMF15 1500 1500 100 32 5 6 MS VERSAACF15 2200 2000 125 40 6 8 MS
V50 VERSADMF16 1600 1500 80 32 5 6 MS VERSAACF16 2300 2000 125 40 6 10 MS
D1 VERSADMF17 1600 1500 100 52 5 6 MS VERsAAcr17 2400 2000 150 40 6 10 MS
VERSADMF18 1700 1500 100 52 5 6 MS
VERSADMF19 1800 J500 100 52 5 6 MS
D1 V2 V6 D1 VERSADMF20 1800 1500 125 52 5 6 MS VERSAIRF UNIT DETAIL: —
VERSADMF21 1900 1500 100 32 6 8 MS
V12

VERSADMF22 1900 1500 125 32 6 8 MS


MODEL NAME DIA ’D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
V50 VERSADMF23 2000 2000 100 40 6 8 MS 'D1 ’ 'D2’ THK.mm THK.mm
VERSADMF24 2000 2000 125 40 6 8 MS
VERSAIRF01 800 1500 50 20 4 5 MS
PI VERSAD r25 2100 2000 100 40 6 8 MS
VERSAIRF02 900 1500 50 20 4 5 MS
VERSAD r26 2100 2000 125 40 6 8 MS
VERSAIRFOS 1000 1500 50 20 4 5 MS
VERSAD r2y 2200 2000 125 40 6 8 MS
VERSAIRF04 1100 1500 65 20 4 5 MS
VERSAD r2g 2200 2000 150 40 6 8 MS
VERSAIRFOS 1200 1500 65 20 4 5 MS
RETD RNED 0 N

WRITTEN CONSENT.

VERSAD r29 2300 2000 125 40 6 8 MS


VERSAIRF06 1300 1500 65 32 4 5 MS
VERSAD r30 2300 2000 150 40 6 8 MS
VERSAIRF07 1400 1500 65 32 4 6 MS
g E VERSAD r3i 2400 2000 125 50 6 10 MS
VERSAIRF08 1500 1500 80 32 5 6 MS E
USED, COPIED, REPRODUCED OR

VERSAD r32 2400 2000 150 50 6 10 MS VERSAIRF09 1600 1500 80 32 5 6 MS


CONNECTION WITH

NOTE — : VERSAIRF10 1700 1500 100 32 5 6 MS


VERSAIRF11 1800 1500 100 32 5 6 MS
1 . VERSA Vessel s a re a I so ava i I a bI e in MSRL
MUST

VERSAOC U NIT DETAI L: — VERSAIRF12 1900 1500 100 32 6 8 MS


MOC. The Ru bber Linin g of thic k ness 3 mm VERSAIRF13 2000 2000 100 40 6 8 MS
MODEL NAME DIA ‘D’ H.0.S PIPE NB PIPE NB SHELL DISH MOC
INTERESTS WITHOUT

wilI be pro vided to vess el. VERSAIRF14 2100 2000 100 40 6 8 MS


'D1 'D2’ THK.mm THK.mm VERSAIRF15 2200 2000 125 40 6 8 MS
THIS DRAWING lS THE PROPERTY OF THERMAX LIMITED

VERSA0C01 800 1500 65 20 4 5 MS VERSAIRF16 2300 2000 125 40 6 10 MS


VALVE LEGEND
IS SUBMITTED AS CONFIDENTIAL INFORMATION

VERSA0C02 900 1500 80 20 4 5 MS VERSAIRF17 2400 2000 125 50 6 10 MS


VERSA0C03 1000 1500 100 32 4 5 MS
VERSA0C04 1100 1500 100 52 4 5 MS INSTRUMENT DETAI LS: —
VERSAOCOS 1200 1500 100 52 4 5 MS
SHOULD NOT

SR.
VERSA0C06 1300 1500 125 52 4 5 MS NO. MARK DESCRIPTION ros. orr. MAKE
° 1 PI PRESSURE INDICATOR 2 Nos. EACH M 0 DEL THERMAX APPD.
VERSA0C07 1400 1500 125 52 4 6 MS
WAY DETREME NTAL TO

VERSA0C08 1500 1500 125 40 5 6 MS


VERSA0C09 1600 1500 150 40 5 6 MS
CONTRACT.

CAD FILE NO. CODE NO. CLIENT: — PROJ ECT: —


APPD. BY A R
CO NSU LTANT: — TITLE: — P& I DIAGRAM FOR
VERSA FILTERS
CHKD. BY US P
THERMAX LIMITED (DM F/ACF/IRF/OC)

TENDER, ORDER
00 14.03.18 ISSUED FOR INFORMATIO N ABJ US P AR DRAWN BY ABJ WATER A WASTE SOLUTIONS

REQUEST
REV. DRAWN CHKD. APPD. ENVIRONMENT HOUSE, O.C.NO. DRG. NO. SHEET NO. REV. NO.
PLOT NO. 90—92, BG BLOCK,
DATE DESCRIPTION DATE 14.03. 18 SCALE — THERMAX STD/ VDMACIROCW 3B 1 1 0F 1 00

X HIBITED
NO. BY BY BY M.I.D.C BHOSARI, PUNE—411026.(INDIA)
A Technical Proposal for E Series RO 2000

Capacity 2000 LPH


Thermax Vision
“To be a globally respected high-performance
organization offering sustainable solutions in
energy and environment”.

Contents
1. Process design basis

2. Process block diagram

3. Scope of Works

4. Termination Points

5. Make of components
1. Process Design Basis
This treatment scheme has been designed to treat the water having following characteristics-

A) Inlet Parameters:

Parameter Units Value


Source -- Borewell
TDS ppm <1500
TSS ppm <10
Turbidity ppm <10
pH -- 6.5 - 7.5
Total Hardness as CaCO3 ppm 400
Total Alkalinity as CaCO3 ppm 350
Chloride as Cl ppm 450
Sulphate as SO4 ppm 150
Silica as SiO2 (Reactive) ppm 20
Silica (Colloidal) ppm NIL
Heavy Metal ppm < 0.1
COD ppm NIL
BOD ppm NIL
SDI ppm <3
Free Chlorine ppm NIL
O&G ppm NIL
Iron ppm <0.1

B) Outlet Parameters:

Parameter Units Value


TDS ppm 100

C) Plant Details:

Parameter Units Value


RO Feed m3/hr 4.0
Permeate m3/hr 2.0
Reject m3/hr 2.0
Recirculation m3/hr 2.8

Reference: WWS/SPG/ RO 2000 Date: 02-06-2022 - 3-


Customer Name: PREMIER STEEL PVT LTD
2. Process Block diagram

4
3. Scope of Works

I. Mechanical
Sr. Item Qty Size/ Motor power MOC
no Capacity (kw)

1 Filter feed pump 1 no. 4.0 m3/hr @ 2.5 1.1 KW CI


bar
2 Self-cleaning filter 1 no. 4.0 m3/hr @ 50 -- Reinforced
micron Polypropylene
3 Anti scalant dosing pump 1 no. 0-6 LPH -- PP
4 Anti scalant dosing pump 1 no. 50 LTR -- LLDPE
3 Cartridge Filter Housing 1 no. 4.0 m3/hr @ 5 -- PP / AEP
and Cartridge micron
4 High pressure pump 1 no. 6.8 m3/hr @ 13.6 4.0 KW SS304
(HPP) bar
5 Pressure tube 2 nos. 1 Element long - -- FRP
300 psi
6 Membrane 2 nos. 8” Diameter -- Polyamide -TFC
7 ICPW 1 no. Suitable -- UPVC

II. Instruments
Sr. no Item Qty Location
1 Pressure Indicator 4 nos. Feed pump discharge, Inlet of pressure tube,
Reject, Outlet of cartridge filter
2 Pressure Switch 1 no. Inlet of HPP
3 Flow Sensor 3 nos. Recirculation, Reject & Permeate line
4 Level Switch 1 no. Treated water tank
5 Conductivity Sensor 1 no. Permeate of RO

III. Electrical
Electrical list
 Cables
o Flexible Copper conductor Power, control & instrumentation cabling as per IS-
1554 are considered with PVC Cable glands and lugs for end termination.
 Starter Panel
o Microprocessor based starter panel; MS powder coated.

5
4. Termination Points

Sr. No. Description Location

1 Raw Water At the inlet of filter feed pump @ flooded suction


2 RO Permeate At the RO skid
3 RO Reject At the RO skid to drain
4 Power supply @ 3 phase At incomer of panel 415 vac ± 10 %, 50 hz, 4 wire
5 Chemicals At each measuring tank

6
5. Make of Components
Sr. Description Make
No
1 Filter Feed Pump
2 Self-Cleaning Filter
3 Cartridge Filter Housing and Cartridge
4 High Pressure Pump
5 Pressure Tube
6 Membrane
All the makes for bought out component use in
7 ICPW
offered RO plant are selected in line with process
8 Pressure Indicator
requirement.
9 Pressure Switch
10 Flow Sensor
11 Level Switch
12 Conductivity Meter
13 Astro Panel
14 Cable

“Copyright © Thermax ltd, all rights reserved


This proposal is a confidential work protected by copyright and trade secret law and neither it nor any of the
information contained therein may be disclosed, used or reproduced in any manner, or for any purpose, except
by written permission from Thermax ltd.”

7
2 5 6 7 8
DRA] RNG.

ASTRO PANEL •• ••
A
PI ” CI
s
DIMENSONS

25 NB
scr 25 NB UPVC 32 NE 5 NI
DOUBT

FS
UPVC UPVC PVC 25
RAW WATER uPvc i
NOT

BY CLIENTS V26 i
IN 25 NB B
V27 uPvc
V50 — — —
RAW WATER
TO DRAIN •
TANK
BY CLIENT V25
ANTISCALENT DOS NG
40 NB TANK FS STORAGE TANK
UPVC BY CUENT —
A STM
TO DRAIN
D UNIT DETAILS:— INSTRUMENT DETAILS:— D
SR. NOS. MK.
NO. DESCRIPTION MARK SIZE / CAPACITY orr. REMARKS NO. DESCRIPTION QTY kIAKE
1 FILTER FEED PUMP FFP 4.0 M/HR e 2 5 KG CM2 THERMAX 2 Pi PRESSUREINDCATOR 4 THERMAX
2 SELF—CLEANING FILTER SCF 4.0 M/HR e 50 MICRONS 1 THERMAX PS PRESSURE SWITCH 1 THERMAX
ON REQUEST IT IS SUBMITTED AS CONFIDENTIAL INFORMATION IN CONNECTION WITH ENQUIRY.

EXHIBITED IN ANY WAY DETREMENTAL TO OUR INTERESTS WITHOUT OUR WRITTEN CONSENT.

3 ANTISCALENT DOSING PUMP FS FLOW SENSOR 3 THERMAX


THIS DRAWING IS THE PROPERTY OF 3’ AER IAX IJB'IIED AND MUST BE RETURNED

PAS 0—4 LPH 1 THERMAX


TENDER, ORDER OR CONTRACT. IT SHOULD NOT BE USED, COPIED, REPRODUCED OR

E ANTISCALENT DOSING TANK TAS CAP.:— 50 LTRS. 1 THERMAX LS LEVEL SWITCHES 1 THERklAX
E
WITH LEVEL SWITCH CI CONDUCTIVITY kIETER 1 THERkIAX
5 CARTRIDGE FILTER CF1 4.0M3/HR e 5 MICRONS 1 PP ASTRO 13 PANEL 1 THERMAX APPD.
6 HIGH PRESSURE PUMP SS30 HPP 6 8 HR 13 6 KG C 2 1 THERMAX
7 PRESSURE TUBES (300 PSI) PT SUITABLE FOR 1 ELEMENT 2 THERMAX APPD.
PLANT DETAILS: —
8 MEMBRANES ME 8"—400 SQ FT 2 THERI\FAX
UNIT TREATMENT
kIARK FLOWS
F F
OUR TERMINATION POINTS:— INLET WATER:— NOS /HR
VALVE LEGEND SIZE FLOW PRESSURE CONN.STD. TDS : 1500 ppm
uAR DESCRIPTION CF1 INLET 4.0
DIAPHRAGM VALVE BALL VALYE NB |g3 /HR Kgs/cm2
BUWERFLY VALVE q@$g y yg
UTLET WATER PERMEATE 2.0
A F-F-P SUCTION 40 4.0 FLOODED SOCKETED
REJECT 2.0
CHECK VALVE B REJECT 2.0 ATM. SOCKETED
SOLENOID VALVE
ATMS TDS 100 ppm RECCIIRRCCU
ULATION 2.8
NEEDLE VALVE C PERMEATE 25 2.0 SOCKETED
MTE VALVE RECOVERY 50%
——————— SCOPE OF CMENT
^^ ^^ ELECTRICAL INTERLOCK
cAD riLE NO. CODE NO . CLIENT:— — 5
02 11.08.21 REVISED AS MARKED ABJ PB J’ CONSULTANT:—
APPD. BY JM
H 01 29.06.21 REVISED AS MARKED ABJ PB JM CHKD. BY PB THERMAX LIMITED
00 22.06.21 ISSUED FOR INFORMATION ABJ PB Jkl DRAWN BY ABJ WATER d‹ WASTE SOLUTIONS
ENVIRONMENT HOUSE,
REV. DRAWN CHKD. APPD. PLOT NO. 90-92, BG BLOCK,
NO. DATE DESCRIPTION DATE 22.06.21 SCALE BTS N.I.D.C BHOSARI, PUNE—411026.(INDIA) THERMAX
2
8
6 PROJ E-2000LPH E2000LPHW3B1 1 OF 1 02
ECT: 7 8
—E
SERIE
S RO
PLANT
T
I
T
L
E
:

P
&
I
D
I
A
G
R
A
M
F
O
R
E
-
2
0
0
0
L
P
H
0.C.NO
.
DRG.N
O.
SHEET
NO.
REV.N
O.
9
SMART DOSING SYSTEM
Free Standing Unit with Top Mounted Dosing Pump
Features :
• Optimized chemical consumption
• MOC : FRP/LLDP
• Minimum maintenance
• Accurate, efficient and safe
• Free standing and compact
• Integrated intelligence feature with auto compensation and auto
calibration
Specification
• Capacity : 6 LPH, 10 LPH and 12 LPH
• Head : 3.5 kg/cm2
• Product type : Liquid Chemicals
• Dosing Method : Digital Dosing
• Tank MOC : FRP / LLDP
Energy | Environment | Chemical www.thermaxglobal.com
• Tank capacity : 100 L
• Pump MOC : PP