Professional Documents
Culture Documents
JVP Raised Access Floor System
JVP Raised Access Floor System
JVP
Raised access floor
Pavimento sopraelevato accessibile
EN
Message From The Founder
During 1997 while seated in an Transforming the idea into a real This first production line became
airport lounge idly passing the product, however, was another a reality in 1998. It was fully
time away, I noticed an matter. It involved the design of automated producing 500 4x4
aluminum soft drinks can. a fully automated production line precision panels per hour.
from start to finish.
My never-ending curiosity Today we produce over 1000
caused me to think about its With the help of fantastic staff, panels per hour using the third
specialist rounded rim joint. after nine months the first generation production line,
I saw there were no sharp production line for the “4x4 while maintaining the same
edges, which might cause panels” was installed in Italy meticulous engagement as in
injury, and that it was a robust close to Venice – the past. We continue to
structure – nice simple idea. my motherland. advance through research and
development.
After a short while, I also Our goal was to utilize the latest
noticed the same joint on the technology while establishing a We are committed to making
cylindrical ducting in the ceiling, safe environment for its advances in quality,
this time in steel. operators. performance and service.
Much later on I found out that Considerable attention was also A simple idea has gone
this joint is called “curling”. given to environmental issues, a long way!
energy savings, consistency of
Applying this curling idea to production output, tolerances
raised access floor panels was and performances.
relatively easy. The Founder
Company concept
Simplicity with efficiency
JVP
Raised access floor
Pavimento sopraelevato accessibile
INDEX
Company Concept ______________________ 1
Performances _________________________ 10
Gretag
Allreal
Zurich
Switzerland
12000 m2
C4TTM
Microsoft
Bruxelles
Belgium
3800 m2
C4TTM
A c c e s s F l o o r
2-3
R a i s e d
Each geographical area has its
own peculiar raised access floor
requirements.
Blandonet Elvox
These range from extremes of Induini Padova
Geneve Italy
temperature and humidity, Switzerland 1500 m2
performance and combustibility, 28000 m2 C4TTM
which we have addressed. C4TTM
J.V.P. products satisfy global
standards.
Reuters
Induini
Geneve
Switzerland
3500 m2
P4TTM
Cyberport
Reyers Hong Kong Land
Bruxelles Pokfulam road
11500 M2 Hong Kong
Belgium 100000 m2
C4TTM C4TTM
A c c e s s F l o o r
4-5
R a i s e d
PATENT
US 6,418,697 BI
Number Idea
Potential of future based on the acquired knowledge
A c c e s s F l o o r
6-7
R a i s e d
PATENT
1019599
Number
It not only satisfies the demand for a light yet very robust product but
also performs at its best as part of the construction process.
For example, it is frequently used as a working platform for other trades.
Tools
To convert a Concept into reality
demands the right tool
Evolution on access floor panels
R a i s e d A c c e s s F l o o r
Performances Full sets of test results from
independent testing laboratories
We embrace Independent are available upon request.
Certification of product performances We comply with the European
Directive 106 referring to
building construction and
components.
A B
Centre of Edge of
Panel Panel
25 x 25 mm
square indentor
point load
Mechanical
resistance 106 /1
UNI EN 12825
Mechanical 2/3,0/A/1 4/3,0/A/1 5/3,0/A/1 6/3,0/A/1
resistance
140 °C max
UNI EN 13501-2
Resistance REI 30r REI 60r** REI 60r** REI 60r**
to the fire
Emitter Receiver
panels mm 600x600x23
Noise levels are related to the chipboard core inert core
quietness of the environment
but their contribution to standard C3TTL P3TTL P3TTM
personal stress in the workplace ISO R 717-1
is an important issue. Airborn noise, Dn,f,w dB 42 Dn,f,w dB 43 Dn,f,w dB 43
Consequently J.V.P. test all bare panels
panel models to perform at their
best on noise absorption to
ISO R 717-2
avoid potential health problems Impact noise, Ln,f,w dB 68 Ln,f,w dB 67 Ln,f,w dB 67
to building occupants. bare panels
14-15
R a i s e d A c c e s s F l o o r
panels mm 600x600x29
chipboard core inert core
standard C4TTL C4TTM P4TTM P4TTH
ISO R 717-1
Airborn noise, Dn,f,w dB 42 Dn,f,w dB 46 Dn,f,w dB 44 Dn,f,w dB 44
bare panels
ISO R 717-2
Impact noise, Ln,f,w dB 68 Ln,f,w dB 69 Ln,f,w dB 67 Ln,f,w dB 67
bare panels
Evolution on access floor panels
OHMS
R a i s e d A c c e s s F l o o r
With regard to electrical
hazards, the J.V.P. laminated
product and system fully
comply with the equipotential
earth bonding standards, as
well as with the human safety
antistatic requirements:
from 1010 to 108 Ohm
(auxiliary of computerized
components at 24V)
and conductivity performance
from 107 to 105 Ohm
(auxiliary of computerized
components at 220V).
CERT. IT08/0390 CERT. IT02/0113 JVP is partner of GBCI
Evolution on access floor panels
Nevertheless, the information given in this In detail, our JVP 4X4 fully accessible raised
document also satisfies the many other floor system could be considered positively in
parameters linked to different eco- contributing to getting the following LEED®
sustainability Standards. It is important to credits.
underline that LEED® is not and would not be
to any extent a product certification.
R a i s e d A c c e s s F l o o r
Credit MRc5 Credit MRc7 Other useful information, providing further evidence of our
Materials extracted, Timber endeavour to support sustainable resourcing, for which
worked and produced Certification JVP is very proud, are indicated below, and this information
will also contribute highly to our Green Credentials.
within regional limits
JVP is certified and systematically
Scope: Increment the
demand of building materials
Scope: Encouraging
environmentally
updated within the Environment
Quality System
ISO 14001
and products which are responsible management
JVP is certified and systematically
extracted and worked in
regional limits, sustaining in
of forests.
updated with the Quality Assurance
System
ISO 9001
this way local resources and The JVP 4X4 raised floor
JVP collects all the production
100 %
reducing the environment system contributes to this
residuals such as dusts and waste
impact coming from credit for the following
material that will be recycled at
transportation of the product. reasons:
R a i s e d A c c e s s F l o o r
Micrò
Screw Down
Accessories
Evolution on access floor panels
R a i s e d A c c e s s F l o o r
JVP
Raised access floor All technical data contained in this brochure are indicative only,
Pavimento sopraelevato accessibile we reserve the right to change specs without notice.
JVP
Raised access floor
Pavimento sopraelevato accessibile
07.2010 - studioverde.it
JVP
Raised access floor
Pavimento sopraelevato accessibile
Via Valletta, 3
Z. I. Cantarana
30010 Cona (VE)
Italy (European Union)
Tel. +39 0426 302630
Fax +39 0426 302814
www.jvph.net
jvp@jvph.net