Civil IFT Drawings

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 45

Drawings for Design Contract No.

1717-058-11
32 Avenue Widening from 184 Street to 188 Street
DRAWING INDEX DRAWING INDEX
DRAWING TYPE LIMITS DWG No. SHEET No. DRAWING TYPE LIMITS DWG No. SHEET No.

TOWNSHIP OF LANGLEY
CITY OF SURREY
SECTIONS
SECTIONS
SECTIONS
SECTIONS
DISTRICT OF DELTA
CITY OF SURREY

SECTIONS
SECTIONS
SECTIONS
SECTIONS
SECTIONS
SECTIONS
SECTIONS
SECTIONS

OTHER CONSULTANTS DRAWING INDEX


Consultant Location Description Drawing No.

ISSUED FOR TENDER


32 AVENUE ROADWORKS

CITY OF SURREY
CITY OF WHITE ROCK

BRITISH COLUMBIA CANADA

17-0069
BINNIE PROJECT NO:
General Notes Sedimentation Control
Summary of Material Testing Frequency
MATERIAL MMCD REFERENCE TESTING FREQUENCY

Storm Sewer

Tree Protection Notes

S S
S
SLOTTED LID
D

D
D
FD

W
W

As-Built Drawing W

W
T T
E E
G G
L L

ISSUED FOR TENDER


CITY OF SURREY AS SHOWN 1717-058-11
NOTES
32 AVENUE WIDENING (184 ST - 188 ST)
N1
Typical Ditch Detail

Modified Barrier Curb Detail

Sidwalk 125mm Drop Detail

FLOW DIRECTION FLOW DIRECTION

PROTECTION BARRIER EXISTING TREE CENTERED


WITHIN TREE PROTECTION Plan View
N.T.S.
EXISTING TREE CENTERED
WITHIN TREE PROTECTION 2 - 38 x 89mm WOOD POSTS SET TOP OF BANK
300mm DEEP INTO FINISHED GRADE.
1.5H :1V MAX. (TYP)
ABOVE GRADE

- SPACE POSTS MAX 2.0m APART.


1200 HEIGHT
MINIMUM

INSTALL ADDITIONAL POSTS AND /OR


MIN. PROTECTION

DIAGONAL BRACING TO SUIT.


LOCATE PROTECTION
1.5H :1V MAX. (TYP)
FENCING AS SHOWN ON PLANS
DIST

FLOW DIRECTION
FLOW DIRECTION

T B B T DITCH BOTTOM

CLASS 10 RIP RAP


Section A-A Section B-B
PLASTIC MESH "SHOW FENCING" N.T.S. N.T.S.
Tree Protection Detail SECURED TO WOOD FRAME Check Dam Detail
FINISHED GRADE N.T.S.
38 x 89mm TOP RAIL, BOTTOM RAIL
Typical Driveway - Residential (Arterial)

Asphalt Drainage Curb

ELEV. UNKNOWN
EX. 114DP GAS
Catch Basin Lead Detail (TYP)
Bike Friendly Catch Basin (TYP)
ISSUED FOR TENDER
CITY OF SURREY AS SHOWN 1717-058-11
DETAILS
32 AVENUE WIDENING (184 ST - 188 ST)
D1
17

10

17

11
6 14 12
13 12 1 2 6
6 16 6 16
6 1 5
1 2 1
6 6 6
9 10

2 7
2
8
3
3a
5 4 4 3
7
3
4

PROVISIONAL ITEM IF DEEP LAYER OF PEAT IS FOUND


ONSITE. CONTRACTOR TO PRE-LOAD WITH 1.0m OF
COMMON EXCAVATION REUSE ABOVE PROPOSED
ASPHALT GRADES AND PROVIDE MONITORING
GAUGES PER GEOTECHNICAL INSTRUCTIONS.

14
6 11 5 12 16 14
6 1 6 1
2 2 6 10 12 16
6 6
1 5
6 1 5 6
5 9
CONTRACTOR TO ADJUST FILL 9
7 SLOPE AS REQUIRED AND WHERE 7
SUBGRADE PREPARATION AND DIRECTED BY THE CONTRACT
GEOGRID PLACEMENT UNDER GRAVEL ADMINISTRATOR TO ACCOMMODATE
9 3a ONSITE REUSE OF MATERIALS 2 2
BASE OF NEW ROAD STRUCTURE TO BE
REVIEWED AND CONFIRMED BY 15
GEOTECHNICAL ENGINEER WHERE 3a
3 15
PEAT ENCOUNTERED (APPROX. 7 TENSAR INTER-AX NX 750 GEOGRID OR
4
LOCATION SHOWN ON PLAN VIEW APPROVED EQUAL (SHOWN ON PLAN 8
BETWEEN STA. 2+260 TO STA. 2+350) VIEW BETWEEN STA. 2+260 TO STA. 3
2+350 WHERE PEAT ENCOUNTERED) 4

1H:1V SLOPE

COMPACTED PEAT LAYER


UNDER EXISTING ROAD
STRUCTURE TO REMAIN.

1.
1 150mm THICK SUPERPAVE (SURFACE LIFT: 65mm THICK 6.
5 FULL DEPTH MILLING OF EXISTING ASPHALT AND 10.
9 150mm THICK TOPSOIL AND HYDROSEED ROAD AND
TENSAR INTER-AX NX 750 GEOGRID OR 12.5mm SUPERPAVE, BASE LIFT: 85mm THICK 19mm OFFSITE DISPOSAL (TYP). DITCH BANKS INCLUDING ANY DISTURBED AREAS 15.
14 PROPOSED RAISED MEDIAN SECTION A-A c/w 100mm
APPROVED EQUAL TO BE PLACED OVER SUPERPAVE) THICK COLOURED RED BROOM FINISH PER SSD-R.15.2
PEAT LAYER GREATER THAN 1.0m 7.
6 BIKE FRIENDLY CURB PER SSD-D.9. 11. PROPOSED RETAINING WALL REFER TO DESIGN BY
10
2.
2 150mm - 19mm MINUS GRANULAR BASE COMPACTED GEOTECHNICAL ENGINEER 16.
15 PROPOSED TENSAR INTER-AX NX 750 GEOGRID OR
TO 95% MODIFIED PROCTOR DENSITY. 8.
7 CLEAN, FREE DRAINING WELL-GRADED PIT RUN SAND APPROVED EQUAL TO BE INSTALLED BELOW BASE
APPROX LOCATION OF PEAT LAYER 11 COMMON EXCAVATION REQURIED FOR ROAD
AND GRAVEL WITH LESS THAN 5% FINES (PERCENT 12. GRAVELS (SHOWN ON PLAN VIEW BETWEEN STA.
TO BE REMOVED - MAX. DEPTH 1.0m
3.
3 450mm - 75mm MINUS CRUSHED GRANULAR SUBBASE PASSING THE #200 SIEVE). FILL MATERIAL SHALL BE LOWERING TO MEET DESIRABLE GRADES (SEE PLAN 2+260 TO STA. 2+350 WHERE PEAT ENCOUNTERED)
COMPACTED TO 95% MODIFIED PROCTOR DENSITY. PLACED AND COMPACTED IN LIFTS WITH EACH LIFT VIEW)
CONTRACTOR TO TEST DIG IN FIELD COMPACTED TO AT LEAST 95% MPD (EACH LIFT MAX. 17.
16 PROP. 50mm THICK MMCD UC #2 ASPHALT MUP c/w
EXTENTS OF EXISTING PRELOAD AT 20m 4. DEPTH VARIES AS REQUIRED FOR PROP. GRADING -
3a 0.6m THICK) 13.
12 150mm TOPSOIL AND SOD GRANULAR BASE AND SUBBASE AS PER SSD-R.21 AND
STATIONS TO DETERMINE BOTH THE 75mm MINUS CRUSHED GRANULAR SUBBASE SSD-R.21.1.
HORIZONTAL POSITION AND VERTICAL COMPACTED TO 95% MODIFIED PROCTOR DENSITY. 89. COMMON EXCAVATION - DEPTH DETERMINED BY THE 14.
13 PROPOSED MEDIAN PLANTING SECTION PER SSD-R.16
THICKNESS TO EX. PEAT LAYER. CONTRACT ADMINISTRATOR IN THE FIELD (ASSUMED AND RAISED MEDIAN SECTION B-B c/w 100mm THICK 18.
17 PROP. 1.2m HIGH HANDRAIL AT TOP OF RETAINING
5.
4 APPROVED SUBGRADE. 0.5m). PRIOR TO PLACING ROADWAY FILLS, STRIPPED COLOURED, STAMPED DAVIS RED BRICK PER WALL AS PER MMCD C14 TO BE POWDERCOATED/
SURFACES SHALL BE REVIEWED BY THE SSD-R.15.2 PAINTED BLACK (SEE PLAN VIEW)
GEOTECHNICAL ENGINEER.

ISSUED FOR TENDER


CITY OF SURREY NOT TO SCALE 1717-058-11
TYPICAL SECTIONS
32 AVENUE WIDENING (184 - 188 ST)
TYP1
CONTRACTOR TO INSTALL CLEAR/GRUB EX. REFER TO TYPICAL
ELECTRICAL APPURTENANCES TO REFER TO DMD SECTION ON SHEET EX. UTILITY POLE
TREES/SHRUBS/BUSHES APPROX.
ULTIMATE DESIGN GRADES AND DRAWINGS FOR STREET CONSTRUCTION DETAILS (PH1) FOR ROAD TO BE REMOVED
WITHIN R.O.W. (TYP).
FILL SURROUNDING GROUND LIGHTING DESIGN (TYP). LIMIT PAVEMENT STRUCTURE. (BY OTHERS). CATCH BASIN TABLE
PROP. STYLE 1 CONC. EXTRUDED

5+100
WITH IMPORT SUBBASE AND BASE
CURB AS PER MMCD C6 AT CURB GRAVELS TO SUIT. NUMBER DESCRIPTION LOCATION OF CATCHBASIN RIM ELEV.

184 Street
RETURN AND ASPHALT
EX. UTILITY POLE
SIDEWALK/WHEELCHAIR RAMP CB01 900mmØ CB - DOUBLE SIDE INLET STA. 1+819.61 o/s 6.45 10.93
EX. UTILITY POLE TO BE REMOVED
AT BACK OF CURB FOR FUTURE
TO BE RETAINED. (BY OTHERS). CB02 900mmØ CB - DOUBLE SIDE INLET STA. 1+820.48 o/s -10.35 10.85
WIDENING OF 184 ST.

EX. UTILITY POLE CB03 900mmØ CB - DOUBLE SIDE INLET STA. 1+919.24 o/s -9.36 12.64
A 3237 REM S 1/2

0+000
TO BE RETAINED. NEW INSTALLED
NEW INSTALLED NEW INSTALLED CB04 900mmØ CB - DOUBLE SIDE INLET STA. 1+918.42 o/s 6.45 12.70

9.73m-GAS
UTILITY POLE. 18611
UTILITY POLE. UTILITY POLE.
6.10m-GAS

REMOVE EX.
CB'S & LEAD
32 Avenue

FOR CONTINUATION SEE R1-7


0+027

MATCHLINE STA: 2+000


H
H

7.35m
10.35m
CB02 CB03

LIMIT OF CONTRACT

9.55m
A 2+000

EX. 600Ø CP STM.


EX. 114DP GAS 9.894 10.246
1+700 1+800 1+900 D EX. 114DP GAS

6.45m
E

6.45m
6.45m
CB01 CB04
E A

0.60m MEDIAN
EX. 375Ø CP STM. 10.175
9.857 H EX. 450Ø CP STM.
EX. 525Ø CP STM. C

389.56

3.00m MUP
GENERAL NOTES

3.67m-STM
23.70m-ROW
20.11m-ROW
5.67m-STM

1. REFER TO PAVEMENT MARKING AND SIGNAGE ON SHEET


PM1-3-1 TO 1PM1-4.

EX. 375Ø CP STM.


EX. UTILITY POLE 2. ALL EXISTING MH LIDS, WV'S, IC'S, METER COVERS AND
TO BE RETAINED. EX. UTILITY POLE PROP. RETAINING NEW BIKE REMOVE EX. CATCH PROP. APPROX. 50m FORMAL VEHICLE
FRIENDLY CB PER BASINS AND DISPOSE BARRIER AT 1.0 BACK OF NEW CURB GV'S TO BE ADJUSTED TO SUIT PROPOSED WORKS.
TO BE RETAINED WALL (TYP). SEE SHEET
ADJUST EX. MANHOLE COVERS RW1-1A FOR DETAILS SSD-D.9 (TYP). OF OFFSITE (TYP). AS PER SSD-PK6111 (TYP)
TO SUIT PROP. GRADES (TYP). 3. ALL ABANDONED MH'S AND CB'S LEFT IN PLACE TO BE
FILLED WITH COMPACTED GRANULAR SUBBASE AFTER
PROP. CULVERT CROSSING
1 3181 ALL ABANDONED CONNECTIONS ARE FILLED WITH
c/w TEMPORARY END CAPS.
CONCRETE SACS. RIMS AND CONCRETE LIDS TO BE
REFER TO SHEET
W ST1-D1
1/2 A

79.91
3126 REMOVED TO A MINIMUM OF 1.0m BELOW FINISHED
FOR DETAILS
GRADE.
REFER TO SHEET R1-9
4. IN ROADWAY, REMOVE AND REPLACE ALL EX. MH
FOR INTERSECTION
FRAMES AND COVERS WITH TYPE 1 HEIGHT ADJUSTABLE
GRADING
FRAMES AND COVERS. REFER TO SSD-S.2S1 & SSD-S.2.2
(TYP).

16 5. INSTALL MIN. 0.3m WIDE SHOULDER BEHIND STREET


LIGHT POLE BASE AS PER MMCD DWG CE1.20 (TYP).

6. REFER TO DETAILS ON SHEET 17-0069-R1-9 FOR CURB


RETURN INFORMATION
15
7. FOR RESTORATION WORKS ON PRIVATE PROPERTIES,
REFER TO CONSENT AGREEMENTS OF TENDER
DOCUMENTS.
PROP. CL/SOUTH
14 MEDIAN GL PROFILE 14 8. ALL EXISTING SIGNS TO BE TEMPORARILY REMOVED
PROP. NORTH DURING CONSTRUCTION AND REINSTATED AS DIRECTED
MEDIAN GL PROFILE BY THE CONTRACT ADMINISTRATOR.

13 13
KEY NOTES
A.
A MODIFIED CONCRETE BIKE FRIENDLY BARRIER CURB PER
1.8% DETAIL ON DWG "TYP1"

12 12 B
B. REMOVE EX. ASPHALT DRIVEWAY. INSTALL 65mm UC#2
PROP. SOUTH EX. GROUND PROFILE ASPHALT RESIDENTIAL DRIVEWAY c/w 100mm OF 19mm
GL/EDGE OF MINUS CRUSHED GRANULAR BASE ON APPROVED
ASPHALT PROFILE SUBGRADE AS PER SSD-G.5. DRIVEWAY TO BE DROPPED
125mm AS PER DETAIL ON DWG. "TYP1".
11 PROP. NORTH 11
1.8% GL/EDGE OF C.
C PROP. 3.0m-WIDE ASPHALT PATHWAY (65mm THICK UC#2)
APSHALT PROFILE PER SSD-R21-1
2.2% 1.7%
D
D. PROP. 3.3m-WIDE RAISED MEDIAN c/w BICYCLE FRIENDLY
10 1.0% 10 CURB PER SSD-R15.2

E
E. PROP. 0.6-0.9m-WIDE RAISED MEDIAN c/w BICYCLE
FRIENDLY CURB PER SSD-R15.2
9 9 E
F. 150mm THICK CONCRETE RESIDENTIAL DRIVEWAY
CROSSING. REFER TO DETAIL ON DWG "TYP1"

F
G. PROP. MIN. 3.5m WIDE SINGLE LEDTOWN AS PER
8 8 SSD-R-26.3

H.
H PROP. MIN. 3.5m WIDE SPLIT LETDOWN AS PER
10.041

11.201

11.921
10.188

10.246

10.348

10.517

10.686

10.809
10.842

11.022

11.380

11.560

11.739

12.105

12.285

12.470

12.659

12.849

13.038

13.229

13.420

13.604

13.814

14.048

14.288
9.894

PROP. NGL SSD-R-26.1

Legend

13.231
11.058
11.106

11.286

11.465

11.644

11.824

12.002

12.165

12.312

12.480

12.663

12.852

13.042

13.419

13.609

13.793

14.002

14.237

14.476
PROP. NMGL
NEW ASPHALT PAVEMENT
C/W BASE AND SUBBASE

MIN. 50mm MILL & OVERLAY EX.


10.530

13.093

13.273

13.453
10.122

10.309

10.752

10.938

11.069
11.117

11.297

11.476

11.656

11.836

12.015

12.195

12.375

12.554

12.734

12.914

13.632

13.815

14.024

14.259

14.499
9.991

PROP. SMGL/CL ASPHALT PAVEMENT

FULL DEPTH MILLING OF EX. ASPHALT.


ADD BASE AS REQUIRED AND INSTALL
NEW ASPHALT PAVEMENT
11.471

14.071
10.119

10.175

10.306

10.525

10.744

10.908
10.933

11.112

11.292

11.650

11.830

12.009

12.188

12.368

12.547

12.727

12.906

13.086

13.266

13.445

13.627

13.836

14.310
9.981
9.857

PROP. SGL FULL DEPTH MILLING OF EX.


ASPHALT. INSTALL NEW ASPHALT
PAVEMENT C/W BASE AND SUBBASE
10.092

10.184

10.343

10.582

10.649

10.929

11.145

11.344

11.558

11.724

11.850

11.929

11.972

12.027

12.147

12.322

12.542

12.762

13.003

13.280

13.583

13.883

14.159

14.398
9.791

9.991
9.896

EX. BASELINE REMOVE EXISTING TREE

ISSUED FOR TENDER


1+783.991

1+817.564

2+000
1+740

1+750

1+760

1+770

1+780

1+790

1+800

1+810

1+820

1+830

1+840

1+850

1+860

1+870

1+880

1+890

1+900

1+910

1+920

1+930

1+940

1+950

1+960

1+970

1+980

1+990
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

ROADWORKS
32 AVENUE WIDENING (184 ST - 188 ST)32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS R1-6
STA. 2+130 TO STA. 2+396:
INSTALL APPROX. 266m LONG GUARD RAIL AS PER SSD-R.19 &
SSD-R.19.1 C/W TERMINAL SECTIONS. FACE OF RAIL SHALL BE FLUSH
WITH FACE OF CURB. INSTALL WHITE BUTTERFLY REFLECTORS (BY
PEXCO) ON GUARD RAIL AT 3m SPACING. INSTALL 41mm BARRIER
PEAT REMOVAL AREA.
FLEXTAB (BY PEXCO) EVERY 3m ON TOP OF BARRIER. STREET
REFER TO TYPICAL SECTION ON
LIGHTING POLE TO BE PLACED BEHIND GUARD RAIL IN THIS SECTION.
SHEET TYP1 FOR PEAT REMOVAL
AND TO BE REVIEWED BY GENERAL NOTES
REFER TO DMD DRAWINGS FOR GEOTECHNICAL ENGINEER.
STREET LIGHTING DESIGN (TYP).
ASPHALT EDGE c/w 1. REFER TO PAVEMENT MARKING AND SIGNAGE ON SHEET
REMOVE EX. CATCH APPROX. EX. UTILITY POLE APPROXIMATE EX. UTILITY POLE GRAVEL SHOULDER AT REFER TO TYPICAL EX. UTILITY POLE APPROXIMATE EX. UTILITY POLE PM1-3-1 TO 1PM1-4.
BASINS AND DISPOSE CONSTRUCTION TO BE REMOVED EXTENTS OF TO BE REMOVED 2.5% CROSS SLOPE (TYP). SECTION ON SHEET TYP1 TO BE REMOVED EXTENTS OF TO BE REMOVED
OF OFFSITE (TYP). LIMIT (BY OTHERS). PROP. FILL SLOPE (BY OTHERS). FOR ROAD WIDENING (BY OTHERS). PROPOSED FILL SLOPE (BY OTHERS). 2. ALL EXISTING MH LIDS, WV'S, IC'S, METER COVERS AND
GV'S TO BE ADJUSTED TO SUIT PROPOSED WORKS.
NEW INSTALLED NEW INSTALLED NEW INSTALLED NEW INSTALLED NEW INSTALLED REM S 1/2 NEW INSTALLED 3. ALL ABANDONED MH'S AND CB'S LEFT IN PLACE TO BE
UTILITY POLE. UTILITY POLE. UTILITY POLE. UTILITY POLE. UTILITY POLE. UTILITY POLE.

9.15m-GAS
9.73m-GAS
18611 FILLED WITH COMPACTED GRANULAR SUBBASE AFTER

PAVEMENT
ALL ABANDONED CONNECTIONS ARE FILLED WITH

6.60m
CONCRETE SACS. RIMS AND CONCRETE LIDS TO BE
32 Avenue REMOVED TO A MINIMUM OF 1.0m BELOW FINISHED
GRADE.
FOR CONTINUATION SEE R1-6

FOR CONTINUATION SEE R1-8


4. IN ROADWAY, REMOVE AND REPLACE ALL EX. MH
MATCHLINE STA: 2+000

MATCHLINE STA: 2+300


FRAMES AND COVERS WITH TYPE 1 HEIGHT ADJUSTABLE

7.35m
7.35m
CB08 A CB09 CB12 FRAMES AND COVERS. REFER TO SSD-S.2S1 & SSD-S.2.2
CB06 E 2+300
2+000 2+100 2+200 (TYP).
EX. 114DP GAS
EX. 114DP GAS

6.45m
6.00m 6.00m

6.45m
CB07 CB13 5. INSTALL MIN. 0.3m WIDE SHOULDER BEHIND STREET
A CB10 CB11

0.60m MEDIAN
CB05 F F LIGHT POLE BASE AS PER MMCD DWG CE1.20 (TYP).

EX. 375Ø CP STM. 6. REFER TO DETAILS ON SHEET 17-0069-R1-9 FOR CURB


EX. 450Ø CP STM. C
RETURN INFORMATION
4.50m

1.20m BLVD
6.00m

PAVEMENT
7. FOR RESTORATION WORKS ON PRIVATE PROPERTIES,

3.00m MUP
6.60m
48.66 48.66
389.56
REFER TO CONSENT AGREEMENTS OF TENDER
B B

4.18m-STM
3.59m-STM

23.84m-ROW
23.70m-ROW
CATCH BASIN TABLE DOCUMENTS.
RELOCATE EX.
NUMBER DESCRIPTION LOCATION OF CATCHBASIN RIM ELEV. PRIVATE MAIL APPROXIMATE EXTENTS 8. ALL EXISTING SIGNS TO BE TEMPORARILY REMOVED
BOX (TYP.) OF PROP. FILL SLOPE DURING CONSTRUCTION AND REINSTATED AS DIRECTED
CB05 900mmØ CB - DOUBLE SIDE INLET STA. 2+026.45 o/s 6.45 14.94 BY THE CONTRACT ADMINISTRATOR.
ADJUST EX. MANHOLE NEW BIKE REMOVE EX. CATCH PROP. CONCRETE BOX
CB06 900mmØ CB - DOUBLE SIDE INLET STA. 2+026.48 o/s -7.35 14.92 COVERS TO SUIT FRIENDLY CB PER BASINS AND DISPOSE CULVERT FOR WILDLIFE KEY NOTES
PROP. GRADES (TYP). SSD-D.9 (TYP). OF OFFSITE (TYP). CORRIDOR CROSSING. REFER
CB07 900mmØ CB - DOUBLE SIDE INLET STA. 2+104.50 o/s 6.45 16.81 TO SHEET ST1-D1 FOR DETAILS A.
A MODIFIED CONCRETE BIKE FRIENDLY BARRIER CURB PER
CLEAR/GRUB EX. TREES/SHRUBS/ ADJUST GATE AS DETAIL ON DWG "TYP1"
CB08 900mmØ CB - DOUBLE SIDE INLET STA. 2+104.50 o/s -7.35 16.79 BUSHES WITHIN R.O.W. (TYP). REQUIRED TO 18640
18600
ACCOMMODATE B
B. REMOVE EX. ASPHALT DRIVEWAY. INSTALL 65mm UC#2
CB09 900mmØ CB - DOUBLE SIDE INLET STA. 2+199.77 o/s -7.35 20.06 3126 W 1/2 A W 1/2 4 DRIVEWAY E 1/2 4
ASPHALT RESIDENTIAL DRIVEWAY c/w 100mm OF 19mm
REGRADING (TYP.) MINUS CRUSHED GRANULAR BASE ON APPROVED
CB10 900mmØ CB - SIDE INLET STA. 2+199.77 o/s 6.45 20.08
SUBGRADE AS PER SSD-G.5. DRIVEWAY TO BE DROPPED
CB11 900mmØ CB - SIDE INLET STA. 2+249.77 o/s 6.45 21.93 125mm AS PER DETAIL ON DWG. "TYP1".

CB12 900mmØ CB - SIDE INLET STA. 2+266.48 o/s -7.35 22.57 C.


C PROP. 3.0m-WIDE ASPHALT PATHWAY (65mm THICK UC#2)
PVI STA = 2+299.775 PER SSD-R21-1
CB13 900mmØ CB - SIDE INLET STA. 2+296.78 o/s 6.45 24.38 PVI EL = 23.970
21 21 26 26
K = 10.00 D
D. PROP. 3.3m-WIDE RAISED MEDIAN c/w BICYCLE FRIENDLY
AD = 8.10% CURB PER SSD-R15.2
LVC = 80.99
E
E. PROP. 0.6-0.9m-WIDE RAISED MEDIAN c/w BICYCLE

BVCE: 22.472
BVCS: 2+259.280
20 20 25 25 FRIENDLY CURB PER SSD-R15.2

E
F. 150mm THICK CONCRETE RESIDENTIAL DRIVEWAY
CROSSING. REFER TO DETAIL ON DWG "TYP1"

19 19 24 24 F
G. PROP. MIN. 3.5m WIDE SINGLE LEDTOWN AS PER
PROP. NORTH SSD-R-26.3
MEDIAN GL PROFILE PROP. CL/SOUTH H.
H PROP. MIN. 3.5m WIDE SPLIT LETDOWN AS PER
PROP. CL/SOUTH MEDIAN GL PROFILE SSD-R-26.1
18 MEDIAN GL PROFILE
18 23 23
PROP. NORTH
MEDIAN GL PROFILE Legend
NEW ASPHALT PAVEMENT
17 17 22 22 C/W BASE AND SUBBASE
EX. GROUND PROFILE MIN. 50mm MILL & OVERLAY EX.
ASPHALT PAVEMENT
EX. GROUND PROFILE
16 16 21 21 FULL DEPTH MILLING OF EX. ASPHALT.
PROP. SOUTH ADD BASE AS REQUIRED AND INSTALL
2.4% PROP. SOUTH NEW ASPHALT PAVEMENT
GL/EDGE OF
ASPHALT PROFILE GL/EDGE OF FULL DEPTH MILLING OF EX.
ASPHALT PROFILE ASPHALT. INSTALL NEW ASPHALT
15 PROP. NORTH 15 20 3.7% 20 PAVEMENT C/W BASE AND SUBBASE
GL/EDGE OF PROP. NORTH
APSHALT PROFILE GL/EDGE OF
APSHALT PROFILE REMOVE EXISTING TREE

14 14 19 19

13 18
16.201

16.441

20.067

20.437

20.807

21.177

21.547

21.917

22.288

22.716

23.243

23.870

24.597
14.288

14.527

14.766

15.005

15.245

15.484

15.723

15.962

16.680

16.919

17.160

17.477

17.847

18.217

18.587

18.957

19.327

19.697
PROP. NGL
16.151

20.256

20.626

20.996

21.366

21.736

22.106

22.477

22.904

23.432

24.059

24.786
14.476

14.715

14.955

15.433

15.672

15.912

16.390

16.629

16.869

17.108

17.349

17.666

18.036

18.406

18.776

19.146

19.516

19.886
15.194

PROP. NMGL
16.891

17.371

20.278

20.648

21.018

21.388

21.758

22.128

22.499

22.926

23.453

24.080

24.807
14.499

14.738

14.977

15.216

15.456

15.695

15.934

16.173

16.413

16.652

17.130

17.688

18.058

18.428

18.798

19.168

19.538

19.908
PROP. SMGL/CL

20.090

20.460

20.830

21.200

21.570

21.940

22.310

24.619
22.737

23.264

23.892
14.310

14.549

14.789

15.028

15.267

15.506

15.746

15.985

16.224

16.463

16.703

16.942

17.183

17.500

17.870

18.240

18.610

18.980

19.350

19.720
PROP. SGL
15.691

16.151

19.041

19.831

20.208

20.557

20.897

21.237

21.632

22.023

22.392

22.824

23.342

23.969

24.616
14.398

14.599

14.742

14.978

15.212

15.449

15.922

16.375

16.652

16.900

17.167

17.513

17.890

18.249

18.646

19.434

EX. BASELINE

ISSUED FOR TENDER

2+300.001
2+000

2+010

2+020

2+030

2+040

2+050

2+060

2+070

2+080

2+090

2+100

2+110

2+120

2+130

2+140

2+150

2+160

2+170

2+180

2+190

2+200

2+210

2+220

2+230

2+240

2+250

2+260

2+270

2+280

2+290

2+300
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

ROADWORKS
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS R1-7
STA. 2+130 TO STA. 2+396:
INSTALL APPROX. 266m LONG GUARD RAIL AS PER SSD-R.19 &
SSD-R.19.1 C/W TERMINAL SECTIONS. FACE OF RAIL SHALL BE FLUSH
Legend WITH FACE OF CURB. INSTALL WHITE BUTTERFLY REFLECTORS (BY CATCH BASIN TABLE CATCH BASIN TABLE
NEW ASPHALT PAVEMENT PEXCO) ON GUARD RAIL AT 3m SPACING. INSTALL 41mm BARRIER
C/W BASE AND SUBBASE FLEXTAB (BY PEXCO) EVERY 3m ON TOP OF BARRIER. STREET NUMBER DESCRIPTION LOCATION OF CATCHBASIN RIM ELEV. NUMBER DESCRIPTION LOCATION OF CATCHBASIN RIM ELEV.
LIGHTING POLE TO BE PLACED BEHIND GUARD RAIL IN THIS SECTION.
MIN. 50mm MILL & OVERLAY EX. CB14 900mmØ CB - SIDE INLET STA. 2+306.48 o/s -7.35 25.13 CB20 900mmØ CB - SIDE INLET STA. 2+449.77 o/s 6.45 41.07
ASPHALT PAVEMENT
CB15 900mmØ CB - SIDE INLET STA. 2+346.48 o/s -7.35 29.27 CB21 900mmØ CB - SIDE INLET STA. 2+465.76 o/s -0.74 42.57
PEAT REMOVAL AREA.
FULL DEPTH MILLING OF EX. ASPHALT. REFER TO TYPICAL SECTION ON CB16 900mmØ CB - SIDE INLET STA. 2+349.77 o/s 6.45 29.68 CB22 900mmØ CB - SIDE INLET STA. 2+499.77 o/s 8.21 44.26
ADD BASE AS REQUIRED AND INSTALL SHEET TYP1 FOR PEAT REMOVAL
NEW ASPHALT PAVEMENT AND TO BE REVIEWED BY CB17 900mmØ CB - SIDE INLET STA. 2+385.00 o/s -0.75 34.02 CB23 900mmØ CB - SIDE INLET STA. 2+507.86 o/s -7.21 44.83
FULL DEPTH MILLING OF EX. GEOTECHNICAL ENGINEER.
NEW INSTALLED
ASPHALT. INSTALL NEW ASPHALT CB18 900mmØ CB - SIDE INLET STA. 2+399.77 o/s 6.45 35.58 CB24 900mmØ CB - SIDE INLET STA. 2+545.77 o/s -7.10 45.14
UTILITY POLE.
PAVEMENT C/W BASE AND SUBBASE APPROXIMATE
EX. UTILITY POLE EX. UTILITY POLE CB19 900mmØ CB - SIDE INLET STA. 2+426.48 o/s -0.75 38.90 CB25 900mmØ CB - SIDE INLET STA. 2+549.78 o/s 9.62 45.10
EXTENTS OF ONSITE SIDEWALK
TO BE REMOVED PROPOSED CONTINUATION TO BE TO BE REMOVED NEW INSTALLED CONTRACTOR TO MILL EXISTING
REMOVE EXISTING TREE NEW INSTALLED

EX. 88DP GAS


(BY OTHERS). FILL SLOPE. DESIGNED BY OTHERS (BY OTHERS). UTILITY POLE. SEE SHEET R1-9 INTERSECTION AND REPROFILE
UTILITY POLE. FOR CURB THE CROWN TO SUIT PROPOSED
EX. UTILITY POLE PROP. GRAVEL PATHWAY WIDENING AND IMPROVEMENTS.
EX. UTILITY POLE RETURN DETAILS
NEW INSTALLED TO BE REMOVED PROP. STORM SEWER. PROP. RETAINING WALL ALONG TOP OF RET. WALL.
UTILITY POLE. (BY OTHERS). NEW INSTALLED TO BE REMOVED SEE SHEET ST1-4 FOR LIMITS (TYP). SEE DWG. 0 REFER TO TYPICAL SECTION

6.99m-GAS
9.01m-GAS UTILITY POLE. (BY OTHERS). DETAILS. RW1-2 FOR DETAILS. 18793 ON SHEET TYP1 FOR DETAILS.

0.60m MEDIAN
32 Avenue 8.0m
FOR CONTINUATION SEE R1-7

EX. TEL DUCTS

MEDIAN
0.60m
EX. 600Ø PVC STM.
MATCHLINE STA: 2+300

3.30m
MAX.

6.60m
6.60m

CB14 CB15 D D A CB23 EX. 600Ø PVC STM. CB24

7.0m
D D 2+600
2+300 EX. 114DP GAS 2+400 E 2+500 E

.
STM
EX. 114DP GAS

EX. 300Ø DI WAT.

PVC
D

PAVEMENT
CB17 CB21
6.60m

6.00m 6.00m 6.00m CB19

VARIES
9.60m
CB16 CB18 CB20

00Ø

EX. 350Ø DI WAT.


6.60m
F F F A

EX. TEL DUCTS


CB22 CB25

EX. 3
EX. 300Ø CP STM. EX. 300Ø PVC STM.
C EX. 300Ø PVC STM. EX. 250Ø CP STM.
6.00m 6.00m 4.50m
1.20m BLVD
3.00m MUP C
48.65 8.0m

EX. 60DP GAS


4.18m-STM
23.84m-ROW

193.61
B B B

7.33m-STM
27.28m-ROW
CONTRACTOR TO MILL EXISTING

188 Street
EX. UTILITY POLE EX. UTILITY POLE INTERSECTION AND REPROFILE
EX. UTILITY POLE
TO BE REMOVED TO BE RETAINED. THE CROWN TO SUIT PROPOSED
ADJUST EX. MANHOLE TO BE REMOVED
APPROXIMATE REFER TO DMD WIDENING AND IMPROVEMENTS.
COVERS TO SUIT (BY OTHERS). (BY OTHERS).
EXTENTS OF DRAWINGS FOR STREET
PROP. GRADES (TYP).
PROPOSED FILL SLOPE LIGHTING DESIGN (TYP). A 3177 3188 A
RELOCATE EX. PROP. RETAINING WALL
PRIVATE MAIL LIMITS (TYP). SEE DWG. REMOVE EX. CATCH
BOX (TYP.) PVI STA = 2+299.775
18660 RW1-1 FOR DETAILS. BASINS (TYP).
PVI EL = 23.970 18676
W 1/2 5
K = 10.00 E 1/2 5
AD = 8.10%
32 LVC = 80.99 32 39 39 44 44 48 48 GENERAL NOTES

BVCS: 2+421.157
EVCS: 2+340.269
EVCE: 28.748

BVCE: 38.292
1. REFER TO PAVEMENT MARKING AND SIGNAGE ON SHEET
PVI STA = 2+476.941 PM1-3-1 TO 1PM1-4.
PVI EL = 44.874
31 31 38 38 43 43 47K = 10.00 47
2. ALL EXISTING MH LIDS, WV'S, IC'S, METER COVERS AND
AD = -11.16% GV'S TO BE ADJUSTED TO SUIT PROPOSED WORKS.
LVC = 111.57
3. ALL ABANDONED MH'S AND CB'S LEFT IN PLACE TO BE

EVCE: 45.232
EVCS: 2+532.724
PROP. CL/SOUTH FILLED WITH COMPACTED GRANULAR SUBBASE AFTER
30 30 37 37 42 42 46 46
PROP. CL/SOUTH MEDIAN GL PROFILE ALL ABANDONED CONNECTIONS ARE FILLED WITH
MEDIAN GL PROFILE CONCRETE SACS. RIMS AND CONCRETE LIDS TO BE
EX. GROUND PROFILE 0.6% REMOVED TO A MINIMUM OF 1.0m BELOW FINISHED
PROP. NORTH
GRADE.
MEDIAN GL PROFILE PROP.
29 29 36 36 41 41 NORTH
45 45
MEDIAN GL PROFILE 4. IN ROADWAY, REMOVE AND REPLACE ALL EX. MH
FRAMES AND COVERS WITH TYPE 1 HEIGHT ADJUSTABLE
EX. GROUND PROFILE
FRAMES AND COVERS. REFER TO SSD-S.2S1 & SSD-S.2.2
(TYP).
28 28 35 35 40 40 44 44
PROP. SOUTH 5. INSTALL MIN. 0.3m WIDE SHOULDER BEHIND STREET
GL/EDGE OF LIGHT POLE BASE AS PER MMCD DWG CE1.20 (TYP).
PROP. SOUTH ASPHALT PROFILE
GL/EDGE OF 6. REFER TO DETAILS ON SHEET 17-0069-R1-9 FOR CURB
27 ASPHALT PROFILE 27 34 34 39 39 43 PROP. NORTH 43 RETURN INFORMATION
GL/EDGE OF
PROP. NORTH APSHALT PROFILE
%

7. FOR RESTORATION WORKS ON PRIVATE PROPERTIES,


.8

GL/EDGE OF
11

REFER TO CONSENT AGREEMENTS OF TENDER


APSHALT PROFILE DOCUMENTS.
26 26 33 33 38 38 42 42
8. ALL EXISTING SIGNS TO BE TEMPORARILY REMOVED
SIGNIFICANT CUT ALONG

BEND AT SOUTH GL
DURING CONSTRUCTION AND REINSTATED AS DIRECTED
SECTION TO FLATTEN GRADE
BY THE CONTRACT ADMINISTRATOR.
FROM CURRENTLY >12.5% TO
25 25 32 32 37 37 41 41
MAX 9.0% AS PER PREFERRED KEY NOTES
CONCEPTUAL PLAN
A.
A MODIFIED CONCRETE BIKE FRIENDLY BARRIER CURB PER
DETAIL ON DWG "TYP1"
24 31 36 40
B
B. REMOVE EX. ASPHALT DRIVEWAY. INSTALL 65mm UC#2
24.597

25.424

26.352

27.379

28.505

29.685

30.865

32.110

33.362

34.679

35.933

37.186

38.364

39.505

40.547

41.488

42.329

43.072

43.720

44.260

44.630

44.890

44.987

45.060

45.110

45.160

45.210

45.260

45.310

45.340
ASPHALT RESIDENTIAL DRIVEWAY c/w 100mm OF 19mm
PROP. NGL MINUS CRUSHED GRANULAR BASE ON APPROVED
SUBGRADE AS PER SSD-G.5. DRIVEWAY TO BE DROPPED
125mm AS PER DETAIL ON DWG. "TYP1".

45.521
24.786

25.613

26.540

27.568

28.694

29.874

31.054

32.233

33.426

34.616

35.806

36.996

38.175

39.316

40.358

41.300

42.140

42.882

43.530

44.070

44.507

44.828

45.050

45.193

45.262

45.327

45.392

45.457

45.544
45.562
C.
C PROP. 3.0m-WIDE ASPHALT PATHWAY (65mm THICK UC#2)
PROP. NMGL PER SSD-R21-1

D
D. PROP. 3.3m-WIDE RAISED MEDIAN c/w BICYCLE FRIENDLY
CURB PER SSD-R15.2
42.121

45.211

45.571
25.635

26.562

27.589

28.716

29.896

31.076

32.256

33.436

34.616

35.796

36.976

38.155

39.296

40.338

41.279

42.862

43.504

44.045

44.487

44.828

45.070

45.279

45.343

45.408

45.472

45.536

45.600
24.807

PROP. SMGL/CL E
E. PROP. 0.6-0.9m-WIDE RAISED MEDIAN c/w BICYCLE
FRIENDLY CURB PER SSD-R15.2

E
F. 150mm THICK CONCRETE RESIDENTIAL DRIVEWAY
41.090

44.269

44.600

45.273

45.360
24.619

25.446

26.373

27.403

28.528

29.708

30.888

32.067

33.247

34.427

35.607

36.787

37.967

39.107

40.148

41.932

42.668

43.296

43.824

44.826

44.966

45.042

45.097

45.185

45.392
PROP. SGL CROSSING. REFER TO DETAIL ON DWG "TYP1"

F
G. PROP. MIN. 3.5m WIDE SINGLE LEDTOWN AS PER
SSD-R-26.3
42.281

45.191

45.261
25.451

30.551
24.616

26.396

27.378

28.385

29.447

31.732

33.028

34.373

35.716

36.973

38.177

39.322

40.362

41.382

43.012

43.615

44.104

44.457

44.709

44.876

45.005

45.104

45.342

45.456

45.559

45.666
EX. BASELINE H.
H PROP. MIN. 3.5m WIDE SPLIT LETDOWN AS PER
SSD-R-26.1

ISSUED FOR TENDER


2+319.931
2+320.521

2+502.721
2+319.632
2+321.909

2+340.269

2+394.042

2+400.572

2+583.592
2+586.272
2+300.138

2+309.775
2+310.138
2+312.805

2+319.635
2+319.638
2+319.775
2+320.138

2+324.116
2+324.978
2+324.975

2+339.775
2+340.138

2+370.138

2+394.045
2+300

2+310

2+320

2+330

2+340

2+350

2+360

2+370

2+380

2+390

2+400

2+410

2+420

2+430

2+440

2+450

2+460

2+470

2+480

2+490

2+500

2+510

2+520

2+530

2+540

2+550

2+560

2+570

2+580

2+590

2+600
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

ROADWORKS
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS R1-8
10.329 10.342

5+080
10.346

5
0+01
10.350

424 45.49
10. MEET
45.37 45.57

184 STREET
10.3 45.372
97 0+000 7 45.48
3

4
45.355

7
.5
10
45.340

726
10 10.675
.3
32 AVENUE

10.849
65

10.
5 10.687

10.521 2+580 2+600 2+620

10
.30
10.246

1
45.82
32 AVENUE

5+060

45.555
1+780 1+800 1+820

45.750
10.687 10.788 10.951

MEET
10.943

45.392
10.175

10.
10.246

548
5

10.782 45.61
.32

10.512 10.747
10

10
5 4

.7
39 45.46

61
6 . 45.37
10
MEET 45.48
10.
63 667
10.4

188 STREET
10.505
10.574
5+040

10.518 10.538

CURVE TABLE CURVE TABLE


CURVE # LENGTH RADIUS DELTA BC EC CURVE # LENGTH RADIUS DELTA BC EC

3 16.733 11.000 087° 09' 23" 5436379.178/521150.137 5436368.726/521161.126 7 5.414 3.914 079° 15' 07" 5436369.568/521927.857 5436372.689/521931.754

4 17.296 11.000 090° 05' 18" 5436341.208/521150.263 5436352.225/521161.263

5 17.666 10.877 093° 03' 32" 5436364.728/521125.673 5436376.126/521136.596

6 13.489 8.226 093° 57' 10" 5436351.096/521128.829 5436341.928/521136.614

Grading Detail

ISSUED FOR TENDER


CITY OF SURREY 0 1:250 10m
1717-058-11
ROADWORKS
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS R1-9
GENERAL DRAINAGE NOTES

CONNECT LEAD OF EX. 1. SINGLE CB LEADS SHALL BE 200mmØ SDR35


3181 EX. HEADWALL TO 3237
BE PVC AND DOUBLE CB LEADS SHALL BE
CB TO EXTENDED DITCH.
REMOVED AND CULVERT 250mmØ SDR35 PVC.
EX. MANHOLE TO
TO BE ABANDONED (FILL IN
BE ABANDONED. EX. 450mmØ
EX. HEADWALL TO BE LIGHT CONCRETE SLURRY) 2. REFER TO SSD-G.4 AND G.5 FOR STORM
REMOVED AND CULVERT TO CULVERT TO REMAIN
SEWER TRENCH DETAIL.
BE ABANDONED (FILL IN
LIGHT CONCRETE SLURRY) 184 Street 3. ALL ABANDONED MHs AND CBs LEFT IN
79.91 PLACE SHALL BE FILLED WITH COMPACTED
GRANULAR SUBBASE AFTER ALL
ABANDONED CONNECTIONS HAVE BEEN
EX. 375Ø CP STM. EX. 450mmØ CULVERT FILLED WITH CONCRETE SACKS. RIMS AND
ELEV. =9.15 (INLET)

1+800
5+000 5+100 5+200 5+260 CONCRETE LIST TO BE REMOVED TO A
MINIMUM OF 1.0m BELOW FINISHED GRADE.

4. CONTRACTOR TO EXPOSE AND VERIFY ALL


EXISTING UTILITY CROSSINGS AND TIE-IN
EX. 600Ø CP STM.

LOCATIONS AND NOTIFY THE CONTRACT


ADMINISTRATOR OF ANY CONFLICTS OR
DISCREPANCIES PRIOR TO CONSTRUCTION.
GAS MAIN AND HYDRANT LEAD CROSSINGS
MAY REQUIRE REGRADING.

5. CONTRACTOR TO REPAIR AND REPLACE


D INFILL EX. DITCH. ANY DAMAGE TO OTHER UTILITIES DURING
EXTEND EX. CLASS A DITCH @ 0.5% THE STORM MAIN INSTALLATION.
MIN. TO NEW INLET STRUCTURE. STM
D92 6. REFER TO TYPICAL DITCH SECTION ON
INSTALL PRO-ECO-LITE HEADWALL (OR APPROX. SHEET D1.

EX. 525Ø CP STM.


APPROVED EQUIVALENT). CONSTRUCTION
3126
INLET LOCATION TO BE DETERMINED BY THE LIMIT 7. REFER TO CB LEAD DETAIL ON SHEET D1.
CONTRACT ADMINISTRATOR. CONNECT TO
STORM MANHOLE WITH 900mmØ SANITITE 8. NEW STANDARD STORM SEWER MANHOLE.
HP PIPE AT MIN. 0.5% SLOPE. INSTALL PRO-ECO-LITE REFER TO MMCD STD. DWG S1 & S2 (TYP).
W 1/2 A

HEADWALL (OR
NEW STANDARD STORM SEWER APPROVED EQUIVALENT).
MANHOLE. REFER TO MMCD STD.
DWG. S1 & S2 (TYP). INSTALL THE CONTRACTOR TO PROVIDE SUPPORT
MANHOLE COVER WITHIN MUP. FOR EXISTING HYDRO POLES AS
REQUIRED TO CONSTRUCT STORM
PROP. 900mmØ SANITITE HP. SEWER MAIN (TYP)
CULVERT (OR APPROVED
EQUIVALENT) @ MIN. 0.5% MATCHLINE STA: 1+860
FOR CONTINUATION SEE ST1-2 EX. TREE LINE TO BE
PROTECTED (TYP)

STM
D92
14 14
RIM: 11.13

1800mm

13 13
EX. 114DP GAS MAIN
LOCATION AND ELEVATION
TO BE CONFIRMED IN FIELD.
12 12
PROP. GROUND OVER EX. GROUND PROFILE
STORM PIPE ALONG 184 STREET BL

11 11

10 10

9 9
ELEV. UNKNOWN
EX. 114DP GAS

8 EX. 525mmØ STM 8


ALONG 32 AVE TO
CONNECT TO NEW MH.
INV.=9.58±
EX. 450mmØ
7 CULVERT TO REMAIN. 7
INV.=9.15

PROP. CLASS B
PROP. 8.86m-900mmØ
DITCH
SANITITE HP STM. @ 0.50% 6
(OR APPROVED EQUIVALENT)
9.168 SW
9.212 NE

9.147 N
9.58± E

9.000 S

PROP. 29.32m-900mmØ
PROP. STM DATA SANITITE HP STM. @ 0.50%
(OR APPROVED EQUIVALENT)

EX. STM DATA

ISSUED FOR TENDER


5+043.743

5+051.803
5+020

5+040

5+060

5+080

5+100

5+120

5+140

5+160

5+180

5+200

5+220

5+240
STATION
???

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

STORM SEWER
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS ST1-1
EX. 450mmØ
CULVERT TO REMAIN
MATCHLINE STA: 5+110
FOR CONTINUATION SEE ST1-1 NEW BIKE FRIENDLY DOUBLE NEW BIKE FRIENDLY DOUBLE NEW CLASS B DITCH WITH MIN.
CATCHBASIN PER SSD-D9 c/w CATCHBASIN PER SSD-D9 c/w 0.75m BOTTOM WIDTH AND
250mmØ LEAD. LOWER THE 250mmØ LEAD. LOWER THE 1.5H:1V SIDE SLOPE (TYP.)
REMOVE EX. FENCE AS APPROX.
GRATE BY 25mm AS PER MMCD GRATE BY 25mm AS PER MMCD
DIRECTED BY THE CONSTRUCTION GENERAL DRAINAGE NOTES
STD DWG S11 (TYP.) STD DWG S11 (TYP.) WIDEN DITCH BOTTOM WIDTH
CONTRACT ADMINISTRATOR. LIMIT TO 1.5m MIN. TO ALLOW FOR

5+100
B 32 Avenue SEDIMENT AND MAINTENANCE. 1. SINGLE CB LEADS SHALL BE 200mmØ SDR35

184 Street
PVC AND DOUBLE CB LEADS SHALL BE
CHECK DAM 250mmØ SDR35 PVC.
REFER TO DETAIL
ON SHEET D1 2. REFER TO SSD-G.4 AND G.5 FOR STORM
SEWER TRENCH DETAIL.
3237 REM S 1/2 3. ALL ABANDONED MHs AND CBs LEFT IN

9.73m-GAS
18611 PLACE SHALL BE FILLED WITH COMPACTED
EX. 600mmØ CULVERT TO GRANULAR SUBBASE AFTER ALL
BE ABANDONED (FILL IN ABANDONED CONNECTIONS HAVE BEEN
LIGHT CONCRETE SLURRY) FILLED WITH CONCRETE SACKS. RIMS AND
CONCRETE LIST TO BE REMOVED TO A

FOR CONTINUATION SEE ST1-3


MINIMUM OF 1.0m BELOW FINISHED GRADE.

MATCHLINE STA: 2+000


4. CONTRACTOR TO EXPOSE AND VERIFY ALL
EXISTING UTILITY CROSSINGS AND TIE-IN

D
2+000

EX. 600Ø CP STM.


LOCATIONS AND NOTIFY THE CONTRACT
1+800 1+900 EX. 114DP GAS ADMINISTRATOR OF ANY CONFLICTS OR
DISCREPANCIES PRIOR TO CONSTRUCTION.
STM GAS MAIN AND HYDRANT LEAD CROSSINGS
D92 MAY REQUIRE REGRADING.
EX. 450Ø CP STM.
EX. 525Ø CP STM. 5. CONTRACTOR TO REPAIR AND REPLACE
REMOVE EX. CB
ANY DAMAGE TO OTHER UTILITIES DURING
AND CAP LEAD.
389.56 THE STORM MAIN INSTALLATION.

3.67m-STM
23.70m-ROW
6. REFER TO TYPICAL DITCH SECTION ON
PROP. 900mmØ CULVERT.
CONNECT LEAD OF EX. SHEET D1.
SEE SHEET ST1-1 FOR
CB TO EXTENDED DITCH. DETAILS
7. REFER TO CB LEAD DETAIL ON SHEET D1.
CONNECT WALL DRAIN TO
EX. 375Ø CP STM.

THE PROPOSED STORM 8. NEW STANDARD STORM SEWER MANHOLE.


MAIN WITH 150mm SOLID REFER TO MMCD STD. DWG S1 & S2 (TYP).
PVC SDR35 PIPE (TYP)

CONTRACTOR TO REMOVE CONTRACTOR TO REMOVE NEW BIKE FRIENDLY DOUBLE


KEY NOTES
1 3181
LBs AND CONCRETE CBs AND CONCRETE CATCHBASIN PER SSD-D9 c/w 250mmØ
A. INSTALL 1.0m WIDE x 200mm THICK CLASS 10 RIP
3126 AND W 1/2 ASANDBAG LEADS TO BE B
79.91

SANDBAG LEADS LEAD. LOWER THE GRATE BY 25mm AS


DISPOSE OF OFFSITE (TYP) ABANDONED (FILL IN LIGHT PER MMCD STD DWG S11 (TYP.) RAP C/W UNDERLYING COCOMAT FROM THE
CONCRETE SLURRY) (TYP) OUTFALL TO THE BOTTOM OF THE PROP. DITCH.

16 16

15 15
WIDEN DITCH BOTTOM WIDTH
TO 1.5m MIN. TO ALLOW FOR
SEDIMENT AND MAINTENANCE.

14 14
EX. GROUND OF
NORTH DITCH
PROP. CL PROFILE
13 13
EX. GROUND PROFILE

12 12

11 11
PROP. BOTTOM
OF NORTH DITCH

10 10
EX. 600Ø CSP CULVERT
TO BE ABANDONED

9 EX. 450Ø CULVERT 9


TO BE RETAINED

PROP. 900Ø CULVERT


CROSSING
8
PROP. BOTTOM PROFILE OF
PROP. STM DATA RIPARIAN FEATURE REFER TO
SHEET D1 FOR DETAIL.

EX. 600mmØ
EX. STM DATA STM. @ 0.67%

ISSUED FOR TENDER


1+800

1+820

1+840

1+860

1+880

1+900

1+920

1+940

1+960

1+980
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

STORM SEWER
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS ST1-2
MEANDER TEMPORARY
STORM OUTLET DITCH
ALIGNMENT TO
NEW CLASS B DITCH WITH MIN. EX. SWALE PROTECT EX. TREES.
0.75m BOTTOM WIDTH AND TO REMAIN.
1.5H:1V SIDE SLOPE (TYP.)
MEANDER PROP.
DITCH ALIGNMENT TO
PROTECT EX. TREE. NEW BIKE FRIENDLY DOUBLE
CONTRACTOR TO REMOVE CATCHBASIN PER SSD-D9 c/w
LBs AND CONCRETE 250mmØ LEAD. LOWER THE
SANDBAG LEADS AND PROTECT 1.5H:1V DAYLIGHT TO GRATE BY 25mm AS PER MMCD 1.5H:1V DAYLIGHT TO PROTECT INSTALL MIN. 5m LONG, 450mm GENERAL DRAINAGE NOTES
DISPOSE OF OFFSITE (TYP) EX. TREE. EX. GROUND (TYP) STD DWG S11 (TYP.) APPROX. EX. GROUND (TYP) EX. TREE. THICK CLASS 25 RIP RAP C/W
CONSTRUCTION NATIVE SUBSTRATE MATERIAL. 1. SINGLE CB LEADS SHALL BE 200mmØ SDR35

0
LIMIT

0+06
PVC AND DOUBLE CB LEADS SHALL BE
CHECK DAM PROP. CONCRETE BOX CULVERT 250mmØ SDR35 PVC.

B REFER TO DETAIL REM S 1/2 FOR WILD LIFE CORRIDOR


CROSSING & DRAINAGE REFER 2. REFER TO SSD-G.4 AND G.5 FOR STORM

9.15m-GAS
ON SHEET D1.

9.73m-GAS
B 18611 TO SHEET ST1-D1. SEWER TRENCH DETAIL.
B
32 Avenue 3. ALL ABANDONED MHs AND CBs LEFT IN
PLACE SHALL BE FILLED WITH COMPACTED
FOR CONTINUATION SEE ST1-2

FOR CONTINUATION SEE ST1-4


GRANULAR SUBBASE AFTER ALL

0
0+04
ABANDONED CONNECTIONS HAVE BEEN
MATCHLINE STA: 2+000

MATCHLINE STA: 2+300


FILLED WITH CONCRETE SACKS. RIMS AND
CONCRETE LIST TO BE REMOVED TO A
2+000 2+100 2+200 2+300 MINIMUM OF 1.0m BELOW FINISHED GRADE.
STM EX. 114DP GAS

D
EX. 114DP GAS STM D8b 4. CONTRACTOR TO EXPOSE AND VERIFY ALL
D8c EXISTING UTILITY CROSSINGS AND TIE-IN
LOCATIONS AND NOTIFY THE CONTRACT
ADMINISTRATOR OF ANY CONFLICTS OR

0
EX. 375Ø CP STM. DISCREPANCIES PRIOR TO CONSTRUCTION.

0+02
EX. 450Ø CP STM.
GAS MAIN AND HYDRANT LEAD CROSSINGS
48.66
MAY REQUIRE REGRADING.
389.56 48.66

INSTALL SUMP MANHOLE WITH 5. CONTRACTOR TO REPAIR AND REPLACE

4.18m-STM
3.59m-STM

23.84m-ROW
23.70m-ROW

OPEN BOTTOM AND PLACE ANY DAMAGE TO OTHER UTILITIES DURING


300mm THICK 75mm CLEAR THE STORM MAIN INSTALLATION.
CRUSH ROCK WRAPPED IN
GEOTEXTILE FILTER FABRIC. 6. REFER TO TYPICAL DITCH SECTION ON
EX. 300mmØ CULVERT EX. 114DP GAS

0
SHEET D1.

0+00
TO REMAIN. CROSSING (EX. PROP. 375mm SDR35 PVC
DEPTH 1.0m AS PER STM TO BE TIED INTO NEW
WILD CORRIDOR/DRAINAGE 7. REFER TO CB LEAD DETAIL ON SHEET D1.
CITY SURVEYED)
CULVERT.
8. NEW STANDARD STORM SEWER MANHOLE.
INSTALL LANGLEY CONCRETE TYPE I CONTRACTOR TO REMOVE PROP. LANGLEY CONCRETE TYPE II INLET REFER TO MMCD STD. DWG S1 & S2 (TYP).
NEW BIKE FRIENDLY INSTALL NEW 1050mmØ 18600 REMOVE SECTION OF EX. 18640
INLET STRUCTURE (OR APPROVED CBs AND CONCRETE STRUCTURE (OR APPROVED EQUIVALENT)
CATCHBASIN PER SSD-D9. TERMINAL MANHOLE ON 375mmØ STORM BETWEEN
EQUIVALENT) c/w GRILLAGE AND SANDBAG LEADS TO BE 3126 W 1/2 A LOWER THE GRATE BY 25mm AS
W 1/2 4 NEW TERMINAL MANHOLE
c/w GRILLAGE E 1/2HANDRAIL
AND 4 (TYP).
EX. 375mmØ STORM.
HANDRAIL (TYP). INLET LOCATION TO ABANDONED (FILL IN LIGHT CONTRACT ADMINISTRATOR TO CONFIRM
BE DETERMINED BY THE CONTRACT CONCRETE SLURRY) (TYP)
PER MMCD STD DWG S11 (TYP.) AND MANHOLE D8b.
LOCATION OF INLET IN THE FIELD.
KEY NOTES
ADMINISTRATOR. CONNECTED TO CONTRACTOR TO SWALE THE EXISTING
GROUND TOWARDS INLET AS REQUIRED. A.
B INSTALL 1.0m WIDE x 200mm THICK CLASS 10 RIP
STORM SEWER WITH 300mmØ PVC
CONNECT TO STORM SEWER WITH 300mmØ RAP C/W UNDERLYING COCOMAT FROM THE
PIPE AT MIN. 1.0% SLOPE
PVC PIPE AT MIN. 1.0% SLOPE OUTFALL TO THE BOTTOM OF THE PROP. DITCH.

STM STM
D8c D8b
21 21 25 25

C/W 600mm SUMP


RIM: 21.44

RIM: 21.85
1050mm

1050mm
20 20 24 24
PROP. CL PROFILE

19 19 23 23

18 18 22 22
CONNECT EX.
375mmØ STM
PROP. CL PROFILE TO MH D8b.
EX. GROUND PROFILE
17 EX. GROUND PROFILE 17 21 21
EX. GROUND PROFILE
ALONG NORTH DITCH
3.6% EX. 375mmØ STM ON
16 EX. GROUND OF 16 20 SOUTHSIDE OF 32 AVE 20
NORTH DITCH

REMOVE SECTION OF EX.


375mmØ STM BETWEEN
15 1.9% 15 19 MH D8b AND D8c. 19
PROP. BOTTOM
OF NORTH DITCH
PROP. CHECK
PROP. CONCRETE BOX
14 2.3%
DAM (TYP) 14 18 CULVERT FOR WILD LIFE
18
2.1%
CORRIDOR CROSSING &
DRAINAGE REFER TO
PROP. BOTTOM SHEET ST1-D1.
13 13 17 OF NORTH DITCH 17
2.7%

PROP. 8.22m-375mmØ SDR35 PVC STM. @ 10.10%


12 16

19.400 NW
18.570 SE
PROP. STM DATA

EX. 375mmØ EX. 300mmØ


EX. STM DATA STM. @ 4.06% STM. @ 7.36%

ISSUED FOR TENDER

2+234.49

2+241.69
2+020

2+040

2+060

2+080

2+100

2+120

2+140

2+160

2+180

2+200

2+220

2+240

2+260

2+280
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

STORM SEWER
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS ST1-3
PROP. 1200mmØ STORM SEWER
MANHOLE WITH TYPE 1
ADJUSTABLE HEIGHT FRAME
AND COVERS. REFER TO MMCD
STD DWG S1 & S2 AND SSD-S.2.2
INSTALL MIN. 5m LONG, 450mm
THICK CLASS 25 RIP RAP C/W
NATIVE SUBSTRATE MATERIAL CONNECT WALL DRAIN TO PROTECT EXISTING CONTRACTOR TO REMOVE
CONTRACTOR TO REMOVE EX. STORM SEWER
AND ROCK WEIR DOWNSTREAM. THE PROPOSED STORM HYDRO POLES DURING REMOVE HEADWALL, MH, LBs AND CONCRETE
AS REQUIRED TO LOWER THE
MAIN WITH 150mm SOLID STORM SEWER AND STORM PIPE AND SANDBAG LEADS AND
ROAD. REPLACE WITH NEW
PVC SDR35 PIPE (TYP) CONSTRUCTION (TYP). DISPOSE OF OFFSITE. DISPOSE OF OFFSITE (TYP)
600Ø CONC. STM AS SHOWN.
INSTALL PRO-ECO-LITE HEADWALL
(OR APPROVED EQUIVALENT) STM

EX. 88DP GAS


HW89

INSTALL SUMP MANHOLE WITH OPEN


BOTTOM AND PLACE 300mm THICK 0

6.99m-GAS
9.01m-GAS
75mm CLEAR CRUSH ROCK WRAPPED 18793
IN GEOTEXTILE FILTER FABRIC. STM
D09 STM
STM D10
32 Avenue
8.0m

D8a
FOR CONTINUATION SEE R1-3

EX. TEL DUCTS


EX. 600Ø PVC STM.
MATCHLINE STA: 2+300

PROP. 55.00m-600Ø CONC. C76 CLASS IV STM. PROP. 57.84m-600Ø CONC. C76 CLASS IV STM.
D D D

7.0m
D EX. 600Ø PVC STM.
2+300 2+400 2+500 2+600

M.
EX. 114DP GAS EX. 114DP GAS

C ST
EX. 300Ø DI WAT.
STM

Ø PV
D08 EX EX EX

EX. 350Ø DI WAT.


D126

00

EX. TEL DUCTS


D128 D129

EX. 3
EX. 300Ø CP STM. EX. 300Ø PVC STM.
EX. 300Ø PVC STM. EX. 250Ø CP STM.

48.65 8.0m
4.18m-STM

EX. 60DP GAS


23.84m-ROW

193.61

7.33m-STM
27.28m-ROW

188 Street
EX. CB TO BE NEW BIKE FRIENDLY EX. CB TO BE EX. CB TO BE
REMOVED AND LEAD CATCHBASIN PER SSD-D9. REMOVED AND LEAD REMOVED AND LEAD A 3177 3188 A
TO BE CAPPED (TYP) LOWER THE GRATE BY 25mm AS TO BE CAPPED (TYP) TO BE CAPPED (TYP)
INSTALL LANGLEY CONCRETE TYPE I CONTRACTOR TO REMOVE CONNECT WALL DRAIN TO PER MMCD STD DWG S11 (TYP.)
INLET STRUCTURE (OR APPROVED CBs AND CONCRETE THE EX. STORM MAIN WITH
18660
EQUIVALENT) c/w GRILLAGE AND SANDBAG LEADS TO BE18676 150mm SOLID PVC SDR35
HANDRAIL (TYP). W 1/2 LOCATION
INLET 5 TO ABANDONED (FILL IN LIGHT
E 1/2 5 PIPE (TYP)
BE DETERMINED BY THE CONTRACT CONCRETE SLURRY) (TYP)
ADMINISTRATOR. CONNECTED TO
STORM SEWER WITH 300mmØ PVC
PIPE AT MIN. 1.0% SLOPE

STM STM EX
STM EX GENERAL DRAINAGE NOTES STM STM
D08 D09 D10 D129 HW89 D08
33 33 40 40 46 D127 46 1. SINGLE CB LEADS SHALL BE 38
200mmØ SDR35 38
PVC AND DOUBLE CB LEADS SHALL BE

RIM: 44.45
RIM: 33.99

RIM: 40.43

RIM: 33.99
RIM: 45.17
1200mm
RIM: 43.87
1200mm

1200mm

1350mm

1200mm
250mmØ SDR35 PVC.

1350mm
STM
D8a
2. REFER TO SSD-G.4 AND G.5 FOR STORM
32 32 39 39 45 45 37 37
SEWER TRENCH DETAIL.

C/W 600mm SUMP


EX. GROUND PROFILE

RIM: 31.50

1200mm
3. ALL ABANDONED MHs AND CBs LEFT IN
PLACE SHALL BE FILLED WITH COMPACTED
31 31 38 38 44 44 GRANULAR SUBBASE AFTER36 ALL 36
ABANDONED CONNECTIONS HAVE BEEN
FILLED WITH CONCRETE SACKS. RIMS AND
FINISHED GROUND CONCRETE LIST TO BE REMOVED TO A
PROFILE ALONG PROP. MINIMUM OF 1.0m BELOW FINISHED GRADE.
30 STORM SEWER ALIGNMENT 30 37 37 43 43 35 35
4. CONTRACTOR TO EXPOSE AND VERIFY ALL
PROP. CL PROFILE EXISTING UTILITY CROSSINGS AND TIE-IN
LOCATIONS AND NOTIFY THE CONTRACT
ADMINISTRATOR OF ANY CONFLICTS OR
29 29 36 36 42 42 34
DISCREPANCIES PRIOR TO CONSTRUCTION. 34
GAS MAIN AND HYDRANT LEAD CROSSINGS
MAY REQUIRE REGRADING.

5. CONTRACTOR TO REPAIR AND REPLACE


28 28 35 35 41 41 33 33
ANY DAMAGE TO OTHER UTILITIES DURING
THE STORM MAIN INSTALLATION.

6. REFER TO TYPICAL DITCH SECTION ON


27 27 34 34 40 40 SHEET D1. 32 32
7. REFER TO CB LEAD DETAIL ON SHEET D1.

8. NEW STANDARD STORM SEWER MANHOLE.


26 26 33 33 39 39 31& S2 (TYP).
REFER TO MMCD STD. DWG S1 31

INSTALL MIN. 5m LONG, 450mm


THICK CLASS 25 RIP RAP C/W
25 25 32 32 38 38 NATIVE SUBSTRATE30 MATERIAL 30
AND ROCK WEIR DOWNSTREAM.

24 24 31 31 37 37 29 29

PROP. 55.00m-600mm
Q5 = 0.160 cms C76 CLASS IV STM. @ 13.12%
23 23 30 30 36 36 28 Q100 = 0.346 cms 28
QCAP = 2.240 cms
PROP. 13.33m-600mmØ CONC.
Q5 = 0.160 cms Q5 = 0.157 cms
C76 CLASS IV STM. @ 8.25%
Q100 = 0.346 cms Q100 = 0.340 cms
QCAP = 2.240 cms QCAP = 1.670 cms PROP. 5.00m-600mmØ CONC.
22 29 35 C76 CLASS IV STM. @ 3.00% 27
30.700 NW

30.700 NW
29.150 NW
29.000 SE

29.600 SE
38.416 W

42.597 W
31.200 E

38.466 E

31.200 E
PROP. 55.00m-600mmØ CONC. PROP. 57.84m-600mmØ CONC.
PROP. STM DATA C76 CLASS IV STM. @ 13.12% C76 CLASS IV STM. @ 7.14%
42.380 NW

42.887 W

43.060 W
42.470 E

42.887 E

43.060 E
EX. 600mmØ EX. 600mmØ EX. 600mmØ
EX. STM DATA STM. @ 0.87% STM. @ 0.87% STM. @ 0.47%

ISSUED FOR TENDER

0+030.207

0+043.538
0+025.21
2+384.77

2+439.78

2+482.92

2+497.62

2+531.04

2+551.04
2+320

2+340

2+360

2+380

2+400

2+420

2+460

2+480

2+500

2+520

2+540

0+020

0+040
STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

STORM SEWER
32 AVENUE WIDENING (184 ST - 188 ST) 32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS ST1-4
1.5H:1V DAYLIGHT
PROTECT TO EX. GROUND
EX. TREE. (TYP)
GENERAL DRAINAGE NOTES
1. SINGLE CB LEADS SHALL BE 200mmØ SDR35

0
0+06
PVC AND DOUBLE CB LEADS SHALL BE
PROP. CONCRETE BOX 250mmØ SDR35 PVC.
REM S 1/2 CULVERT FOR WILD LIFE
CORRIDOR CROSSING 2. REFER TO SSD-G.4 AND G.5 FOR STORM

9.15m-GAS
18611 REFER TO SHEET ST1-D1 SEWER TRENCH DETAIL.
32 Avenue 3. ALL ABANDONED MHs AND CBs LEFT IN
PLACE SHALL BE FILLED WITH COMPACTED

FOR CONTINUATION SEE ST1-2

FOR CONTINUATION SEE ST1-4


GRANULAR SUBBASE AFTER ALL

0
0+04
MATCHLINE STA: 2+000 ABANDONED CONNECTIONS HAVE BEEN

MATCHLINE STA: 2+300


FILLED WITH CONCRETE SACKS. RIMS AND
CONCRETE LIST TO BE REMOVED TO A
2+200 2+300 MINIMUM OF 1.0m BELOW FINISHED GRADE.
STM EX. 114DP GAS

D
STM D8b 4. CONTRACTOR TO EXPOSE AND VERIFY ALL
D8c EXISTING UTILITY CROSSINGS AND TIE-IN
LOCATIONS AND NOTIFY THE CONTRACT
ADMINISTRATOR OF ANY CONFLICTS OR

0
EX. 375Ø CP STM. DISCREPANCIES PRIOR TO CONSTRUCTION.

0+02
GAS MAIN AND HYDRANT LEAD CROSSINGS
48.66
MAY REQUIRE REGRADING.
48.66

5. CONTRACTOR TO REPAIR AND REPLACE

4.18m-STM
23.84m-ROW
ANY DAMAGE TO OTHER UTILITIES DURING
THE STORM MAIN INSTALLATION.

6. REFER TO TYPICAL DITCH SECTION ON


EX. 300mmØ CULVERT

0
SHEET D1.

0+00
TO REMAIN.
7. REFER TO CB LEAD DETAIL ON SHEET D1.

8. NEW STANDARD STORM SEWER MANHOLE.


CONNECT WALL DRAIN TO PROP. LANGLEY CONCRETE TYPE II INLET REFER TO MMCD STD. DWG S1 & S2 (TYP).
NEW BIKE FRIENDLY 18600 18640
THE PROPOSED STORM STRUCTURE (OR APPROVED EQUIVALENT)
CATCHBASIN PER SSD-D9.
3126 W 1/2 A LOWER THE GRATE BY 25mm AS
W 1/2 4 MAIN WITH 150mm SOLID E 1/2 4 AND HANDRAIL (TYP).
c/w GRILLAGE
PVC SDR35 PIPE (TYP) CONTRACT ADMINISTRATOR TO CONFIRM
PER MMCD STD DWG S11 (TYP.)
LOCATION OF INLET IN THE FIELD.
CONTRACTOR TO SWALE THE EXISTING
GROUND TOWARDS INLET AS REQUIRED.
CONNECT TO STORM SEWER WITH 300mmØ
PVC PIPE AT MIN. 1.0% SLOPE

EX STM
D122 D8b
24 24
RIM: 18.10

RIM: 21.85
1200mm

1050mm
23 23

PROP. WILDLIFE
22 CROSSING. SEE SHEET 22
ST1-D1 FOR DETAILS

21 21

20 20

19 19

18 18

17 17

16 16

PROP. 8.22m-375mmØ SDR35 PVC STM. @ 10.10%


15
19.400 NW
18.570 SE

PROP. STM DATA


21.410 W

21.664 W
16.000 W

21.440 E
16.030 E

EX. 450mmØ EX. 375mmØ EX. 300mmØ


EX. STM DATA STM. @ 1.58% STM. @ 4.06% STM. @ 7.36%

ISSUED FOR TENDER


2+145.52

2+234.49

2+241.69

2+277.96
2+140

2+160

2+180

2+200

2+220

2+240

2+260

STATION

CITY OF SURREY 0 H 1:500 20m


1717-058-11
0 V 1:50 2m

STORM SEWER
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS ST1-5
RE
INSTALL 1829mm W x 1219mm H CONCRETE BOX EX. OVERHEAD WIRES TO BE

M
CULVERT (C/W 600mm W x 400mm H CONCRETE RETAINED AND PROTECTED
BENCH) OR APPROVED EQUIVALENT. INSTALL DURING CONSTRUCTION
AS PER MANUFACTURER'S RECOMMENDED ACTIVITIES
INSTALLATION PROCEDURE. INSTALL PROPEX
4553 OR APPROVED EQUIVALENT NON-WOVEN
GENERAL NOTES
GEOTEXTILE OVER SUBGRADE PRIOR TO

S
PLACING BOX CULVERT 1. ANY EXISTING SIGNS TEMPORARILY REMOVED DURING
CONSTRUCTION WILL BE REINSTATED AS DIRECTED BY THE
CONTRACT ADMINISTRATOR.

1
2. CONTRACTOR TO PROTECT EXISTING GAS AS REQUIRED TO
COMPLETE ALL CULVERT REPLACEMENT WORKS. ALL FORTIS
PERMITS AND COORDINATION WILL BE THE RESPONSIBILITY OF

/
THE CONTRACTOR.

2
3. THE CONTRACTOR IS TO MAINTAIN A COMPLETE SET OF CIVIL
DRAWINGS MARKED IN RED TO RECORD THE CONSTRUCTED
SEAL SOUTH END OF LOCATION OF ALL UTILITIES ON THIS PROJECT. THIS MARKED UP
CULVERT WITH 6mm STEEL SET MUST BE AVAILABLE ONSITE FOR THE ENGINEER OR CITY TO
PLATE AND TO BE BURIED FOR REVIEW AT ALL TIMES. UPON COMPLETION OF EACH UTILITY AND
FUTURE CONNECTION AGAIN UPON COMPLETION OF THE CIVIL WORK, A MARKED-UP SET
IS TO BE SUBMITTED TO R.F.BINNIE FOR THEIR RECORDS.
INSTALL MIN. 5m LONG, 600mm WIDE
WILDLIFE BENCH WITHIN THE DITCH 3.1 ADDITIONALLY, THE CONTRACTOR SHALL PROVIDE FIELD SURVEY
TO PROVIDE ASSESS TO THE PICKUP DURING THE COURSE OF CONSTRUCTION TO DOCUMENT
0+000 0+020 0+040 CORRIDOR WITHIN THE CULVERT. 0+060 RECORD INFORMATION ON ALL UNDERGROUND INSTALLATIONS
D D D D D OF MAINS, SERVICE CONNECTIONS, CHAMBERS, MANHOLES,
APPURTENANCES, STRUCTURES AND FURNISHINGS. THE
CONTRACTOR WILL BE CONTRACTUALLY REQUIRED TO SURVEY
VERTICAL AND HORIZONTAL OF THE INSTALLATION OF
INSTALL MIN. 5m LONG, 450mm UNDERGROUND PROPOSED UTILITIES (STORM, SANITARY,
THICK CLASS 25 RIP RAP C/W WATER). A RECORD DRAWING TOPOGRAPHICAL SURVEY SHOULD
NATIVE SUBSTRATE MATERIAL. BE COMPLETED AFTER CONSTRUCTION TO PICK UP ALL SURFACE
FEATURES
PROP. 375mmØ SDR35 PVC

M
ST
STM TO BE TIED INTO NEW

D
C
WILD CORRIDOR CULVERT.

GAS
PV
Ø
m

4DP
m
3 75

11
P.
BOX CULVERT GENERAL NOTES

EX.
PR
1. CULVERT TO BE INSTALLED WITH RUBBER GASKETED BOX
CULVERT (FACTORY INSTALLED PRE-LUBRICATED SUPER-SEAL
GASKET) MEETING ASTM C1677-11a SPECIFICATION OR APPROVED

STM
EQUIVALENT
EX. 114DP GAS


2. REMOVAL OF EXISTING CULVERT AND INSTALLATION OF THE

375m
REPLACEMENT BOX CULVERT SECTIONS TO OCCUR IN ISOLATION
OF FLOWING WATER. OWNER'S ENVIRONMENTAL MONITOR TO
EX.
COMPLETE A FISH SALVAGE IN ADVANCE OF CONSTRUCTION.

3. CONSTRUCTION TO BE ISOLATED FROM THE ADJACENT


WATERCOURSE TO PREVENT SEDIMENT FROM ENTERING.
SEDIMENT CONTAINMENT METHODS AND ISOLATION
PROCEDURES TO BE REVIEWED AND APPROVED BY THE
ENVIRONMENTAL MONITOR PRIOR TO PROCEEDING.
22 22
PROP. 19mm MINUS
4. THE PROJECT WORK AREA IS ADJACENT TO FISHERIES SENSITIVE
BASE GRAVEL OVER
HABITAT. CONTRACTOR'S ACTIVITIES TO COMPLY WITH THE
CULVERT
REQUIREMENTS OF THE ENVIRONMENTAL MONITOR, THE
CONSTRUCTION MITIGATION PLAN PREPARED FOR THIS
PROJECT, AND ALL APPLICABLE REGULATORY REQUIREMENTS OF
THE DFO AND BC MINISTRY OF FORESTS, LANDS, NATURAL
RESOURCE OPERATIONS AND RURAL DEVELOPMENT

5. BACKFILL OF PROPOSED CULVERT TO BE IMPORTED,


WELL-GRADED PIT RUN GRAVEL IN ACCORDANCE WITH MMCD.

AS CITY SURVEYED
BACKFILL TO BE PLACED IN LIFTS NOT EXCEEDING 300mm IN

~1.0m EX. COVER


21 EX. 114DP GAS TO 21 THICKNESS AND COMPACTED WITH VIBRATORY EQUIPMENT TO
BE PROTECTED. NOT LESS THAN 95% MPD. NATIVE EXCAVATION MAY BE SUITABLE
~1.5m MIN.

FOR BACKFILL AS RECOMMENDED IN GEOWEST ENGINEERING


COVER

GEOTECHNICAL REPORT.

6. IF SOFT SUBGRADE UNDER THE PROPOSED CULVERT IS


ENCOUNTERED, GEOWEST ENGINEERING SHALL BE CONTACTED
TO DETERMINE THE REMEDIATION TO BE FOLLOWED BY THE
CONTRACTOR.

0.3m
MIN.
20 20

1829mm
SEAL SOUTH END OF
CULVERT WITH 6mm STEEL
PLATE AND TO BE BURIED FOR
FUTURE CONNECTION 150mm W x 400mm H
150mm W x 400mm H
CONCRETE WALL
CONCRETE WALL

1219mm
19 19

PROP. 375mmØ
0.40m

SDR35 PVC STM


PROP. 375mmØ PVC STM TO BE TIED
INTO NEW WILD CORRIDOR CULVERT. 200mm THICK 75mm CLEAR
CRUSH ROCK C/W NATIVE
SUBSTRATE MATERIAL.

CONC. BOX CULVERT SECTION


18 18 NTS
18.500 N

18.370 S
PROP. 25.00m - 1829mm W x 1219mm H
CONC. BOX CULVERT @ 0.52%
10 - 2.5m LENGTHs

INSTALL MIN. 5m LONG, 450mm


0+020

0+040

PROP. 150mm-THICK 19mm THICK CLASS 25 RIP RAP C/W


MINUS BASE GRAVEL NATIVE SUBSTRATE MATERIAL.

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

DETAIL
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVE & 184 ST
A 2023-12-14 ISSUED FOR TENDER CS ST1-D1
32 AVENUE
32 Avenue

REFER TO GEOTECHNICAL
WALL DESIGN FOR GEOGRID
LENGTH AND SPACING
1+960
14.0
1+920
1+840 1+880
13.0

13.0

12.0

12.0

0+000 0+100 11.0

11.0

10.0
APPROXIMATE EXTENTS
INSTALL 1.2m HIGH PROPOSED SOUTH RETAINING WALL OF GEOGRIDS (TYP). TO
HANDRAIL AS PER 10.0
(MAX. EXPOSED HEIGHT 1.4m) BE CONFIRMED PRIOR
3126 MMCD C14 AT TOP REFER TO DESIGN BY GEOWEST TO CONSTRUCTION
W 1/2 A OF RETAINING WALL.

15 15

14 PROP. SOUTH 14
GUTTERLINE PROFILE
TOP OF PROP. SOUTH
RETAINING WALL
13 13

12 12

11 11

PROPOSED SOUTH RETAINING WALL


EX. GROUND AT PROP. (MAX. EXPOSED HEIGHT 1.4m). REFER
SOUTH RETAINING WALL TO DESIGN BY GEOWEST
10 10

9 9

8 8
11.681
11.143

11.322

11.502

11.860

12.040

12.219

12.399

12.578

12.758

12.937

13.116

13.296

13.475
OP. TOP OF WALL
10.661

11.581
10.562

10.786

10.990

11.262

11.682

11.479

11.403

11.599

11.880

12.235

12.586
11.214
1+820

1+830

1+840

1+850

1+860

1+870

1+880

1+890

1+900

1+910

1+920

1+930

1+940

1+950
ISSUED FOR TENDER
CITY OF SURREY 0 H 1:250 10m
1717-058-11
0 V 1:50 2m

RETAINING WALL
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS RW1-1A
REFER TO GEOTECHNICAL
WALL DESIGN FOR GEOGRID
LENGTH AND SPACING

32 AVENUE

2+280 2+320 2+360 2+400

0+100 0+140

48.66
48.65

PROPOSED SOUTH RETAINING WALL INSTALL 1.2m


(MAX. EXPOSED HEIGHT 1.6m). HIGH HANDRAIL
REFER TO DESIGN BY GEOWEST AS PER MMCD INSTALL 1.2m HIGH PROPOSED SOUTH RETAINING WALL
18640 C14 AT TOP OF REMOVE HANDRAIL AS PER (MAX. EXPOSED HEIGHT 1.1m).
18660 18676
E 1/2 4 RETAINING WALL. EX. TREE MMCD C14 AT TOP REFER TO DESIGN BY GEOWEST
W 1/2 5 E 1/2 5 OF RETAINING WALL.

36 APPROXIMATE EXTENTS APPROXIMATE EXTENTS 36


OF GEOGRIDS (TYP). TO OF GEOGRIDS (TYP). TO
BE CONFIRMED PRIOR BE CONFIRMED PRIOR
18660 DRIVEWAY PROFILE TO CONSTRUCTION TO CONSTRUCTION
35 28 28 35

34 27 27 34

33 26 26 PROPOSED SOUTH RETAINING 33


WALL (MAX. 1.1m) REFER TO
PROP. SOUTH DESIGN BY GEOWEST
GUTTERLINE PROFILE
32 25 25 37 37 32
TOP OF PROP. SOUTH
RETAINING WALL
18676 EAST DRIVEWAY PROFILE

31 24 24 36 36 31

30 25 35 35 30

18640 DRIVEWAY PROFILE


29 24 EX. GROUND AT 34 34 29
BOTTOM OF WALL

PROPOSED SOUTH RETAINING WALL


(MAX. EXPOSED HEIGHT 1.6m).
28 23 REFER TO DESIGN BY GEOWEST 33 33 28

27 22 34 34 27

26 21 33 33 26

25 32 32 25

24 31 31 24

18676 WEST DRIVEWAY PROFILE


23 30 30 23

22 22
26.631
23.047

23.522

24.150

24.877

25.704

27.659

28.786

29.966

31.146

32.325

33.505
PROP. TOP OF WALL
29.511
22.697

23.029

23.649

24.344

25.192

26.240

26.618

27.427

28.428

31.139

32.695

34.754

36.336
EX. GROUND

ISSUED FOR TENDER


2+270

2+280

2+290

2+300

2+310

2+320

2+330

2+340

2+350

2+360

2+370

2+380

2+390

2+400

2+410

2+420
STATION

CITY OF SURREY 0 H 1:250 10m


1717-058-11
0 V 1:50 2m

RETAINING WALL
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS RW1-1
4V:3H CONSTRUCTION BACKSLOPE REFER
TO GEOTECHNICAL WALL DESIGN
(DWG. GA20-1239-02 (01 TO 03)) BY
GEOWEST ENGINEERING DATED 2022.06.15 APPROXIMATE EXTENTS
OF GEOGRIDS (TYP). TO PROPOSED NORTH RETAINING WALL 1
18611 BE CONFIRMED PRIOR (MAX. EXPOSED HEIGHT 1.4m). 18793 APPROX. EXTENTS
INSTALL 1.2m HIGH HANDRAIL
TO CONSTRUCTION REFER TO DESIGN BY GEOWEST OF BACK SLOPE
AS PER MMCD C14 AT TOP OF
RETAINING WALL. FOR WALL (TYP)

32 AVENUE

EX. 114DP GAS


2+400 2+440 2+480 2+520

0+140

REM A
3177
193.61

46 46

45 45

REFER TO GEOTECHNICAL
WALL DESIGN FOR GEOGRID
44 44 4V:3H CONSTRUCTION LENGTH AND SPACING
BACKSLOPE REFER TO
EX. GROUND AT TOP GEOTECHNICAL WALL
OF RETAINING WALL DESIGN

43 43

42 42

PROP. NORTH
GUTTERLINE PROFILE
41 41

BOTTOM OF PROP. NORTH


RETAINING WALL

40 40

PROPOSED NORTH RETAINING WALL


39 (MAX. EXPOSED HEIGHT 1.4m). 39
REFER TO DESIGN BY GEOWEST

38 38

37 37

36 36

35 35

34 34
38.761

43.941
33.329

37.512

39.693

40.653

41.575

42.448

44.279

44.746

44.606
43.187

EX. GROUND
36.103

37.356

38.534

39.675

40.717

41.658

42.499

43.242

43.890

44.430

PROP. TOP OF WALL

ISSUED FOR TENDER


2+390

2+400

2+410

2+420

2+430

2+440

2+450

2+460

2+470

2+480

2+490

2+500

2+510

2+520
STATION

CITY OF SURREY 0 H 1:250 10m


1717-058-11
0 V 1:50 2m

RETAINING WALL
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS RW1-2
General Notes
1. ALL PAVEMENT MARKINGS TO BE PER THE
CURRENT EDITION OF THE MANUAL FOR
UNIFORM TRAFFIC CONTROL DEVICES FOR
CANADA & CITY OF SURREY'S PAVEMENT
MARKING MANUAL (NOV. 1997).

2. REFER TO SSD-PM1 FOR PAVEMENT


MARKINGS WIDTHS, SPACING AND
COLORS.

3. NEW PAVEMENT MARKINGS SHALL BE


THERMOPLASTIC.

0 3301
4. EXISTING SIGNS NOT PERTINENT TO NEW
ROAD SHALL BE RETURNED TO SURREY
WORKS YARD.

FOR CONTINUATION SEE BELOW


MATCHLINE STA: 1+700
Legend:

P
RB-51B

231.24

RB-55B

18282
18224
8 7

Key Notes
A.
A NEW STOP BAR OR CROSSWALK LINES AS PER
SSD-PM-2

B.
B NEW WHITE SOLID LINE AS PER SSD-PM-1

C.
C NEW WHITE BROKEN (6:3) LANE LINE AS PER
SSD-PM-1

D.
D NEW SIMULTANEOUS SOLID AND BROKEN (3:6)
YELLOW LINE AS PER SSD-PM-1
WA-036L RB-55B
E.
E ARROWS AS PER SSD-PM-11

F.
F ERADICATE EX. STRIPES, STOP BARS AND
ARROWS

G. NEW 0.6m WIDE WHITE HATCH LINE AT 3m


G
RELOCATE EX.
SPACING PER SSD-PM-4
TRUCK ROUTE &
NO STOPPING EX. "NO STOPPING" EX. "NO STOPPING"
SIGN RB-55B A 3237 WA-036R REM
SIGN TO BE S 1/2 SIGN TO BE H.
H YELLOW HATCH AS PER SSD-PM-4
RELOCATE EX. RELOCATED RELOCATED
TRUCK ROUTE & 18611 I.J SOLID SINGLE YELLOW LINE AS PER SSD-PM-1
EX. "NO STOPPING"
SIGN TO BE NO STOPPING
RELOCATED SIGN TO SL POLE
A
FOR CONTINUATION SEE ABOVE

FOR CONTINUATION SEE PM1-4


MATCHLINE STA: 1+700

MATCHLINE STA: 2+000


C A C
B
B C
A
C
A

389.56

REMOVE EX. BIKE RELOCATE EX.


ROUTE/NO TRUCK ROUTE
STOPPING SIGN. SIGN TO SL POLE
MAXIMUM

RB-55B RB-55B RB-61 RB-55B


60 RB-55B

RB-1
1 3181 EX. SIGN TO BE
RELOCATED
EX. SIGN TO BE EX. SIGN TO BE EX. SIGN TO BE W 1/2 A
79.91

3126 ON SL POLE EX. SIGN TO BE ON SL POLE


RELOCATED RELOCATED RELOCATED
RELOCATED
TO LIGHT POST TO LIGHT POST TO LIGHT POST
ON SL POLE

ISSUED FOR TENDER


CITY OF SURREY 0 1:500 20m
1717-058-11
PAVEMENT MARKINGS
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS PM1-3
ON SL POLE

RELOCATE
"ENTERING FARM
RB-14R AREA" SIGN RB-55B

RB-55B RB-55B REM S 1/2 RB-14R

18611

FOR CONTINUATION SEE BELOW


FOR CONTINUATION SEE PM1-3
MATCHLINE STA: 2+000

MATCHLINE STA: 2+320


C

C
General Notes
1. ALL PAVEMENT MARKINGS TO BE PER THE
CURRENT EDITION OF THE MANUAL FOR
48.66 48.66 UNIFORM TRAFFIC CONTROL DEVICES FOR
389.56
CANADA & CITY OF SURREY'S PAVEMENT
MARKING MANUAL (NOV. 1997).

2. REFER TO SSD-PM1 FOR PAVEMENT


MARKINGS WIDTHS, SPACING AND
COLORS.

HERITAGE MARKER 3. NEW PAVEMENT MARKINGS SHALL BE


RB-55B RESTRICTED RB-55B THERMOPLASTIC.
VISIBILTY Brown
Road 4. EXISTING SIGNS NOT PERTINENT TO NEW
18600 18640 CITY OF SURREY
ROAD SHALL BE RETURNED TO SURREY
WORKS YARD.
3126 W 1/2 A W 1/2 4 E 1/2 4
EX. SIGN TO BE
RELOCATED
EX. SIGN TO BE
RELOCATED
Legend:

P
EX. SIGNS TO
RB-51B
BE RELOCATED REMOVE EX.
STOP SIGN

STOP
12 %
RA-1 EX. RIGHT- RB-55B
WA-021A TURN-ONLY SIGNS
EX. SIGNS TO USE LOWER EX. " TREE SEED TO BE REMOVED.
BE REMOVED. GEAR CENTRE" SIGN TO ERADICATE EX.
WA-036L BE RELOCATED TO
WA-021S RIGHT-TURN ARROWS (3).
PRIVATE
RB-14R RB-55B RB-14R RB-14R RB-55B PROPERTY.
0 REMOVE EX. BIKE
ROUTE SIGN.
18793

8.0m
Key Notes
FOR CONTINUATION SEE ABOVE

A.
A NEW STOP BAR OR CROSSWALK LINES AS PER
SSD-PM-2
MATCHLINE STA: 2+320

A A
B.
B NEW WHITE SOLID LINE AS PER SSD-PM-1

7.0m
C
C.
C NEW WHITE BROKEN (6:3) LANE LINE AS PER
SSD-PM-1
C B
A D.
D NEW SIMULTANEOUS SOLID AND BROKEN (3:6)
YELLOW LINE AS PER SSD-PM-1
A
E.
E ARROWS AS PER SSD-PM-11
48.65 8.0m

F.
F ERADICATE EX. STRIPES, STOP BARS AND
193.61 ARROWS

G. NEW 0.6m WIDE WHITE HATCH LINE AT 3m


G
SPACING PER SSD-PM-4

H.
H YELLOW HATCH AS PER SSD-PM-4

RB-55B RB-55B
A 3177 3188 A I.J SOLID SINGLE YELLOW LINE AS PER SSD-PM-1
RB-55B

18660 18676
W 1/2 5 E 1/2 5

ISSUED FOR TENDER


CITY OF SURREY 0 1:500 20m
1717-058-11
PAVEMENT MARKINGS
32 AVENUE WIDENING (184 ST - 188 ST)
32 AVENUE
A 2023-12-14 ISSUED FOR TENDER CS PM1-4
11.0 11.0

10.0 10.0

9.0 9.0

8.5 8.5

11.0

10.0 11.0

9.0 10.0

8.5 9.5

11.0 11.0

10.0 10.0

9.0 9.0

8.5 8.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-1
12.0

12.0

11.0

11.0

10.0

10.0

9.0

12.0 12.0
8.5 9.0

11.0 11.0

10.0 10.0

9.0 9.0

8.5 8.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-2
13.0

13.0

12.0

12.0

11.0

11.0

10.0

10.0

9.0 9.5

13.0

12.0

12.0

11.0

11.0

10.0

10.0

9.0 9.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-3
14.0

13.0

13.0

12.0

12.0

11.0

11.0

10.0 10.5

14.0

13.0

13.0

12.0

12.0

11.0

11.0

10.0

9.5 10.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-4
14.0

14.0

13.0

13.0

12.0

12.0

11.0

10.5 11.0

14.0

14.0

13.0

13.0

12.0

12.0

11.0

10.5 11.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-5
15.0

15.0

14.0

14.0

13.0

13.0

12.0

12.0

11.0
15.0 11.5

15.0

14.0

14.0

13.0

13.0

12.0

12.0

11.0 11.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-6
16.0

15.0 16.0

14.0 15.0

13.0 14.0

12.0
16.0 13.0

16.0

15.0

15.0

14.0

14.0

13.0

13.0

12.0 12.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-7
17.0

17.0

16.0

16.0

15.0

15.0

17.0
14.0

17.0
13.5 14.0

16.0

16.0

15.0

15.0

14.0

14.0

13.0 13.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-8
18.0

18.0

17.0

17.0

16.0

16.0

15.0

15.0

14.0
18.0 14.5

18.0

17.0

17.0

16.0

16.0

15.0

15.0

14.0 14.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-9
20.0

19.0

19.0

18.0

18.0

17.0

17.0

16.0

15.5
19.0 16.0

18.0 19.0

17.0 18.0

16.0 17.0

15.0 16.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-10
21.0 21.0

20.0 20.0

19.0 19.0

18.0 18.0

17.0 17.0
21.0

20.0

20.0

19.0

19.0

18.0

18.0

17.0

16.5 17.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-11
22.0

21.0 23.0

20.0 22.0

19.0 21.0

18.0
22.0 20.0

17.5 19.5

21.0

20.0 22.0

19.0 21.0

18.0 20.0

17.5 19.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-12
24.0 24.0

23.0 23.0

22.0 22.0

21.0 21.0

20.5 20.5

24.0

23.0

23.0

22.0

22.0

21.0

21.0

20.0 20.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-13
25.0 27.0

24.0 26.0

23.0 25.0

22.0 24.0

25.0

24.0 26.0

23.0 25.0

22.0 24.0

21.0 23.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-14
29.0

28.0

27.0

26.0

25.5

31.0

28.0 30.0

27.0 29.0

26.0 28.0

25.0 27.0

24.5 26.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-15
32.0 33.0

31.0 32.0

30.0 31.0

29.0 30.0

28.0 29.0

27.5 28.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-16
34.0

33.0 36.0

32.0 35.0

31.0 34.0

30.0 33.0

29.0 32.0

28.5 31.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-17
42.0

40.0 41.0

39.0 40.0

38.0 39.0

37.0 38.0

36.0 37.0

35.0 36.0

34.0 35.0

33.0 34.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-18
42.0 43.0

41.0 42.0

40.0 41.0

39.0 40.0

38.0 39.0

37.0 38.0

36.0 37.0

35.0 36.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-19
44.0

43.0 44.0

42.0 43.0

41.0 42.0

40.0 41.0

39.0 40.0

38.0 39.0

37.0 38.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-20
45.0

45.0

44.0

44.0

43.0

43.0

42.0

42.0

41.0

41.0

40.0

40.0

39.0

38.5 39.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-21
45.0

45.0

44.0

44.0

43.0

43.0

42.0

42.0

41.0

41.0

40.0 40.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-22
46.0

45.0 45.0

44.0 44.0

43.0 43.0

42.0 42.0

41.0 41.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-23
46.0

46.0

45.0

45.0

44.0

44.0

43.0

43.0

42.0 42.5

46.0

46.0

45.0

45.0

44.0

44.0

43.0

43.0

42.0

41.5 42.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-24
46.0

46.0

45.0

45.0

44.0

44.0

43.0

42.5 43.0

46.0 46.0

45.0 45.0

44.0 44.0

43.0 43.0

42.5 42.5

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-25
46.0

45.0

46.0

45.0

ISSUED FOR TENDER


CITY OF SURREY 0 H 1:100 4m
1717-058-11
0 V 1:20 0.8m

SECTIONS
32 AVENUE WIDENING (184 ST - 188 ST)
XS1-26