Professional Documents
Culture Documents
An Endo Revolution: With Only 3 Instruments!
An Endo Revolution: With Only 3 Instruments!
An Endo Revolution: With Only 3 Instruments!
An endo revolution
3
W e i n v e n t , Y o u s u
Revo-S
Contents
Revo-S Revolutionary
12
The MicRo-Mega +
18
19
Only 3 instruments
www.revo-s.com
3
InGeT or Classics system
revolutionary!
The Micro-Mega
The instrument works in a cyclic way (3c concept): 1) cutting 2) clearance (debris elimination) 3) cleaning
R2
R3
R1
Asymmetrical section
Symmetrical section
www.revo-s.com
SU, asymmetrical section, recapitulates the action of the first two instruments
ADvAntAges
n Optimal cleaning. n Adapted active length. n The extended cutting part in the coronal region increases instrument flexibility. n Optimal upward removal of dentine debris. 6
InGeT
instruments
SC2
(Shaper & Cleaner 2) N25 .04 25 or 29 mm
www.revo-s.com
SU, asymmetrical section, recapitulates the action of the first two instruments
Classics
instruments
SC2
(Shaper & Cleaner 2) N25 .04 25 or 29 mm
www.revo-s.com
1
SC 2
2/3 WL
2
WL
Canal finishing
SU
WL
10
Initial penetration n The first step comprises an initial penetration of the canal, using a
conventional stainless steel hand instrument (usually a K file N10 - MMC n10 L21 mm) which provides information about the canal anatomy complementary to that obtained by the pre-operative X-rays. The use of ENDOFLARE is recommended (The MICRO-MEGA +). The instruments should be removed frequently from the canal and cleaned, using a compress in order to eliminate the dentine debris.
n n
operative dynamics n Revo-S instruments should be used with a rotation speed ranging
between 250 and 400 rpm. l Use SC1 with slow and unique downward movement in a free progression and without pressure. l Use SC2 with a progressive 3 wave movement. l Use SU with a slow and unique downward movement in a free progression and without pressure. Then check apical patency and if necessary, perform an upward circumferential filing movement.
irrigation n The canal should be thoroughly irrigated using sodium hypochlorite (2.5
to 5%) between the use of each instrument. The use of a chelating colloid (gel) (MM-EDTA Cream recommended) is advised for instrument lubrication and dentine debris removal (The MICRO-MEGA +).
11
www.revo-s.com
Apical finishing
For a successful canal preparation, apical finishing is essential: MICRO-MEGA offers an optional adapted solution with specific instruments: AS30, AS35, AS40. These instruments enable efficient widening of the apical preparation to .06 taper respecting the preparation performed with SC1, SC2 and SU. This finishing enables an improved flow of the irrigating solution promoting efficient disinfection and facilitated obturation.
AS30 WL
ADvAntAges
n Shaping down to the working length: more accurate finishing of the apical 1/3. n Efficient disinfection: the irrigating solution penetrates to the apical 1/3. n Optimal cleaning. n The instruments dedicated to the apical area are tapered at .06. n Asymmetrical cross section. n The extended helical machining up to the coronal region enables a continuous bending of the instrument.
AS35
WL
AS40 WL
12
InGeT
instruments
Apical finishing
AS30
(Apical Shaper 30) N30 .06 25 or 29 mm
AS35
(Apical Shaper 35) N35 .06 25 or 29 mm
AS40
(Apical Shaper 40) N40 .06 25 or 29 mm
13
www.revo-s.com
AS30 WL
AS35
WL
AS40 WL
14
Classics
Apical finishing
instruments
AS30
(Apical Shaper 30) N30 .06 25 or 29 mm
AS35
(Apical Shaper 35) N35 .06 25 or 29 mm
AS40
(Apical Shaper 40) N40 .06 25 or 29 mm
15
www.revo-s.com
AS30 WL
AS30 WL
AS35 WL
AS30 WL
AS35 WL
AS40 WL
16
n If necessary and according to the root canal anatomy, use the AS30, AS35
and AS40 to enlarge the apical region.
17
www.revo-s.com
The MICRo-MEGA +
MM-SealTM is a high quality, epoxy resin-based, paste/paste sealer for permanent filling of root canals using gutta percha. Its outstanding chemical and physical properties guarantee an excellent root canal seal. Eugenol-free, biocompatible and radiopaque, it can be used for all types of gutta percha fillings.
n Pastinject
For an optimal application of the sealing materials, calcium hydroxide and paste.
n HERofill
Herofill is a third generation obturation method, based on the principle of a solid plastic core coated with thermoplastic gutta percha. This method offers outstanding accuracy and safety.
18
InGeT
APEX Pointer +
19
www.micro-mega.com
www.micro-mega.com www.revo-s.com
MICRo-MegA 5-12, rue du Tunnel F-25006 BESAnon cedex FRAnCE
JC.AUG n www.jcauge.com
MICRo-MegA International Distribution Tel.: +33 (0)3 81 54 42 34 Fax: +33 (0)3 81 54 42 39 mmid@micro-mega.com
MICRO-MEGA reserves the right to modify the characteristics of its instruments without notice. Pictures non contractual.