ANNEXURE B2 Sewer Long Sections

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 39

NOTES AND SPECIFICATIONS

GENERAL
69/315 139/317
RE/1

ANDEON X37
1. ALL MATERIAL AND WORKMANSHIP MUST
COMPLY WITH THE REQUIREMENTS OF THE
148/317

4
LATEST RELEVANT SABS REQUIREMENTS.
5

3
2. ALL DIMENSIONS ARE IN MILLIMETERS.
162
(UNLESS OTHERWISE SPECIFIED).
3. DO NOT SCALE FROM THESE DRAWINGS.
FOOT OF MAGALIE
SBERG RANGE

4. ALL DIMENSIONS MUST BE CHECKED AND


GE
RG RAN
ALIESBE
OF MAG
FOOT
147/317
FO
OT
OF

APPROVED ON SITE.
MA
GA
LIE

e road widening
SBER
G RA
NG
E

5. ALL CONSTRUCTION TO BE DONE IN


ACCORDANCE WITH THE STANDARD

10m servitude - futur


MAG
AL
IESB
ER
G RA
NG
E

SPECIFICATIONS FOR MUNICIPAL CIVIL


0.0 9.0
OF

ENGINEERING WORKS, THIRD EDITION 2005 AND


OT
FO

.0
3/1

134 133 7.0 .0 0


133 1336 1335.1334.01333.0 32.0 31.0 0.0

38
THE STANDARD COT DETAIL DRAWINGS.

13
13 13 133 9.0 6. THESE DRAWINGS MUST BE READ IN
132

7.0
132 8.0
NIEMANDT STR CONJUNCTION WITH THE STANDARD

132
EET 25m

EAGLE STREET
DRAWINGS.(IF APPLICABLE).
5m
7. THIS DRAWING MUST BE READ IN CONJUNCTION
T2
EE WITH THE STANDARD SPECIFICATIONS FOR
TR QUARRY 2/1

600Ø SW
D TS
AN
IEM MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

25m
N
4.

600Ø SW
138/317
97/317

8. THE SIGNATURE OR INITIALS ON THIS DRAWING,


V

Niemandt Street OF ANY DIRECTOR OF THE WATER AND


SANITATION DEPARTMENT, IN NO WAY
LOCALITY PLAN 420 REMOVES ANY RESPONSIBILITY WHATSOEVER

450Ø SW
CRECHE

FROM THE CONSULTANT.


6

9. THE CONSULTANT REMAINS RESPONSIBLE TO

Renet Avenue
ENSURE THAT ALL THE GUIDELINES, STANDARD
KINGFISHER STR
EET 20m 341
PARK
DRAWINGS, STANDARDS AND SPECIFICATIONS

450Ø SW
1080
SECONDARY SCHOOL

KINGFISHER STR OF WATER AND SANITATION DEPARTMENT HAVE


EET 20m
9

RE/8
BEEN MET AND ARE COMPLIED WITH.
10. FINAL POSITION OF SERVICES TO BE
DETERMINED ON SITE.

600Ø SW
11. ALL SEWER LONG HOUSE CONNECTIONS TO BE

EAGLE STREET

RENET AVENUE
163

CONSTRUCTED AS COT STANDARD DRAWING


10
7515-S209
RE/11

25m

25m
.0 LEGEND
69/315
1313 312.0 1.0 1310.0 SEWER
1 131 0.0
340
PRIMARY SCHOOL

131

450Ø SW
7/230

1309.0 13
NEW MANHOLE
12

101/315

1308.0 CE / LH

Renet Avenue
450Ø SW
0.0
28/230
SWAN STREET

Alfred Boyes Avenue


20m

1 1307 EXISTING MANHOLE


8/230

13 SWAN STREET
. 0

450Ø SW
20m
14 NEW CCTV INSPECTION
1306.0
15

EXIST. LINE INSPECTED BY CCTV


10/230
11/230
27/230
12/230

600Ø SW
70/317

NEW SEWER LINE


13/230

1305.0

EAGLE STREET

600Ø SW
EXISTING SEWER LINE

EAGLE STREET
9/230
17

1304.0
16

HOUSE CONNECTION

Gra

32m
72/315

vel
R
1303.0

oad
26/230

SUBURB BOUNDARY

32m
18

04100823 PIPE NUMBER


1302.0

600Ø SW
19

Alfred Boyes Avenue


14/230 DIRECTION OF FLOW
22/230
21/230
18/230
17/230

75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS


Class PE100 PN 6, SDR26

WP,DPT:1.20m
25/230

SLEEVE Ø TYPE CLASS

WP,DPT:1.20m

Renet Avenue
BM1
CROSSCUT
WP,DPT:1.90m

WP,DPT:1.72m
450Ø SWm
DPT:0.25
400Ø SW WP,DPT:1.90m
500Ø SW WP,DPT:1.80m
WP,DPT:1.80m
Z:1299.542

112

0m
T:1.4
WP,DPT:1.70m

-WP,DP

UK,DPT:1.00m
WP,DPT:1.65m

RAND
WP,DPT:1.65m
450Ø SW

8.0
WP,DPT:1.70m

EC,DPT:0.80m

WP,DPT:0.60m
600Ø SW

WP,DPT:0.60m
29999.0
230 450Ø SW

EC,DPT:0.70m
WP,DPT:1.80m GS,DPT:1.40m

GS,DPT:1.40m
450Ø SW

DPT:0.40m
500Ø SW
FO,DPT:0.70m 500Ø SW WP,DPT:1.16m GS,DPT:1.40m

WP,DPT:1.20m
UK,DPT:0.60m
500Ø SW WP,DPT:1.20m

.0 1299.0
500Ø SW WP,DPT:1.17m
FO,DPT:0.70m
WP,DPT:1.17m WP,DPT:1.00m

30
FO,DPT:0.60m FO MH FO,DPT:0.60m FO,DPT:0.60m

DPT:0.60m
500Ø .40m

500Ø SW
22

DPT:0
SW

0m
T:1.4
-WP,DP
DPT:0.500Ø SW

FO,DPT:0.60m
0

RAND
30m

0
21

1 .0 .9 .

1301.0
20

299
307 .0 112.0
1299

RAND-WP,DPT:1.20m
1 301
WELL 4

FO,DPT:0.60m
OVERHEAD
POWERLINE
24/230 OVERHEAD WELL 4

.0 1
POWERLINE

PEG1
129
CONCRETE
CHAMBER

6
18.89m wide GRAVEL

Z:1305.740 SMH1 Right of Way ROAD

Servitude

130
WATER PIPELINE
MARKER

8.0
WATER PIPELINE
MARKER

Servitude A13256
SMH2
/1998 V

WELL 1

DPT:0.25m
450Ø SW
CONCRETE
CHAMBER 18.89m wide
WELL 1
Right of Way
Servitude

5.0
Beverley Street
WELL 2

FO,DPT:0.80m
RAND-WP,DPT:1.20m
.0
WELL 2
GRAVE
WELL 3 L ROAD

16/230 15/230
WELL 3
23/230 20/230 19/230

99
0 0.0
FENCE

13 130
V

12
4.0
Beverley Street
1297

RAND-WP,DPT:1.10m
V

30

EDGE TAR
.0

.0
V

1 .0

FO,DPT:0.80m
EAGLE STREET 32m

98 Holtman Avenue
03
232/317

9.0

12
13 .0 129

L ROAD
Mack Avenue
02

GRAVE

FENCE
.0 1296
1297
15/315

13
23
26

0 .0 27

1301.

RAND-WP,DPT:1.40m
30
VALVE
CONCRETE
CHAMBER 31
SMH3
VALVE
33
RE/317
36

FO,DPT:0.70m

Alfred Boyes Avenue


0.0
37

296.0
41

30
43

1 1 1295

RAND-WP,DPT:1.40m
9.0 .0
FENCE

HERE

FO,DPT:0.80m
9
12 .0
1295
SMH4
CONCRETE
CHAMBER
SMH5

CONCRETE
CHAMBER

EDGE TAR

RAND-WP,DPT:1.40m
e - A3915/1979
1294

FO,DPT:0.80m
.0

WALL
231/317

10m wide servitud


1/34

Alfred Boyes Avenue


600Ø
SW

600Ø
SW

24

FO,DPT:0.80m
236/317

RAND-WP,DPT:1.30m
GS,DPT:1.40m FO MH 28
FO,DPT:0.80m
FO,DPT:0.60m
29

FO,DPT:0.70m
WP,DPT:1.40m

GS,DPT:1.40m
RAND-WP,DPT:2.00m
RAND-WP,DPT:2.00m
PT:1.4
0m 32
RAND-WP,DPT:1.60m WP,D
WP,DPT:0.80m
RAND-WP,DPT:1.60m
WP,DPT:0.70m

SW,D
35

PT:0.
60m
FENCE
38

Lilian Street CONCRETE


39

EAGLE STREET 25m


CHAMBER 42
SMH6
44

EC,DPT:0.40m
SMH7

138

itude - Wetland
159

Tienie Street RE/34

RAND-WP,DPT:1.50m

RAND-WP,DPT:0.90m
GRAVEL ROAD

Mack Avenue
V

139

Tienie Street WATER PIPELINE

WATER PIPELINE
MARKER V

GRAVEL ROAD MARKER

Tienie Street

142 Tienie Street


Tienie Street

RAND-WP,DPT:1.20m
RAND-WP,DPT:1.20m
143 152

Holtman Avenue
50m wide serv
GRAVEL ROAD

RAND-WP,DPT:1.40m
151

RAND-WP,DPT:1.40m
146
147

FO,DPT:0.70m
123
140 RE/151/317

Ho

RAND-WP,DPT:1.25m

RAND-WP,DPT:1.40m
158

rn 13 OSTRICH STREET 25m 53

FO,DPT:0.85m
1.0.0

sn 56
0

160

02
RAND-WP,DPT:2.80m
57
1300.0

e 1/60
1133001

RE/60
.

kR
01

.0
61
.0

RAND-WP,DPT:1.30m
RAND-WP,DPT:1.40m
63

oa
1298.0

124
66
13

1299

209/317
1297.0
d
157
294/317
71

.0

1295.00
141 73
76

1295.
6

FO,DPT:0.80m
4.0
129
153

OPEN CHANNEL
129

RAND-WP,DPT:1.70m
RAND-WP,DPT:1.40m
Mack Avenue

129
EAGLE STREET 25m

.0
.0

11229
4.0

94
FENCE

5.0
3

FO,DPT:0.70m
156 125

29

.0
1
144

.0
92

RAND-WP,DPT:1.80m
RAND-WP,DPT:1.40m
91
12
1290.0

12

FO,DPT:0.80m
Ken
FO,DPT:0.60m

ne th S
150 SW MH
GRAVEL ROAD

CL:1297.87m SW MH

FENCE
145 CL:1297.38m

Alfred Boyes Avenue


IL:1296.56m IL:1296.37m

500Ø
t SW
reet
900Ø SW 900Ø SW
SW MH
CL:1296.43m SW MH

500Ø .50m
DPT:0
IL:1293.93m SW MH

SW
CL:1295.15m CL:1294.93m
149 IL:1293.25m IL:1293.03m
900Ø SW 900Ø SW
900Ø SW DPT:1.00m 600Ø SW,DPT:1.30m
DPT:0.95m 1050Ø SW
1050Ø SW<DPT:0.85m
SW

DPT:0.85m

RAND-WP,DPT:1.40m
RAND-WP,DPT:1.40m
0m

450Ø

155
SW
PT:0.9

SW,DPT:1.20m
KI
450Ø

FO,DPT:0.50m
SW,D

CL:1295.64m KI SW,DPT:1.40m
IL:1294.99m

m
DPT:0. SW
FO MH

20m

T:1.20
CL:1294.07m

550Ø
550Ø SW
.00m

EC,DPT:1.20m
UK,DP
DPT:0.55m
WP,DPT:1.40m

IL:1293.42m
DPT:1

54
PEG5

UK,DPT:0.60m
550Ø SW
DPT:0.65m 550Ø SW
SW MH DPT:0.75m 800Ø SW

0m
FO,DPT:0.50m DPT:0.35m
Z:1289.887

PT:1.3
FO MH
CL:1296.07m
PROPOSED

T:1.55m
FO,DPT:1.00m

SW,D
55

UK,DPT:1.20m
IL:1293.94m FO MH
SP MH

SW,DP

EC,DPT:1.00m
UK,DPT:1.15m FO,DPT:0.40m

FO,DPT:0.40m
400Ø SP

WP,DPT:1.00m
800Ø SW
CL:1290.54m

FO,DPT:0.80m
WP,DPT:1.90m UK,DPT:1.20m FO,DPT:0.60m DPT:0.50m
154

DPT:400Ø SW
FO,DPT:0.40m
WP,DPT:1.90m

0m

0.70m
IL:1286.79m
CONNECTION

DPT:0.8 SW
UK,DPT:1.00m

PT:1.3
700Ø SW
58

0m
UK,DPT:1.20m

FO,DPT:0.40m

700Ø
WP,DPT:1.40m
SW,D
EC,DPT:0.60m
WP,DPT:1.20m DPT:0.50m
SP MH UK,DPT:1.20m 400Ø SP EC,DPT:0.80m UK,DPT:1.20m

GS,DPT:1.90m
WP,DPT:1.40m
FO,DPT:0.60m WP,DPT:1.40m UK,DPT:1.20m EC,DPT:0.70m FO MH
CL:1295.0m FO MH UK,DPT:1.20m 700Ø SW

90m

DPT:1. SW
FO,DPT:0.50m
59

00m
80m
DPT:0.65m
IL:1292.40m
POINT 2 PROPOSED

PT:0.
EC,DPT:0.90m

400Ø
PT:0.
WP,DPT:1.30m FO,DPT:0.60m UK,DPT:1.20m

EC,D
UK,D
WP,DPT:1.40m WP,DPT:1.80m EC,DPT:0.90m FO,DPT:0.80m
FO,DPT:0.70m

FO,DPT:0.40m
EC,DPT:0.90m FO,DPT:0.40m 400Ø SP
148 SP MH WP,DPT:1.90m UK,DPT:1.10m EC,DPT:0.70m FO MH
62

FO,DPT:0.60m

EC,DPT:0.60m
EC,DPT:0.90m

CONNECTION

FO,DPT:0.60m
FO MH WP,DPT:1.40m UK,DPT:1.10m
CL:1294.18m FO,DPT:0.35m

DPT:0.90SW
m
SW MH

Johan Du Toit Avenue


700Ø
FO MH FO,DPT:0.40m WP,DPT:1.60m EC,DPT:0.90m
IL:1291.42m FO MH
UK,DPT:1.20m BURIED

FENCE

FO,DPT:0.60m
FO MH

GS,DPT:2.40m
FO,DPT:0.60m

WP,DPT:0.90m

RAND-WP,DPT:1.40m
400Ø SP EC,DPT:0.90m
WP,DPT:1.40m UK,DPT:1.30m
64

RAND-WP,DPT:1.40m
Holtman Avenue

RAND-WP,DPT:1.80m
POINT 1
UK,DPT:1.60m
T:1.30m FO,DPT:0.60m WP,DPT:1.30m EC,DPT:0.90m

1050Ø SW
FO MH
709

1600Ø SP

DPT:1.20m
SW,DP FO MH FO,DPT:0.60m 400Ø SP

EC,DPT:0.90m
WP,DPT:1.20m EC,DPT:0.90m

0m
PT:0.6
FO MH FO,DPT:0.60m WP,DPT:1.50m 400Ø SP UK,DPT:1.50m
65

SW,D
FO,DPT:0.60m FO,DPT:0.40m
FO,DPT:0.60m WP,DPT:1.60m FO MH 400Ø SP
FO MH EC,DPT:0.60m
FO,DPT:0.60m UK,DPT:1.50m
WP,DPT:1.40m
UK,DPT:1.00m
WP,DPT:1.20m 74
SP MH

FO,DPT:0.50m
FO,DPT:1.00m FO,DPT:0.60m 68
CL:1290.07m

m
T:0.90
FO MH
IL:1286.47m

EC,DP
FO MH

EC,DP
SP MH

WP,DPT:0.80m
SP MH

T:0.80
DPT:1.30m
CL:1289.57m

m
WP,DPT:1.20m IL:1285.77m CL:1289.49m 292/317
FO MH IL:1285.39m

RAND-WP,DPT:1.80m
RAND-WP,DPT:1.00m
FO,DPT:0.60m

FO,DPT:0.70m
FO,DPT:0.60m FO,DPT:0.80m

75

1600Ø SP

GS,DPT:1.70m
EC,DPT:0.90m
16/315 SP MH
CL:1291.39m
IL:1288.898m

WP,DPT:0.70m

RAND-WP,DPT:1.80m

RAND-WP,DPT:1.90m
GS,DPT:1.60m

FO,DPT:0.50m
Kenneth Street VALVE

VALVE
FENCE
V

Kenneth Street
V
V
Kenneth Street
153/317 V

Kenneth Street 710 PARK


1/74

Kenneth Street
127
1860

115

134 116
137 298/317

133 1570 1569 1568


104 1567 1566 1565 1564 1563

1861
1760 PARK

1571 1572 1575 1576


136 83 1587

1586 1573 1574


1577
90 1602

91
1585 1582
128 1581 1578
92 1265 1601
1264 1263 1262
1584 1583
1266 1580 1579
1600

1267

118
1603 1604
1268 1607 1608
105 1611 1612
117 1536

1626 1605
1269 1606 1609 1610
1613 1537

1625
1622 1621
1270 1618 1617 1614
1534
700
1624 1623
281/317 84 1271 1620 1619 1616

Fred Messenger Avenue


1615
135 1535

1272
ue

129

1273 1627 1628 1631 1632 1635 1636


e Aven

1651

1274 1650 1629 1630 1633 1634


132 1637
1666

1275 1649 1646 1645 1642 1641 1638


108 1665
94
1276 1648
119 1647 1644 1643 1640 1639
1664
Verreyn

120 701
1277

RE/132/317 1278
1281 1282 1285 1286 1289 1290
93 1508 1509
85 1279 1280 1283 1284 1287 1288
1291

154/317 1304 1303 1300 1299 1507


1296 1295 1506
1292
2993
131 1305
2992 1302 1301
1298 1297 1294 1293
2994 2988
2991
1306
284/317
704
2995 2990 2987
1483
2996 2989 1870 109 1307

Baird Avenue
2984 1673
2997 1674 1677
169/317 1679 1681 1682 1482
2986 1308
2998 2983
306/317 95
2999 1696 1676
3022 2596 122 1675 1678
2985 1680
2980 1309 1761 1683 1481

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
1 OF 1
PO BOX 1022 Tel: 012 372 3708 GENERAL SEWER LAYOUT (1 OF 1)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
0001
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION DATE WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT CONSULTANT DRAWING NUMBER:
DATE:
NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-01U01 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
MH208

3051

3085
CLASS-400
CLASS-400

63.01 m
160mm∅
m

2899

2922
2884
2861
NOTES AND SPECIFICATIONS

2883.80
CLASS-400
2850
83.93 m

MH207
2879
2878

4
2877
74.91 m
160mm∅/

2880
2876

2882
2881

CLASS-400
3052
GENERAL

69.76 m
3084
160mm∅/
CLASS-400
2921

76.52 m
160mm∅/
1. ALL MATERIAL AND WORKMANSHIP MUST

2860
2851
COMPLY WITH THE REQUIREMENTS OF THE

2900

3053
LATEST RELEVANT SABS REQUIREMENTS.

2905
2906
2909

2907

2902
2903
2910

2908

2904

2901

3139
NIEMANDT STREET 2. ALL DIMENSIONS ARE IN MILLIMETERS.

2920
160mm∅/ 160mm∅/ (UNLESS OTHERWISE SPECIFIED).
25m

2852

MH218
CLASS-400 CLASS-400 3. DO NOT SCALE FROM THESE DRAWINGS.

3054
MH215 4. ALL DIMENSIONS MUST BE CHECKED AND

11.99 m
2919
78.87 m APPROVED ON SITE.

MH300
16m
272
85.57 m
272 272 272 5. ALL CONSTRUCTION TO BE DONE IN
8 7 6 5 272 272 272 272 272

2854MH213
4 3 2 271 ACCORDANCE WITH THE STANDARD

3057MH153
1 0

3055
9 271 271 271

2853
272 8 7 271 271 271 SPECIFICATIONS FOR MUNICIPAL CIVIL
9 6 5 4 3 271 271 271 LH24 ENGINEERING WORKS, THIRD EDITION 2005 AND
2 1 0 270

2859
2858

2911

2918
2855

2912
2857
2856

2916
270

2914
2913

3056
2915

2917
MH 9 THE STANDARD COT DETAIL DRAWINGS.

3058
20m
273 222 160mm∅/ 8 270 MH252 6. THESE DRAWINGS MUST BE READ IN
0 MH CLASS-400 7 270
247 13 MH25 160mm∅/ 6 270 CONJUNCTION WITH THE STANDARD
m 0 CLASS-400 MH 5 270 DRAWINGS.(IF APPLICABLE).
112.50 m 22 4
279 279 279 1 160mm∅ 7. THIS DRAWING MUST BE READ IN CONJUNCTION
0 1 2 279 279 107.54 m CLASS / 2 WITH THE STANDARD SPECIFICATIONS FOR
3 4 279
5 279 279 279 279 280 280
-400 MH LH2 703 EAGLE STREET 25m MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
6 7 8 9 0 280 280 219
1 280
43.

2 280 51.93 m 4.

CLASS-400
278 3
CL 0mm∅

1
4 5

62.17 m
9

CL 0mm∅
8. THE SIGNATURE OR INITIALS ON THIS DRAWING,

160mm∅/
96

16

.
A

94

16
S

A
278 CR OF ANY DIRECTOR OF THE WATER AND
m

278
MH232

278
S-4 /

278 19.

E
4 278

m
6 5 278 278 EC 270

S-4 /
3 2 277 277 70 SANITATION DEPARTMENT, IN NO WAY
278 LH5 1 0 277 HE 276 2
00

A
8 LH4 MH 9 8 7 mm∅2/776
160 277 277 m REMOVES ANY RESPONSIBILITY WHATSOEVER

00
277 280 4

2001

2991
5

2702

2699

MH242
227

MH240 2698
2700

2763

2761

2759
4

2758
277

2760
20m
2697
G
6

2762
MH

2757

2990
MH 3 FROM THE CONSULTANT.

MH22
CLASS-400

MH227
2 2220
246 2 160mm∅/ 160mm∅/ 160mm∅/ 160mm∅/

2703
787 10.62 m 9. THE CONSULTANT REMAINS RESPONSIBLE TO

L
16 277 701

-4 /
AS3 mm∅
1
CL 0mm∅
ENSURE THAT ALL THE GUIDELINES, STANDARD

00
CLASS-400

2756
CLASS-400

MH241
E
CLASS-400 CLASS-400
25.

99.91 m

MH2S02
276

5
16

MH226
16

LH2
CL 0mm∅

AS 13 10.15 CL 0m2m7∅70 5 DRAWINGS, STANDARDS AND SPECIFICATIONS


CL 0mm∅

C2992
46.
S-4 /

0
MH243
27

16
16

CL 0mm∅
m m
A

MHL20
AS 160mm∅/ m OF WATER AND SANITATION DEPARTMENT HAVE

16m
AS 16 14.94 m 46.82 m 40.62 m
S-4 / 2 270

16m
S

82
00 S-4 / 84.20 m
m

34. 0

16
A

19.70 m
m
S-4 /

4.8
0

TR
00 MH BEEN MET AND ARE COMPLIED WITH.

S
276

MH244
00 76 CLASS-400

m
71. 00 34.

S -4 /
m 238 282 MH 9 6
00

54 10. FINAL POSITION OF SERVICES TO BE


282 8 52 m 223 MH237

00
m

2704
273 276 DETERMINED ON SITE.

EE
7 36.00 m

2993
6 269 285

2755
MH219
282 282 8 9 5 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
9

2765
273 16 MH

2808
2764

2811
6

2766
276

2767
MH SP CONSTRUCTED AS PER COT STANDARD

2810
2809

2812
7 283 m 240

T
282 0 266 O RT 7 DRAWING 7515-S209
RE

2705
273 16 5 CR S/ 269 285
8

2994
2
283 6

2754
8 CL 0mm∅

CLASS-400
282 1 382 EA
5

49.12 m
AS 4 LEGEND

160mm∅/
TIO
273 S-4 / 283

2813
m
9 2 N

2768
282 13 C 160m 269

2807

2841
00

2706

2840
285

2842
90.

58.
274 3 7 SEWER

MH228
40.

160m S-400

CLASS-400
CL 0mm∅

3m
70 283 mLA m∅ 7

CL 0mm∅
0

95
160mm∅/

2753
36
m 282 3 / 280

82.63 m
/
16
SS

29∅
62
A

m∅/
16
A
2 NEW MANHOLE
KIN 7

51.9

2996160mm
S
274 -40

CLASS-400 MH223
283 16 CLASS-400

m
S -4 /
72. 0

S
1

S-4 /
282 4 m

CRECHE
73 285

CLA
280

2707

2839
2769
GF 1

00
m 8 8 CE / LH

2814
284 MH229

00
274 283

16m
5 2 58.36 m 160mm∅/

2752
16m
2 MH 282 MH 20
ISH

2806
MH
25 0 283 24 m EXISTING MANHOLE

MH231
274 1 281 6 1 285 CLASS-400

2
3 13 280 9
ENRG

78.
30
KI 9 MH230

34.54 m
70/
2708

27∅
m 283

CL 0mm∅
284 9 NEW CCTV INSPECTION

2771 160mm
274 7 47.93 m

87
281

MH221
16

2997
A
1

2815

2751
4

2838
FS 8 MH

S
m
276

RECREATION
IS EXIST. LINE INSPECTED BY CCTV
TH R 228

S-4 /
274 283 281 3
281

SPORTS/
8

MH
0

2709
ER 5 16

00
7 20
ESET CL 0mm∅ 284 m NEW SEWER LINE

229
274 AS 281 283 0 290

2750

2998
S-4 /

2816
TR E2E 6 276

2837
6 9
47.
7
CL 0mm∅
00 281 2 EXISTING SEWER LINE

m
274 89. 281 5
93

0T m20 MH22

MH204
16

2710
1
A
7 40 5

10.15
S
m

m HOUSE CONNECTION
S-4

2772
274 291 290

CLASS-400
3825
m 276

2817
6

2836

2749
281 1

84.
8

2999
1
00

226
16

∅/
MH

CL
4 m SUBURB BOUNDARY
300 MH

20
AS
m
S
04100823 PIPE NUMBER

-40
DIRECTION OF FLOW

0
1340 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH222 - MH93 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


(MH222 - MH252) CROSSCUT

1335

1330

1325
NGL

SCALES: 1320
Horizontal 1:1000
Vertical 1:200

DATUM 1315.000
MH221

MH241
MH222

MH250

MH219

MH220

MH240

MH242
MH243
MH237

MH244

MH252
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400
220.041

649.861
271.974

463.309
468.057
475.173
291.669

338.493

379.108

511.173

573.346
112.502
0.000

DISTANCE (m)

1322.601
1334.506

1333.659

1332.657

1331.898

1331.217

1329.176

1327.569

1323.739
1323.698
1323.954

1321.139
GROUND LEVEL

1321.741
1332.250

1330.844
1330.764

1329.688
1329.608

1327.943
1327.863

1327.666
1327.586

1326.100
1326.020

1325.414
1325.334

1321.966
1321.886
1321.750
1321.670
1321.590

1320.826
1320.729

1318.484
1318.404

1316.874
PIPE INVERT LEVEL
3.551
3.631
2.257

2.816
2.896

2.969
3.049

3.955
4.035

3.076
3.155

2.155
2.235

2.284
2.364

2.655
2.735
1.872
1.773
1.853
1.957

1.775
DEPTH TO INVERT

1.25% 1.00% 3.21% 1.00% 3.17% 1.49% 4.00% 2.86%


1.00% 2.12% 3.61% 2.00%
1:80.0 1:100.0 1:31.2 1:100.0 1:31.5 1:67.0 1:25.0 1:35.0
1:100.0 1:47.1 1:27.7 1:50.0
SLOPE / LENGTH 112.50m 107.54m 51.93m 19.70m 46.82m 40.62m 84.20m 4.75m
7.12m 36.00m 62.17m 76.52m

Q(l/s) 0.62 0.93 1.02 1.04 1.28 1.32 1.60 1.601.60 3.66 3.68 3.82
DESIGN
V(m/s) 0.5 0.5 0.7 0.5 0.8 0.6 0.9 0.8 0.6 0.9 1.1 0.9
HYDRAULICS Q(l/s) 14.41 12.89 23.08 12.89 22.96 15.74 25.77 21.78
12.89 18.77 24.49 18.22
MAX. (0.7D) 1.1 1.0 1.7 1.0 1.7 1.2 1.9 1.6 1.0 1.4 1.8 1.4
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
1 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (1 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L01 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
160mm∅/
16mCLASS-400
NOTES AND SPECIFICATIONS
MH210 GENERAL
108.70 m 1. ALL MATERIAL AND WORKMANSHIP MUST
COMPLY WITH THE REQUIREMENTS OF THE
2885 2886 2887 2888 2889 2890 2891 LATEST RELEVANT SABS REQUIREMENTS.
2. ALL DIMENSIONS ARE IN MILLIMETERS.

CLASS-400
160mm∅/
(UNLESS OTHERWISE SPECIFIED).

48.00 m
3. DO NOT SCALE FROM THESE DRAWINGS.
2898 2896 2895 2894 2893 2892 4. ALL DIMENSIONS MUST BE CHECKED AND
2897 APPROVED ON SITE.
5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
MH301

160mm∅/ SPECIFICATIONS FOR MUNICIPAL CIVIL


16m CLASS-400 ENGINEERING WORKS, THIRD EDITION 2005 AND

450Ø SW
MH216 THE STANDARD COT DETAIL DRAWINGS.
6. THESE DRAWINGS MUST BE READ IN
83.18 m
CONJUNCTION WITH THE STANDARD
2923 2924 2925 2926 2927 2928 2929 DRAWINGS.(IF APPLICABLE).

CLASS-400
160mm∅/
7. THIS DRAWING MUST BE READ IN CONJUNCTION

36.00 m
450Ø SW

EAGLE STREET 32m WITH THE STANDARD SPECIFICATIONS FOR


450Ø SW

RENET AVENUE 25m


450Ø SW 600Ø SW 600Ø SW

MUNICIPAL CIVIL ENGINEERING WORKS, SERIES


4.
MH253

160mm∅/ 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,


160mm∅/ 160mm∅/
KINGFISHER STREET 20m

MH285
MH283

MH194
MH282
MH235 OF ANY DIRECTOR OF THE WATER AND
CLASS-400 MH234 CLASS-400 MH258 CLASS-400 10m Servitude - future road widening 160mm∅/ 160mm∅/ 250mm∅/ 250mm∅/ SANITATION DEPARTMENT, IN NO WAY
10m Servitude - future road widening
CLASS-400 CLASS-400 CLASS-400 CLASS-400 REMOVES ANY RESPONSIBILITY WHATSOEVER
90.75 m 91.14 m 103.50 m FROM THE CONSULTANT.
3140 3141 3146 3148 3150 3151 87.51 m 89.62 m 81.83 m 87.51 m 9. THE CONSULTANT REMAINS RESPONSIBLE TO

3162
3048 3045 3142 3143 3145 3147 3149

3159

3160
3042

7768
3144

3333
3165
3161

3167
3050 3049 3043

3330
3047

3332
3046 3044

3158

3164

3334
3166
3163

3328

3331

3335
3156

3157

3338
3329

3337
CLASS-400

3339
3336
ENSURE THAT ALL THE GUIDELINES, STANDARD

MH131
160mm∅/ 160mm∅/

29.08 m
160mm∅/
DRAWINGS, STANDARDS AND SPECIFICATIONS
CLASS-400 CLASS-400 OF WATER AND SANITATION DEPARTMENT HAVE

3169
BEEN MET AND ARE COMPLIED WITH.
160mm∅/ 160mm∅/ 160mm∅/ 3152 MH178160mm∅/

3327
13m

MH123
MH281
MH256 MH154 104.69 m 100.32 m 10. FINAL POSITION OF SERVICES TO BE
MH255 16m

13m
MH254 16m CLASS-400 CLASS-400 CLASS-400 160mm∅/ DETERMINED ON SITE.

600Ø SW
CLASS-400
MH180 MH181 CLASS-400 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
96.60 m 84.51 m 86.11 m CONSTRUCTED AS PER COT STANDARD
36.00 m

3170
3276

3277
MH121

3274

3275

3326
3201
3200
3199

3278
100.38 m DRAWING 7515-S209

3273
3198

3420
3419
3279

3412

3416
3195

3417
3413
3090 3092 3190 3191 3192

3418
3189

3421
3091 3093 3193

3414
3088 3153

3415
3086 3087 3089 3094 3187 3188 3194

CLASS-400
3186

160mm∅/
99.30 m
16m LEGEND

CLASS-400
RENET AVENUE 25m

41.92 m
160mm∅/

3171
3196

3325
SEWER

3411
3280
3311
3203

3313
05

3204

3314

3312
3202
3154

MH13276
3207

3272
3212

3460
MH173
3215 3213 3210

3453

3452
3208

34259
3214 3211 3209

3456
3097

3455

3454
3096

3458
3098 3095 NEW MANHOLE

3457
3103 3102 3101 3099 160mm∅/ 160mm∅/

CLASS-400

MH11
3100
160mm∅/

3172

63.98 m
160mm∅/
CLASS-400 CLASS-400

3310

3324
CLASS-400

3461
3281
3206 CE / LH

3410
3197 160mm∅/ CLASS-400
MH261

77.85 m
MH262

160mm∅/
13m
160mm∅/ 160mm∅/ 160mm∅/ LH29 3155 MH172

MH265
5.51 m 63.34 m 48.25 m

CLASS-400
5.51 m
CLASS-400 EXISTING MANHOLE
102.46 m

13m
CLASS-400 CLASS-400

17.20 m
160mm∅/
CLASS-400 13m MH169
MH170

3173
6
1705

3323
MH32

3462
NEW CCTV INSPECTION

CLASS-400
3198

3409
3309

3282
48.01 m

160mm∅/
104.69 m
83.15 m 80.00 m 80.90 m 3156

3233
3232

3234
EXIST. LINE INSPECTED BY CCTV

3235

3236

3237

3238
3231

10m Servitude - future road widening

3478
CLASS-400
3227

3477
3474

3475
3222

3473
3216 3228

3476
3217 3218 3223 3224 3226 3229 3230

3472
3219 3220 3221 3225

3174

3322
37.16 m
160mm∅/

3308

3283
NEW SEWER LINE

3408
3199 MH115

3463
3204

3231
3232 3157
EXISTING SEWER LINE
3270 MH283

3244

3241
3243
MH149

3240
3242
MH278

3239
CLASS-400

3175
MH151

3284
3248

3471
3307

3481

3480
3247

3321

3479
3484
3252 3251 3250 3249 160mm 3245

3482
HOUSE CONNECTION

CLASS-400

3464
3200

80.90 m

3407
∅/ 3246

3483
3256 3255 3254 160mm ∅/
3253 3203

160mm
3257 160mm∅/

CLASS-400

13m
63.34 m
3158

3230

3245
160mm∅/

72.58 m
∅/
CLASS-400 CLASS-400 CLASS-400 SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1320 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH222 - MH93 Class PE100 PN 6, SDR26

(MH253 - MH194) SLEEVE Ø TYPE CLASS


CROSSCUT

1315

1310

1305
NGL

SCALES: 1300
Horizontal 1:1000
Vertical 1:200

DATUM 1295.000
MH253

MH234

MH258

MH235

MH283

MH282

MH194
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 250mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400

1293.511
1034.552

1211.682
1122.065
649.861

740.611
573.346

831.756

935.253
DISTANCE (m)
1318.698

1315.953

1314.263

1313.717

1311.176

1308.614

1306.948
GROUND LEVEL

1309.471
1309.391

1306.021
1305.941

1303.791
1318.404

1316.874
1316.794

1313.769
1313.716

1312.107
1312.027

1311.048
1310.973

1303.909

1302.973
PIPE INVERT LEVEL
2.185
2.237

2.155
2.235

2.669
2.744

2.593
2.673

3.039
3.157
1.905

1.705
1.785
DEPTH TO INVERT

2.00% 3.33% 1.76% 0.95% 1.51% 3.85% 2.27% 1.00%


1:50.0 1:30.0 1:56.7 1:105.7 1:66.1 1:26.0 1:44.1 1:100.0
SLOPE / LENGTH 76.52m 90.75m 91.14m 103.50m 99.30m 87.51m 89.62m 81.83m

Q(l/s) 3.82 3.98 6.39 11.05 11.05 11.05 11.08 24.84


DESIGN
V(m/s) 0.9 1.1 1.0 0.9 1.1 1.6 1.3 1.2
HYDRAULICS Q(l/s) 18.22 23.53 17.12 12.53 15.85 25.29 19.41 42.31
MAX. (0.7D) 1.4 1.8 1.3 0.9 1.2 1.9 1.5 1.3
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
2 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (2 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L02 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
AGLE STREET 32m
10m Servitude - future roa
3417
3335
NOTES AND SPECIFICATIONS

CLASS-400
250mm∅/
87.51 m
3418 GENERAL
3336 1. ALL MATERIAL AND WORKMANSHIP MUST
MH123 COMPLY WITH THE REQUIREMENTS OF THE
13m
LATEST RELEVANT SABS REQUIREMENTS.
3419 3337 2. ALL DIMENSIONS ARE IN MILLIMETERS.
(UNLESS OTHERWISE SPECIFIED).
3. DO NOT SCALE FROM THESE DRAWINGS.
3420 4. ALL DIMENSIONS MUST BE CHECKED AND
3338 APPROVED ON SITE.
5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
3421 SPECIFICATIONS FOR MUNICIPAL CIVIL
3339 ENGINEERING WORKS, THIRD EDITION 2005 AND
MH284 THE STANDARD COT DETAIL DRAWINGS.
CLASS-400
160mm∅/

6. THESE DRAWINGS MUST BE READ IN


94.75 m

3422
3340 CONJUNCTION WITH THE STANDARD
DRAWINGS.(IF APPLICABLE).
7. THIS DRAWING MUST BE READ IN CONJUNCTION
3423 WITH THE STANDARD SPECIFICATIONS FOR
3341
600Ø SW

Holding 22 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES


4.
8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
3424 3342 OF ANY DIRECTOR OF THE WATER AND
SANITATION DEPARTMENT, IN NO WAY
REMOVES ANY RESPONSIBILITY WHATSOEVER
CLASS-400
250mm∅/
88.11 m

FROM THE CONSULTANT.


3425 3343 9. THE CONSULTANT REMAINS RESPONSIBLE TO
ENSURE THAT ALL THE GUIDELINES, STANDARD
MH118 DRAWINGS, STANDARDS AND SPECIFICATIONS
3344 OF WATER AND SANITATION DEPARTMENT HAVE
BEEN MET AND ARE COMPLIED WITH.
13

10. FINAL POSITION OF SERVICES TO BE


.3

MH117
5m

DETERMINED ON SITE.
BM1 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE

0m
299.542

T:1.4
315mm∅/ Z:1

P,DP
CONSTRUCTED AS PER COT STANDARD

UK,DPT:1.00m
1

D-W
22.09 m

315mm∅/

RAN
315mm∅/ MH94 DRAWING 7515-S209
WP,DPT:1.20m

3347 3345 315mm∅/ MH307 CLASS 34 MH308 CLASS 34


3346 200mm∅/ 315mm∅/ MH306 CLASS 34
CLASS 34 MH305 CLASS 34
80.04 m GS,DPT:1.40m GS,DPT:1.40m
LEGEND

WP,DPT:1.20m
CLASS-400

WP,DPT:0.60m
85.01 m

WP,DPT:0.60m

DPT:0.40m
500Ø SW
85.01 m

UK,DPT:0.60m
GS,DPT:1.40m
94.46 m

EC,DPT:0.70m
SEWER

WP,DPT:1.72m
85.01 m
WP,DPT:1.20m

23.75 m
MH95

WP,DPT:1.20m WP,DPT:1.17m
MH119

WP,DPT:1.00m
WP,DPT:1.80m WP,DPT:1.16m FO,DPT:0.60m
WP,DPT:1.65m WP,DPT:1.70m 500Ø SW WP,DPT:1.17m FO,DPT:0.60m

EC,DPT:0.80m
WP,DPT:1.70m WP,DPT:1.65m 450Ø SW 500Ø SW 500Ø SW FO,DPT:0.70m FO MH NEW MANHOLE
SW E T
S T R450ØE
450ØT:SW0.25m

WP,DPT:1.80m 600Ø SW FO,DPT:0.60m


DP

WP,DPT:1.90m WP,DPT:1.90m
WP,DPT:1.80m
BEVERLEY 450Ø SW
FO,DPT:0.70m

DPT:0.60m
500Ø

500Ø SW
SW

DPT

0m
:0.40

T:1.4
500Ø SW
CE / LH

P,DP
D-W
DPT:0500Ø SW

FO,DPT:0.60m

RAN
.30m

EXISTING MANHOLE

NEW CCTV INSPECTION


EXIST. LINE INSPECTED BY CCTV

CLASS 34
315mm∅/
94.39 m
C

RAND-WP,DPT:1.20m
NEW SEWER LINE

EXISTING SEWER LINE

FO,DPT:0.60m
HOUSE CONNECTION

SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1315 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH222 - MH93 Class PE100 PN 6, SDR26

(MH285 - MH94) SLEEVE Ø TYPE CLASS


CROSSCUT

1310

1305

1300
NGL

SCALES: 1295
Horizontal 1:1000
Vertical 1:200

DATUM 1290.000
MH285

MH284

MH305

MH306

MH307

MH308
MH95

MH94
250mmØ 250mmØ 250mmØ 315mmØ
315mmØ 315mmØ
315mmØ 315mmØ 315mmØ
315mmØ 315mmØ
315mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400
CLASS-34 CLASS-400
CLASS-34 CLASS-400
CLASS-34 CLASS-400
CLASS-34 CLASS-400
CLASS-34
1293.511

1554.151
1211.682

1648.612
1381.024

1469.137

1733.626

1818.640

1898.683
1993.069
DISTANCE (m)
1302.401
1305.190

1303.655

1301.668

1301.000

1300.465

1299.923

1299.600
GROUND LEVEL
1303.791

1299.211
1299.131
1302.973
1302.899

1301.807
1301.727

1299.728
1299.636

1298.658
1298.579

1298.154
1298.074

1297.649
1297.569

1296.600
1296.600
1294.743
PIPE INVERT LEVEL
2.291

2.421

2.311
2.391
2.673
2.765

2.456
2.537

2.342

2.274
2.354

3.000
1.848
1.928

DEPTH TO INVERT

1.00% 1.25% 2.27% 0.50% 0.50% 0.50% 0.50% 1.21% 1.97%


1:100.0 1:80.1 1:44.1 1:200.0 1:200.0 1:200.0 1:200.0 1:82.6 1:50.8
SLOPE / LENGTH 81.83m 87.51m 88.11m 85.01m 94.46m 85.01m 85.01m 80.04m 94.39m

Q(l/s) 24.84 25.01 25.15 36.48 36.48 36.48 36.48 36.48 36.48
DESIGN
V(m/s) 1.2 1.3 1.6 1.0 1.0 1.0 1.0 1.0 1.4
HYDRAULICS Q(l/s) 42.31 47.26 63.73 55.54 55.54 55.54 55.54 55.54 86.41
MAX. (0.7D) 1.3 1.5 2.0 1.1 1.1 1.1 1.1 1.1 1.7
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
3 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (3 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________ 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
NOTES AND SPECIFICATIONS
GENERAL
1. ALL MATERIAL AND WORKMANSHIP MUST
COMPLY WITH THE REQUIREMENTS OF THE
LATEST RELEVANT SABS REQUIREMENTS.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
(UNLESS OTHERWISE SPECIFIED).
3. DO NOT SCALE FROM THESE DRAWINGS.
4. ALL DIMENSIONS MUST BE CHECKED AND
APPROVED ON SITE.

CL:1290.54m
WP,DPT:1.40m

SP MH
5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
SPECIFICATIONS FOR MUNICIPAL CIVIL
ENGINEERING WORKS, THIRD EDITION 2005 AND

WP,DPT:0.70m
THE STANDARD COT DETAIL DRAWINGS.
6. THESE DRAWINGS MUST BE READ IN

0m
T:1.4 DP
WP,
RAND-WP,DPT:1.40m
RAND-WP,DPT:1.40m CONJUNCTION WITH THE STANDARD
DRAWINGS.(IF APPLICABLE).
RAND-WP,DPT:1.40m FO,DPT:0.80m RAND-WP,DPT:1.40m

FO MH
RAND-WP,DPT:1.40m RAND-WP,DPT:1.30m FO,DPT:0.80m FO,DPT:0.70m
RAND-WP,DPT:1.40m RAND-WP,DPT:1.80m
RAND-WP,DPT:1.20m RAND-WP,DPT:1.70m
7. THIS DRAWING MUST BE READ IN CONJUNCTION
FO,DPT:0.70m RAND-WP,DPT:0.90m FO,DPT:0.70m FO,DPT:0.85m
FO,DPT:0.80m RAND-WP,DPT:1.25m RAND-WP,DPT:1.40m

315mm∅/
RAND-WP,DPT:1.30m RAND-WP,DPT:1.20m RAND-WP,DPT:1.40m

315mm∅/

RAND-WP,DPT:2.00m
WITH THE STANDARD SPECIFICATIONS FOR
RAND-WP,DPT:1.40m FO,DPT:0.80m RAND-WP,DPT:1.50m
RAND-WP,DPT:1.40m FO,DPT:0.80m

315mm∅/

FO,DPT:0.60m
RAND-WP,DPT:2.80m
FO,DPT:0.70m

MH81
RAND-WP,DPT:1.40m
RAND-WP,DPT:1.10m

315mm∅/ CLASS 34 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

MH312
FO,DPT:0.80m

CLASS 34
RAND-WP,DPT:1.20m RAND-WP,DPT:1.20m

MH310
315mm∅/
FO,DPT:0.60m

CLASS 34

FO,DPT:0.60m
FO,DPT:0.80m
4.

RAND-WP,DPT:1.60m

MH311
315mm∅/ CLASS 34
DPT:0.25m

315mm∅/

MH309

.60m
450Ø SW

CLASS 34 103.62 m 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,

PT:0
315mm∅/

MH314

SW,D
CLASS 34 75.00 m

MH313
110.00 m
EC,DPT:0.40m

CLASS 34 OF ANY DIRECTOR OF THE WATER AND


MH315

CLASS 34 93.66 m 100.09 m SANITATION DEPARTMENT, IN NO WAY


110.00 m 84.95 m REMOVES ANY RESPONSIBILITY WHATSOEVER
94.39 m GS,DPT:1.40m
FROM THE CONSULTANT.

WP,DPT:0.80m
9. THE CONSULTANT REMAINS RESPONSIBLE TO

RAND-WP,DPT:2.00m
ENSURE THAT ALL THE GUIDELINES, STANDARD

FO,DPT:0.80m
DRAWINGS, STANDARDS AND SPECIFICATIONS
OF WATER AND SANITATION DEPARTMENT HAVE
BEEN MET AND ARE COMPLIED WITH.

GS,DPT:1.40m

RAND-WP,DPT:1.60m
10. FINAL POSITION OF SERVICES TO BE
DETERMINED ON SITE.
11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
CONSTRUCTED AS PER COT STANDARD

PEG5
DRAWING 7515-S209

LEGEND
SEWER
NEW MANHOLE

CE / LH
EXISTING MANHOLE

NEW CCTV INSPECTION


EXIST. LINE INSPECTED BY CCTV

NEW SEWER LINE

EXISTING SEWER LINE


HOUSE CONNECTION

SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1305 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH222 - MH93 Class PE100 PN 6, SDR26

(MH315 - MH310) SLEEVE Ø TYPE CLASS


CROSSCUT

1300

1295

1290
NGL

SCALES: 1285
Horizontal 1:1000
Vertical 1:200

DATUM 1280.000

MH311
MH315

MH313

MH314

MH309

MH310
315mmØ
315mmØ 315mmØ 315mmØ
315mmØ 315mmØ 315mmØ
315mmØ 315mmØ 315mmØ
315mmØ
REFERENCE CLASS-400
CLASS-34 CLASS-400
CLASS-34 CLASS-34
CLASS-400 CLASS-34
CLASS-400 CLASS-400
CLASS-34 CLASS-400
CLASS-34 CLASS-400
CLASS-34
2103.069

2188.023

2281.682

2381.774

2491.774

2566.774
1898.683

1993.069

DISTANCE (m)
1296.021

1290.801
1297.743

1294.842

1293.607

1292.015
GROUND LEVEL
1296.600

1294.743
1294.663

1293.809
1293.729

1293.069
1293.069

1290.687
1290.607

1289.015
1288.935

1287.837
1287.757

1287.009
PIPE INVERT LEVEL
3.000
3.080

2.212
2.292

2.920
3.000

3.000
3.080

2.963
3.043
1.773
1.773

DEPTH TO INVERT

1.97% 0.78% 0.78% 2.54% 1.59% 1.00% 1.00%


1:50.8 1:128.7 1:128.7 1:39.3 1:62.9 1:100.2 1:100.2
SLOPE / LENGTH 94.39m 110.00m 84.95m 93.66m 100.09m 110.00m 75.00m

Q(l/s) 36.48 36.48 36.48 36.48 36.48 36.48 36.48


DESIGN
V(m/s) 1.4 1.5 1.4 1.4 1.6 1.3 1.3
HYDRAULICS Q(l/s) 86.41 95.96 92.53 87.21 109.62 78.55 78.54
MAX. (0.7D) 1.7 1.9 1.8 1.7 2.1 1.5 1.5
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
4 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (4 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L04 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
NOTES AND SPECIFICATIONS
GENERAL
1. ALL MATERIAL AND WORKMANSHIP MUST
COMPLY WITH THE REQUIREMENTS OF THE
LATEST RELEVANT SABS REQUIREMENTS.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
(UNLESS OTHERWISE SPECIFIED).
3. DO NOT SCALE FROM THESE DRAWINGS.
4. ALL DIMENSIONS MUST BE CHECKED AND
APPROVED ON SITE.
5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
SPECIFICATIONS FOR MUNICIPAL CIVIL
ENGINEERING WORKS, THIRD EDITION 2005 AND
THE STANDARD COT DETAIL DRAWINGS.

SW MHNNECTION
6. THESE DRAWINGS MUST BE READ IN

PROPOSED
CONJUNCTION WITH THE STANDARD
DRAWINGS.(IF APPLICABLE).

POINT 1
7. THIS DRAWING MUST BE READ IN CONJUNCTION

CL:1290.54m
IL:1286.79m
WITH THE STANDARD SPECIFICATIONS FOR

SP MH

EC,DPT:0.60m
MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

FO,DPT:0.60m
UK,DPT:1.00m WP,DPT:1.20m
BURIED

IL:1285.39m
CL:1289.49m
CO
4.

SP MH
8. THE SIGNATURE OR INITIALS ON THIS DRAWING,

FO MH
OF ANY DIRECTOR OF THE WATER AND
SANITATION DEPARTMENT, IN NO WAY

FO MH
RAND-WP,DPT:1.80m
FO,DPT:0.50m
REMOVES ANY RESPONSIBILITY WHATSOEVER

FO MH
0m 9 FO,DPT:0.70m
PT:0. RAND-WP,DPT:1.90m
RAND-WP,DPT:1.40m EC,D RAND-WP,DPT:1.00m

FO,DPT:0.80m
RAND-WP,DPT:1.40m FO,DPT:0.40m

RAND-WP,DPT:1.40m RAND-WP,DPT:1.30m FO,DPT:0.80m


RAND-WP,DPT:1.40m
FO,DPT:0.70m
RAND-WP,DPT:1.40m
RAND-WP,DPT:1.80m
FO,DPT:0.80m RAND-WP,DPT:1.40m RAND-WP,DPT:1.40m RAND-WP,DPT:1.80m RAND-WP,DPT:1.80m
FROM THE CONSULTANT.
9. THE CONSULTANT REMAINS RESPONSIBLE TO
RAND-WP,DPT:1.40m RAND-WP,DPT:1.70m
RAND-WP,DPT:1.20m

315mm∅/
FO,DPT:0.70m FO,DPT:0.85m RAND-WP,DPT:1.40m

400Ø SP
RAND-WP,DPT:1.25m

315mm∅/

UK,DPT:1.50m
FO,DPT:1.00m
WP,DPT:1.40m
RAND-WP,DPT:1.40m
ENSURE THAT ALL THE GUIDELINES, STANDARD
RAND-WP,DPT:1.20m

315mm∅/

UK,DPT:1.20m
315mm∅/ CLASS 34

FO,DPT:0.60m
RAND-WP,DPT:2.80m DRAWINGS, STANDARDS AND SPECIFICATIONS

MH81
CLASS 34

FO,DPT:0.80m
MH312
T:0.60m

DPT:0.65SWm
CLASS 34
P
MH310
SW,D

700Ø
OF WATER AND SANITATION DEPARTMENT HAVE
CLASS 34
GS,DPT:1.70m GS,DPT:1.60m
MH311

FO,DPT:0.60m
MH93
28.66 m BEEN MET AND ARE COMPLIED WITH.
WP,DPT:0.70m

75.00 m 103.62 m WP,DPT:0.80m


10. FINAL POSITION OF SERVICES TO BE
110.00 m

.80m
PT:0
EC,D
GS,DPT:1.90m GS,DPT:2.40m
FO,DPT:0.60m DETERMINED ON SITE.

FO MH
FO,DPT:0.60m
11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
CONSTRUCTED AS PER COT STANDARD

FO MH

IL:1285.77m
CL:1289.57m
DRAWING 7515-S209

SP MH
FO,DPT:0.60m
UK,DPT:1.50m
WP,DPT:1.60m
LEGEND

400Ø SP
SEWER

EC,DPT:0.90m
NEW MANHOLE

FO,DPT:0.60m
CE / LH

Z:1289.887

MH1469
PEG5
EXISTING MANHOLE

NEW CCTV INSPECTION


EXIST. LINE INSPECTED BY CCTV

FO,DPT:0.40m
MH1516

IL:1286.47m
CL:1290.07m
NEW SEWER LINE

FO MH

SP MH
EC,DPT:0.90m
EXISTING SEWER LINE
HOUSE CONNECTION

CONNECTION
400Ø SP

PROPOSED

POINT 2
FO,DPT:0.60m
SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1295 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH222 - MH93 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT
(MH312 - MH93)

1290

1285

1280
NGL

SCALES: 1275
Horizontal 1:1000
Vertical 1:200

DATUM 1270.000
MH312

MH81

MH93

315mmØ
315mmØ 315mmØ 315mmØ
315mmØ
REFERENCE CLASS-34
CLASS-400 CLASS-34
CLASS-400 CLASS-400
CLASS-34
2491.774

2566.774

2670.399

2699.055

DISTANCE (m)
1290.084

1289.612

1289.499

GROUND LEVEL
1287.757

1287.009
1286.929

1285.895
1285.895

1285.310

PIPE INVERT LEVEL


4.189
3.155

3.718
3.718

DEPTH TO INVERT

1.00% 1.00% 2.04%


1:100.2 1:100.2 1:49.0
SLOPE / LENGTH 75.00m 103.62m 28.66m

Q(l/s) 36.48 36.48 36.48


DESIGN
V(m/s) 1.3 1.5 1.6
HYDRAULICS Q(l/s) 78.54 100.78 112.18
MAX. (0.7D) 1.5 2.0 2.2
V(m/s)

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
5 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (5 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE: DATE:
DESIGN OFFICE APPROVAL
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L05 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
2 5
E ET
R
ST 4m

CLASS-400
.5

160mm∅/
T 107

78.87 m
2908 2877
ND 2718 2804 NOTES AND SPECIFICATIONS
MA 2767 2697 2859

MH22
2719 2803 2771 160mm 70/
27∅ 2769 2768 GENERAL
NIE
2772 2907 2878
CLASS-400 MH223

CLASS-400
2720 MH250 2802 SPORTS/ 1. ALL MATERIAL AND WORKMANSHIP MUST

160mm∅/
40.62 m
5
2773 COMPLY WITH THE REQUIREMENTS OF THE
13m 2801
2721 2774 m 34.54 m RECREATION LATEST RELEVANT SABS REQUIREMENTS.
10.15 2906 2879
2. ALL DIMENSIONS ARE IN MILLIMETERS.

MH

CLASS-400
160mm∅/
2722 2800 2775 16m 20m

96.20 m
CLASS-400
20m (UNLESS OTHERWISE SPECIFIED).

160mm∅/
226

83.93 m
2799 20m 3. DO NOT SCALE FROM THESE DRAWINGS.
2723
/ ∅27/ 76
mm 0 MH241 2905 2880 3826 4. ALL DIMENSIONS MUST BE CHECKED AND
mm∅-400
2798
2724
6 0 160 SS-40
2777 2808 MH300
APPROVED ON SITE.

CLASS-400
1 SS A 2807

160mm∅/
5. ALL CONSTRUCTION TO BE DONE IN
CL

58.36 m
2797 SPORTS/ 2763 2911
2725 CLA m
2778
.91
m ACCORDANCE WITH THE STANDARD
2726 1 2 .50 2796 2779 9913m RECREATION 2904 2881 SPECIFICATIONS FOR MUNICIPAL CIVIL
1 2842 ENGINEERING WORKS, THIRD EDITION 2005 AND
2795 2809 2912 THE STANDARD COT DETAIL DRAWINGS.
2727 2780 2762
3825 2882 6. THESE DRAWINGS MUST BE READ IN
2794 2781 MH227 2903
2728 CONJUNCTION WITH THE STANDARD
2793 2841 2810 DRAWINGS.(IF APPLICABLE).
MH222 2782 2761 2913

MH230
7. THIS DRAWING MUST BE READ IN CONJUNCTION
160mm∅/ 160mm∅/ 160mm∅/

MH
2792 WITH THE STANDARD SPECIFICATIONS FOR
2729 2783 MH266 MH228 2902 MH207 16mCLASS-400

232
CLASS-400

CLASS-400
CLASS-400 13m MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

160mm∅/
2791 MH210

84.20 m

CLASS-400
MH247 2883

4.8
2784 2811

160mm∅/
LH5 2914 4.

85.57 m
2840 16m 2760

0m
m 71.52 m 72.73 m 108.70 m

MH229

MH209
8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
2790 2785 62 2901
2730 10. OF ANY DIRECTOR OF THE WATER AND
2833 2834 2837 2839 2884 2885 2886 2887 2888 2889 2890 2891 SANITATION DEPARTMENT, IN NO WAY
2829 2830 2831 2832 2835 2836 2838 2915
2786 2828 2759 REMOVES ANY RESPONSIBILITY WHATSOEVER
2789 2812

CLASS-400
FROM THE CONSULTANT.

CLASS-400
LH4

160mm∅/
160mm∅/
2731

48.00 m
CLASS-400

47.93 m
160mm∅/
9. THE CONSULTANT REMAINS RESPONSIBLE TO

43.96 m
2900 2899 2895 2894 2893 2892 ENSURE THAT ALL THE GUIDELINES, STANDARD
2826 2825 2824 2822 2821 2820 2819 2818 2816 2815 2814 2813 2758 2916 2898 2897 2896 DRAWINGS, STANDARDS AND SPECIFICATIONS
2823 2817

CLASS-400
2788 2787 2827

160mm∅/
OF WATER AND SANITATION DEPARTMENT HAVE

25.27 m
2732
BEEN MET AND ARE COMPLIED WITH.

MH301
2917

MH237
10. FINAL POSITION OF SERVICES TO BE
160mm∅/ 160mm∅/ 160mm∅/ 160mm∅/ 2757 160mm∅/ 160mm∅/
MH251 13m MH231 MH242 DETERMINED ON SITE.
MH246 CLASS-400 MH238 CLASS-400 CLASS-400 CLASS-400 CLASS-400 16m CLASS-400 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
2733 MH216 CONSTRUCTED AS PER COT STANDARD
11.99 m 63.01 m 83.18 m

MH243
90.70 m 89.40 m 49.12 m

MH215
34.00 m DRAWING 7515-S209

LH24
2918
2740 2741 2743 2744 2745 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2919 2920 2921 2922 2923 2924 2925 2926 2928 2929
2734 2735 2736 2737 2738 2739 2742 2746 2927

CLASS-400
LEGEND

CLASS-400

160mm∅/
160mm∅/

36.00 m
36.00 m
SEWER
NEW MANHOLE

MH253
MH252
KINGFISHK ER
I N G F STREET
I S H E R S T R E20m
E T 20m
MH244
160mm∅/
CLASS-400
160mm∅/
CLASS-400
160mm∅/
CLASS-400 MH234 KINGFISHER
160mm STREET 20m
CE / LH
CLASS-400
EXISTING MANHOLE
62.17 m 76.52 m 90.75 m 91.14 m
NEW CCTV INSPECTION
2997 2996160mm 95
29∅ 3055 3054 3052 3051 3050 3049 3048 3047 3046 3045 3044 3043 3042 3140 3141
2999 2998 / 2994 2993 2992 3053

16 AS
MH204 MH203 EXIST. LINE INSPECTED BY CCTV

CL .80
CLASS-400

0m S-4
MH202∅

m 00
3056 NEW SEWER LINE

/
82.63 m

4
2991 160mm∅/ 160mm∅/ 160mm EXISTING SEWER LINE

m
16m 3057MH153 CLASS-400 MH254 16m CLASS-400 MH255 CLASS-400
HOUSE CONNECTION
69.76 m 96.60 m 84.51 m
SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1340 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH227 - MH237 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1335

1330

1325
NGL

SCALES: 1320
Horizontal 1:1000
Vertical 1:200

DATUM 1315.000

MH231
MH227

MH226

MH225

MH223

MH228
MH229

MH230

MH237
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400
207.821
110.061

202.966

216.145

264.076

313.195
144.606
99.909
0.000

DISTANCE (m)
1327.641
1332.364

1331.444

1331.190

1329.797

1327.684

1327.960

1325.633

1323.954
GROUND LEVEL
1329.611
1330.860

1329.530
1329.429
1329.349

1328.230
1328.155

1325.313
1325.233
1325.172
1325.175
1325.092
1325.095

1323.497
1323.337

1321.670

PIPE INVERT LEVEL


2.371
2.451
1.761
1.841

2.469
2.466
2.868
2.865

2.136
2.296

2.284
1.642
1.504

1.833
1.914

1.566

DEPTH TO INVERT

1.25% 1.00% 3.24% 4.87% 1.25%


1.00% 3.33% 3.39%
1:80.0 1:100.0 1:30.9 1:20.5 1:80.0
1:100.0 1:30.0 1:29.5
SLOPE / LENGTH 99.91m 10.15m 34.54m 58.36m 4.86m8.32m 47.93m 49.12m

Q(l/s) 0.21 0.23 0.30 0.49 0.52 0.52 0.96 2.03


DESIGN
V(m/s) 0.3 0.3 0.5 0.7 0.4 0.4 0.7 0.9
HYDRAULICS Q(l/s) 14.41 12.89 23.19 28.44 14.4112.89 23.53 23.74
MAX. (0.7D) 1.1 1.0 1.7 2.1 1.1 1.0 1.8 1.8
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
6 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (6 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L06 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
2 5 2 5
T T
EE EE
ST
R 4 m S TR .54
m
T 107.5 T 1 07
D D 2804
AN
2804 NOTES AND SPECIFICATIONS
N 2718 2718
MA 2697
M 2767

MH22
2767 2719 2803 2771 160mm 70/
27∅

MH22
2719 2803 2771 160mm 70/ 2769 2768
27∅ 2769 2768
E GENERAL
NIE I
2772 2772
CLASS-400 MH223 N 2720 2802 CLASS-400 MH223

CLASS-400
2720 2802 MH250 1.
ALL MATERIAL AND WORKMANSHIP MUST

160mm∅/
MH250

5
2773

40.62 m
5
2773 13m COMPLY WITH THE REQUIREMENTS OF THE
13m 2801 2721 2801 34.54 m
2721 34.54 m 2774 m
m 10.15
2774 LATEST RELEVANT SABS REQUIREMENTS.
10.15

MH
MH
2722 2800 2. ALL DIMENSIONS ARE IN MILLIMETERS.
2722 2800 2775 16m 2775 16m

226
20m (UNLESS OTHERWISE SPECIFIED).

226
2799 2723 2799 3. DO NOT SCALE FROM THESE DRAWINGS.
2723 2776
mm∅ 0
/2776
MH241 m∅/ 00 4. ALL DIMENSIONS MUST BE CHECKED AND
/ m∅/ 2798 m
mm∅-400 160 SS-4
2798
2724 0 160 SS-40
2777 2808 2724
60m -400 2777 2808 APPROVED ON SITE.

CLASS-400
6 1 SS 2807

CLASS-400
2807
CLA

160mm∅/
1 SS
CLA

160mm∅/
5. ALL CONSTRUCTION TO BE DONE IN

58.36 m
2797 SPORTS/
CLA

58.36 m
2797 SPORTS/ 2763 2725 2778
2725 CLA m
2778
.91
m m .91
m ACCORDANCE WITH THE STANDARD
.50 9913m .50 9913m
112
2 2726 2796 2779 RECREATION SPECIFICATIONS FOR MUNICIPAL CIVIL
2726 1 1 2796 2779 RECREATION
2842 2842 2809 ENGINEERING WORKS, THIRD EDITION 2005 AND
2795 2809 2795 2780
2727 2780 2762 2727 3825
THE STANDARD COT DETAIL DRAWINGS.
3825 6. THESE DRAWINGS MUST BE READ IN
2794 2794 2781 MH227
2728 2781 MH227 2728 CONJUNCTION WITH THE STANDARD
2793 2810 2793 2841 2810 DRAWINGS.(IF APPLICABLE).
MH222 2782 2841 MH222 2782

MH230
2761

MH230
7. THIS DRAWING MUST BE READ IN CONJUNCTION
160mm∅/ 160mm∅/

MH
160mm∅/ 160mm∅/ 2792

MH
2792 2783 MH228 WITH THE STANDARD SPECIFICATIONS FOR
2783 MH228 MH266

232
2729 MH266 2729 CLASS-400 CLASS-400

232
CLASS-400 CLASS-400

CLASS-400
13m 13m MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

160mm∅/
2791 MH247 2791

84.20 m
MH247 2784 LH5 2811 2784 LH5 2811
2840 16m 2760 2840 16m 4.
2m 71.52 m 72.73 m

MH229
m 71.52 m 72.73 m

MH229
2790 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
2790 62 2785 6
2730 2785
10. 2730 10. OF ANY DIRECTOR OF THE WATER AND
2832 2833 2834 2835 2836 2837 2839 2829 2830 2831 2832 2833 2834 2835 2836 2837 2838 2839 SANITATION DEPARTMENT, IN NO WAY
2829 2830 2831 2838 2786 2828
2786 2828 2759 2812 REMOVES ANY RESPONSIBILITY WHATSOEVER
2812 2789

CLASS-400
2789 LH4

CLASS-400
LH4 FROM THE CONSULTANT.

160mm∅/
2731

160mm∅/

CLASS-400

47.93 m
2731
CLASS-400

47.93 m

160mm∅/
160mm∅/

9. THE CONSULTANT REMAINS RESPONSIBLE TO

43.96 m
43.96 m

ENSURE THAT ALL THE GUIDELINES, STANDARD


2826 2825 2824 2822 2821 2819 2818 2816 2815 2813 2758 2826 2825 2824 2823 2822 2821 2820 2819 2818 2817 2816 2815 2814 2813
2823 2820 2817 2814 DRAWINGS, STANDARDS AND SPECIFICATIONS

CLASS-400
2788 2787 2827
CLASS-400

2788 2827

160mm∅/
2787
160mm∅/

25.27 m
2732 OF WATER AND SANITATION DEPARTMENT HAVE
25.27 m

2732
BEEN MET AND ARE COMPLIED WITH.

MH237
MH237
160mm∅/ 160mm∅/ 160mm∅/ 160mm∅/ 2757 160mm∅/ 160mm∅/ 160mm∅/ 160mm∅/ 10. FINAL POSITION OF SERVICES TO BE
MH251 13m MH231 MH242 MH246 CLASS-400 MH238 MH251 13m MH231 DETERMINED ON SITE.
MH246 CLASS-400 MH238 CLASS-400 CLASS-400 CLASS-400 2733
CLASS-400 CLASS-400 CLASS-400 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
2733
CONSTRUCTED AS PER COT STANDARD
34.00 m 90.70 m 89.40 m 49.12 m

MH243
34.00 m 90.70 m 89.40 m 49.12 m DRAWING 7515-S209

2738 2740 2741 2743 2744 2745 2747 2748 2749 2750 2751 2752 2753 2754 2755 2756 2734 2735 2736 2737 2738 2739 2740 2741 2742 2743 2744 2745 2746 2747 2748 2749 2750 2751 2752 2753 2754 2755
2734 2735 2736 2737 2739 2742 2746

CLASS-400
LEGEND

CLASS-400
160mm∅/

36.00 m
36.00 m
SEWER
NEW MANHOLE
KINGFISHK ER
I N G F STREET
I S H E R S T R E20m
E T 20m
MH244
160mm∅/ KINGFISHER STREET 20m K I N G F I S H E R S T R E E T 20m
MH244 CE / LH
CLASS-400
EXISTING MANHOLE
62.17 m
NEW CCTV INSPECTION
2997 95
29∅
2996160mm / 2999 2998 2997 2996160mm 95
29∅/ 2994 2993
2999 2998 2994 2993 2992

16 AS
MH204 MH203 MH204 CLASS-400 MH203 EXIST. LINE INSPECTED BY CCTV

CL .80
CLASS-400

0m S-4
MH202

m∅ 00
NEW SEWER LINE

/
82.63 m

4.8
82.63 m

0m
2991 EXISTING SEWER LINE

m
16m 16m
HOUSE CONNECTION

SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1340 1340 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH247 - MH231 LONGSECTION LH4 - MH238 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1335 1335

1330 1330

1325 1325
NGL NGL

SCALES: 1320 SCALES: 1320


Horizontal 1:1000 Horizontal 1:1000
Vertical 1:200 Vertical 1:200

DATUM 1315.000 DATUM 1315.000


MH251

MH231
MH247

MH246

MH238

MH238
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ

LH4
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 REFERENCE CLASS-400
168.661

258.059
43.961

77.961

25.272
0.000

0.000
DISTANCE (m) DISTANCE (m)
1334.337

1332.030

1331.202

1328.540

1325.633

1332.552

1331.202
GROUND LEVEL GROUND LEVEL
1332.382

1330.075
1329.995

1329.247
1329.167

1326.184
1326.104

1323.417

1330.897

1329.247
PIPE INVERT LEVEL PIPE INVERT LEVEL
2.035

2.035

2.355
2.435

2.216
1.955

1.955

1.955

1.655

1.955
DEPTH TO INVERT DEPTH TO INVERT

5.25% 2.20% 3.29% 3.01% 6.53%


1:19.1 1:45.5 1:30.4 1:33.3 1:15.3
SLOPE / LENGTH 43.96m 34.00m 90.70m 89.40m SLOPE / LENGTH 25.27m

Q(l/s) 0.21 0.28 0.65 0.96 Q(l/s) 0.07


DESIGN DESIGN
V(m/s) 0.5 0.4 0.6 0.7 V(m/s) 0.4
HYDRAULICS Q(l/s) 29.52 19.11 23.37 22.34 HYDRAULICS Q(l/s) 32.93
MAX. (0.7D) 2.2 1.4 1.8 1.7 MAX. (0.7D) 2.5
V(m/s) V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
7 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (7 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L07 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
2 5
E T

CLASS-400
R E

160mm
ST 4m

2900

3053
.5

2905
2909

2906
2907
T

2902
2903
107

2910

2908

2904

2901
D

2920
2804 160mm∅/
AN 2718 160mm∅/ NOTES AND SPECIFICATIONS

2852

MH218
CLASS-400 CLASS-400
M 2767

MH22
2719 2803 2771 160mm 70/

3054
27∅ 2769 2768 MH215
I E 2772 GENERAL

11.99 m
N CLASS-400 MH223

2919
2720 2802 78.87 m

MH300
16m
MH250 85.57 m 1.
ALL MATERIAL AND WORKMANSHIP MUST

5
2773 COMPLY WITH THE REQUIREMENTS OF THE
13m 2801

2854MH213
2721 2774 m 34.54 m
10.15
LATEST RELEVANT SABS REQUIREMENTS.

3055
2853
MH
2722 2800 2775 16m LH24 2. ALL DIMENSIONS ARE IN MILLIMETERS.

2859
226
(UNLESS OTHERWISE SPECIFIED).

2858

2911
2855

2856

2857

2912

2918
2916
2914
2913

2915

3056
2917
2799

20m
2723 2776 MH252 3. DO NOT SCALE FROM THESE DRAWINGS.
m∅/ 00 4. ALL DIMENSIONS MUST BE CHECKED AND
2724 m∅/ 2798 m
160 SS-4
60m -400 2777 2808 APPROVED ON SITE.

CLASS-400
1 SS 2807
CLA

160mm∅/
5. ALL CONSTRUCTION TO BE DONE IN

58.36 m
2797 SPORTS/
2725 CLA m
2778
.91
m ACCORDANCE WITH THE STANDARD
.50 9913m
2726 112
2795
2796 2779 RECREATION
2842 2809
EAGLE STREET 25m SPECIFICATIONS FOR MUNICIPAL CIVIL
ENGINEERING WORKS, THIRD EDITION 2005 AND
2780

CLASS-400
2727 3825
THE STANDARD COT DETAIL DRAWINGS.

62.17 m
160mm∅/
2794 6. THESE DRAWINGS MUST BE READ IN
2728 2781 MH227 CONJUNCTION WITH THE STANDARD
2793 2841 2810 DRAWINGS.(IF APPLICABLE).
MH222 2782

MH230

27001
2702
7. THIS DRAWING MUST BE READ IN CONJUNCTION

2699

MH240 2698
2700
160mm∅/

MH242
160mm∅/

MH

2763

2761

2759

2758
2760
20m
2697
2792

2762

2757
2783 MH228 WITH THE STANDARD SPECIFICATIONS FOR

MH22
MH266 160mm∅/ 160mm∅/ 160mm∅/

232
2729 160mm∅/

2703
CLASS-400 CLASS-400
13m MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
MH247 2791 ∅0

MH202 /
2784 2811 CLASS-400 CLASS-400 0

MH241
LH5

2756
CLASS-400 CLASS-400

MH2030mm
2840 -4 4.

LH2
71.52 m 72.73 m 16m S
m

MH229

29192
2790 62 MH243 S 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,

6
2785
2730 10. 14.94 m 46.82 m 160mm∅/ A m

16m
40.62 m CL .80 OF ANY DIRECTOR OF THE WATER AND

16m
84.20 m

19.70 m
2833 2837 2839

MH244
2829 2830 2831 2832 2834 2835 2836 2838 CLASS-400 4 SANITATION DEPARTMENT, IN NO WAY
2786 2828 MH237 REMOVES ANY RESPONSIBILITY WHATSOEVER
2812

2704
2789

CLASS-400
LH4 36.00 m FROM THE CONSULTANT.

2993
160mm∅/

MH219
2731

2755
CLASS-400

47.93 m
160mm∅/
9. THE CONSULTANT REMAINS RESPONSIBLE TO
43.96 m

2765
2764

2808
2766

2811
2767

2810
2809

2812
ENSURE THAT ALL THE GUIDELINES, STANDARD
2826 2825 2824 2822 2821 2819 2818 2816 2815 2813

2705
2823 2820 2817 2814 DRAWINGS, STANDARDS AND SPECIFICATIONS

CLASS-400
2788 2787 2827

160mm∅/

2994
2754
25.27 m

CLASS-400
2732 OF WATER AND SANITATION DEPARTMENT HAVE

49.12 m
160mm∅/
BEEN MET AND ARE COMPLIED WITH.

2813
MH237

2768
160mm∅/

2807
160mm∅/

2706
160mm∅/ 10. FINAL POSITION OF SERVICES TO BE

2841
160mm∅/

2840
2842
160m S-400

MH228
3m

CLASS-400
MH246 CLASS-400 MH238 MH251 13m MH231 160mm∅/
DETERMINED ON SITE.

95
2753
CLASS-400 CLASS-400 CLASS-400

82.63 m
29∅/
m∅/
2733 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE

51.9

2996160mm
CLASS-400 MH223
CLASS-400

S
CONSTRUCTED AS PER COT STANDARD

CRECHE
89.40 m 49.12 m

CLA
34.00 m 90.70 m

2707

2769

2839
DRAWING 7515-S209

2814
58.36 m MH229
160mm∅/

16m

2752
2734 2738 2739 2740 2741 2742 2743 2744 2745 2747 2748 2749 2750 2751 2752 2753 2754 2755

2806
2735 2736 2737 2746

CLASS-400

MH231
CLASS-400 LEGEND

36.00 m

34.54 m
2708
MH230

70/
27∅
SEWER

2771 160mm
47.93 m

MH221

2997
2815

2751
2838
RECREATION
NEW MANHOLE
KINGFISHER STREET 20m

SPORTS/
2709
K I N G F I S H E R S T R E E T 20m
MH244 CE / LH

2750

2998
2816
2837
EXISTING MANHOLE

m
5
MH22

MH204
2710

10.15
NEW CCTV INSPECTION

2772

CLASS-400
3825
2997 95
29∅
2996160mm

2817
2999 2998 / 2994

2836

2749
2993
226

2999
72.73 m
160mm∅/
MH204 MH203

2711
CLASS-400 EXIST. LINE INSPECTED BY CCTV
MH

2805

CLASS-400
2773
NEW SEWER LINE

89.40 m
160mm∅/
82.63 m

2818
4.8

2835

2748
13m
0m

2712

2804
EXISTING SEWER LINE
16m

2774
mm -400

.54

2834
HOUSE CONNECTION

2819
∅/

2747
7
1 SS
2713

1 0
SUBURB BOUNDARY

CLA
60
04100823 PIPE NUMBER
DIRECTION OF FLOW
1340 1340 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION LH5 - MH230 LONGSECTION LH2 - MH220 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1335 1335

1330 1330

1325 1325
NGL NGL

SCALES: 1320 SCALES: 1320


Horizontal 1:1000 Horizontal 1:1000
Vertical 1:200 Vertical 1:200

DATUM 1315.000 DATUM 1315.000


MH232

MH266

MH230

MH220
160mmØ 160mmØ
LH5

160mmØ

LH2
REFERENCE CLASS-400 CLASS-400 REFERENCE CLASS-400
154.869
82.137
10.617

14.944
0.000

0.000
DISTANCE (m) DISTANCE (m)
1332.408

1332.402

1330.292

1327.960

1331.914

1331.217
GROUND LEVEL GROUND LEVEL
1330.560
1330.427
1330.347

1328.037
1327.957

1325.175

1327.853

1327.666
PIPE INVERT LEVEL PIPE INVERT LEVEL
2.055

2.255
2.335

2.785
1.849
1.975

4.061

3.551
DEPTH TO INVERT DEPTH TO INVERT

1.25% 3.23% 3.82% 1.25%


1:80.0 1:31.0 1:26.1 1:80.0
SLOPE / LENGTH 10.62m 71.52m 72.73m SLOPE / LENGTH 14.94m

Q(l/s) 0.05 0.19 0.33 Q(l/s)


DESIGN DESIGN 0.07
V(m/s) 0.2 0.4 0.6 V(m/s) 0.2
HYDRAULICS Q(l/s) 14.41 23.16 25.20 HYDRAULICS Q(l/s) 14.41
MAX. (0.7D) 1.1 1.7 1.9 MAX. (0.7D)
V(m/s) V(m/s) 1.1
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
8 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (8 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L08 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
NIEMANDT STREET 2

SECONDARY SC

20m

3146

16m

3192

3209
NOTES AND SPECIFICATIONS

ER STREET
GENERAL

3145

3191

3210

CLASS-400
2930
1.
ALL MATERIAL AND WORKMANSHIP MUST

160mm∅/
MH258

MH256
COMPLY WITH THE REQUIREMENTS OF THE
LATEST RELEVANT SABS REQUIREMENTS.

3144

3190

3211
2. ALL DIMENSIONS ARE IN MILLIMETERS.
(UNLESS OTHERWISE SPECIFIED).
3. DO NOT SCALE FROM THESE DRAWINGS.

3143
4. ALL DIMENSIONS MUST BE CHECKED AND

3189

3212
APPROVED ON SITE.
NIEMANDT STREET 25m 5. ALL CONSTRUCTION TO BE DONE IN

KINGFISH
ACCORDANCE WITH THE STANDARD

3213
3142
SPECIFICATIONS FOR MUNICIPAL CIVIL

3188
ENGINEERING WORKS, THIRD EDITION 2005 AND

CLASS-400
THE STANDARD COT DETAIL DRAWINGS.

CLASS-400

84.51 m
160mm∅/
2703 2852 2851 2850 2849 2848 2847 2846 2845 2844 2843 MH2616. CONJUNCTION
THESE DRAWINGS MUST BE READ IN

3141
91.14 m
160mm∅/
2853

3214
EAGLE STREET 25m

3187
2704 WITH THE STANDARD
2705 LH2 DRAWINGS.(IF APPLICABLE).
7. THIS DRAWING MUST BE READ IN CONJUNCTION

MH299
CLASS-400
160mm∅/

160mm∅/ WITH THE STANDARD SPECIFICATIONS FOR


160mm∅/

3140
14.94 m

3215
3186
2702 16m MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
2854MH213 CLASS-400 CLASS-400 4.
MH219 MH214 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
74.91 m 84.95 m OF ANY DIRECTOR OF THE WATER AND
19.70 m 27001
MH22

16m
2861 SANITATION DEPARTMENT, IN NO WAY
2855 MH218 2860 2862 2863 2864 2865 2866 2867

CLASS-400
CLASS-400
2868 REMOVES ANY RESPONSIBILITY WHATSOEVER

160mm∅/
34.00 m

160mm∅/
FROM THE CONSULTANT.

MH212
MH214

MH210
2764

MH216
9. THE CONSULTANT REMAINS RESPONSIBLE TO

MH255
2700 160mm∅/ 160mm∅/ 160mm∅/ 160mm∅/
CLASS-400

2856 2910
160mm∅/

ENSURE THAT ALL THE GUIDELINES, STANDARD

3095
3094
3042
46.82 m

28 71 ∅/2870 2869 CLASS-400 CLASS-400 CLASS-400

MH234
2875 2874 2873 2872 160mm CLASS-400 DRAWINGS, STANDARDS AND SPECIFICATIONS
16m OF WATER AND SANITATION DEPARTMENT HAVE
2765 CLASS-400 34.00 m 96.20 m 48.00 m
2699 2857 MH212 36.00 m BEEN MET AND ARE COMPLIED WITH.

20m
16m

3096
3093
10. FINAL POSITION OF SERVICES TO BE

3043
2909 2876 97.45 m

MH211
DETERMINED ON SITE.
2766 MH208 16m 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
MH240 2698 2858 SECONDARY SCHOOL CONSTRUCTED AS PER COT STANDARD
CLASS-400

3097
3092
3044
160mm∅/
78.87 m

2908 2877 DRAWING 7515-S209

2891

2892

2929
2868

2869
2843
2767 2697 2859 MH262LEGEND

3098
3091
3045
2907 2878

CLASS-400
SEWER

CLASS-400

CLASS-400
2893
CLASS-400

SPORTS/

2890

83.18 m
84.95 m
160mm∅/

160mm∅/
160mm∅/

2867

71 ∅/2870

2928

96.60 m
CLASS-400

160mm∅/
40.62 m

2844
NEW MANHOLE

CLASS-400

90.75 m
160mm∅/
RECREATION
97.45 m

3090

3099
RECREATION

3046
2879

160mm
2906

16mCLASS-400
CE / LH

SPORTS/
CLASS-400

13m
2894
160mm∅/

108.70 m

2927
2889
2866

160mm∅/
20m

96.20 m
CLASS-400

20m
160mm∅/

2845
83.93 m

28
20m EXISTING MANHOLE

3826

3089

3100
3047
MH241 3826 2930

16m
2905 2880 NEW CCTV INSPECTION

2888

2895

2926
2808

2865

2872
MH300

CLASS-400
2846
2763 2911 EXIST. LINE INSPECTED BY CCTV

160mm∅/
3101
3088
3048
2904 2881 NEW SEWER LINE

2896
2887

2925
2873
2864
2809 2912

2847

MH254 16m
2762 EXISTING SEWER LINE
MH301

3087

3102
3049
2882 MH299
2903

2897
HOUSE CONNECTION

16m

2924
2886
2863

2874
2810

2848
2913 MH253 SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1335 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH213 - MH234 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1330

1325

1320
NGL

SCALES: 1315
Horizontal 1:1000
Vertical 1:200

DATUM 1310.000
MH213

MH299

MH214

MH212

MH210

MH216

MH234
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400

374.061
290.059

338.060
159.857

193.857
74.910
0.000

DISTANCE (m)
1329.660

1327.314

1325.643

1323.423

1318.809

1317.200

1315.953
GROUND LEVEL
1327.405

1324.639
1324.559

1322.955
1322.875

1321.768
1321.688

1316.600
1316.520

1315.157
1315.077

1313.796
PIPE INVERT LEVEL
2.688
2.768

2.209
2.289

2.044
2.124

2.157
2.255

2.675
2.755

1.655
1.735

DEPTH TO INVERT

3.69% 1.89% 3.26% 5.29% 2.84% 3.56%


1:27.1 1:53.0 1:30.7 1:18.9 1:35.2 1:28.1
SLOPE / LENGTH 74.91m 84.95m 34.00m 96.20m 48.00m 36.00m

Q(l/s) 0.26 0.49 0.49 0.65 1.26 2.26


DESIGN
V(m/s) 0.5 0.5 0.6 0.8 0.8 1.0
HYDRAULICS Q(l/s) 24.76 17.71 23.26 29.64 21.72 24.31
MAX. (0.7D) 1.9 1.3 1.7 2.2 1.6 1.8
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
9 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (09 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L09 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
CLASS-400
84.95 m
2867
2844

160mm

m∅/ 2870
20m 2906 2879

CLASS-400
20m RECREATION NOTES AND SPECIFICATIONS

2893

CLASS-400
2890

3045
97.45 m

RECREATION

3091

CLASS-400
160mm∅/
MH241

83.18 m

160mm∅/
2928

83.93 m
GENERAL

2866

160m

CLASS-400
2845

CLASS-400
SPORTS/
2871

CLASS-400
160mm∅/

160mm∅/
96.20 m
96.60 m
160mm∅/

90.75 m
16mCLASS-400
2905 2880 1. ALL MATERIAL AND WORKMANSHIP MUST
20m

108.70 m
160mm∅/
2763

2889

2894
MH300

3046
3826 COMPLY WITH THE REQUIREMENTS OF THE

3826
2911

3090
16m

2927
LATEST RELEVANT SABS REQUIREMENTS.

2865
2846

2872
2. ALL DIMENSIONS ARE IN MILLIMETERS.
2904 2881 2930 (UNLESS OTHERWISE SPECIFIED).

2888

2895
2762 2912

3047

3089
3. DO NOT SCALE FROM THESE DRAWINGS.

2926
2864

2873
2847
4. ALL DIMENSIONS MUST BE CHECKED AND
2903 2882 APPROVED ON SITE.
MH299

2887
2761 5. ALL CONSTRUCTION TO BE DONE IN

3048
2896
2913

16m

3088
2925
ACCORDANCE WITH THE STANDARD

2863
2848

CLASS-400
2874
SPECIFICATIONS FOR MUNICIPAL CIVIL

160mm∅/
84.20 m
MH301 2902

MH254 16m
16m MH207 160mm∅/ ENGINEERING WORKS, THIRD EDITION 2005 AND

2897
2760

2886

3049
2914

CLASS-400
THE STANDARD COT DETAIL DRAWINGS.

3087
2924

160mm∅/
2883

85.57 m
16mCLASS-400

4 .8
MH211

2862
6. THESE DRAWINGS MUST BE READ IN

2849

0m
2875
MH253

MH209
MH208

16m
2901 MH210
CONJUNCTION WITH THE STANDARD
108.70 m

2885
2759 DRAWINGS.(IF APPLICABLE).

3050
2898
160mm∅/ 2915

3086
2884 2885 7. THIS DRAWING MUST BE READ IN CONJUNCTION

3103
2923
2886 2887

2861
CLASS-400 2888
2850

2889 2890

CLASS-400
WITH THE STANDARD SPECIFICATIONS FOR
MH209 2891
160mm∅/

74.91 m
MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

CLASS-400
0m

2876
2758

2877
83.93 m

3051
2878

160mm∅/
4.

2879

2884

2899

63.01 m
4.8 2916 2900

2880

3085
MH207

2922

CLASS-400
2881

2882
2899 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,

2883

160mm∅/
48.00 m
2860
2851

2898 2897 OF ANY DIRECTOR OF THE WATER AND


2896 2895 2894 2893

MH237
2892 SANITATION DEPARTMENT, IN NO WAY
2757

3052
2917

CLASS-400
MH242

2910

2909
REMOVES ANY RESPONSIBILITY WHATSOEVER

CLASS-400
2921

160mm∅/
2907
2908

69.76 m
2906

3084
2905

160mm∅/
2852

76.52 m
160mm∅/ FROM THE CONSULTANT.

MH301
2904

2900
2903
160mm∅/

2902
9. THE CONSULTANT REMAINS RESPONSIBLE TO
MH218
CLASS-400

2901
160mm∅/

MH243
CLASS-400 16m

3053
ENSURE THAT ALL THE GUIDELINES, STANDARD
160mm∅/ 11.99 m CLASS-400

2920

MH215
2756 2918 DRAWINGS, STANDARDS AND SPECIFICATIONS

LH24
CLASS-400 63.01 m

16m

CLASS-400
3139
78.87 m MH216 OF WATER AND SANITATION DEPARTMENT HAVE

160mm∅/
2919 2920 2921 83.18 m

MH300
2854MH213

MH215 2922 BEEN MET AND ARE COMPLIED WITH.


2853

85.57 m 2923

3054
2924 2925

11.99 m
2926 10. FINAL POSITION OF SERVICES TO BE

2919
2927 2928
2929 DETERMINED ON SITE.
2855

MH191

CLASS-400
11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
2856

2857

160mm∅/
2858

2859

36.00 m
160mm∅/

MH252
CONSTRUCTED AS PER COT STANDARD

2911
MH244

2912

3055
LH24

20m

3057MH153

MH253
DRAWING 7515-S209

2913
CLASS-400 160mm∅/

2914

2915

2916

2917

2918
CLASS-400 160mm∅/
MH252 LEGEND

3056
62.17 m
CLASS-400
EAGLE STREET

3058
KCLIN

3059
25m 2992 76.52 m MH234 G 0 ISHER STR
160mm∅/
ASS-40F EET 20m SEWER

16 ASS
MH203 3055 90.75 m

CL
MH258

0m -4
3054 3053 3052 3051 NEW MANHOLE
MH202 3050

m∅ 00
3049 3048
3047 91.14 m CLASS-400

/
3056 3046 3045

4.8
3044 3043 3042 CE / LH

0m
2991 3140 3141 3142 3143

CLASS-400
3144
2702

160mm∅/ 3145 EXISTING MANHOLE


2701

3146 3148

160mm∅/
3057MH153 3147
2700

62.17 m
2699
MH220

MH240 2698
2703

160mm∅/ CLASS-400
2697

160mm∅/ MH254 16m 160mm∅/ NEW CCTV INSPECTION


20m

2763
CLASS-400

2762

2761
160mm∅/ CLASS-400

2760

2759
LH2

CLASS-400 2990 160mm∅/

2758

MH242
69.76 m MH255 EXIST. LINE INSPECTED BY CCTV

2757
CLASS-400 160mm∅/
MH241

14.94 m 3058 CLASS-400

2991
46.82 m CLASS-400 96.60 m MH256 160mm∅

2990
16m

2989
19.70 m

NEW SEWER LINE


16m

3084

2988
40.62 m / 3085 3086 3087 CLASS-400

2756
3088
m∅ 400 160mm 2989 3089 3090 3091 3092
84.51 m

16m
EXISTING SEWER LINE
2704

84.20 m MH243

MH202
m
0 - 3059 3139 3093
16 ASS 3094 86.11 m

2992
CLASS-400

MH203
160mm∅/
MH219

CLASS-400
MH191 3186 3187 3188 3189

160mm
CL
HOUSE CONNECTION
0m 3190

86.01 m
CLASS-400 16m 3191 3192
2764

MH244
2765

MH237 4.8 86.01 m 2988 3193 3194


2766
2705

2767

3103 SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1330 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH218 - MH216 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1325

1320

1315
NGL

SCALES: 1310
Horizontal 1:1000
Vertical 1:200

DATUM 1305.000
MH301
MH218

MH300

MH215

MH216
160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400
227.459

310.642
164.446
78.873
0.000

DISTANCE (m)
1328.429

1325.037

1321.507

1319.667

1317.200
GROUND LEVEL
1319.551
1319.471
1326.474

1323.082
1323.002

1317.896
1317.816

1315.043

PIPE INVERT LEVEL


1.771
1.851
2.035

2.035

2.157
1.955

1.955

1.955

DEPTH TO INVERT

4.30% 4.03% 2.50% 3.33%


1:23.3 1:24.8 1:40.0 1:30.0
SLOPE / LENGTH 78.87m 85.57m 63.01m 83.18m

Q(l/s) 0.26 0.49 0.77 1.00


DESIGN
V(m/s) 0.5 0.6 0.6 0.7
HYDRAULICS Q(l/s) 26.72 25.88 20.38 23.53
MAX. (0.7D) V(m/s) 2.0 1.9 1.5 1.8

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
10 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (10 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L10 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
LE STREET 25m
MH218 2860 2861 84.95 m MH214
2862 2863
CLASS-400
2700
2864 2865 2866 2867
NOTES AND SPECIFICATIONS
160mm∅/
46.82 m

2856 2868

CLASS-400
GENERAL

160mm∅/
34.00 m
2910
16m 1. ALL MATERIAL AND WORKMANSHIP MUST
2699 2875 2874 COMPLY WITH THE REQUIREMENTS OF THE
2857
2873 2872 2871
m∅/2870
160m 2869 NIEMANDT STR LATEST RELEVANT SABS REQUIREMENTS.
16m
2909 CLASS-400 EET 25m 2. ALL DIMENSIONS ARE IN MILLIMETERS.

EAGLE STREET
2876 2853 2852 2851 (UNLESS OTHERWISE SPECIFIED).
2850

MH211
MH240 2698 97.45 m MH212 2849 2848 2847 3. DO NOT SCALE FROM THESE DRAWINGS.
2858 MH208 2846 2845 2844 2843 4. ALL DIMENSIONS MUST BE CHECKED AND

CLASS-400
16m

160mm∅/
78.87 m
APPROVED ON SITE.
2908 2877 2702
2697 160mm∅/ 5. ALL CONSTRUCTION TO BE DONE IN

MH299
2859 2854MH213 ACCORDANCE WITH THE STANDARD
CLASS-400 16m 160mm∅/
CLASS-400

SPECIFICATIONS FOR MUNICIPAL CIVIL


160mm∅/

SECONDARY SCHOOL
40.62 m

2907 2878 2701 CLASS-400 ENGINEERING WORKS, THIRD EDITION 2005 AND
74.91 m THE STANDARD COT DETAIL DRAWINGS.
2855
SPORTS/ MH218 2860 2861 84.95 m MH214 6. THESE DRAWINGS MUST BE READ IN
2862 2863 CONJUNCTION WITH THE STANDARD
20m 2906 2879 2864 2865
20m RECREATION 2700 2866 2867 DRAWINGS.(IF APPLICABLE).
2856 2868

CLASS-400
CLASS-400
MH241 7. THIS DRAWING MUST BE READ IN CONJUNCTION

160mm∅/
160mm∅/

34.00 m
2910

83.93 m
WITH THE STANDARD SPECIFICATIONS FOR

CLASS-400
160mm∅/
96.20 m
2905 2880 2875 2874 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
2763 20m 2699 2873 2871
MH300 3826 2872 m∅/2870 4.

25m
2911 2857 160m 2869
16m 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
2909 CLASS-400 OF ANY DIRECTOR OF THE WATER AND
2881 2876
2904 2930

MH211
SANITATION DEPARTMENT, IN NO WAY
2762 2912 97.45 m MH212 REMOVES ANY RESPONSIBILITY WHATSOEVER
2858 MH208

CLASS-400
16m FROM THE CONSULTANT.

160mm∅/
78.87 m
2903 2882 2908 2877 9. THE CONSULTANT REMAINS RESPONSIBLE TO
2761 ENSURE THAT ALL THE GUIDELINES, STANDARD
2913 2859 DRAWINGS, STANDARDS AND SPECIFICATIONS
SECONDARY SCHOOL
CLASS-400

OF WATER AND SANITATION DEPARTMENT HAVE


160mm∅/

2907 2878
2902 BEEN MET AND ARE COMPLIED WITH.
2760 2914
MH207 160mm∅/
CLASS-400

10. FINAL POSITION OF SERVICES TO BE


SPORTS/
160mm∅/

2883
85.57 m

16mCLASS-400
4.8

DETERMINED ON SITE.
0

2906 2879 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE


MH209

2901 20m
m

108.70 m MH210 RECREATION CONSTRUCTED AS PER COT STANDARD


2759

CLASS-400
2915

160mm∅/
DRAWING 7515-S209

83.93 m
2884 2885 2886

CLASS-400
2887 2888 2889 2890

160mm∅/
96.20 m
2891 2905 2880
2758 2911 MH300 3826
20m LEGEND
2916 2900 SEWER

CLASS-400
2899

160mm∅/
48.00 m
2898 2897 2904 2881
2896 2895 2894 2893 2930 NEW MANHOLE
2892 2912
2757 2917
MH242 CE / LH
160mm∅/
MH301

2903 2882
CLASS-400 160mm∅/ EXISTING MANHOLE
16m 2913
11.99 m CLASS-400 NEW CCTV INSPECTION
MH215

2918
LH24

63.01 m
2919 83.18 m MH216 2902
2920 2921
2922 2914
MH207 160mm∅/ EXIST. LINE INSPECTED BY CCTV

CLASS-400
2923

160mm∅/
2924 2925 2883

85.57 m
16mCLASS-400

4.8
2926 2927 2928 NEW SEWER LINE
2929

0m
MH209
2901 MH210

CLASS-400
108.70 m

160mm∅/
EXISTING SEWER LINE

36.00 m
160mm∅/
MH252

2915
2884 2885 2886
MH253

CLASS-400 160mm∅/ 2887 2888 2889 2890 HOUSE CONNECTION


CLASS-400 2891
160mm∅/ SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1330 1335 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH208 - MH210 LONGSECTION MH211 - MH212 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1325 1330

1320 1325

1315 1320
NGL NGL

SCALES: 1310
SCALES: 1315
Horizontal 1:1000 Horizontal 1:1000
Vertical 1:200 Vertical 1:200

DATUM 1305.000 DATUM 1310.000

MH211

MH212
MH208

MH207
MH209

MH210

160mmØ 160mmØ 160mmØ


REFERENCE CLASS-400 CLASS-400
REFERENCE CLASS-400
197.431

97.445
83.934
88.735

0.000
0.000

DISTANCE (m) DISTANCE (m)

1326.000

1323.423
1325.948

1322.498
1322.239

1318.809

GROUND LEVEL GROUND LEVEL

1324.345

1321.768
1324.293

1320.543
1320.463
1320.303
1320.223

1316.600

PIPE INVERT LEVEL PIPE INVERT LEVEL

1.655

1.655
2.035
2.016

2.209
1.655

1.955
1.936

DEPTH TO INVERT DEPTH TO INVERT

4.47% 3.33% 3.33% 2.65%


1:22.4 1:30.0 1:30.0 1:37.8
SLOPE / LENGTH 83.93m 4.80m 108.70m
SLOPE / LENGTH 97.45m

Q(l/s) 0.16 0.21 0.61 Q(l/s) 0.16


DESIGN DESIGN
V(m/s) 0.5 0.5 0.6 V(m/s) 0.4
HYDRAULICS Q(l/s) 27.24 23.53 23.53
HYDRAULICS Q(l/s) 20.96
MAX. (0.7D) MAX. (0.7D) 1.6
V(m/s) 2.0 1.8 1.8 V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
11 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (11 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
1:1 000
_________
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L11 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
CLASS-400
160mm∅/
40.62 m
16m SPORTS/
20m 2906 2879
NOTES AND SPECIFICATIONS
20m RECREATION
GENERAL

CLASS-400
MH241

160mm∅/
83.93 m
1. ALL MATERIAL AND WORKMANSHIP MUST
CLASS-400

2807 2808

CLASS-400
160mm∅/
58.36 m

160mm∅/
96.20 m
2905 COMPLY WITH THE REQUIREMENTS OF THE
2880 20m
2763 MH300 3826 LATEST RELEVANT SABS REQUIREMENTS.
2911 2. ALL DIMENSIONS ARE IN MILLIMETERS.
2842 (UNLESS OTHERWISE SPECIFIED).
2809 2881
2904 3. DO NOT SCALE FROM THESE DRAWINGS.
2762 2912 4. ALL DIMENSIONS MUST BE CHECKED AND
APPROVED ON SITE.
2841 2810 2882 5. ALL CONSTRUCTION TO BE DONE IN
2903
ACCORDANCE WITH THE STANDARD
MH228 2761 2913 SPECIFICATIONS FOR MUNICIPAL CIVIL
CLASS-400 ENGINEERING WORKS, THIRD EDITION 2005 AND
160mm∅/
84.20 m

2840 2811 2902 THE STANDARD COT DETAIL DRAWINGS.


MH229

16m 2760 2914


MH207 160mm∅/ 6. THESE DRAWINGS MUST BE READ IN

CLASS-400
160mm∅/
2883

85.57 m
16mCLASS-400

4.8
CONJUNCTION WITH THE STANDARD
2839

0m
DRAWINGS.(IF APPLICABLE).

MH209
2901 MH210
2812 108.70 m 7. THIS DRAWING MUST BE READ IN CONJUNCTION
2759
160mm∅/

2915 WITH THE STANDARD SPECIFICATIONS FOR


2884 2885 2886 2887 2888 2889 2890 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
2814 2891 4.
2813
2758 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
2916 2900 OF ANY DIRECTOR OF THE WATER AND

CLASS-400
2899

160mm∅/
48.00 m
2898 2897 SANITATION DEPARTMENT, IN NO WAY
2896 2895 2894 2893
MH237

160mm∅/ 2892 REMOVES ANY RESPONSIBILITY WHATSOEVER


CLASS-400 2757 2917 FROM THE CONSULTANT.
MH242
9. THE CONSULTANT REMAINS RESPONSIBLE TO
160mm∅/

MH301
49.12 m ENSURE THAT ALL THE GUIDELINES, STANDARD
CLASS-400 160mm∅/
MH243

16m DRAWINGS, STANDARDS AND SPECIFICATIONS


2753 11.99 m CLASS-400 OF WATER AND SANITATION DEPARTMENT HAVE

MH215
2754 2755 2756 2918
LH24

63.01 m BEEN MET AND ARE COMPLIED WITH.


CLASS-400

MH216
160mm∅/
36.00 m

2919 2920 2921 83.18 m 10. FINAL POSITION OF SERVICES TO BE


2922 2923 DETERMINED ON SITE.
2924 2925 2926 2927 2928 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
2929
CONSTRUCTED AS PER COT STANDARD

CLASS-400
160mm∅/
36.00 m
DRAWING 7515-S209
160mm∅/
MH252

MH244

MH253
CLASS-400 160mm∅/
CLASS-400 160mm∅/
LEGEND
62.17 m SEWER
m∅/
160m2995 CLASS-400
2994 2993 2992 76.52 m MH234 KCLIN G
160mm∅/
ASS-40FISHER ST
CLASS-400 REET 20m NEW MANHOLE
16 ASS

MH203 3055 90.75 m 0


CL

MH258
0m -4

3054 3053 3052 3051


MH202 3050
m∅ 00

82.63 m 3049 3048 91.14 m CE / LH


3047
/

3056 3046 3045


4.8

3044 3043 3042


0m

2991 3140 3141 EXISTING MANHOLE


3142 3143
160mm∅/ 3144 3145 NEW CCTV INSPECTION
3057MH153
CLASS-400 MH254 16m 160mm∅/ EXIST. LINE INSPECTED BY CCTV
2990 CLASS-400 160mm∅/
69.76 m MH255 NEW SEWER LINE
3058
96.60 m CLASS-400
3084 MH256
3085 3086 3087 EXISTING SEWER LINE
2989 3088 3089 3090 84.51 m
3091 3092 3093
3059 3139 3094 HOUSE CONNECTION
CLASS-400

MH191 3186 3187 3188 3189


160mm

16m 3190
86.01 m

3191 SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1330 LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION LH24 - MH215 75.00 m/160mmØ HDPE
Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1325

1320

1315
NGL

SCALES: 1310
Horizontal 1:1000
Vertical 1:200

DATUM 1305.000
MH215
LH24

160mmØ
REFERENCE CLASS-400
11.989
0.000

DISTANCE (m)
1321.933

1321.507

GROUND LEVEL
1319.551
1320.078

PIPE INVERT LEVEL


1.855

1.955

DEPTH TO INVERT

4.39%
1:22.8
SLOPE / LENGTH 11.99m

Q(l/s) 0.07
DESIGN
V(m/s) 0.4
HYDRAULICS Q(l/s) 27.02
MAX. (0.7D) 2.0
V(m/s)

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
12 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (12 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE: DATE:
DESIGN OFFICE APPROVAL
1:1 000
_________
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L12 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
CLASS-400
MH152

160mm∅/
63.34 m
62.49 m

MH259
3065 3133 3268 62.32 m 3244 3233 3158
16m
3109 3259 13m MH149 NOTES AND SPECIFICATIONS
13m
3202 3201 GENERAL
3066 3132 3267 3243 3234 3159 1. ALL MATERIAL AND WORKMANSHIP MUST
3110 3260

CLASS-400
160mm∅/
MH264

97.86 m
SPORTS/ COMPLY WITH THE REQUIREMENTS OF THE
13m LATEST RELEVANT SABS REQUIREMENTS.
2. ALL DIMENSIONS ARE IN MILLIMETERS.
3067 3131 3111 3266 3261 RECREATION 3242 3235 3160 (UNLESS OTHERWISE SPECIFIED).

CLASS-400
CRECHE

160mm∅/
MH281

75.67 m
MH265 3. DO NOT SCALE FROM THESE DRAWINGS.

87.51 m
4. ALL DIMENSIONS MUST BE CHECKED AND
3272

CLASS-400
3241 3273

160mm∅/
3068 3262 APPROVED ON SITE.

77.44 m
3130 3112 3265 3827 3271 3236 3161
5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
3314 SPECIFICATIONS FOR MUNICIPAL CIVIL
3240 3274

CLASS-400
3069 3129 3237 3162

160mm∅/
3264 3263 ENGINEERING WORKS, THIRD EDITION 2005 AND

48.25 m
3113
THE STANDARD COT DETAIL DRAWINGS.
6. THESE DRAWINGS MUST BE READ IN
CLASS-400

160mm∅/ 3313
160mm∅/

3239 3275 13m CONJUNCTION WITH THE STANDARD


96.20 m

3163

MH182
3070 3128 160mm∅/ 3238

MH171
3114 CLASS-400 DRAWINGS.(IF APPLICABLE).
CLASS-400 160mm∅/ 7. THIS DRAWING MUST BE READ IN CONJUNCTION

MH170
MH186

34.00 m 13m 3312 WITH THE STANDARD SPECIFICATIONS FOR


CLASS-400 160mm∅/ 3276

MH185

CLASS-400
3071 28.67 m 3164

100.32 m
MH150 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

160mm∅/
3127 CLASS-400
3115 4.
3116 3117 3118 100.89 m MH173
3119 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
3296 3297 3298 37.16 m 3311 3277 OF ANY DIRECTOR OF THE WATER AND
3299

MH172
3072 3300 3301 3302 3303 3165 SANITATION DEPARTMENT, IN NO WAY
3304

CLASS-400
3126 3305 3306 3307

160mm∅/
48.01 m
3308 3309 REMOVES ANY RESPONSIBILITY WHATSOEVER
3125 3124 3123 3122 3310 FROM THE CONSULTANT.
3121 3120 16m
3073 3278 3166 9. THE CONSULTANT REMAINS RESPONSIBLE TO

CLASS-400
3295 3294

160mm∅/
3293

48.01 m
3292 3291 ENSURE THAT ALL THE GUIDELINES, STANDARD
3290 3289 3288 3287 3286 DRAWINGS, STANDARDS AND SPECIFICATIONS
MH189 160mm∅/ 3285 3284 3283 3282 OF WATER AND SANITATION DEPARTMENT HAVE
3281

MH188
13m CLASS-400 3280 3279 3167 BEEN MET AND ARE COMPLIED WITH.
160mm∅/

MH280
10. FINAL POSITION OF SERVICES TO BE
MH190 CLASS-400 160mm∅/
107.45 m

CLASS-400
DETERMINED ON SITE.

89.62 m
3075

MH180
3076 3077 13m CLASS-400 160mm∅/ 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
3078 3079 3080 62.50 m
3081 3082 CLASS-400 CONSTRUCTED AS PER COT STANDARD
3083 3185 3184 72.58 m MH177
3168 DRAWING 7515-S209
CLASS-400

3183 3182 3181


160mm∅/

3180
36.00 m

MH169
3179 3178 41.92 m
3177

MH178
3176 3175 3174 LEGEND
3173 3172
MH279

160mm∅/ 3171 3170


MH272 3169 SEWER

CLASS-400
160mm∅/

160mm∅/
CLASS-400

36.00 m
MH273
CLASS-400 160mm∅/ SWAN STREE16T0mm∅/ NEW MANHOLE

MH274
63.28 m
55.30 m
CLASS-400 20m
CLASS-400 160mm∅/ CE / LH
3389 3390 3391 3392 55.20 m
MH183

3393 CLASS-400 160mm∅/ EXISTING MANHOLE


3394 3395 3396 3397 3398 3399 72.00 m CLASS-400
MH139 3400 3315 MH194 NEW CCTV INSPECTION
3316 77.85 m
MH125

3317 3318 3319 3320 29.08 m

MH181
160mm∅/ 3321
MH288

3322 3323 EXIST. LINE INSPECTED BY CCTV


3324 3325
MH126

CLASS-400 160mm∅/ 3326 3327

MH124
13m NEW SEWER LINE
CLASS-400 160mm∅/

MH278
63.49 m
CLASS-400 160mm∅/

MH121
EXISTING SEWER LINE
3496 3497 3498 66.01 m 13m 3328
3495 3499 3500 3501 CLASS-400
3502 3503 62.50 m HOUSE CONNECTION
3504 3505 3401 3402 63.98 m SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1320 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH199 - MH194 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


(MH274 - MH194) CROSSCUT

1315

1310

1305
NGL

SCALES: 1300
Horizontal 1:1000
Vertical 1:200

DATUM 1295.000
MH181
MH274

MH194

160mmØ 160mmØ 160mmØ


REFERENCE CLASS-400 CLASS-400 CLASS-400
607.998

679.998

757.844

786.920

DISTANCE (m)
1307.666

1306.825

1306.948

GROUND LEVEL
1305.861
1305.781

1303.911
1306.885

1304.476
1304.396

PIPE INVERT LEVEL


2.349

3.036
1.805

DEPTH TO INVERT

1.42% 1.68% 1.67%


1:70.3 1:59.7 1:60.0
SLOPE / LENGTH 72.00m 77.85m 29.08m

Q(l/s) 9.04 9.18 13.65


DESIGN
V(m/s) 1.0 1.1 1.2
HYDRAULICS Q(l/s) 15.37 16.68 16.64
MAX. (0.7D) 1.2 1.3 1.2
V(m/s)

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
13 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (13 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE: DATE:
DESIGN OFFICE APPROVAL
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L13 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
MH191
2857

2858

2859

MH139
3390
87.51 m CLASS-400

3524
2911

3525
3495
2912

3055
LH24

20m

3057MH153

3523
16m

MH189
2913

3522

3521
2914

MH264
160mm∅/ NOTES AND SPECIFICATIONS

2915

2916

3520

3562
96.20 m

2917

2918

3593

3592
3076

3591
CLASS-400

3590
MH252

3056

3389
160mm∅/ GENERAL
EAGLE STREET

3058

3059

3060

3061
100.17 m CLASS-400

3063
3062

MH272
1. ALL MATERIAL AND WORKMANSHIP MUST
2 5m

13m
3064

3065

MH286
3066

3067

3075
COMPLY WITH THE REQUIREMENTS OF THE

3068

3069
103.98 m

3070
LATEST RELEVANT SABS REQUIREMENTS.

3071

3072

3073

3388
2. ALL DIMENSIONS ARE IN MILLIMETERS.

3074

3387

3386

3385
(UNLESS OTHERWISE SPECIFIED).

3384

3383

3382

3381

3380
3. DO NOT SCALE FROM THESE DRAWINGS.

CLASS-400

3379

3378

3377
2702

2701

3376
160mm∅/
2700

3375
4. ALL DIMENSIONS MUST BE CHECKED AND

62.17 m
2699
MH220 EAGLE STREET

3374
MH240 2698
2703

160mm∅/

2697
APPROVED ON SITE.
160mm∅/
25m

20m

2763
CLASS-400

2762

2761
160mm∅/ 5. ALL CONSTRUCTION TO BE DONE IN

2760
LH2

2759
CLASS-400

2758

MH242
ACCORDANCE WITH THE STANDARD

2757
CLASS-400 160mm∅/

CLASS-400
MH241
14.94 m

2991
SPECIFICATIONS FOR MUNICIPAL CIVIL

160mm∅/
46.82 m

74.26 m
CLASS-400

2990

2989
19.70 m

16m
ENGINEERING WORKS, THIRD EDITION 2005 AND

2988
40.62 m /
EAGLE STREET

2756

2987

2986
m∅ 400

MH270 2985
THE STANDARD COT DETAIL DRAWINGS.

2984
160mm∅/

2983

2982
16m
2704

MH243
32

MH202
84.20 m m

2981
0 - m

2979
2980
6. THESE DRAWINGS MUST BE READ IN
16 ASS

2992
CLASS-400

2978
MH203
160mm∅/
MH219

MH206

2977

2975
160mm∅/ CONJUNCTION WITH THE STANDARD

2976
CL 0m

2974
CLASS-400

MH201
DRAWINGS.(IF APPLICABLE).
2764

MH244
2765

MH237 4.8 86.01 m CLASS-400 160mm∅/


2766
2705

7. THIS DRAWING MUST BE READ IN CONJUNCTION

2767

16m
2808
36.00 m CLASS-400 WITH THE STANDARD SPECIFICATIONS FOR

2809

3608
2810

3609
2755
86.01 m

2811

3611

3612
3610
2993
2812
MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

3613
2973

3614
43.58 m

3615

3616

3617
MH200 160mm∅/ 4.

3618
2706

3619
3607
160mm∅/

3620
8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
160m -400

CLASS-400

3621
2768
m

CLASS-400

2754

3622
CLASS-400 160mm∅/ OF ANY DIRECTOR OF THE WATER AND

2807

2994

MH103
m∅/

160mm∅/
51.93

MH195
49.12 m
2813
2842
MH196

2841
S

2840
SANITATION DEPARTMENT, IN NO WAY
99.78 m CLASS-400

MH228
CLAS

160mm∅/
2707

REMOVES ANY RESPONSIBILITY WHATSOEVER

2972

MH291
36.00 m
CLASS-400 MH223
CRECHE

CLASS-400

3020

3606
3021
FROM THE CONSULTANT.

2753
107.51 m

3022
2769

CLASS-400
2996160m2995
9. THE CONSULTANT REMAINS RESPONSIBLE TO

m∅/

82.63 m

3686
2806

COMMUNITY
58.36 m

2839
16m

3687
ENSURE THAT ALL THE GUIDELINES, STANDARD

3688
MH229

3689
2814

2971
2708

FACILITY

3692
3690

3691
160mm∅/ DRAWINGS, STANDARDS AND SPECIFICATIONS

3605

3694
2771 16 2770

3685

3693
0mm∅/

2752

3695
34.54 m

OF WATER AND SANITATION DEPARTMENT HAVE


MH221

CLASS-400

3696
3023
3019
16m

3698
MH231

3697
MH230 BEEN MET AND ARE COMPLIED WITH.
2709

CLASS-400
10. FINAL POSITION OF SERVICES TO BE

2970

CLASS-400
47.93 m

3726
RECREATION

103.37 m
160mm∅/
2838

2815

3725

3724
160mm∅/
3604
DETERMINED ON SITE.

83.28 m

3723
SPORTS/

2751

3722
160mm∅/

3018
3000

3721
3684
11. ALL SEWER LONG HOUSE CONNECTIONS TO BE

2997

3727

3720
CLASS-400
3024
160mm∅/

3719

3718

MH161
CLASS-400 CONSTRUCTED AS PER COT STANDARD

3716
3717
160mm∅/

88.50 m
2710

CLASS-400 160mm∅/

2969
DRAWING 7515-S209
10.15 m

MH225

2837

2816

3603

MH157
CLASS-400

2750
8.02 m

3683
2772

51.55 m

2998

3728
3017

3025

13m
LH18

MH292
LEGEND

3715
2711

63.66 m
3825

6
CLASS-400
22

MH204
2805

2968
MH SEWER

2836

3602
160mm∅/

2817
72.73 m

2749

3681 3682

3729
3016
2773

3026
NEW MANHOLE

2999
MH104
2712

CLASS-400

CLASS-400
2804

2967
2835
13m

3714
2818

160mm∅/

COMMUNITY
89.40 m
m

CE / LH

160mm∅/

60.40 m
160 SS-400

3601

FACILITY
2748

3730
.54

2774

3015

3027
/
mm∅

EXISTING MANHOLE
2713

MH290
0

2834
160mm∅/
1
CLA

2966
2803

2819

3713
3680
NEW CCTV INSPECTION

13m CLASS-400
3731
3600
CLASS-400

3813
2775

2747

160mm∅/

51.01 m
3014

MH269
16m

3028
2714

MH193 EXIST. LINE INSPECTED BY CCTV

MH192
2833
2802

2820 29.88 m

13m
3679
2965

3712
m
160 SS-400

NEW SEWER LINE


2776

3732
MH266

3599
m
9.91

2746

3013
913
/
mm∅
2715

3029
EXISTING SEWER LINE
2801

2821
2832

MH156
CLA

3678
2964

3733
2777

HOUSE CONNECTION

3711
13m

20m

3598
2932
2745
2716

Tm

3012

3030
SUBURB BOUNDARY

E0
PIPE NUMBER

R E2
04100823
DIRECTION OF FLOW

TT
1330 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH204 - MH196 Class PE100 PN 6, SDR26

E RESE
SLEEVE Ø TYPE CLASS

HR
I ST
G FS CROSSCUT

1325
I NR
KINGFISHK E

1320

1315
NGL

SCALES: 1310
Horizontal 1:1000
Vertical 1:200

DATUM 1305.000

MH201
MH204

MH203
MH202

MH270

MH206

MH200

MH196
160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400
259.451
173.441

303.033
307.888

317.308
87.431
82.630
0.000

DISTANCE (m)
1324.008

1321.692
1321.473

1318.054

1315.376

1314.072
1314.029

1314.214
GROUND LEVEL
1322.352

1313.402
1313.322

1311.314
1320.037
1319.957
1319.818
1319.738

1316.249
1316.169

1311.617
1311.488
1311.537
1311.408

PIPE INVERT LEVEL


2.541
2.621
2.054

2.455
2.535

2.900
1.655

1.655
1.655
1.735
1.735

1.805
1.885

1.974

DEPTH TO INVERT

2.80% 2.90% 4.06% 3.22% 3.91% 1.00%1.00%


1:35.7 1:34.5 1:24.7 1:31.1 1:25.5 1:100.0
1:100.0
SLOPE / LENGTH 82.63m 4.80m 86.01m 86.01m 43.58m 4.86m9.42m

Q(l/s) 0.16 0.19 0.35 0.49 5.64 5.67 5.67


DESIGN
V(m/s) 0.4 0.4 0.6 0.6 1.3 0.8 0.8
HYDRAULICS Q(l/s) 21.57 21.94 25.96 23.11 25.50 12.8912.89
MAX. (0.7D) 1.6 1.6 1.9 1.7 1.9 1.0 1.0
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
14 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (14 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L14 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
EAGLE STREET

EAGLE STREET
2931 FACILITY 2987 2931 FACILITY 2987
3061 3061 NOTES AND SPECIFICATIONS
GENERAL
16m 2986 16m 2986 1.
ALL MATERIAL AND WORKMANSHIP MUST
3062 3062 COMPLY WITH THE REQUIREMENTS OF THE
LATEST RELEVANT SABS REQUIREMENTS.

87.51 m

87.51 m
2. ALL DIMENSIONS ARE IN MILLIMETERS.
MH270 2985 MH270 2985 (UNLESS OTHERWISE SPECIFIED).
3063 3063
3. DO NOT SCALE FROM THESE DRAWINGS.
4. ALL DIMENSIONS MUST BE CHECKED AND
3000 16m 2984 3000 16m 2984 APPROVED ON SITE.
3064 3064 5. ALL CONSTRUCTION TO BE DONE IN
ACCORDANCE WITH THE STANDARD
SPECIFICATIONS FOR MUNICIPAL CIVIL
2983 2983

25m

25m
ENGINEERING WORKS, THIRD EDITION 2005 AND
3065 3065 THE STANDARD COT DETAIL DRAWINGS.
16m 16m 6. THESE DRAWINGS MUST BE READ IN
2982 2982 CONJUNCTION WITH THE STANDARD
3066 3066 DRAWINGS.(IF APPLICABLE).

CLASS-400

CLASS-400
160mm∅/

160mm∅/
86.01 m

86.01 m
MH264 MH264 7. THIS DRAWING MUST BE READ IN CONJUNCTION
WITH THE STANDARD SPECIFICATIONS FOR
2981 2981
2944
MH192 2944
MH192 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES
2943 2942 2941 3067 2943 2942 2941 3067 4.
2940 2939 2938 2937 2940 2939 2938 2937 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,
2945 2936 2935 2934 2945 2936 2935 2934
2933 2932 2980 2933 2932 2980 OF ANY DIRECTOR OF THE WATER AND

CLASS-400

CLASS-400
SANITATION DEPARTMENT, IN NO WAY

160mm∅/

160mm∅/
MH205

MH205
29.88 m

29.88 m
MH199 3068 MH199 3068
REMOVES ANY RESPONSIBILITY WHATSOEVER
160mm∅/ 160mm∅/
MH267

MH267
FROM THE CONSULTANT.
CLASS-400 160mm∅/ 2979 CLASS-400 160mm∅/ 2979 9. THE CONSULTANT REMAINS RESPONSIBLE TO
16m 16m
CLASS-400 160mm∅/ 3069 CLASS-400 160mm∅/ 3069 ENSURE THAT ALL THE GUIDELINES, STANDARD
74.41 m 74.41 m DRAWINGS, STANDARDS AND SPECIFICATIONS
80.44 m CLASS-400 80.44 m CLASS-400
CLASS-400

CLASS-400
3001 2978 3001 2978 OF WATER AND SANITATION DEPARTMENT HAVE
160mm∅/

160mm∅/
3002 3002
51.67 m

51.67 m
3003 3004 3003 3004

CLASS-400

CLASS-400
3005 3005

MH193

MH193
3006 3007 MH206 3006 3007 MH206 BEEN MET AND ARE COMPLIED WITH.
3009 3009

96.20 m

96.20 m
3008 3010 3011 103.37 m 3070 3008 3010 3011 103.37 m 3070 10. FINAL POSITION OF SERVICES TO BE
3012 3012
3013 3014 3015 3016 3013 3014 3015 3016 DETERMINED ON SITE.
3017 3018 3020 3017 3018 3020
3041 3019 2977 3041 3019 2977 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE
3040 3039 3038 3071 3040 3039 3038 3071 CONSTRUCTED AS PER COT STANDARD
3037 3036 3035 3037 3036 3035 DRAWING 7515-S209
3034 3034

CLASS-400

CLASS-400
3033 3032 3033 3032

160mm∅/

160mm∅/
43.58 m

43.58 m
3031 3030 3021 3031 3030 3021
3029 3029
16 ASS MH1

16 ASS MH1
3028 3027 3026 3028 3027 3026
CL

CL
3025 3025 LEGEND
0m -4

0m -4
160mm∅/ 3024 2976 160mm∅/ 3024 2976
3023 3072 3023 3072
m∅ 00

m∅ 00
CLASS-400 3022 CLASS-400 3022 SEWER
/

/
4.8

4 .8
MH268 160mm∅/ MH268 160mm∅/
1m 7

1m 7
CLASS-40
130m 160mm∅/ 2975 CLASS-40
130m 160mm∅/ 2975 NEW MANHOLE
91.47 m MH269 91.47 m MH269

MH196

MH196
3073 3073
2951 CLASS-400 2951 CLASS-400
9

9
2952 2953 87.50 m 2952 2953 87.50 m CE / LH
2954 2955 2956 MH201 2954 2955 2956 MH201
2957 2958 2957 2958
2959 2960 2962
88.50 m 2974 MH189 2959 2960 2962
88.50 m 2974 MH189 EXISTING MANHOLE
2961 2963 2964 2965 2961 2963 2964 2965

MH200

MH200
2966 2967 2968 3074 2966 2967 2968 3074
2969 2970 2969 2970 NEW CCTV INSPECTION
2971 2972 2973 2971 2972 2973

CLASS-400

CLASS-400
160mm∅/

160mm∅/
3075 3075 EXIST. LINE INSPECTED BY CCTV

36.00 m

36.00 m
SWAN STREET 3076
SWAN STREET 3076
2 0m 20m NEW SEWER LINE

EXISTING SEWER LINE


3666 3667 3668 160mm∅/ 3666 3667 3668 160mm∅/
3669 3670 MH195 3669 3670 MH195 HOUSE CONNECTION
MH141 3671 3672 CLASS-400 MH141 3671 3672 CLASS-400
3594 3595 MH272 3594 3595 MH272
3596 3597 3596 3597 SUBURB BOUNDARY

04100823 PIPE NUMBER


1330 DIRECTION OF FLOW
LONGSECTION MH205 - MH206 1325 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION LH10 - MH193 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS


CROSSCUT

1325
1320

1320
1315

1315
1310
NGL NGL

SCALES: 1310 SCALES: 1305


Horizontal 1:1000 Horizontal 1:1000
Vertical 1:200 Vertical 1:200
DATUM 1305.000 DATUM 1300.000
MH205

MH267

MH193

MH206
160mmØ 160mmØ 160mmØ

MH192

MH193
REFERENCE CLASS-400 CLASS-400 CLASS-400 REFERENCE 160mmØ
CLASS-400
154.841

258.215
74.405
0.000

29.881
DISTANCE (m)

0.000
DISTANCE (m)
1320.320

1318.604

1317.084

1315.376

1318.230

1317.084
GROUND LEVEL GROUND LEVEL
1318.378

1316.698
1316.618

1315.228
1315.148

1313.402

1316.575

1315.228
PIPE INVERT LEVEL PIPE INVERT LEVEL
1.942

1.905
1.985

1.855
1.936

1.974

DEPTH TO INVERT

1.655

1.856
DEPTH TO INVERT

2.26% 1.73% 1.69%


1:44.3 1:57.9 1:59.2 4.51%
SLOPE / LENGTH 74.41m 80.44m 103.37m SLOPE / LENGTH 1:22.2
29.88m

Q(l/s) 0.33 0.58 5.04


DESIGN Q(l/s) 3.09
V(m/s) 0.5 0.5 0.9 DESIGN
HYDRAULICS V(m/s) 1.2
MAX. (0.7D)
Q(l/s) 19.36 16.94 16.75 HYDRAULICS Q(l/s) 27.36
V(m/s) 1.5 1.3 1.3 MAX. (0.7D)
V(m/s) 2.1

WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:


AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
15 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (15 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L15 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
AGLE STREET 3
20

CLASS-400
SWAN STREET

3595
45.00 m 13m

13m
FACILITY 3723

CLASS-400

/
3691

3797

3637

160mm∅/
3657

3674
3782 3381

72.00 m
NOTES AND SPECIFICATIONS

3789
3754

CLASS-400
3812
3615

3737
13m

3811

3810

160mm∅/

34.85 m
2960
MH294

3809

3808
MH99
160mm∅/ 3810

020
3793 GENERAL

3594
MH101

3766

3767
CLASS-400 13m 13m 3722 MH286

2401/2
3781 MH293 3813 3692

3673

3807
1. ALL MATERIAL AND WORKMANSHIP MUST

3738
3755 3616 3380

3638
MH292

3798
MH289 COMPLY WITH THE REQUIREMENTS OF THE

MH100
160mm∅/
2959

pipe
13m
70.69 m 3809 MH291

CLASS-400
MH98 160mm∅/ 3794 LATEST RELEVANT SABS REQUIREMENTS.

MH98
3765
CLASS-400

R.O.W Servitude S.G. No.

MH96
160mm∅/

65.02 m
3768
MH268

MH96 3780 CLASS-400 3721 2. ALL DIMENSIONS ARE IN MILLIMETERS.


3756 3379

16m
MH97 3693

3639
MH99 3617 (UNLESS OTHERWISE SPECIFIED).

3806
45.00 m
2958

3799
3. DO NOT SCALE FROM THESE DRAWINGS.

CLASS-400
38.50 m

CLASS-400
3808 3795

160mm∅/

2m
59.64 m
3764

13m
160mm∅/

RECREATION
4. ALL DIMENSIONS MUST BE CHECKED AND

51.48 m

3769
CLASS-400
3779 3720 3694 APPROVED ON SITE.

SPORTS/
3757 3378

160mm∅/
3803 3804

38.50 m

3640
3806 3618

CLASS-400
MH296 3805

3672

160mm∅/
3807 5. ALL CONSTRUCTION TO BE DONE IN

3744

63.76 m
3805

CLASS-400
3745

3800

160mm∅/
2957

63.66 m
ACCORDANCE WITH THE STANDARD
3796

3763

CLASS-400
130m

3770

160mm∅/
3829
SPECIFICATIONS FOR MUNICIPAL CIVIL

45.00 m
CLASS-400
3778 3758 3719
3695 3377

160mm∅/
3619

CLASS-40

3641
3802 ENGINEERING WORKS, THIRD EDITION 2005 AND

79.44 m
3801

160mm∅/

60.60 m
3743

3804
3800

3801
3746
3671 3799
2956

3798 THE STANDARD COT DETAIL DRAWINGS.


3797 6. THESE DRAWINGS MUST BE READ IN

3762

CLASS-400
MH295

3771
3777

103.98 m
MH100 3718 3696 CONJUNCTION WITH THE STANDARD
3376

3642
MH148 160mm∅/

3742
3620
CLASS-400

DRAWINGS.(IF APPLICABLE).

3747
3759
MH146

MH142

CLASS-400
3803

MH106
3670

160mm∅/
2955

3802

107.51 m
160mm∅/

160mm∅/
CLASS-400
91.47 m

7. THIS DRAWING MUST BE READ IN CONJUNCTION

4.8
13m

CLASS-400
CLASS-400

3761

MH104
3776

3772
MH147
160mm∅/ WITH THE STANDARD SPECIFICATIONS FOR

160mm∅/
MH144

72.04 m

1
3717 3697

m 145
MH294
60.60 m

MH
MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

3741
160mm∅/ 13m CLASS-400

13m
3621

3643
34.85 m MH161

3748

MH97
3375 4.
2954

3669

CLASS-400 160mm∅/ 3760 8. THE SIGNATURE OR INITIALS ON THIS DRAWING,


3761 3762 3763 51.01 m
CLASS-400 3764

3773
3765 3716 OF ANY DIRECTOR OF THE WATER AND
3740
3766

CLASS-400
MH145

3760
59.93 m 3709 3698

3749

3644
3710 3622
1m
SANITATION DEPARTMENT, IN NO WAY

3751

160mm∅/
3750

69.23 m
3775 3711

3752
59.64 m 3712
2953

3713
3668

4.8

3753

3754
3714 REMOVES ANY RESPONSIBILITY WHATSOEVER

3755
3374

CLASS-400
MH102

3756
3774

MH146
3715

3758
3757

160mm∅/
13m

45.00 m
3773 3772 FROM THE CONSULTANT.

3759
3771

3774
3770

CLASS-400
3769 3699 9. THE CONSULTANT REMAINS RESPONSIBLE TO

160mm∅/
3767

45.00 m
3739

3768 3708 3623

3645
3707 ENSURE THAT ALL THE GUIDELINES, STANDARD
2952

3706
3788
3667

3705
3787 3704

3786
3703

3785
160mm∅/ DRAWINGS, STANDARDS AND SPECIFICATIONS

3784

MH295
3783
3702

3782
160mm∅/ 3701 3373

3781
OF WATER AND SANITATION DEPARTMENT HAVE
MH141

3700

3780
∅/ 0 CLASS-400 160mm∅/

3779

3778
mm S-40 CLASS-400

3777

3775
3624

3776
160mm∅/ BEEN MET AND ARE COMPLIED WITH.

3646

MH164
0 CLASS-400
13m 160mm∅/ MH138
16 AS MH1 CLASS-400 69.23 m 10. FINAL POSITION OF SERVICES TO BE

MH140

MH165
2951

160mm∅/
3666

9 77.44 m CLASS-400 160mm∅/


CL 1m 7
DETERMINED ON SITE.
CLASS-400 65.02 m

MH297
. 8 CLASS-400 MH163 11. ALL SEWER LONG HOUSE CONNECTIONS TO BE

13m
MH198

72.00 m

MH143
4 3372

3647
78.01 m 3625 CONSTRUCTED AS PER COT STANDARD
2950

MH296
72.04 m MH140 3647 3646
3645 3642 3640 DRAWING 7515-S209
3643 3641 51.96 m
3665

3664

MH105
3644 3639 3638
3663

3662

3637 3636
3661

20
3635 3634 160mm∅/
3659
3660

3633 3632 LEGEND

3658

.4 8
3657
pipe 3371 3370

3656
3631

3655
3630 3629 3628 3627 CLASS-400

3654

3653
3626

m
3652
SEWER

3651

3650

3649

3648
41.75 m

MH167
widening NEW MANHOLE
10m Servitude - future road

MH166
CE / LH
R.O.W Servitude S.G. No.
2401/2020

J
EXISTING MANHOLE

NEW CCTV INSPECTION


EXIST. LINE INSPECTED BY CCTV

NEW SEWER LINE


EXISTING SEWER LINE

K
HOUSE CONNECTION

SUBURB BOUNDARY

04100823 PIPE NUMBER


DIRECTION OF FLOW
1320 75.00 m/160mmØ HDPE LENGTH,DIAMETER & MATERIAL/CLASS
LONGSECTION MH141 - MH95 Class PE100 PN 6, SDR26

SLEEVE Ø TYPE CLASS

(MH141 - MH166) CROSSCUT

1315

1310

1305
NGL

SCALES: 1300
Horizontal 1:1000
Vertical 1:200

DATUM 1295.000
MH141

MH297

MH296

MH140

MH295

MH143

MH105

MH165
MH164

MH167

MH166
160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ 160mmØ
REFERENCE CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400 CLASS-400

290.711
149.441

433.744

485.707
489.864
221.484

355.733

510.347

552.096

640.423
77.441
0.000

DISTANCE (m)
1312.271
1316.898

1314.663

1310.263

1309.498

1308.810

1307.804

1307.056
1307.083

1306.757

1306.295
GROUND LEVEL

1304.884
1304.804
1304.762
1304.682

1303.980
1303.900
1314.476

1311.886
1311.806

1310.497
1310.417

1308.387
1308.308

1307.393
1307.313

1306.663
1306.583

1305.706
1305.626

1304.478
1304.398

1303.017
PIPE INVERT LEVEL
2.421

2.858

2.185

2.227

2.178

2.252
2.400

2.359

2.394
1.854

1.955

DEPTH TO INVERT

3.35% 1.82% 2.82% 1.32% 1.00% 1.12% 1.43% 1.00% 1.00% 1.00% 1.00%
1:29.9 1:55.0 1:35.5 1:75.7 1:100.1 1:89.0 1:70.0 1:100.0 1:100.0 1:100.0 1:100.0
SLOPE / LENGTH 77.44m 72.00m 72.04m 69.23m 65.02m 78.01m 51.96m 4.16m 20.48m 41.75m 88.33m

Q(l/s) 0.30 0.56 0.77 1.00 1.21 2.83 4.14 4.14 5.72 5.77 5.93
DESIGN
V(m/s) 0.5 0.5 0.6 0.5 0.5 0.7 0.8 0.7 0.8 0.8 0.8
HYDRAULICS Q(l/s) 23.57 17.38 21.63 14.82 12.88 13.66 15.40 12.89 12.89 12.89 12.89
MAX. (0.7D) 1.8 1.3 1.6 1.1 1.0 1.0 1.2 1.0 1.0 1.0 1.0
V(m/s)
WATER AND SANITATION DESIGNED CONTRACT PROJECT STATUS LOCATION OF PROJECT:
AMENDMENTS FOR INTERNAL APPROVAL - RECEIVED SIGN WHEN APPLICABLE
CONSULTANT DETAIL NAME: SAGWADI RINGANI Prof Reg No: No: RECEIVED SIGN WHEN APPLICABLE
_________
HHS01-2018/19 ANDEON EXT 37
NR DATE APPROVED DESCRIPTION PAR DIRECTOR: WATER AND SANITATION - PLANNING SIGNATURE: DATE: REGION 3
Plot 70 PROJECT No. WARD 55
0 19-Oct-23 APPROVED FOR CONSTRUCTION NAME Prof. Reg. No SIGNATURE DATE 1463 Tienie Street DRAWN CONCEPT TENDER APPROVED AS BUILT
REGIONAL DIRECTOR: (1,2,3,4,5,6 or 7) Andeon Ah NAME: MOEMEDI MOTAI _________ DRAWING DRAWING CONSTRUCTION
DRAWING
DRAWING
DESCRIPTION OF PROJECT:
Zandfontein
Pretoria West SIGNATURE: DATE: SHEET No. PROJECT ENGINEER of COT:
NAME Prof. Reg. No SIGNATURE DATE
0183
CONSTRUCTION OF SEWER SERVICES IN ANDEON EXT 37
DIRECTOR: SYSTEM DEVELOPMENT CHECKED _________
16 OF 38
PO BOX 1022 Tel: 012 372 3708 SEWER LAYOUT AND LONGSECTION (16 OF 38)
PRETORIA NAME: THAMI TOM Prof Reg No: 2018300095 NAME: Pr Eng. Prof Reg No:
NAME Prof. Reg. No SIGNATURE DATE 19-Oct-23 PAPER SIZE:
0001 THAMI TOM
I, ___________________ 2018300095
Prof Reg Nr__________________ SIGNATURE: DATE:
DIRECTOR: BULK WATER HEREBY CERTIFY THAT THE SERVICES WILL\ HAVE BEEN INSTALLED A1
INFORMATION OFFICE CHECKED _________ SIGNATURE: DATE:
CITY OF TSHWANE NAME Prof. Reg. No SIGNATURE DATE
ACCORDING TO NOTE 9 OF THE ABOVE NOTES AND TO THE
DRAWING NAME: Prof Reg No: SCALE: INSPECTOR OF WORKS of COT:
DIRECTOR: INFRASTRUCTURE PROVISION
WATER AND SANITATION WBS No. :
DEPARTMENT NAME Prof. Reg. No SIGNATURE DATE
SIGNATURE
__________________ ________
19-Oct-23
DATE SIGNATURE:
DESIGN OFFICE APPROVAL
DATE:
_________
1:1 000
NAME: Prof Reg No:
_-______-_-___-_-_
DIRECTOR: WASTE WATER TREATMENT DATE:
CONSULTANT DRAWING NUMBER: NAME: Prof Reg No: COT DRAWING NUMBER:
__________________
2022-AND-S-04L16 0
SIGNATURE: DATE:
19-Oct-23
_________ SIGNATURE: DATE: 0
NAME Prof. Reg. No SIGNATURE DATE REVISION DESCRIPTION OF PROJECT: REVISION
AGLE STREET 3
CLASS-400

CLASS-400
100.38 m
13m MH285

∅/

widening
FACILITY 3723 13m 3458

CLASS-400
CLASS-400

/
3691 SPORTS/ 3415

3543
3521

160mm∅/
3541
3518

160mm∅/
3657 3782 3381

52.88 m
3542
72.00 m
3754 3615 NOTES AND SPECIFICATIONS

3540

3539
13m

3536
3538

3537
3333

3535

EAGLE STREET
MH294 3486
3810 3793 3484
RECREATION 3473 3457 GENERAL

10m Servitude - future road


3781 13m 13m 3722 3692 MH286 3520 3416
3755 MH293 3813
MH292 3616 3380 3519 MH287 16m 1. ALL MATERIAL AND WORKMANSHIP MUST

MH129
3334 COMPLY WITH THE REQUIREMENTS OF THE

MH100
3809 MH291 3487
160mm∅/ 3794 160mm∅/ 3483 LATEST RELEVANT SABS REQUIREMENTS.

MH98
3474

MH96
3780 CLASS-400 3721 13CL
m ASS- 3456 3417 2. ALL DIMENSIONS ARE IN MILLIMETERS.
3756 3693 3379 400 (UNLESS OTHERWISE SPECIFIED).
MH99 3617 3828 3488 3335

CLASS-400
MH130 3. DO NOT SCALE FROM THESE DRAWINGS.

1013

CLASS-400
38.50 m 97.63 m 3482

CLASS-400

160mm∅/
3808 3795

102.46 m

160mm∅/
13m

160mm∅/

2m
3475

59.64 m
4. ALL DIMENSIONS MUST BE CHECKED AND

5.85
3545

3546

CLASS-400
3544
3455

3547
3779 3720 3418

3548
3694

250mm∅/
87.51 m
3549

3550
3378 APPROVED ON SITE.

mm
3757 3803

3551
CLASS-400
3804

3552
3806 3618

CLASS-400
MH296 3805

160mm∅/
3562

58.80 m
3807

160mm∅/
3489 3336 5. ALL CONSTRUCTION TO BE DONE IN

63.76 m

CLASS-400
3563 MH123

160mm∅/
63.66 m
3481 3476 ACCORDANCE WITH THE STANDARD
3796

CLASS-400
13m

160mm∅/
SPECIFICATIONS FOR MUNICIPAL CIVIL

45.00 m
3778 3758 3719 3454
3802 3695 3619 3377 3419 ENGINEERING WORKS, THIRD EDITION 2005 AND

CLASS-400
3801

3561

160mm∅/
3593 3564

53.00 m
3800 3337

3559
3560
3799 3798 THE STANDARD COT DETAIL DRAWINGS.

3558

3557

3556

3554
3480

3555
3797 3490 3477 6. THESE DRAWINGS MUST BE READ IN

3553

32m
CLASS-400
3777

103.98 m

160mm∅/
3718 3696 3453 3420 CONJUNCTION WITH THE STANDARD
160mm∅/ 3376
3759 3620 3592 3565 3494 3493 3338 DRAWINGS.(IF APPLICABLE).
MH146

MH142

CLASS-400
3492

MH106
160mm∅/

107.51 m
3491

160mm∅/
CLASS-400 3479 7. THIS DRAWING MUST BE READ IN CONJUNCTION
4.8

160mm∅/

MH276
13m
CLASS-400

CLASS-400 3478

MH104
3776 160mm∅/ WITH THE STANDARD SPECIFICATIONS FOR
160mm∅/

MH144 MH134
72.04 m

3717 3697 CLASS-400 160mm∅/ 3452 3421


m 145

60.60 m
MH

13m CLASS-400 MUNICIPAL CIVIL ENGINEERING WORKS, SERIES

MH111
4.1
34.85 m MH161 3621 3591 13m CLASS

You might also like