Features

Fast Data Logging Recorder Real-Time Clock & Synchronization Digital & Analog I/O Options
‡‡ From ½ cycle RMS to 2-hour envelopes ‡‡ Real-Time Clock with maximum 5 3 expansion slots for a wide range of
‡‡ Programmable post fault on any seconds drift per month @ 25°C plug-in modules:
internal and/or external trigger ‡‡ Provides 1 msec time resolution via ‡‡ 16 high speed digital inputs, total up

condition IRIG-B time code input or satellite to 48 DIs


clock for common time base (requires ‡‡ 8 dry contact relay outputs, total up to

Waveform Capture IRIG-B module) 24 ROs


‡‡ Provides simultaneous capture for all ‡‡ As an SNTP client, it can accept ‡‡ Mixed 4 analog inputs and 4 outputs,

voltage and current channels with periodic synchronization of the meter total up to 12 AI/12AO
choice of sample rate, up to 256 (1024 clock from an SNTP server
with Transient Module). Selectable ‡‡ Time sync from digital input with 1ms Logging, Recording & Programming
pre-fault / post-fault recording length. accuracy ‡‡ Standard onboard memory: 256 MB
Disturbance capture recording up to ‡‡ Programmable controller: up to 64
several minutes Wide Range Voltage Inputs control setpoints, up to 8 conditions
‡‡ Transient capture (>78/65μs—50/60Hz) ‡‡ Three impulse galvanic isolated AC OR, AND, arithmetical functions logic,
voltage inputs extensive triggers, programmable
Harmonic Analyzer ‡‡ Impulse dielectric withstand 6kV thresholds and delays, relay control,
‡‡ Total Harmonic Distortion for Voltage ‡‡ Wide range application up to 828V event-driven data recording
and Current and up to the 63rd ‡‡ AC/DC voltage input: station battery ‡‡ 8 fast waveform recorders:
individual harmonic for V, I, P, Q monitoring (up to 300V DC) simultaneous 8-channel AC, one DC:
‡‡ Including directional power harmonics up to 48 digital inputs in a single plot
(Load or Source) Wide Range Current Inputs ‡‡ Waveform sampling rate 32, 64, 128
‡‡ V-I angle, TDD and K factors ‡‡ 4 dual purpose current inputs (3-phase or 256 samples per cycle; up to 20 pre-
+ Neutral)—1A/5A for measurement fault cycles (2 cycles of 1024 samples
Multi-Function Power CTs with Class 0.2S revenue grade per cycle or 4 cycles with 512 samples
& Energy Meter accuracy to 10A/20A and 50A/100A per cycle with Transient Module)
‡‡ Real time cycle-by-cycle measurement (5A/HACS) for protection CTs (10/20x) ‡‡ Up to 3.5 min. of continuous waveform
of high accuracy, true RMS voltage, recording
current, power, demand and energy Communication Platforms ‡‡ 1-ms resolution for digital inputs
‡‡ Revenue accurate meter ‡‡ 3 independent built-in Ports plus 3 ‡‡ 16 fast Data Recorders
‡‡ Exceeding Class 0.2S (IEC 62053-22 / optional: (16 parameters on each data log):
ANSII C12.20) ‡‡ IRIG-B and RS-422/485 port From ½ cycle RMS to 2 hour RMS
‡‡ Advanced Time Of Use (TOU) feature ‡‡ TXFX (fiber optic) envelopes; up to 20 pre/post-fault
(16 Energy sources include external ‡‡ 2G/3G cellular modem cycles; programmable data logs on
digital pulses, up to 4 seasons, 4 daily ‡‡ Communication Protocols: a periodic basis and on internal or
profiles, 8 Tariffs, flexible automatic Modbus RTU, ASCII, DNP 3.0, external trigger
calendar) for any complex billing Modbus/TCP, DNP3/TCP, IEC 61850 ‡‡ 32 digital internal counters
scheme (option), IEC 60870-5-101/104 ‡‡ 16 internal programmable timers
‡‡ KYZ or KY output and LED indication (½ cycle to 24 hours)
for calibration and test (via optional
display)
‡‡ Vector diagram and symmetrical
components