Professional Documents
Culture Documents
User Manual - ASSA ABLOY - RD300-3 and RD300-4 - en
User Manual - ASSA ABLOY - RD300-3 and RD300-4 - en
Revolving Doors
ASSA ABLOY RD300-3, RD300-4 (CDC 4)
CONTENTS - Original instructions
Instructions for safe operation ....................................................................................................... 4
Congratulations on your new automatic door! ........................................................................ 5
Electronic equipment reception interference ........................................................................... 5
Environmental requirements .......................................................................................................... 5
Product liability ................................................................................................................................... 5
Warranty ................................................................................................................................................ 6
Service ..................................................................................................................................................... 6
Intended use ......................................................................................................................................... 7
Technical specification ...................................................................................................................... 7
How the ASSA ABLOY RD300-3 and ASSA ABLOY RD300-4 work ...................................... 7
Main parts .............................................................................................................................................. 8
Settings and operation PCD ............................................................................................................ 9
General information PCD ....................................................................................... 9
Information prompts on PCD display ................................................................ 9
Access code ................................................................................................................. 10
Changing operating mode ..................................................................................... 11
Real time operation ................................................................................................. 13
Safety ....................................................................................................................................................... 16
Safety device on the door ...................................................................................... 16
Pressure sensitive safety edges ............................................................................. 17
Force sensitive door leaves .................................................................................... 17
Emergency stop button (inside) .......................................................................... 17
Regular safety checks ......................................................................................................................... 18
Troubleshooting .................................................................................................................................. 21
Supervision system ................................................................................................... 22
Code List ....................................................................................................................... 22
Service/Maintenance ......................................................................................................................... 23
Service request .......................................................................................................... 23
Options ................................................................................................................................................... 24
Pressure sensitive safety edges placed on the door leaves ......................... 24
Infrared presence sensing system ....................................................................... 24
Laser presence sensing system ............................................................................. 25
Vertical presence photocell sensor PDR ........................................................... 25
Concealed sensor box ............................................................................................. 26
Emergency stop button (outside) ....................................................................... 26
Push button for disabled ........................................................................................ 26
ASSA ABLOY as word and logo are trademarks owned by the ASSA ABLOY Group
Environmental requirements
ASSA ABLOY Entrance Systems products are equipped with electronics and may also be equipped
with batteries containing materials which are hazardous to the environment. Disconnect power
before removing electronics and battery and make sure it is disposed of properly according to local
regulations (how and where) as was done with the packaging material.
Product liability
According to regulations, the following are the responsibility of the owner or caretaker of the
equipment
• that the equipment operates correctly, so that it gives sufficient protection in regard to safety
and health
• that the equipment is operated and regularly maintained, inspected and serviced by someone
with documented competence in the equipment and in applicable regulations
• that the provided “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
(PRA-0003) are kept available for maintenance and service records
• that inspection covers the emergency opening function (when applicable)
• that the closing force is appropriate for the door size on fire-approved door systems (when ap-
plicable).
Service
Inspections should be done regularly by a trained and qualified person. The frequency of these in-
spections should be according to national regulations (or according to industry standard if there
are no national regulations). This is especially important when the installation concerns a fire-ap-
proved door or a door with an emergency-opening function. To extend the life of your investment
and ensure safe and reliable operation of the door, we recommend a minimum of 2 visits per year
or more, depending on usage and operating conditions. Environmental aspects shall also be con-
sidered.
As your entrances are part of your business flow, there’s every reason to keep them working well.
ASSA ABLOY Entrance Systems offers you a maintenance and modernization expertise to rely on.
Our Maintenance Programs and Modernization Services for entrance automation is backed by a ex-
tensive expertise for all types of pedestrian- and industrial door and docking systems, independent
of brand. At your disposal is a team of dedicated expert technicians, proven through decades of
maintenance, service and satisfied customers.
Technical specification
Manufacturer: ASSA ABLOY Entrance Systems AB
Address: Lodjursgatan 10, SE-261 44 Landskrona, Sweden
Type: ASSA ABLOY RD300-3 and ASSA ABLOY RD300-4
Mains power supply: 230V, 50/60Hz, mains fuse max. 10AT or
100-120V, 50/60Hz, mains fuse max. 16AT
Power consumption: Standard drive unit 200W/resting 30W
Max. support 400W/resting 30W
Temperature range: -20 to +50°C
Degree of protection: IP20
Degree of protection, drive: IPX5
Degree of protection, control IP54
actuators:
Sound pressure:
How the ASSA ABLOY RD300-3 and ASSA ABLOY RD300-4 work
The door is designed so that operation is not affected or interrupted by winds or by users pushing
the doors. The unique CDC control system was developed by ASSA ABLOY Entrance Systems specific-
ally for use with its products, and the result is a fully integrated entrance solution with no compromise
in design or function. The system ensures lowest operating/maintenance cost, highest safety and
best availability.
Automatic revolving door with drive unit fixed in the floor. Glass is the main component of the door
with less profiles, which makes it look more attractive.
F2 FUNC
02 DATA
2 3
1
5 6
4
8 9
7
+
2
↑ 0
↓ # –
S C
F
11
9
3
6
8
10
No. Description
1 Activation units
2 Program Control Device (PCD) with ON/OFF switch
3 Emergency stop button (inside)
4 Push button for disabled (inside) (option)
5 Main control unit CDC 4
6 Push button for disabled (outside) (option)
7 Emergency stop button (outside) (option)
8 Pressure sensitive safety edges placed on the drum edges
9 Force sensitive door leaves
10 Pressure sensitive safety edges placed on the door leaves (option)
11 Infrared presence sensing system (option)
12 Vertical presence photocell sensor PDR (option)
EAA156
The door configuration must be set by ASSA ABLOY Entrance Systems Service technicians.
FUNC
FUNC
on
DATA
3
DATA Locked
11 22 3
6
44 55 6
9
77 88 9
↑↑ 00 ++
↓↓ ## ––
C
FF SS C
0 1
ON/OFF switch
on FUNC
DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
↓ # –
#Access code#
S C
F
0 1
ILL-01894
F2 FUNC
F2 FUNC
DATA
02 DATA
S
2 3 2 3
1 1
5 6 5 6
4 4
8 9 8 9
7 7
↑ 0 + ↑ 0 +
– –
F 2
↓ # ↓ #
S C S C
F F
0 1 0 1
ILL-01895
on FUNC
DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
↓ # –
#Access code#
S C
F
0 1
ILL-01894
ILL-00180
Automatic operation 02
The door is parked in standby position when there is no traffic. As soon as the outside or inside ac-
tivation units detect approaching traffic, the door starts rotating.
ILL-00189
Continuous rotation 06
The door rotates at a low speed. As soon as the outside or inside activation units detect approaching
traffic, the door accelerates to normal speed. The door returns to low speed when there is no traffic.
ILL-00190
+
-
9
10
18 0
11
12
1
2
2
4
3
F556 = 9
8
8
7
7
6
6
5
5
4
4
3
7 5
6
Deactivation 10
11
12
12
1
2
11 1
7
6
5
5
43
8 6 4
7 5
6
ON/OFF switch
The OFF (0) position overrides real time operation. The door will be locked. When
0 1
set to the ON (1) position, the door resumes operation according to schedule.
EAA204
time) is value 00 and summertime on is value 01) and press S (select). To check the
time change, see Real time clock. +/- DATA
EAA400
Week schedule
Week day Schedule
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Exceptions
Start exception End exception Exception schedule
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
10 10 10
11 11 11
12 12 12
13 13 13
14 14 14
15 15 15
16 16 16
↑/↓ FUNC
DATA
EAA254
3
2
E
D
Standard
No. Description
1 Pressure sensitive safety edges placed on the drum edges, see page 17.
2 Force sensitive door leaves, see page 17.
3 Emergency stop button (inside), see page 17.
Options
No. Description
A Pressure sensitive safety edges placed on the door leaves, see page 24.
B Infrared presence sensing system, see page 25.
C Vertical presence photocell sensor PDR, see page 25.
D Emergency stop button (outside), see page 26.
E Push button for disabled, see page 26.
F2 FUNC
02 DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
C
↓ # –
S C
F
0 1
F2 FUNC
02 DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
C
↓ # –
S C
F
0 1
pH5-9
= Contact your ASSA ABLOY Entrance Systems service representative. For contact information, see last page.
• Do not expose windows, doors or profiles to alkalis. Both aluminium and glass are sensitive
to alkalis.
• Do not clean with high-pressure water. Operator, programme selector and sensor may be
damaged and water may enter the profiles.
• Do not use detergents or abrasive additives.
• Do not scrub with materials like Scotch-brite, as this will cause mechanical damage.
LANDSKRONA SWEDEN
FACTORY NO. X
XXXXXX XXXX XXXXXXXXXXX
LODJURSGATAN 10
PROJECT/SERIAL NO. YEAR+WEEK TEMPERATURE
XXXXXXX
1 2 3 4 5 6 7 8 PROD. ORDER
CERTIFIERING
SÜD
KONTROLL
1004355
1002 xxxxxxx
Part of the Besam range xxxxxxx
No entry
B Keep clear
E
Keep clear
No entry
assaabloyentrance.com
Automatic
door
Automatic
F door
1100
1200
If problem
Action
occurs
Check that all required signage is applied and intact. Mandatory indicates that the signage is re-
quired by European directives and equivalent national legislation outside the European Union.
No entry, identifying one-way traffic: Mandatory in GB and US, if applicable, not included
B
in the product.
Supervision of child (applied to both sides of the door): Mandatory according to national
C
regulations. Recommended, if the risk analysis shows use by children.
D Keep clear
ASSA ABLOY Entrance Systems door sticker: Mandatory, if applicable to highlight the
E
presence of the glass (applied to all glass sections that are moving).
F Automatic door
= Contact your ASSA ABLOY Entrance Systems service representative. For contact information, see last page.
Code List
Code Status Cause Remedy
ON The revolving door is func-
tioning normally
10 Stop Safety edge activated Check for obstacles between the wing and
the floor and between the wing and the
inside of the drum. Check safety edges.
11 Electromechanical lock error No signal from the elec- Make one more unlock/lock operation. If
tromechanical lock that does not help call
ASSA ABLOY Entrance Systems Service.
20 Emergency stop Emergency stop button Release the button by turning it in the dir-
pressed down ection of the arrows, then restore function
by pressing C on the PCD.
21 Response from the PDR Inner PDR sensor activated Remove obstacle in the inner detection
sensor fitted above the zone
opening on the inside
22 Response from the PDR Outer PDR sensor activated Remove obstacle in the outer detection
sensor fitted above the zone.
opening on the outside
25 Response from the touchless The detection zone of the Remove obstacle in the detection zone.
door leaf sensors (the door touchless door leaf sensors
rotates slowly) activated
26 Response from the touchless The detection zone of the Remove obstacle in the detection zone.
door leaf sensors (the door touchless door leaf sensors
stops) activated
30 Blocked door The wing is blocked by an Check for obstacles between the wing and
obstacle the floor and between the wing and the
inside of the drum. After checking, press C
on the PCD.
32 Power fail input Mains power lost Check mains fuse.
Check external power supply.
For all other status codes, contact your ASSA ABLOY Entrance Systems service representative.
=
For contact information, see last page.
Service request
After 300.000 revolutions the prompt P2 indicates that it is time for service.
Minimum maintenance interval of once a year. See EN16005.
FUNC
P2
DATA
EAA253A
With NCD
Without NCD
F2 FUNC
02 DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
↓ # –
S C
F
Center plate
Center plate could be put on the finished floor.
With NCD
Without NCD
Electromechanical lock
The electromechanical lock, locks the door in home position.
DATA
2 3
1
5 6
4
8 9
7
↑ 0 +
↓ # –
#Access code#
S C
F
0 1
F2 FUNC
F2 FUNC
S
DATA
02 DATA
2 3 2 3
1 1
5 6 5 6
4 4
8 9 8 9
7 7
+ +
F 2
↑ 0 ↑ 0
↓ # – ↓ # –
S C S C
F F
0 1 0 1
F2 FUNC
F2 FUNC
F2 FUNC
01 DATA
02 DATA 06 DATA
2 3
2 3 2 3 1
1 1
5 6
5 6 5 6 4
4 4
8 9
8 9 8 9 7
7 7
↑ 0 +
↑ 0 + ↑ 0 +
↓ # –
↓ # – ↓ # –
S C
S C S C F
F F
0 1 0 1 0 1
F2 FUNC
on FUNC
07
DATA
E
DATA
FUNC
+
3 2 3
1 2 1
5 6 4 5 6 30 DATA
C
4 3
9 1 2
-
8 9 7 8
7 6
+ 4 5
↑ 0 + ↑ 0
8 9
– # – 7
↓ # ↓
↑ 0 +
C S C
F S F
↓ # –
S C
F
0 1
Locked
0 1
0 1
E
FUNC
20 DATA
C
2 3
1
5 6
4
8 9
7
↑ 0 +
↓ # –
S C
F
0 1
Certificate issued by a notified or competent body (for full address, please contact ASSA ABLOY Entrance Systems
AB) concerning the equipment:
BY/112 02.01 020 07600 B 058029 0042
The manufacturing process ensures the compliance of the equipment with the technical file. The manufacturing
process is regularly assessed by 3rd party.
DoC 1013749-en-6.0
assaabloyentrance.com