Professional Documents
Culture Documents
Project Data: Project Name Project Number Author Description Date 26-Dec-23 Design Code AISC 360-16
Project Data: Project Name Project Number Author Description Date 26-Dec-23 Design Code AISC 360-16
Project no:
Author:
Project data
Project name
Project number
Author
Description
Date 26-Dec-23
Design code AISC 360-16
Material
Steel S235, A36
Concrete 4000 psi
1 / 21
Project:
Project no:
Author:
Design
Name Base plate
Description
Analysis Stress, strain/ simplified loading
Design code AISC - LRFD 2016
Cross-sections
Name Material
2-
S235
T50x50x1.5(BoxFl50x(50/50))
6 - L50x5(L50) S235
2 / 21
Project:
Project no:
Author:
Anchors
Diameter fu Gross area
Name Bolt assembly
[mm] [MPa] [mm2]
1/2 A307 1/2 A307 13 414.0 127
Foundation block
Item Value Unit
CB 1
Dimensions 690 x 370 mm
Depth 200 mm
Anchor 1/2 A307
Anchoring length 100 mm
Shear force transfer Friction
Check
Summary
Name Value Check status
Analysis 100.0% OK
Plates 0.0 < 5.0% OK
Anchors 41.0 < 100% OK
Welds 41.9 < 100% OK
Concrete block 2.4 < 100% OK
Shear 58.6 < 100% OK
Buckling Not calculated
Plates
fy Thickness σEd εPl σcEd
Name Loads Check status
[MPa] [mm] [MPa] [%] [MPa]
COL-tfl 1 235.0 1.5 LE1 160.5 0.0 0.0 OK
COL-bfl 1 235.0 1.5 LE1 108.4 0.0 0.0 OK
COL-w 1 235.0 1.5 LE1 178.4 0.0 0.0 OK
COL-w 2 235.0 1.5 LE1 123.4 0.0 0.0 OK
M2-bfl 1 235.0 5.0 LE1 23.4 0.0 0.0 OK
M2-w 1 235.0 5.0 LE1 30.6 0.0 0.0 OK
M3-bfl 1 235.0 5.0 LE1 26.3 0.0 0.0 OK
M3-w 1 235.0 5.0 LE1 32.4 0.0 0.0 OK
BP1 235.0 8.0 LE1 130.2 0.0 0.0 OK
3 / 21
Project:
Project no:
Author:
Design data
fy εlim
Material
[MPa] [%]
S235 235.0 5.0
Symbol explanation
εPl Plastic strain
σcEd Contact stress
σEd Eq. stress
fy Yield strength
εlim Limit of plastic strain
4 / 21
Project:
Project no:
Author:
5 / 21
Project:
Project no:
Author:
Anchors
Nf V ϕNcbg ϕVcp Utt Uts Utts
Shape Item Loads Status
[kN] [kN] [kN] [kN] [%] [%] [%]
A5 LE1 7.2 0.0 42.6 83.2 41.0 0.0 22.6 OK
Design data
ϕNsa ϕVsa
Grade
[kN] [kN]
1/2 A307 - 1 26.5 14.8
Symbol explanation
Nf Tension force
V Resultant of shear forces Vy, Vz in bolt
ϕNcbg Concrete breakout strength in tension – ACI 318-14 – 17.4.2
ϕVcp Concrete pryout strength in shear – ACI 318-14 – 17.5.3
Utt Utilization in tension
Uts Utilization in shear
Utts Utilization in tension and shear
ϕNsa Steel strength of anchor in tension - ACI 318-14 – 17.4.1
ϕVsa Steel strength of anchor in shear - ACI 318-14 – 17.5.1
Where:
ϕ = 0.70 – resistance factor
Ase,N = 92 mm2
– tensile stress area
6 / 21
Project:
Project no:
Author:
AN c
ϕNcbg = ϕ ⋅
Where:
Nf g = 17.5 kN
– sum of tension forces of anchors with common concrete breakout cone area
AN c0 = 90000 mm2 – concrete breakout cone area for single anchor not influenced by edges
Ψed,N = 0.85
– modification factor for edge distance:
1.5⋅hef , 1) , where:
a,min
ca,max = 280 mm – maximum distance from the anchor to one of the three closest edges
Ψecx,N = 2⋅e1 x,N = 0.95 – modification factor that depends on eccentricity in x-direction
1+
3⋅hef
Ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
1+
3⋅hef
Ψc,N = 1.00
– modification factor for concrete conditions
Nb = kc ⋅ λa ⋅ fc′ ⋅ h1.5
ef , where:
7 / 21
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Ase,V = 92 mm2 – tensile stress area
Where:
ϕ = 0.65 – resistance factor
kcp = 2.00
– concrete pry-out factor
Ncp = 64.0 kN – concrete cone tension break-out resistance in case all anchors are in tension
Vg = 0.0 kN
– sum of shear forces of anchors on common base plate
Where:
Utt = 0.41 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
8 / 21
Project:
Project no:
Author:
AN c
ϕNcbg = ϕ ⋅
Where:
Nf g = 17.5 kN
– sum of tension forces of anchors with common concrete breakout cone area
ϕ = 0.70 – resistance factor
AN c0 = 90000 mm2 – concrete breakout cone area for single anchor not influenced by edges
Ψed,N = 0.85
– modification factor for edge distance:
1.5⋅hef , 1) , where:
a,min
ca,max = 280 mm – maximum distance from the anchor to one of the three closest edges
Ψecx,N = 2⋅e1 x,N = 0.95 – modification factor that depends on eccentricity in x-direction
1+
3⋅hef
Ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
1+
3⋅hef
Ψc,N = 1.00
– modification factor for concrete conditions
Nb = kc ⋅ λa ⋅ fc′ ⋅ h1.5
ef , where:
9 / 21
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Ase,V = 92 mm2 – tensile stress area
Where:
ϕ = 0.65 – resistance factor
kcp = 2.00
– concrete pry-out factor
Ncp = 64.0 kN – concrete cone tension break-out resistance in case all anchors are in tension
Vg = 0.0 kN
– sum of shear forces of anchors on common base plate
Where:
Utt = 0.41 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
Ase,N = 92 mm2 – tensile stress area
10 / 21
Project:
Project no:
Author:
AN c
ϕNcbg = ϕ ⋅
Where:
Nf g = 17.5 kN
– sum of tension forces of anchors with common concrete breakout cone area
ϕ = 0.70 – resistance factor
AN c0 = 90000 mm2 – concrete breakout cone area for single anchor not influenced by edges
Ψed,N = 0.85
– modification factor for edge distance:
1.5⋅hef , 1) , where:
a,min
ca,max = 280 mm – maximum distance from the anchor to one of the three closest edges
Ψecx,N = 2⋅e1 x,N = 0.95 – modification factor that depends on eccentricity in x-direction
1+
3⋅hef
Ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
1+
3⋅hef
Ψc,N = 1.00
– modification factor for concrete conditions
Nb = kc ⋅ λa ⋅ fc′ ⋅ h1.5
ef , where:
11 / 21
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Where:
ϕ = 0.65 – resistance factor
kcp = 2.00
– concrete pry-out factor
Ncp = 64.0 kN – concrete cone tension break-out resistance in case all anchors are in tension
Vg = 0.0 kN
– sum of shear forces of anchors on common base plate
Where:
Utt = 0.41 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
12 / 21
Project:
Project no:
Author:
AN c
ϕNcbg = ϕ ⋅
Where:
Nf g = 17.5 kN
– sum of tension forces of anchors with common concrete breakout cone area
AN c0 = 90000 mm2 – concrete breakout cone area for single anchor not influenced by edges
Ψed,N = 0.85
– modification factor for edge distance:
1.5⋅hef , 1) , where:
a,min
ca,max = 280 mm – maximum distance from the anchor to one of the three closest edges
Ψecx,N = 2⋅e1 x,N = 0.95 – modification factor that depends on eccentricity in x-direction
1+
3⋅hef
Ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
1+
3⋅hef
Ψc,N = 1.00
– modification factor for concrete conditions
Nb = kc ⋅ λa ⋅ fc′ ⋅ h1.5
ef , where:
13 / 21
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Where:
ϕ = 0.65 – resistance factor
kcp = 2.00
– concrete pry-out factor
Ncp = 64.0 kN – concrete cone tension break-out resistance in case all anchors are in tension
Vg = 0.0 kN
– sum of shear forces of anchors on common base plate
Where:
Utt = 0.41 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
14 / 21
Project:
Project no:
Author:
Weld sections
Th Ls L Lc Fn ϕRn Ut
Item Edge Xu Loads Status
[mm] [mm] [mm] [mm] [kN] [kN] [%]
BP1 COL-tfl 1 E70xx ◢2.8 ◢4.0 50 10 LE1 2.3 8.4 27.1 OK
BP1 COL-bfl 1 E70xx ◢2.8 ◢4.0 50 10 LE1 1.3 9.1 14.1 OK
BP1 COL-w 1 E70xx ◢2.8 ◢4.0 47 9 LE1 3.6 8.5 41.9 OK
BP1 COL-w 2 E70xx ◢2.8 ◢4.0 47 9 LE1 2.5 8.5 29.8 OK
COL-w 1 M3-bfl 1 E70xx ◢2.8◣ ◢4.0◣ 48 10 LE1 0.3 6.0 5.0 OK
E70xx ◢2.8◣ ◢4.0◣ 48 10 LE1 0.3 6.2 4.3 OK
COL-w 1 M3-w 1 E70xx ◢2.8◣ ◢4.0◣ 45 9 LE1 0.9 8.3 11.4 OK
E70xx ◢2.8◣ ◢4.0◣ 45 9 LE1 0.8 8.3 10.0 OK
COL-w 2 M2-bfl 1 E70xx ◢2.8◣ ◢4.0◣ 48 10 LE1 0.2 8.3 1.8 OK
E70xx ◢2.8◣ ◢4.0◣ 48 10 LE1 0.2 7.8 2.4 OK
COL-w 2 M2-w 1 E70xx ◢2.8◣ ◢4.0◣ 45 9 LE1 0.9 8.2 10.6 OK
E70xx ◢2.8◣ ◢4.0◣ 45 9 LE1 0.9 8.2 10.7 OK
Symbol explanation
Th Throat thickness of weld
Ls Leg size of weld
L Length of weld
Lc Length of weld critical element
Fn Force in weld critical element
ϕRn Weld resistance AISC 360-16 J2.4
Ut Utilization
Where:
Fnw = 400.2 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
15 / 21
Project:
Project no:
Author:
Where:
Fnw = 433.6 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 427.7 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 428.8 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
16 / 21
Project:
Project no:
Author:
Where:
Fnw = 293.0 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 304.9 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 433.0 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
17 / 21
Project:
Project no:
Author:
Where:
Fnw = 434.2 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 410.0 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 387.1 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
18 / 21
Project:
Project no:
Author:
Where:
Fnw = 430.7 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Where:
Fnw = 430.1 MPa – nominal stress of weld material:
FEXX = 482.6 MPa – electrode classification number, i.e. minimum specified tensile strength
Concrete block
A1 A2 σ Ut
Item Loads Status
[mm2] [mm2] [MPa] [%]
CB 1 LE1 10558 49843 0.7 2.4 OK
Symbol explanation
A1 Loaded area
A2 Supporting area
σ Average stress in concrete
Ut Utilization
19 / 21
Project:
Project no:
Author:
ϕc fp,max =
30.5 MPa ≥ σ= 0.7 MPa
Where:
fp,max = 46.9 MPa – concrete block design bearing strength:
≤ 1.7 ⋅ fc′ , where:
fc′
= 27.6 MPa – concrete compressive strength
Symbol explanation
V Shear force
ϕVr Shear resistance
μ Coefficient of friction between base plate and concrete block
Ut Utilization
ϕc Vr = ϕc ⋅ μ ⋅ C =
2.0 kN ≥ V = 1.2 kN
Where:
ϕc = 0.65
– resistance factor for concrete
Buckling
Buckling analysis was not calculated.
Code settings
Item Value Unit Reference
Friction coefficient - concrete 0.40 - ACI 349 – B.6.1.4
Friction coefficient in slip-resistance 0.30 - AISC 360-16 J3.8
Limit plastic strain 0.05 -
Plastic
Weld stress evaluation
redistribution
Detailing No
20 / 21
Project:
Project no:
Author: