Product: GEN SET ENGINE


Model: 3616 GEN SET ENGINE 1PD00737
Configuration: 3616 Generator, Industrial and Locomotive 1PD00001-UP

Engine News
1995/12/20
Media Number -SEBD9230-00 Publication Date -20/12/1995 Date Updated -20/12/1995

SEBD92300008

Revised Starting Procedure For Engines Operating On Heavy


Fuel Oil (HFO) {1100}
SMCS - 1100

3606 (8RB),
3608 (6MC),
3612 (9RC),
3616 (1PD) Engines Operating On Heavy Fuel Oil

SUPPLEMENT: 08/01/97

Engine News; December 1995; Page 5; "Revised Starting Procedure For Engines
Operating On Heavy Fuel Oil (HFO)"

Disregard this article. See the article titled "Revised Starting Procedure For Engines Using
Kiene® Valves" in Engine News SEBD9251, Article 16, Page 21.

--------------- END SUPPLEMENT ---------------

Reference: Engine News, December 1990, Page 9, "Installation Of Kiene® Valves"

In order to use the following "Revised Starting Procedure For HFO Engines", the engine must be
equipped with 7E-2492 Valve Groups (Kiene Valves). The Reference Article and the Reference
provide information about the installation of Kiene Valves.

Revised Starting Procedure For Engines Operating On Heavy


Fuel Oil (HFO)
Use this procedure to prevent a possible "hydraulic lock" of engine cylinders.

1. Prior to starting the engine, open all Kiene Valves.

https://127.0.0.1:446/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 10/6/2023
3616 Generator, Industrial and Locomotive 1PD00001-UP(SEBP3783 - 110)/Basic Search Page 2 of 2

2. Place the fuel ON/OFF switch in the "OFF" position.

3. Turn the engine control switch from the "OFF/RESET" position to the "RUN" position. This will
start the prelube pump.

4. Once sufficient prelube pressure is indicated, momentarily turn the engine control switch to the
"START" position. This is done to roll the engine over.

5. Inspect all of the Kiene Valve outlets. If indications of fluids are present, record the cylinder
number and report the findings to the maintenance supervisor prior to further engine operation. If
there are no indications of fluids present, close and cap all Kiene Valves.

6. Proceed with the normal starting procedure.

Copyright 1993 - 2023 Caterpillar Inc. Fri Oct 6 17:05:07 UTC+0300 2023