Download as pdf
Download as pdf
You are on page 1of 8
Ob} BUSHINGS AND ACCESSORIES wares-trafo.com FOR DISTRIBUTION AND POWER TRANSFORMERS Company Profile ARES TRAFO has been manufacturing many accessories Used for power and distribution transformers almost 20 years and so farits one ofthe most well nown companies in this market for energy sector. ARES TRAFO is exporting more than 74% of its products to ‘worldwide, This success has been built up through long- term relationships with customers and ARES TRAFO becoming a reliable manufacturer of consistently high quality products. Production and logistics are focused on the continuous improvement of efficiency. ARES TRAFO is able to customize almost every product in order to satisty customer requirements and sharing expertise and experiences to improve customer service, Today, ARES TRAFO has operation faciilies in two locations in Turkey - Kartepe, employs more than 120 people, serving for transformer accessories production and transformer coil windings for transformer manutacturers, (Our sales department and engineering department always able to give a positive answer to the demands of the customers, mote and more frequently dealing with the various requirements; the efficiency of this service is shown by delivery terms on line with customer needs, good packing, clear documentation, ‘Ares Accessories Production Facility : 6000 m? Ares Coil Winding Facility :$000 m= jes ES ARES TRAFO ARES TRAFO [ PORCELAIN BUSHINGS FOR DISTRIBUTION TRANSFORMERS mh Porcelain bushings for Distribution Transformers with arated voltage range from 1 KVte 3kVand arated current range of 250A to 6300A, “These bushings are manufactured in accordance with EN 50386 , DIN 42530 and DIN42539 norms. Primarily used for indoor and outdoor applications in the field of distoution transformers, these bushings are avaliable in several designs and can be customized to fit almost any kind of customer requirement upon request. tinplating, special drilings, special connectors, etc) ‘The LV series features a porcelain and plastic insulating body on the oll side; in adlion, rods are available both in copper or brass. We can provide excellent performance even under very extreme applications for-60C orsilicone ols, [ PORCELAIN BUSHINGS FOR POWER TRANSFORMERS Porcelain bushings for power transformers with arated voltage range from 12Vto $2 kV and arated current range of 250A 03150A These busrings are manufactured in accordance with EN 50180, DIN 42531 , DIN 42532 , DIN42533 norms. Featuring an extensive range of avalable customizations, the HV bushing can be manufactured according to almost anykindof customer requirement (0. od extension, special connectors, special nish surface Designed for both indoor and outdoor applications, the HV bushing series can even operate under extreme environmental conditions (.e. very polluted areas, very cola/hot ambient temperatures, very corrosive/aggressive environments, ete). [ PLUG-IN BUSHINGS FOR DISTRIBUTION TRANSFORMERS Plug-in bushings fo olimmersed distribution transformers manufactured from epoxy resin are used atthe HV Side ofthe Indoor and with special material for outdoor transformers . Plug in Bushings in compliance with EN 50780 and EN 50181 / IECBO137 Interfaces of A-B-C-D-E-F types Plug in Bushings up to 12-24-36 kV, and 2508-63041 250A levels. Insulation materials Epoxy Resin rom Huntsman which has 90°C to 118°C Tg We deliver with accessories of Plastic Cover for protection , Aluminium Clamp, Fixing Ring, Earthing Cablo, Gasket, Brass Nuts & Washers [bushing Flag Connectors We produce ace to DIN 43675 and wehave bushing lag connectors ae avaiable in several G designs and can be custarrized to fit almost any kind of customer requirement upon request [ sucHHOLz RELAYS FOR TRANSFORMER PROTECTION ((2.tinorsiverplating, special drilings, special connection threads, etc.) ARES Buchholz Relay in accordance with EN 50216-2 protects liquid immersed transformers and reactors with conservator. It will be mounted in the pipe'ine between transformer and conservator tank, ‘ARES Buchholz Relay operates as a protection device that can be provided with two or throe contacts for alarm ana tipping, ‘The relay operates via an alarm switch nthe event of gas accumulation or viaa trp switch inthe event ofan abrupt increase inthe al owrate or loss fal [ Magnetic oi! Level Gauges With Contacts ARES Magnetic Oil level gauges ace. to DIN42569 for liquid immersed transformers for conservator tanks It ‘operates as a protection davies that can be provideo with two contacts for alarm and ripping [ Magnetic oi! Level Gauges ARES Magnetic Oil level gauges acc. to DIN42569 for iquid immersed transformers for Conservator tanks. It operates as @ protection device that can be provided with two contac's| for alarm and tipping with itis moving float, [vertical oi! Level Gauges [ARES Vertical O1 level gauges operates with vertical float movement is used for hermeticaly sealed transtormors. Tho float movement's ransmittedto the dsplay by means o!amagnotic clutch, [ Axiat Cooling Fans for Power Transformers = [ARES Axial cooling fans are a type of device that increases airflow pressure as it passes through. The fan blades work by forcing air to move parallel othe shaft, which the blades rotate around, The axial fan characteristics such as airflow, power, volage, ‘equency, noise level, mansions, corrosion class, protection class and materials of components can be adjusted. Ace. to ErP2015 andwe design yourfans according to "your requirements with minimum power consumption Sizes :trom 946010 01250 mm ‘Airvolume (free blowing} from 3750-60000 m3/h (S0hz- design) &60Hz-design Protection IPSS P66 levels, ACCORDING TO ErP DIRECTIVE 2016/125/EG [ cross Fiow fans tor Dry Type Transformers ARES Cross Flow fans for Dry Type Transformers have optimal solutions for air forced cooling ol transformers. High performance induction motor cross fow fans are designed to dissipate heat generated by dry type transformer losses while complying with the markel requirements and assure faitsafe operations in all industria zones. [simetal Thermometers ARES Bimetal thermometers in accordance with DIN 16160 is used for indicating and monitoring the ol temperature of distrbution transformers. The thermometer willbe mounted fn the transformer cover and is avalab with toe affront connection threads: GI” G2", ue The Bimetal Thermometer operates with either one limit switch (alarm) or two switches (alarm ‘and tipping) for monitoring settable mit values. ‘Also we have models without contact thermometers. les ARES TRAFQ.§ iy grectrats com [ressure Rett Deve wh contacts ARES pressure safety devices are designed to pravent excessive mechanical stress caused by increases in pressure thal can occur in the event of a shor circuit inside an oilfiledtranstormer 50 and T80 prossuro safety devices are designed to operate quickly in response to sudden increases in pressure insids the transformer. Ifthe pressurein the transformer rises above a pre-set pressure between 30 - 70 kPa, the valve opens and the overpressure releases, Alter decline, the cover of the device closes again leaktight, It 'sequipped upon request with one ortwoNO or NC contacts. J eressureRetetVave ARES pressure safely devices are designed to operate quickly in response to sudden increases In pressure inside the Transformer, If the pressure in the transformer rises above a pre-set pressure between 30 - 70 kPa, the valve opens and the overpressure releases in addition to the operatinglimits of EN50216-1 ,1"-1 6" 2'sizos [ Flanged and Screwed Ball Valves ARES ball valves sa shutoff valve that controlstheflowofaoillquid_ by means ofarotary ball having a bore. By rotating the ball a quarter turn (80 degrees) around ts axis, tne medium can flowthrough or is blocked. ‘These ball valves are designed te prevent ol leakage with special sealing system for olfiled transformers with $8304 or S8316 body materas. [ransomer cate vanes ARES Gate valve functions by liting a circular gate out of the path ofthe ol When the valve is fully open, gate valves are ful bore, meaning there ‘s nothing to obstruct the flow because the gate and pipoline diameter have the same opening ‘These gate valves are designed to prevent oil leakage for oi-filed transformers with Brass, Bronze or Stainless Steel materials with sizes of DN25-50-80-100mm and some of gate valves with drain and single flanges. [rass and Bronze Drain Valves: ARES drain valve functions by lting a circular globe part out ofthe path ofthe oil When the valve is fully open there is nothing to obstruct the fiow because of that easily drain the “Transformer oil These drain valves are designed to prevent ol leakage for oiled transformers with Brass or ‘Bronze Materials with sizes of ON1S-25-32mm and some of gate valves with drain and single flanges. as [ Stainless Drain Valves [ARES stants drain vave functions by iting acitcular globe part out ofthe path ofthe oil When the vave's fully open theres nothing to obstruct the fowbecause ofthat easly sranthe fansforme i ‘These dain valves are designed to prevent oil leakage for ci-filed transformers wth transformers with $5304 or $5316 stianess stee| materials. wit sizes of DN15-22mm P andsomeof gate valves with drainand single anges. y les ARES TRAFQ.§ iy grectrats com [Buttery valves tor Radiators ‘valiabloin sizes of DN100-125-150-200-250-300mm ‘Theroundvalves are available in range from DN 00mm to ON3GOMm nominal diameter The radiator valves are avaiable with metal to metal sealing, and seaing wth O-ing (zero leakage). Furhnermore all buterly valves are avaliable in an offshore version, With an AISI 318 body, they work perfecty even in very extreme [ ster vate for Ratators ono [ARES utterly valves for radiator valves have a nominalbore diameter of DN&O mm land. avaiable nwth metaltametal sealing, and sealingwth O-ring (eroleakage) Furthermore, al buttery vaves are avaiable in aluminium, sel and SS316 body Ourvaves are designedin accordance with EN 50216-8 (DIN 42560) [ Buttertly valves for Buchholz Relays ARES Buttery valves for Buchholz Relays are the perlect devices for enabling isolation of he Buchholz relay for replacement purposes as well as lor enabling the disconnection of buchholzrelay on pipeline. These butterfly vaives have sealing with O-ring (zero leakage , Furthermore, all buttery valves are available in aluminium, steel and S$316 body. Avalable in Sizas of DN25-50-80mm. Our valves are designed in accordance with EN 502166 (DIN 42560). ‘Se [terminal Connection Boxes ARES terminal boxes help to wiring connections with terminals, insulation teed ‘throughs of cast aluminum ane IP8S protectin. Terminal boxos are available in a wide variety torminals/eniries for use in several applcalions with different cable glands [Copper Flexible Braided Connectors ‘ARES. connectors are manufactured from highly flexible wires, which are braided trom annealed Cu- ETP wires, and solderiess contact areas pressed trom seamless Cu-ETP lubes , we also manufacture those parts trom tinned wires andtin coated contact areas. iy [Copper Flexible Press Welded Foil Connectors ARES connectors are constructed from Cu:HCP foils with a thickness of 0,10 to 0,30 mm by ‘overlapping the needed amount together and welding their nds as required contact aroas without a Using ary welding additive, This special welding process takes places under high pressure and intensive heat. These connectors have a uniform cross-section over thoir enti longht and de to theirhomogeneus molecular structure; they are perfect electrical conductors. [ Moisture Holders ARES moisture holders used to dry the intake air of transformers i the operating temperature ofthe transformer drops, air will be sucked in and ied by the silica ge! inside Ifthe temperature rises, ai is expelled fromthe ‘conservator and flows through the transformer dehydrating breather in the opposite direction. The size of the dehydrating breather which nas tobe used depends onthe ol volume. les ARES TRAFQ.§ iy grectrats com [Distribution Transformer Wheels Designaccording to DIN 42561 and customer specication Diameter: 125 0 @200mm [ Power Transformer Wheels Design accordingte DIN256! and customer specications up to 7Otonnes, Diameter: 0100t00400mmwthand without ra Single whoo! ordouble whee! with conebearngs ‘Special request as regards the fking at the transformer tank are always taken inte account, special diameters flat wheel design, blocking device vi [ 62s Sampling Device for Buchhotz Relay ‘The gas samoling device as follows has been designed to overcome this problem by sting the unit remote {rom the Buchnolzand in areadiy access bie postion typically onthe side othe transformer, ‘The presence of gas inside an ol fled transformer is always a sign of malfunction and to analysis of the evolved gas can often give good indication of the type of malfunction but accessing the Buchholz relay [ Nitrogen Pressure Regulator Usedias Air pressure Regulator for vansportation oftransformers withoutollwith Ory Alror Nirogen. ~ 7 [coil wining tor Distribution Transformers Production of 180-240 pieces (60-80 transformer) cols por Week up to 50 KVA-2 MV Production of 60 cols (20 transformers) per week at powers, o ‘between 2-5 MVA, es 4 [ coil winding for Power Transformers. Production of 60 coils (20 transformers) per month for powers between 5-30 MVA, Production of 60 pieces (20 transformers) colls per month at powers between 30-S0MVA, MANUFACTURING FACILITIES ARES TRAFO has several CNC machines which provides us to manufacture thousands of high quality products with the latest lechnolagy. We have inhouse machinery capacity ARES TRAFO aims the improving reliabilty day by day and designing new procucts to satisty the latest market requirements , we do changes ang improvements by customer advises, QUALITY AND MANAGEMENT SYSTEM CERTIFICATION ARES TRAFO quality management system has been ISO 001-2015, IS045000:2018 and I$014000:2015 certified. ARES TRAFO bushings and accessores are designed and manufactured to salisly and exceed the requirements of intemational IEC and EN standards andregulations, Each product is routine tested and controlladinaividually ‘All products are testedin acoordancewith the latest EN 50216 (accessores for power transformers) standards with routine and type tests aay | me Kartepe - Kocaeli TR-41250 TURKIVE Phone: ~90 262 371 13 22 email: info@ares-trafo.com ARES TRAFO — wwares-trafo.com AR J RES RAFO EKipmanian San, vo Ti. Ls. St ES San Mege Mah, Nazm Demirci Cad, No: 264

You might also like