Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

I N FA N T R A D I A N T WA R M E R

Tende VAV-IW, Infant Warmer is a comprehensive infant care system


that also supports the clinicians with its advanced algorithm and
utmost automation feature to begin to act instantly when necessary.

to warm up
Color TFT Touch Screen Display T me Rema n ng for Warm Up

Tende VAV-IW, Infant Radiant Warmer, provides users with accurate, effective and fast
operation and easy monitoring of patient data with 12.1 inch color TFT touch screen with
graphics, animations and detailed explanations.
7:45
M nutes Seconds

Power %30

Check Baby Alarm D sabled

With the 12.1 inch screen, users can easily observe intense data such as the Masimo Rainbow
SET pulse oximeter (SpO2) and non-invasive blood pressure measurement (NIBP). With the Easy
Mute feature, the clinician's alarms that occur during the procedure are silenced with just a Qu ck Start

hand gesture without touch. A New Pat ent

The Last Pat ent


Lighting
BABY SURNAME 24/08/2021 2800g Gestat on Age: 36w 7d

Clinicians have the opportunity to observe the baby by


set using examination lighting and / or spot lighting
36.8 34.0 according to their needs.

31.2
Electronic Mattress Tilt (Trendelenburg)
Power %30 The user can easily adjust the inclination of the bed
electronically without manpower on the color touch Baby Surname 24/08/2021 2800g Gestat on Age: 36w 7d

Systolic
screen. This process, which is done silently and 118 81 92 17:20 11/09/2018
118 81 92 17:20 11/09/2018
ALARM / INFORMATION BAR ... without vibration, does not disturb the baby. The fact 118 81 92 17:20 11/09/2018
ALARM / INFORMATION BAR

that the bed can be brought to the horizontal 93 120


110
0 200
Current Pressure: 1

115 81
120 100 Initial Pressure: 90
110 90 Mode: Manual

Normal
position with a single button enables the clinician to mmHg mmHg Interval (min): Manual

%SpO2 PI SpMet
NIBP
100 0.04 20 reach the baby without wasting time.
100 PR bpm
95
1:30
20.00 PVI
50
1:30
99.5
SpHb mmol/L
12
1:30

37.8
set
34.0
Power %30

117 120 20
249 100 20.0
10 m n.
1:30 1:30 1:30
100 87 12 37.7
ok 24.0
24/03/2021 10:08:47
+3º
- +

01:17:53 -⁶º 0 +⁶º

ALARM / INFORMATION BAR ...

Membrane Control Power Normal

88 88 The clinician can easily give commands 100


%SpO2
100
95
1:30
20.00
PI
0.04
50
1:30
99.5
SpMet
20
12
1:30

PR bpm PVI SpHb mmol/L

and monitor data with membrane keys 117 120 20

36.8
88.8 249 100 20.0
1:30 1:30 1:30
100 87 12
on the control panel suitable for usage 24/03/2021 10:08:47

habits.

888
36.0 888 88887
36.8 285 3600 Rotatable Bed
The 3600 rotatable mattress and the heater unit that can be
rotated in both directions allow surgical operations and
x-rays imaging to be performed easily.

Large Drawer
Tende VAV-IW has a large drawer that can be accessed
from the right and left sides of the infant warmer.
_
2800g

CONFIGURABLE STRUCTURE
BABY SURNAME 24/08/2021 Gestat on Age: 36w 7d

38.5

Tende VAV-IW, Infant Warmer can be congurable from the basic model to
38.0

37.5
36.4 36.6
37.0
36.2 36.0
36.5

36.0
36.0
06.04.2021
35.8
16:25 advanced features like resuscitator, air/oxygen blender, suction module, height
35.5

35.0

34.5
adjustment, phototherapy, pulse oximeter, NIBP, digital scale.
34.0

NIBP

set Power %30


37.8 34.0
10 m n.

37.7
ok 24.0
+3º
Resuscitator (Optional)
- +
The newborn can have consistent PIP and PEEP
01:17:53 -⁶º 0 +⁶º values for efcient oxygenation. There are two
ALARM / INFORMATION BAR ...
more option Air/Oxygen Blender and Suction
Module
Normal
%SpO2 PI SpMet
100 0.04 20
100 PR bpm
95
1:30
20.00 PVI
50
1:30
99.5
SpHb mmol/L
12
1:30

117 120 20
249 100
1:30
100 87
1:30
20.0 12
1:30

24/03/2021 10:08:47

Integrated Wireless Digital Scale (Optional)


Tende VAV-IW high sensitive weighing scale was designed
considering the safety and comfort of the infant. Just lifting
the newborn for a few seconds is enough to tare, then the
system performs weighing operations when the infant
lowered. Operation stages can be guided by animation from
the screen with sound.

NIBP (Optional)
NIBP (Non-Invasive Blood Pressure Measurement); Blood pressure and pulse
values for a infant can be measured with determined time intervals.
Clinicians can determine set values and activate audible and visual alarms.

Pulse-Oximeter (Optional)
Tende VAV-IW uses the most advanced Masimo Rainbow SET SpO2
technology. The advantage of this set is that it is also possible to measure
perfusion index (PI) and pleth variability index (PVI), total hemoglobin
(SpHb) methemoglobin (SpMet) values without taking blood samples from
the newborn (Non-Invasive).

Electronic Height Adjustment (Optional)


Clinicians can adjust the height of the infant warmer for a comfortable
working height. Lifting and lowering operations can be made silently
without vibration and without disturbing the newborn by means of the
motor which is specially produced for Tende VAV-IW. This operation can
be implemented by foot pedals from both sides of the infant warmer.
__
TECHNICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Display 12.1 inch Color TFT Touch Screen Display
Sizes Height (Standard): 182 cm, Width: 63 cm, Depth: 115 cm
Electronic Height Adjustment Ma ress Height; Min. 90 cm (± 1cm) Max. 110 cm (± 1cm)
Weight Standard;120 Kg, (Without op ons)
Wheels 4 Dual Wheeled Casters with All Fric on Brake (Diameter: 125 mm)
Monitoriza on Backup Monitoriza on A er Power Failure (Min. 20 Minutes)
Alarm Sound Level Adjustment Yes
Power Requirement 220-240V ± 10%, 50/60 Hz
OPERATING CONDITIONS
Temperature 15⁰C to 40⁰C
Humidity 0% to 90% (Noncondensing Rela ve Humidity)
MODES
Prewarm Mode Adjustable & No Alarms
Baby Mode Automated
Manuel Mode User Controlled
BASSINET SPECIFICATIONS
Ma ress Biocompa ble, Cytotoxicity and Skin Irrita on Free, Fire Retarded,
Water Proof & Washable (ISO 10993-10 Sensi vity Reported, ISO 10993-5)
Ma ress Size Length; 72 cm x Width; 55 cm x Height; 3 cm
Ma ress Tilt (Electronic Control) + 15 to -12 Degrees , Con nuously Variable
Rotatable Bed 360⁰ C
Grommets 4 Pcs
Drawer Large drawer (Two way opening)
Tube Holder Yes (Op onal)
IV Pole & Monitor Table Yes
HEATER & TEMPERATURE
Auto Heater Yes
Temperature Gauge 15⁰C - 42⁰C
Skin Temperature Control 34⁰C to 38⁰C with 0.1⁰C Resolu on )(>37oC with confirm)
Seramic Heater Life Time > 20,000 Hours
OTHER FEATURES
Timer Patented; Timer & Countdown (Timer also APGAR, CPR, PPV, Epinefrin Timer)
Examina on Lamp (LED) Yes, Op onal
Spot Examina on Lamp (LED) Yes
APGAR Timer Yes
Heater Head Rota on Yes 1800
LED PHOTOTHERAPY (OPTIONAL)
Light Source Blue LED (20 pcs, Super Bright LED)
Wavelength 460nm (± 2%)
LED Life Time > 70,000 Hours (Check the user manual for technical details)
Light Intensity (Standard) Adjustable
RESUSCITATION MODULE (OPTIONAL)
Peak Inspira on Pressure (PIP) Yes
Posi ve-end Expiratory Pressure(PEEP) Yes
Flow Capacity Yes
Airway Pressure Manometer Yes
AIR/O₂ BLENDER Yes, Op onal
Range 21-100 %O₂
Accuracy ± 3% full scale
Flowmeter Range 0-15 lpm
SUCTION Yes, Op onal
Waste Jar Capacity 1 liter
INTEGRATED DIGITAL SCALE (OPTIONAL)
Weight Range 100 gr to 10 kg (10,000 gr)
Weight Accuracy ± 5gr
Weight Display Resolu on 1 gr
SpO₂ & PULSE OPTION (Masimo Rainbow SET)
SpO₂ Display Range 0-100% SpO₂ with 1% Resolu on
Pulse Rate Display Range 0 to 240 BPM with 1 BPM Resolu on
PI, Arterial Pulse Signal Strength Perfusion Index 0 to 20 Values
PVI, Pleth Variability Index 0 to 100 Values
SpMet, Methemoglobin Satura on 0% to 100%
SpHb, Total Hemoglobin Concentra on in Arterial Blood 0% to 25% g/dL, 0% to 16% mmol/L
ORi, Oxygen Reserve Index 0.00 to 1.00 Values
NIBP OPTION (Method of Measurement; Oscillometric)
Blood Pressure Range Systolic 35-135 mmHg, MAP 20-115 mmHg, Diastolic 15-105mmHg
Cuff Pressure Measurement Range; 0-300 mmHg, Accuracy; ± 3 mmHg (0-50 ᵒC)
Cuff Deflate Rate Defla on Step Size Varies with Heart Rate, Cuff Pressure and Cuff Volume
Ini al Infla on Pressure 90 mmHg (Default), Variable from 60 to 140 mmHg
Self-Adjus ng Infla on Pressure Previous Systolic + 20 mmHg
Clinical Accuracy (Meets accuracy requirements of...) AAMI SP10, IEC 60601-2-30, IEC 80601-2-30, EN 1060-3, EN 1060-4 and ANSI/AAMI/ISO 81060-2.
Startup Ini aliza on Period 6 Seconds
Long Term Interval Periods 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240 Minutes
TREND PARAMETERS
2, 8, 24, 168 hours (7 Days) Trend Parameters for… Skin Temperature , Weight, SpO₂, NIBP
ALARMS (Audible & Visual)
Baby Check Alarm (In manuel mode) Yes
Skin (In Baby Mode) High/Low Temp., Over Temp., Skin Prob Read Fault, Skin Prob Disconnected
SpO₂, Pulse Rate High/Low Values, Related Security Alarms
Others Heater Temp. Fault, Power, Low Ba ery, Excess Weight, System Failure etc.

TENDE ELEKTRONİK YAZILIM MÜH. İLETİŞİM MAK. SAN. VE TİC. LTD. ŞTİ.

HEADQUARTER: Ahi Evran OSB Mahallesi, Akhun Caddesi No: 5/1, 06935 Sincan ANKARA TÜRKİYE
T: +90 312 397 0733 F: +90 312 397 1787 www.tende.com.tr info@tende.com.tr
The pictures in the brochure are only references and provide general information for the products. Tende VAV-IW R1 231108-EN

You might also like