12.2. As the cooling water flow-rate will be around half that of the caustic
solution, it will be best to put the cooling water through the tubes and the
solution through the annular jacket. The jacket heat transfer coefficient can be
velocity, u = 6000 x 1 x 1 = 0.98 m/s 3600 866 1.963 x 10-3 Re = 866 x 0.98 x
(50x10-3) = 96,441 0.44 x 10-3 Pr = 4.3 x 10-3 x 0.44x10-3 = 4.86 0.3895 Liquid
is not viscous and flow is turbulent, so use eqn 12.11, with C = 0.023 and
= (0.385/50x10-3)x 376 = 2895 Wm-2 °C-1 Take the steam coefficient as 8000
Uo = 1627 Wm-2 °C-1 ∆Tlm = (85 – 35)/Ln (85/35) = 56.4 °C (12.14) Ao = (411 x
increase the coefficient and reduce the area required. Leave estimate at 8