Base

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

COLUMN

BASES
ANNALYSIS &
DESIGN
REINFORCED CONCRETE
Project Proposed Residential House - Kiambu COUNCIL
Client Mr. Dove Livondo Made by Date Page
Location ADOPT FOR ALL THE BASES Single column Eng. S.A 113
PAD FOUNDATION DESIGN to BS 8110:1997 base Checked Revision Job No
Originated from RCC81.xls v on CD © 1999-2003 BCA for RCC Eng. D.o

MATERIALS fcu 35 N/mm² h agg 20 mm gc 1.5 concrete


fy 460 N/mm² cover 50 mm gs 1.05 steel
Densities - Concrete 24 kN/m³ Soil 18 kN/m³
Bearing pressure 200 kN/m² (net allowable increase)

DIMENSIONS mm
BASE COLUMN
L = 1200 h = 300
B = 1200 b = 250
depth H = 300
ex = 0 ey = 0

COLUMN REACTIONS kN, kNm characteristic Plot (to scale) Key


DEAD IMPOSED WIND
Axial (kN) 150.0 40.0
Mx (kNm) 5.0 5.0
Grnd Brg Pressure 97%
My (kNm) 3.0 3.0
Hx (kN) Bending fsx 63%
Hy (kN)
(As/Asprov) fsy 58%

STATUS VALID DESIGN Shear v xx 23%

v yy 26%

BEARING PRESSURES kN/m² characteristic punching 24%


CORNER 1 2 3 4
0% 25% 50% 75% 100% 125%
no wind 114.7 194.5 83.4 142.4
with wind 114.7 194.5 83.4 142.4 Efficiency

REINFORCEMENT . .
Mxx = 27.9 kNm Myy = 28.9 kNm
b = 1200 mm b = 1200 mm
d = 245 mm d = 235 mm
As = 273 mm² As = 295 mm²
PROVIDE 6 T10 @ 225 B1 PROVIDE 6 T10 @ 225 B2
As prov = 471 mm² As prov = 471 mm²
. .
BEAM SHEAR . .
Vxx = 58.8 kN at d from col face Vyy = 65.8 kN at d from col face
v = 0.200 N/mm² v= 0.233 N/mm²
or Vxx = 0.0 kN at 2d from col face or Vyy = 9.3 kN at 2d from col face
v = 0.000 N/mm² v= 0.033 N/mm²
vc = 0.434 N/mm² vc = 0.445 N/mm²

PUNCHING SHEAR . .
d ave = 240 mm u crit = 3980 mm
As prov = 0.164 % v max = 1.039 N/mm² at col face
v = 0.105 N/mm² vc = 0.439 N/mm²