Metal Detecto Set Up Ceia 02PN8 Series RevA
Metal Detecto Set Up Ceia 02PN8 Series RevA
Tx Rx
Local Programming:
To make any configuration changes under the
32.00in. “User” level press the “PROG” Key then the
“ENTER” key.
PROG ENTER
Enter User Level then
1 NILECJ1
Standard: NILECJ-STD-0610.00
AM9
The Upper coefficient is used to adjust the
Security Level 1
Standard: NILECJ-STD-0610.00
sensitivity of the electromagnetic field emitted by
2 NILECJ2 AM7, AN7
Security Level 2 the antenna at the Upper level
Standard: NILECJ-STD-0610.00
3 NILECJ3 AM5; AN5
Security Level 3
4 NILECJ4
Standard: NILECJ-STD-0610.00
Security Level 4
AM3; AN3;
B6
Factory Value: 0
5 NILECJ5
Standard: NILECJ-STD-0610.00 AM1; AN1 Possible Value: -20 – -1; 0; 1 – 20
Security Level 5 B2
-20 = decrease sensitivity at upper level
OTP and
6 3GUN TST
Standard: 3-GUN-TEST weapons 0 = No change at the upper level
(FAA-USA) foreseen by
the standard +20 = Increase sensitivity at upper level
OTP and
Standard: ENHANCED weapons
7 3GUN TSE
3-GUN-TEST foreseen by
the standard
Useful Width: (UW)
Sphere AISI
This command selects the effective useful width of
8 SPH.44.4 -
420 ∅44.25
the archway, in mm. The correct value is preset in
9 SPH.41.3 -
Sphere AISI
420 ∅41.275
the factory and is indicated in the Factory
Acceptance Test Report which can be found at the
end of the Ceia manual. This command can be
Sensitivity: (SE)
change only on the Ceia 02PN8-Bidirectional
The sensitivity (alarm threshold) of the metal
model.
detector can be adjusted for the requirements of
the metal detector. The SE command can also
Factory Value: 820
modify the IS command to the customer’s request.
Possible Values:
The adjustment of the SE command should be
720mm = 28”
completed with a test piece (listed in table 1) so there
760mm = 30”
is no location the gun can pass through the metal
820mm = 32”
detector without being detected.
International Security Standard Outbound:
Factory Value: 32
(ISO)
Isotec Recommended Value:
For commercial installation using security level 1 the IS
The International Security Standard outbound
command need to be set to 1 and then adjust the SE command is for the reverse (outbound) directions
command to 19 – 25. This recommendation should is only available for the 02PN8-Bidirectional model
only be completed with testing with Level 1 test piece.
Possible Value: 0 – 99 Factory Value: 10
0 = minimum sensitivity, detection of large Possible Values: 1 – 10 (see IS command)
metal masses
99 = Maximum sensitivity, detection of small NOTE: if the 02PN8 Bidirectional model is being used, this
metal masses command selects the International Security Standard to be
applied for transits in the reverse (outbound) direction.
NOTE: if the 02PN8 Bidirectional model is being used, this
command selects the sensitivity (alarm threshold) to be Sensitivity Outbound: (SEO)
applied for transits in the normal (inbound) direction. Sensitivity (alarm threshold) of Metal Detector for the
reverse (outbound) direction is only available for
Super-User Commands:
the 02PN8-Bidirectional model
These following commands should only be used
within conjunction with an Isotec Security factory
Factory Value: 15
representative.
Possible Values: 0 – 99 (see SE command)
Lower Coefficient: (LC) NOTE: if the 02PN8 Bidirectional model is being used, this
The Lower coefficient is used to adjust the command selects the sensitivity (alarm threshold) to be
applied for transits in the reverse (outbound) direction.
sensitivity of the electromagnetic field emitted by
the antenna at the lower level
For more in-depth of all the commands and
Factory Value: 0 troubleshooting please refer to the Ceia 02PN8 HI-
Possible Value: -20 – -1; 0; 1 – 20 PE Installation and Maintenance Manual provided
-20 = decrease sensitivity at lower level with your purchase of the Metal Detector.
0 = No change at the lower level
+20 = Increase sensitivity at lower level