Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Automatically self-tests for disconnection and fire alarm simulation in sequence, saving time for one-by-one checkup.

The digital window (Volts/Info) shows the voltage and it represents various information according to error code definition.
Intelligent pre-alarm function to prevent false alarm.
Smart prevention function to avoid accidentally activating the simulation test.
Built-in annunciator board and it can connect up to 30 annunciators.
Tiny, light and easy-to use, taking up less space than other brands.
Built-in phone jack for communicating. It goes by wire, so it will not be interrupted by tele-signal.

MODEL NO. CM-CP1 MONITORING CURRENT DC 24V 10mA/Zone

ZONE CIRCUIT 5L / 10L WORKING CURRENT DC 24V 24mA/ZONE

DIMENSIONS 330x300x120mm DETECTORS Max. Output: 1.5mA DC24V/ zone

WEIGHT 5KG ZONE BELL OUTPUT DC24V 0.6A

POWER SUPPLY AC 220V 50/60Hz 1.2mm – 2.0mm Steel


CASE MATERIAL plate with powder coating
STAND-BY BATTERY DC 24V

EOL RESISTOR 10KΩ No voltage, N.O. contact


REPORT CONTACT AC 250V, 2A 1set
EXTERNAL CIRCUIT
RESISTANCE To-and-fro below 50Ω
GREEN: Normal power supply
LIGHT INDICATOR
RED: Disconnection or Fire alarm
SOUND OUTPUT 85dB

ITEM REMARK
-T 1 set of phone 2pcs
-A No-voltage contacts Choose 5 zone/ 10 zone,
-B Voltage contacts can install only 1 board
If you want to connect main panel to more than 5
-C Power supply for annunciator annunciators, you will need to add additional power
supply to each main panel.
-G CM-UG201 Smart Wireless App Module

K0L23
CM-CPA

Simple and cost-saving wiring. Only require 5 wires no matter how many zone circuits.

The digital window (Volts/Info) shows the voltage of main panel and it represents various
information according to error code definition.

The zone LED indicators are synchronized with main panel. This increases efficiency to deal with the fire alarm.

Reset button and Silence button can be functioned synchronously with main panel.

Tiny, light and easy-to use, taking up less space than other brands.

Built-in phone jack for communicating with main panel. It goes by wire, so it will not be interrupted by tele-signal.

MODEL NO. CM-CPA

ZONE CIRCUIT 5L / 10L

DIMENSIONS 200x145x62mm

WEIGHT 960g

GREEN: Normal power supply


LIGHT INDICATOR RED: Disconnection or Fire alarm
Equipped with communication device with main panel

Disconnection: Short and soft beep


SOUND Fire Alarm: Long and ding-ding sound

OPTIONAL ACCESSORIES 1 set of phone

Apply to model no.CM-CP1


REMARK
One main panel can connect up to 30 annunciators

*IMPORTANT NOTICE*
1. DO NOT connect to power supply when wiring.
2. The main control panel should be equipped with additional power supply when
it is connected to more than 5 annunciators.

CATALOG NO. CM-CPA_K0L15