B22849az Ja Didcs1zz LSX DR P 0003 P03

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

KEY:

Urban Waste Water


Treatment Installation Bounday
(UWWTD) Import by Sewer
Waste Imports

Sludge Process

Biogas Process
Cess/Domestic Waste Screenings
Tanker Waste Works Inlet
to Off-site Raw Material Inputs
Imports
UWWTD Process

Treated Effluent to Solid Waste Process


UWWTD Process
Discharge Point
Odour Control Units

Primary sludge Liquor Flows


Surplus activated sludge
Abnormal Liquor Return
Sludge Imports
Waste Sludge Flows

SAS Tank Picket Fence OCU 2 3 Water Liquor Return


Thickeners Pumping Station 2 Sludge Abnormal Flows
(A8)
Sludge Import Tank Biogas Flows
Final Effluent
Potable Water 1 Liquor 4 Waste Water
Biogas Abnormal Flows
OCU 1
(A7) Sludge Screens Raw Material Flows
SAS Thickening Sludge Blending
Polymer Plant Tank Raw Material Abnormal Flows

Input to OCU
Sludge Import Screen Sludge Waste Screenings
Buffer Tank Pumping Station to Off-site Dewatering Flows

2 Liquor UWWTD Process Flows


Primary Digester Biogas
Tank Solid Waste Flows
I:\Enviros\Design\PROJECTS\KU\B22849AM\Didcot\Figures\B22849AZ-JA-DIDCS1ZZ-LSX-DR-P-0003-P03.dwg - 16/11/2023 16:01:00 - Layout1 - ALRoberts

5 Condensate
Digested T1 Transfer Points
sludge
S1 Sampling Points
Sludge Imports
Secondary Digester Biogas Storage Boilers
Tank (A17) Natural Gas
(A1 & A2)
Temporary Centifuge
FOR INFORMATION
P03 NOV 2023 AR WL JK MM
FOR INFORMATION
New Gas P02

Rev
OCT 2023

Rev. Date Purpose of revision


AR MM JK

Drawn Checkd Rev'd Apprv'd


MM

Treatment
Emergency Flare
Dewatering Feed Operation 1180 Eskdale Road, Winnersh, Wokingham, RG41 5TU
Cake Pad Buffer Tank
Tel:+44(0)118 946 7000
www.jacobs.com
(A3) Client

Final Effluent
Potable Water
Transport Project
STC IED PERMIT
Off-site DIDCOT STW
Sludge Dewatering Liquor Return Liquor Balancing 6 Liquor Liquor Return
T1
Polymer Plant Pumping Station 3 Tank Pumping Station 1 S1 Drawing title

PROCESS FLOW DIAGRAM

Drawing status
Transport Cake Imports PERMITTING
Cake Pad
Off-site Scale
Jacobs No.
NOT TO SCALE
B22849AZ Rev
DO NOT SCALE

Client no. P03


Drawing number

B22849AZ-JA-DIDCS1ZZ-LSX-DR-P-0003
© Copyright 2020 Jacobs U.K. Limited. The concepts and information contained in this document are the property of Jacobs.
Use or copying of this document in whole or in part without the written permission of Jacobs constitutes an infringement of
copyright. Limitation: This drawing has been prepared on behalf of, and for the exclusive use of Jacobs' Client, and is subject
AD
G
WI N

to, and issued in accordance with, the provisions of the contract between Jacobs and the Client. Jacobs accepts no liability or
TOC

RA

AU
D responsibility whatsoever for, or in respect of, any use of, or reliance upon, this drawing by any third party.

You might also like