Alarm Programming Keyboard Quick Start Guide V1.0.1
Alarm Programming Keyboard Quick Start Guide V1.0.1
Guide
V1.0.1
Table of Contents
1 Overview...................................................................................................... 1
I
Important Safeguards and Warnings
Please read the following safeguards and warnings carefully before using the product in
order to avoid damages and losses.
Note:
Do not expose the device to lampblack, steam or dust. Otherwise it may cause
fire or electric shock.
Do not install the device at position exposed to sunlight or in high temperature.
Temperature rise in device may cause fire.
Do not expose the device to humid environment. Otherwise it may cause fire.
The device must be installed on solid and flat surface in order to guarantee
safety under load and earthquake. Otherwise, it may cause device to fall off or
turnover.
Do not place the device on carpet or quilt.
Do not block air vent of the device or ventilation around the device. Otherwise,
temperature in device will rise and may cause fire.
Do not place any object on the device.
Do not disassemble the device without professional instruction.
Warning:
Please use battery properly to avoid fire, explosion and other dangers.
Please replace used battery with battery of the same type.
Do not use power line other than the one specified. Please use it properly.
Otherwise, it may cause fire or electric shock.
Special Announcement
This manual is for reference only.
All the designs and software here are subject to change without prior written
notice.
All trademarks and registered trademarks are the properties of their respective
owners.
If there is any uncertainty or controversy, please refer to the final explanation of
us.
II
1 Overview
1
2 Installation and Wiring
Use a screwdriver to remote take down rear cover of device by against the two holes at
top of device. See Figure 2-1.
Figure 2-1
Insert cable into cable port at back, see Figure 2-2.
2
Figure 2-2
2.2 Installation
3
Figure 2-3
Figure 2-4
Step 4. Sort cables, and put back rear cover of the device.
4
Figure 2-5
If you want to achieve leaving wall protection function, please fix vandal-proof module of
rear cover on the wall with screw, see Figure 2-6.
Figure 2-6
5
3 Operation (for ARC2008C-(G), ARC2016C-(G))
Warning:
Content of this chapter is keyboard operation of ARC2008C-(G), ARC2016C-(G).
Warning:
The device supports hot swap function. When the controller operates as normal,
connect keyboard wiring end to port at keyboard bottom, the COM indicator flashes
saying the function is normal.
Note:
When you first connect to controller, you need to select language and controller model,
you can use it once being successfully registered to controller.
Step 2. Press key, meantime insert the pair of one end of wire into keyboard
port and power port. Keyboard interface is ON and shoes language option.
button.
6
3.2 Front Panel
Figure 3-1
7
Button or Name Note
Icon
00*123456790 means zone 1-10 in group 00. To
search zone 11-20 alarm info, enter 01 here and so
forth.
0~9 Number key Enter number (0~9)
Symbol(*)
Long press this button,input administrator/operator
*
password, or in homepage, input administration
/operator password to quickly disarm or arm.
Symbol(#)
# Press this button, input administrator/operator
password to cancel alarm
long press this button for 3s,buzzer starts to alarm.
Fire
Device send fire alarm message to controller.
Long press this button key for 3s, buzzer will alarm.
Robber
Device will send alarm message to the alarm controller.
Long press this button for 3s,buzzer will alarm, and
Medical Key device send medial message to controller.
Long press this button for 3s,device will send mute SOS
Mute SOS
message to controller.
Table 3-1
00*1 2 3 4 5 6 7 8 9 0
Figure 3-2
Note:
When check box is blank, zone is normal. When check box is black, zone is in alarm
status. When check box is black and blank, zone is ON (detector triggered).
8
4 Operation (for BUS and video alarm controllers)
Warning:
Content of this chapter is keyboard operation of BUS alarm controller (ARC9016C)
and video alarm controller (ARC5408C, ARC5808C).
Warning:
The device supports hot swap function. When the controller operates as normal,
connect keyboard wiring end to port at keyboard bottom, the COM indicator flashes
saying the function is normal.
Note:
When you first connect to controller, you need to select language and controller model,
you can use it once being successfully registered to controller.
Step 1. Separately connect two ends of wire to keyboard port and power port on alarm
controller.
Step 2. Press key, meantime insert one end of wire into keyboard port.
Keyboard interface is ON and shoes language option.
click button. The keyboard generate a sound, shows homepage and COM
indicator flashes, means auto registration is successful. Keyboard and alarm
controller can have communication.
9
Note:
If you select wrong model, then registration will fail and COM red indicator will NO.
Figure 4-1
Button or Name Note
Icon
Green NO : keyboard successfully registered to
COM indicator alarm controller
Red NO:keyboard not registered to alarm controller
Arm/Disarm Green NO:Arming
Indicator Red NO:Disarming
Show this icon, means device has failure. In global
Failure
mode, you can long press for 3s , to
search device failure status.
Show this icon, means device has alarm. In global
Alarm
mode, long press for 3s,to search current
alarm condition.
Partial Arm Show this icon, means device has partial arming. In
10
Button or Name Note
Icon
# Symbol(#)
11
Button or Name Note
Icon
Valid in any mode.
Long press this button for 3s,device will send mute SOS
message to controller.
Mute SOS
Note:
Valid in any mode.
Confirm setup.
In global mode, long press this button for 3s,it
Enter
shows abnormal status of all zones. Check box next
to zone is black, so the zone is abnormal.
Table 4-1
Figure 4-2
12
Appendix 1 Keyboard Programming Command
ARC2016C-(G)
13
Command Menu Path Programming Operation Definition
Installer set
zone 1 alarm link
0010101+OK+909090
siren output and
enable link
Installer set
zone 1 alarm link
0010001+OK+909090
siren out but
disable link
Installer set
zone 1 alarm link
0011101+OK+909090 alarm output
device and
2. zone > enable link
Link
2-2.Link Installer set
zone 1 alarm link
0011001+OK+909090 alarm output
device but disable
link
Installer set
zone 1 alarm link
0012101+OK+909090
buzzer and
enable link
Installer set
zone 1 alarm link
0012001+OK+909090
buzzer only and
disable link
In subsystem 1,
211001+OK+909090 installer add
zone 1
In subsystem 1,
210001+OK+909090 installer delete
2. zone > 2-3.
Subsystem zone 1
Subsystem
Administrator arm
111+OK+123456
subsystem 1
Administrator
110+OK+123456 disarm
subsystem 1
Installer set
0011+OK+909090 access control 1
3.Access
as anti-pinch
Mode control >
Installer set
3-1.Mode
0012+OK+909090 access control 1
as protection
14
Command Menu Path Programming Operation Definition
Installer set
0012+OK+909090 access control c1
as other
Installer enable
3.Access 0011+OK+909090
access control c1
Control control >
Installer disable
3-2.Control 0010+OK+909090
access control c1
4.Other > Installer reset
Reset 909090
4-1.Reset alarm controller
4.Other > Installer initialize
Initialize 909090
4-2.Initialize alarm controller
Enable keyboard
1
4.Other > tone
Tone
4-3.Tone Disable keyboard
0
tone
Installer set
220150101+OK+909090 system date is
4.Other > 2015/1/1
Time
4-4.Time Installer set
1102222+OK+909090 system time as
10:22:22:
Administrator add
operator 10 , or
110888888+OK+123456 change operator
4.Other >
User 10’s password
4-5.User
888888
Administrator
210+OK+123456
delete installer 10
4.Other > Installer reboot
Reboot 909090
4-6.Reboot alarm controller
Administrator
1+OK+123456
4.Other > enable test mode
Test mode
4-7.Test mode Administrator
0+OK+123456
disable test mode
Installer set ip
1192#168#006#009#+OK+909
address as
090
192.168.6.9
Installer set
5.Communication 2255#255#255#000#+OK+909
Network subnet mask as
> 5-1.Network 090
255.255.255.0
Installer set
3192#168#000#001#+OK+909
gateway as
090
192.168.0.1
15
Command Menu Path Programming Operation Definition
Installer set port
4377777#+OK+909090
as 377777
Installer set 1st
call group number
10571888888886666+OK+909
is
090
05718888888866
66
Installer set 2nd
5.Communication call group number
Call 20571888888666666+OK+909
> 5-2.Call is
090
05718888886666
66
Installer enable
31+OK+909090
call alarm function
Installer disable
30+OK+909090
call alarm function
Installer set 1st
18613576951066+OK+909090 call group number
is 13576951066
Installer set 2nd
28613576951066+OK+909090 call group number
is 13576951066
Installer set 3rd
5.Communication
Sms 38613576951066+OK+909090 call group number
> 5-3.SMS
is 13576951066
Installer set 4th
48613576951066+OK+909090 call group number
is13576951066
Installer set 5th
58613576951066+OK+909090 call group number
is13576951066
Installer enable
11+OK+909090
5.Communication 2g
2g
> 5-5.2G Installer disable
10+OK+909090
2g
5.Communication 909090+any key on remote Installer match
Wireless
> 5-6.Wireless control code of wireless
Installer enable
1+OK+909090
6.Output > siren output
Siren
6-1.Siren Installer disable
0+OK+909090
siren output
16
Command Menu Path Programming Operation Definition
Installer set
20001+OK+909090 zone 1 mode as
auto mode
Installer set
21001+OK+909090 zone 1 mode as
duress mode
Installer set
22001+OK+909090 zone 1 mode as
6.Output > 6-2.
Alarm output off mode
Alarm output
Installer enable
alarm output 1
11001+OK+909090
alarm output
enable
Installer disable
alarm output 1
10001+OK+909090
alarm output
enable
Search zone 1
001
type
Search zone 2
7. status > 7-1. 002
Zone type
zone
Search zone 3
003
type
…… ……
Search access
1 control group
7. status >
Access number
7-2.Access
control Search access
control
2001 control c1 work
mode
Search alarm
programming
7. status >
Version OK keyboard and
7-3.version
alarm controller
current version
Search alarm
7. status >
Time OK controller current
7-4.Time
system time
Search rs485
2+OK+123456
7. status > address
Communicati
7-5.Communicati 11+OK+123456 Search ip address
on
on Search subnet
12+OK+123456
mask
17
Command Menu Path Programming Operation Definition
13+OK+123456 Search gateway
14+OK+123456 Search port no.
7. Status > Search alarm
Controller
7-6.controller OK controller module
status
status status
Search siren
1
7. Status > status
Output
7-7.Output Search output
2001
status
ARC5X08C
18
Scheduled Test pstn scheduled test
Enter
Administrator enter
Programming 123400*4+OK
programming mode
Mode
Add operator 002 ,
Add User 0000028888+OK
password is 8888
Change Change operator 002
0000026666+OK
Password password to be 666
Delete User 001002+OK Delete operator 002
Set operator 002 to
Authorize 0020020+OK
have arm/disarm right
Set alarm controller ip
Local IP
573010015022105+OK address to be
Programming Address
10.15.22.105
Mode
Set alarm controller
Local Port 57437777+OK
port to be 37777
Set alarm controller
Subnet Mask 575255255000000+OK subnet mask to be
255.255.0.0
Set alarm controller
Gateway 576010015000001+OK gateway to be
0.15.0.1
Clear CID
600+OK Clear CID cache
Cache
Exit Current
* Exit current mode
Mode
Enter
Administrator enter
Subsystem 123400*501+OK
subsystem 1
Mode
Bypass 1012003+OK Isolate zone 3
Single Subsystem
Add zone 1 to
Subsystem Accessory 1021001+OK
subsystem 1
Mode Channel
Channel Cancel
104001+OK Cancel zone 1 alarm
Alarm
Exit Current
*+OK Exit current mode
Mode
Enter System Administrator enter
123400*6+OK
Search Mode search mode
Search Alarm
Search Mode Search alarm
Input/Output
下 200+OK input/output channel
Channel
number
Number
Search Zone 201+OK Search total alarm
19
Number zone number
Search Channel Search zone 1
202001+OK
Alarm Status alarm status
Search Channel
Search zone 1
Physical
203001+OK physical mapping
Mapping
address
Address
Search Channel Search zone 1 if
204001+OK
Bypass Status bypass
Search System
Search system
Arm/Disarm 206+OK
arm/disarm status
Status
Search User
207+OK Search user number
Number
Search User Search user
208001+OK
Existence existence
Search Port 209+OK Search port
Search IP
210+OK Search ip address
Address
Search Subnet
211+OK Search subnet mask
Mask
Search Gateway 212+OK Search gateway
Exit Current
*+OK Exit current mode
Mode
Enter Step
123400*7+OK Enter step mode
Mode
Step Mode
Exit Current
*+OK Exit current mode
Mode
20
Note:
This manual is for reference only. Slight difference may be found in user
interface.
All the designs and software here are subject to change without prior written
notice.
All trademarks and registered trademarks are the properties of their respective
owners.
If there is any uncertainty or controversy, please refer to the final explanation of
us.
Please visit our website or contact your local service engineer for more
information.