== XMU
[C-1] 5216x1 + XMU03 x1
[C-2] 5216x1 + XMU03 x2
[C-3] 5216x2 + XMU03 x2
[C-4] 5216x2 + XMU03 x2 + IDLe
[C-5] 5216x2 + XMU03 x2 + IDLe
[C-6] 6630x1 + XMU03x1
[C-7] 6648/6651x1 + XMU03x1
== P614
[D-1] 5216x1 + XMU03x1 + P614x2
[D-2] 5216x2 + XMU03x1 + P614x2 + IDLe (B17+B14)
[D-3] 5216x2 + XMU03x1 + P614x2 + IDLe (B17+B14+B29)
== Two BBU IDLe
[E-1] 5216x1 + 6630x1 + IDLe
[E-2] 6630x2 + IDLe
[E-3] [D-RAN] 5216x1 + XMU03x1 + 6648/6651x1 +IDLe
[E-3-1] [D-RAN] 5216x1 + XMU03x1 + 6648/6651x1 +IDLe (preferred)
[E-4] [D-RAN] 6630x1 + XMU03x1 + 6648/6651x1 +IDLe
[E-4-1] [D-RAN] 6630x1 + XMU03x1 + 6648/6651x1 +IDLe (preferred)
[E-4-2] [D-RAN] 6630x1 + XMU03x1 + 6648/6651x1 +IDLe (exception)
[E-5] [D-RAN] 6630x1 + XMU03x1 + 6648/6651x1 +IDLe (> 3m)
[E-6] 6648/6651x2 +IDLe
[E-7] 6648/6651x2 +IDLe (preferred)
== Three BBU IDLe
[F-1] 6630x3 + IDLe
[F-2] [D-RAN] 5216x1+ XMU03x1 + 6630x1 + 6648/6651x1 +IDLe
[F-3] [D-RAN] 6630x2 + XMU03x1 + 6648/6651x1 +IDLe
[F-4] [D-RAN] 6630x2 + XMU03x1 + 6648/6651x1 +IDLe (> 3m)
[F-5] [D-RAN] 6630x1 + XMU03x1 + 6648/6651x2 +IDLe
[F-6] 6648/6651x3 +IDLe
[F-7] 6648/6651x3 +IDLe (preferred)
== 6675
[G-1] 6630x3 + 6675
[G-2] 6630 + 6675 (>3m)
[G-3] [D-RAN] 6630x3 + 6648/6651 + 6675 (side-haul switch)
== D-RAN 6673
[H-1] [D-RAN] 6630x3 + 6648/6651 + 6673 (side-haul switch)
[H-2] [D-RAN] 6630x4 + 6648/6651 + 6673 (side-haul switch)
== C-RAN 6673
[J-1] [C-RAN] 6630/5216 + 6673 (site FHG)
[J-2] [C-RAN] 6630/5216 + 6673 (site FHG) (3-10m)
[J-3] [C-RAN] 6630/5216 + 6673 (site FHG) (>10m)
[J-4] [C-RAN] 6630x2 + 6673 (site FHG)
[J-5] [C-RAN] 6630x3 + 6673 (site FHG)
[J-6] [C-RAN] 6648/6651 + 6673
[J-7] [C-RAN] 6648/6651 + 6673 (>3m)
Baseband must be connected to at least ports 1 or 2 i.e., connection to port 3 only is not allowed.
Maximum number of XMU03 (R503) per DU or BBU or per node
===========================================================
DUS41: 3
DUS41x2 (IDL2): 3
5216: 6
6630: 6
6648/6651: 6
[C-1] 5216x1 + XMU03x1
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
F E D C B A 5216
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
BBU-XMU electrical cable
(RPM 777 579/L)
L: 00800 (CEQ.18819)
L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
(RPM 777 279/L)
L: 00360 (CEQ.15553)
L: 00650 (CEQ.14829)
F E D C B A IDL B IDL A 5216
L: 01000 (CEQ.11377)
L: 01200 (CEQ.15554)
L: 01800 (CEQ.15214)
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
BBU-XMU electrical cable
(RPM 777 579/L)
L: 00800 (CEQ.18819)
L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
(RPM 777 279/L)
L: 00360 (CEQ.15553)
L: 00650 (CEQ.14829)
5216 L: 01000 (CEQ.11377)
F E D C B A IDL B IDL A
L: 01200 (CEQ.15554)
L: 01800 (CEQ.15214)
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
SFP28
[D-1] 5216x1 + XMU03x1 + P614 x2
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
electrical cable
(RPM 777 579/L)
L: 00800 (CEQ.18819)
L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
electrical
F E D C B A 5216
[D-2] 5216x2 +IDLe + XMU03x1 + P614 x2
DUS-XMU electrical cable
(B17+B14) (RPM 777 579/L)
a b g a b g L: 00800 (CEQ.18819)
L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
B17 B17 B17 B14 B14 B14 (RPM 777 279/L)
L: 00360 (CEQ.15553)
RRH RRH RRH RRH RRH RRH L: 00650 (CEQ.14829)
L: 01000 (CEQ.11377)
L: 01200 (CEQ.15554)
L: 01800 (CEQ.15214)
optical
electrical cable
(RPM 777 579/L)
L: 00800 (CEQ.18819)
to other RRUS L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
master
electrical
slave
electrical cable
(RPM 777 579/L)
L: 00800 (CEQ.18819)
to other RRUS L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
master
electrical
slave
IDL
A B A B C D E F G H J K L M N P Q 6630
IDL
A B A B C D E F G H J K L M N P Q 6630
IDL
A B A B C D E F G H J K L M N P Q 6630
[E-3] 5216x1 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN]
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
QSFP-Xcedex2 cable
(RPM 777 098/L) G3 BBU (6648)
L: 01000 (CEQ.51727) TN A is QSFP28 (4x10GE or 4x25GE):
L: 02000 (CEQ.51724) - Supports up to four E5 lanes
- Requires fanout cable
L: 03000 (CEQ.51728) TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
For SIAD
To C-Band & 3.45GHz radios
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-3-1] 5216x1 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN]
Preferred
For RRUS+A2 w 2 CPRI connections (e.g.
4x1 splitting group 4x1 splitting group 4x1 splitting group 4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
Xcede-1xSFP cable
(RPM 777 544/L)
L: 01000 (CEQ.17819)
L: 02000 (CEQ.17820)
L: 03000 (CEQ.17821)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
To RRUS
For RRUS+A2 w 2 CPRI connections (e.g.
4x1 splitting group 4x1 splitting group 4x1 splitting group 4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
To RRUS optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
For SIAD - Supports up to four E5 lanes
To C-Band & 3.45GHz radios - Requires fanout cable
TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-4-1] 6630x1 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN]
Preferred
For RRUS+A2 w 2 CPRI connections (e.g.
4x1 splitting group 4x1 splitting group 4x1 splitting group 4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
Xcede-1xSFP cable
(RPM 777 544/L)
L: 01000 (CEQ.17819)
L: 02000 (CEQ.17820)
L: 03000 (CEQ.17821)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
For SIAD - Supports up to four E5 lanes
To C-Band &3.45 GHz radios - Requires fanout cable
TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-4-2] 6630x1 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN] (NR-CA only)
Exception
For RRUS+A2 w 2 CPRI connections (e.g.
4x1 splitting group 4x1 splitting group 4x1 splitting group 4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
Xcede-1xSFP cable
(RPM 777 543/L)
L: 01000 (CEQ.44902)
L: 02000 (CEQ.44899)
L: 03000 (CEQ.44900)
TN/IDL
A B C D A B C D E F G H J K L M 6648
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
For SIAD - Supports up to four E5 lanes
To C-Band & 3.45GHz radios - Requires fanout cable
TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-5] 6630x1 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN] (> 3m)
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(R503)
RDH10265/1
(CEQ.22091) Coupler
1061260310
(CEQ.51730)
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
For SIAD - Supports up to four E5 lanes
To C-Band/3.45 GHz radios - Requires fanout cable
TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-6] 6648/6651x2 + IDLe [D-RAN]
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
To Subb-3 radios
TBD
QSFP28-QSF28 cable
(RPM 777 053/L)
L: 01000 (CEQ.49092)
L: 02000 (CEQ.49094)
L: 03000 (CEQ.49091)
TN/IDL
A B C D A B C D E F G H J K L M 6648
To Subb-3 radios
For SIAD
To C-Band & 3.45GHz radios
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[E-7] 6648/6651x2 + IDLe [D-RAN]
(preferred)
TBD
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
To Subb-3 radios
TN/IDL
A B C D A B C D E F G H J K L M 6648
To Subb-3 radios
For SIAD
To C-Band & 3.45GHz radios
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[F-1] 6630x3 + IDLe
TBD
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
optical
XMU03
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BBU-XMU electrical cable
(R503)
(RPM 777 579/L)
L: 00800 (CEQ.18819)
L: 02000 (CEQ.18820)
L: 03000 (CEQ.18821)
(RPM 777 279/L)
L: 00360 (CEQ.15553)
L: 00650 (CEQ.14829)
L: 01000 (CEQ.11377)
5216 L: 01200 (CEQ.15554)
F E D C B A IDL B IDL A
L: 01800 (CEQ.15214)
IDL
A B A B C D E F G H J K L M N P Q 6630
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
- Supports up to four E5 lanes
For SIAD - Requires fanout cable
TN B, C and D are SFP28 (10GE or 25GE):
To C-Band/3.45 GHz SFP28 - Can support one or two E5 lanes
radios
SFP3 or SFP7, no high-temp rated SFP is required
[F-3] 6630x2 + XMU03x1 + 6648/6651x1 + IDLe
[D-RAN]
For RRUS+A2 w 2 CPRI connections (e.g.
4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
4x1 splitting group 4x1 splitting group 4x1 splitting group
optical
IDL
A B A B C D E F G H J K L M N P Q 6630
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
- Supports up to four E5 lanes
For SIAD - Requires fanout cable
To C-Band & 3.45 GHz radios TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[F-4] 6630x2 + XMU03x1 + 6648/6651x1 + IDLe (> 3m)
[D-RAN]
IDL
A B A B C D E F G H J K L M N P Q 6630
RDH10252/7
(TBD) RPM2534891/L
(TBD) 1061260310 RPM777811/03000
(CEQ.51730) (CEQ.18333)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
For SIAD
To C-Band/3,45 GHz
radios
[F-5] 6630x1 + XMU03x1 + 6648/6651x2 + IDLe
[D-RAN]
For RRUS+A2 w 2 CPRI connections (e.g.
4W RX > 10 MHz), both CPRI’s must
connect to the same splitting group
4x1 splitting group 4x1 splitting group 4x1 splitting group
optical
To Subb-3 radios
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
QSFP28-QSFP28 cable
(RPM 777 053/L)
L: 01000 (CEQ.49092)
L: 02000 (CEQ.49094)
L: 03000 (CEQ.49091)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
G3 BBU (6648)
TN A is QSFP28 (4x10GE or 4x25GE):
- Supports up to four E5 lanes
For SIAD - Requires fanout cable
To C-Band & 3.45 GHz radios TN B, C and D are SFP28 (10GE or 25GE):
- Can support one or two E5 lanes
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[F-6] 6648/6651x3 + IDLe [D-RAN]
TBD
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
QSFP28-QSF28 cable
(RPM 777 053/L)
L: 01000 (CEQ.49092)
L: 02000 (CEQ.49094)
L: 03000 (CEQ.49091)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
To Subb-3 radios
To C-Band/3.45 GHz
radios
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[F-7] 6648/6651x3 + IDLe [D-RAN]
(preferred)
TBD
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
To Subb-3 radios
To C-Band/3.45 GHz
radios
SFP28
SFP3 or SFP7, no high-temp rated SFP is required
[G-1] 6630x3 + 6675
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
6675
IDL
A B A B C D E F G H J K L M N P Q 6630
IDL
A B A B C D E F G H J K L M N P Q 6630
IDL
A B A B C D E F G H J K L M N P Q 6630
IDL
A B A B C D E F G H J K L M N P Q 6630
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
6675
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
6673
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
6673
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
No separate
SFP is needed.
[J-1] 6630 + 6673 (C-RAN)
6673
odd even
LTE NR
Xcedex-SFPx2 cable
(RPM 777 544/L)
L: 01000 (CEQ.17819)
L: 02000 (CEQ.17820)
L: 03000 (CEQ.17821)
IDL
A B A B C D E F G H J K L M N P Q 6630
can be 5216
[J-2] 6630 + 6673 (3-10m) (C-RAN)
6673
odd even
LTE NR
Xcedex-LCx4 cable
(RPM 777 811/L)
L: 05000 (CEQ.53563)
L: 10000 (CEQ.53564)
IDL
A B A B C D E F G H J K L M N P Q 6630
can be 5216
[J-3] 6630 + 6673 (>10m) (C-RAN)
6673
odd even
LTE NR
RDH 102 65/1
(CEQ.22091)
1061260310 coupler
(CEQ.51730)
Xcedex-LCx4 cable
(RPM 777 811/L)
L: 03000 (CEQ.18333)
IDL
A B A B C D E F G H J K L M N P Q 6630
can be 5216
[J-4] 6630x2 + 6673 [C-RAN]
TBD
1/1 1/2 1/3 1/4 1/5 1/6 1/7 1/8 3/1 3/2 3/3 3/4 3/5 3/6 3/7 3/8
BBU#1 TN
BBU#2 TN
To C-Band/DoD radios
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
BBU#2
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
BBU#1
No separate
SFP is needed.
- Make Xcede to 2 SFPs connections to 6673 (RPM777 544/L ) to G2 BBs. Conn A1: LTE ERAN in odd
slots. Conn A2: NR ERAN in even slots.
- Deploy 1xRPM77544/L per FDD Baseband. Connect the SM LTE BB on 3/1 (LTE-CA) and 3/2 (NR-
CA). Connect the MM BB on 3/3 (LTECA) and 3/4 (NR-CA).
- On Route Processor Card deploy one eCPRI per AAS radio (both C-Band and DoD) also use for LTE
Rehome (TN for FDD Basebands).
- Deploy the Site-GW (Macro FHG) in the same Rack or Purcell Cabinet as the FDD Basebands.
[J-5] 6630x3 + 6673 [C-RAN]
TBD
1/1 1/2 1/3 1/4 1/5 1/6 1/7 1/8 3/1 3/2 3/3 3/4 3/5 3/6 3/7 3/8
BBU#1 TN
BBU#2 TN
BBU#3 TN
To C-Band/DoD radios
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
BBU#3
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
BBU#2
IDL
A B A B C D E F G H J K L M N P Q 6630 can be 5216
BBU#1
No separate
SFP is needed.
- Deploy the Site-GW (Macro FHG) in the same Rack or Purcell Cabinet as the FDD Basebands.
- Make Xcede to 2 SFPs connections to 6673 (RPM777 544/L ) to G2 BBs. Conn A1: LTE ERAN in odd
slots. Conn A2: NR ERAN in even slots.
- On Route Processor Card deploy one eCPRI per AAS radio (both C-Band and DoD) also use for LTE
Rehome (TN for FDD Basebands).
- Connect the TN for the Beta Sector (3rd BB) on Slot 3/8 of the Ethernet Card.
[J-6] 6648/6651 + 6673 (C-RAN)
6673
odd even
LTE NR
SFP28-SFP28
(RPM 777 052/L)
L: 01000 (CEQ.51731)
L: 02000 (CEQ.51726)
L: 03000 (CEQ.51729)
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
[J-7] 6648/6651 + 6673 (> 3m) (C-RAN)
6673
odd even
TN/IDL
A B C D A B C D E F G H J K L M 6648/6651
D X
U M
S U
/
B
B X
IDL(e) M
D U
U
S
/ X
B M
B U
IDL
A B A B C D E F G H J K L M N P Q 6630
TN/IDL
A B C D A B C D E F G H J K L M 6648