Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Done By:- KK Job No:-ACME-J-228-Unit-2 Shed-Estimate-R0 Date :- 05-08-2022

Roof Area = 2091 m2


Canopy Area = 84 m2
1. Building Parameters
S.NO DESCRIPTION DETAILS
1 LOCATION Vadodara, Gujrat
2 BUILDING TYPE Multi Span-1 (Monoslope)
3 WIDTH 50.0 m C/C of Steel Column.
4 LENGTH 40.0 m C/C of Steel Column.
5 HEIGHT 7.0 m Clear Height
6 ROOF SLOPE 1:23
7 WIDTH MODULE 2 @ 25.0 m
8 BAY SPACING As per Drawing.
9 FUTURE EXPANSION Non Expandable
10 ENDWALL BAY SPACING As per Drawing.
11 BRACING Cross Rod Bracing for Roof & Wall.
12 WALL CONDITION 3.0m High Brick Wall & above Sheeting .
13 STEEL GRADE FY-345 Mpa
14 DESIGN VERSION STAAD.Pro V8i (SELECT Series 6)

EOT CRANE NA
CANOPY 6 Nos. (2.0m x bay spacing)
FRAMED OPENINGS 6 Nos. (4.0m x 4.0m)
MEZZANINE NA
OTHER DETAILS
INSULATION ROOF NA
WALL NA
ACCESSORIES Skylights Wall Light Ridge Vent Turbo Vent
12 Nos. (1.0M X 3.0M) NA NA 12 Nos.

2. Design Data
Dead Load Live Load Wind Load Collateral Load
DESIGN LOADS, KN/M2
0.1 0.57 39 m/sec 0.2
Frames Purlins Girts Crane Beam
SERVICEABILITY CRITERIA
H/100, L/180 L/180 L/120
DESIGN
CRITERIA Bridge Weight Trolley Wt. Wheel Load Wheel Base
CRANE DATA

MEZZANINE LOAD kN/m2 Dead Load Live Load Deflection


- - -
CODES AISC/AISI/MBMA/IS:1893-2002

3. Indicative Tonnage
Description Weight in Kg Remarks
Primary Steel 30388 All Built-up Members
Mezzanine Beam 0 Including mezz. main beams, Joist & columns.
Crane Beam 0 Including crane beam,cap angle & connections
Staircase 0
Anchor Bolts 800
Connection Bolts 850
Secondary Steel 13752 Including Coldformed members & Flange bracings
Hot Rolled Members 940 Clips, Pipes & tubes
Roof Sheeting 10238 0.47MM thick Bare galvalume panel
Roof / Wall Accessories 793 Including All trims, Gutter & Downspouts
Wall Cladding 5067 0.50MM thick Color Coated panel
Rod bracing+Sag rod 2028
Other Wall Accessories 0
Decking Panels 0 0.8mm thick deck sheet
Louver 0
Grand Total 64856.36 Kgs

4. Special Notes

1. Building is designed as an Enclosed building.


2. Purlins & Girts are considered of minimum thickness size (200Z1.5) mm Depth.
3. Main Frame column bases & Wind column bases are Pinned.
4. Building is designed as per AISC-2010 (ASD).
5. Building class B considered for wind pressure calculations.
6. Cross rod bracing considered along both sidewalls & internal column location.
7. Gutter & Downspouts considered.
8. Framed openings are considered.
9. Rod bracing considered over roof and same is designed as tension member only.
10. Two Sets of braced bay considered in the Shed.
11. Canopy without soffit panel considered.
12. Seismic zone III considered.
13. Wind Load is as per MBMA-2006. (Wind Pressure=0.555 Kn/m2)
14. Minimum Built up member thickness 5.0 mm considered.
15. Tonnage can be vary by +/-3%.