FC-07274 Burst Test Report
FC-07274 Burst Test Report
É DANAK
INSP Reg.nr.9057
Certification
Referring to your e-mail of 2019-09-05 two items delivered to us have been pressure tested as stated below
The items were delivered to us with the following information
Applied procedure
1. Pressurization to 450 bar - holding 30 minutes.
2, Depressurization and checking item.
3. Pressurization to 675 bar - holding 30 minutes.
4. Depressurization and checking item,
5. Pressurization to bursting.
The pressurization was made by using water at about 20oC and using a pressure increase rate of about 5
bar per second,
The pressure was measured with our class 0,6 pressure gauge No. MOLV-6 calibrated 2078-12-12.
Results:
The items did not show any defects by the checking under step 2 and 4 of the procedure,
No. 6:
1544 barg
No. 10: 1760 barg
Kind regards