Professional Documents
Culture Documents
SolarWinds Polling Engine Overview
SolarWinds Polling Engine Overview
Hosting.................................................................................................................................... 6
Overview ................................................................................................................................... 6
Location .................................................................................................................................... 6
Power ........................................................................................................................................ 6
Climate ...................................................................................................................................... 7
Security ..................................................................................................................................... 7
Fire Prevention ......................................................................................................................... 7
Certificates ............................................................................................................................... 7
Network & Connectivity ........................................................................................................... 7
Servers ...................................................................................................................................... 8
Backups .................................................................................................................................... 8
Incident Response/Disaster Recovery ................................................................................... 8
Best Practice
With the use case of having to monitor multiple segregated client networks, the best
practise is implementing SolarWinds monitoring to a cloud hosted platform, with the use
of additional polling engines operating within the internal client network to extend the
centralized monitoring across remote sites.
A connection is created between the primary and remote sites using APE. The APE
collects the monitored data from nodes, and continually transmits the data to the orion
platform server.
Each APE uses Microsoft Message Queuing (MSMQ) to cache data locally on the polling
engine.
In the event of connectivity loss to the Orion platform, the data is cached locally and
synced back to the Orion SQL database once the connection is restored.
The amount of data that may be cached depends on the amount of disk space available
on the polling engine.
The below image illustrates the best practice configuration for additional polling engines.
Requirements
The following is required from the customer to install and run the Additional Polling
Engine (APE).
Network Latency
The latency (RTT) between each APE and the Orion Server should be below 200 ms.
Hosting
Overview
Our hosting requirements are being fulfilled by HostAfrica. They are rated the top ISP on
Hello Peter and have the highest rated support department, which was the biggest
determining factor for us when selecting a hosting provider.
Location
The servers are hosted in the Xneelo Samrand Data Centre Park. The facility is not in a
direct flight path or low-lying area and is centrally located between Johannesburg and
Pretoria with a major power substation close by.
Power
An 11kV power supply from the municipal power utility energises a fault-tolerant, medium-
voltage ring that powers two separate low-voltage 2MVA energy centres.
They have on-site fuel storage sufficient to run our generators for 7 days’ continuously.
The UPS’s provide always-on power, with a battery standby time of 30 minutes.
Security
The perimeter fence is backed by high voltage barriers, supported by the latest video
surveillance technology and response systems.
All access zones inside and outside the data centre, including racks, are monitored by
video surveillance.
Fire Prevention
The facility is custom-designed for low fire risk, with a Very Early Smoke Detection
Apparatus (VESDA) installed to trigger alarms at even the slightest hint of smoke
particles.
There are no flammable materials present in the ‘white space’ in the Data Centre and all
cabling is fire-retardant.
Certificates
SAQ D
Backups
Server is backed up on a weekly basis using Acronis backup agents.