C-FIX Online 1.1.52.

0
Database version 1.1.52.0
Date 27/06/2023

Deutschland
fis che r fixings UK Ltd
Whitely Road; Hithercroft Industrial Estate
Wallingford; Oxfordshire; OX10 9AT
technical@fischer.co.uk

Design specifications
Anchor
Anchor system fischer bolt anchor FAZ II
Fixing element FAZ II 10/10,
gvz
Anchorage depth 40 mm
Design data ETA-05/0069 (24.04.2020)

Units of Measurement
Geometry mm
Design action values kN, kNm

Not draw n to s cale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 1
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Input Data
Design method EN 1992-4:2018
Base material Normal weight concrete, C30/37, EN 206:2013
Concrete condition Cracked, Dry hole
Temperature range 24 °C Long term temperature, 40 °C Short term
temperature
Reinforcement No or standard reinforcement, No edge reinforcement,
With reinforcement to control splitting
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Not filled
Type of loading Static or quasi-static
Base plate location Base plate with non bearing layer
Base plate geometry 150 mm x 122 mm x 8 mm
Profile type None

Design actions incl. partial safety factor of the load


Case NEd VEd,x VEd,y MEd,x MEd,y MEd,z Type of loading Name
kN kN kN kNm kNm kNm
1 -3.66 0.00 1.41 -0.76 0.00 0.00 Static or quasi-static

Resulting anchor forces


Anchor no. Tensile action Shear action Shear action x Shear action y
kN kN kN kN
1 5.23 0.71 0.00 0.71
2 5.23 0.71 0.00 0.71

Max. concrete compressive strain 0.26 ‰


Max. concrete compressive stress 8.66 N/mm²
Resulting tensile actions 10.46 kN, X/Y position (0 / 0 mm)
Resulting compression actions 14.12 kN, X/Y position (0 / 54 mm)

Resistance to tension loads


Proof Action Capacity Utilisation βN
kN kN %
Steel failure * 5.23 18.87 27.7
Pullout failure * 5.23 10.57 49.5
Concrete cone failure 10.46 13.09 79.9
* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 2
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Steel failure
NRk,s
NEd ≤ NRd,s = γMs
NRk,s γMs NRd,s NEd βN,s
kN kN kN %
28.30 1.50 18.87 5.23 27.7

Anchor no. βN,s Group N° Decisive β


%
1 27.7 1 βN,s;1
2 27.7 2 βN,s;2

Pullout failure
NRk,p
NEd ≤ NRd,p = γMp
NRk,p ψc γMp NRd,p NEd βN,p
kN kN kN %
15.86 1.22 1.50 10.57 5.23 49.5

The given Psi,c-factor may have been determined by interpolation.

Anchor no. βN,p Group N° Decisive β


%
1 49.5 1 βN,p;1
2 49.5 2 βN,p;2

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 3
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Concrete cone failure


NRk,c
NEd ≤ NRd,c = γMc
Ac,N (7.1)
0
NRk,c = NRk,c ∙ 0 ∙ ψs,N ∙ ψre,N ∙ ψec,N ∙ ψM,N
Ac,N
2
NRk,c = 10.67 k N ∙ 24000 mm2 ∙ 1.000 ∙ 1.000 ∙ 1.000 ∙ 1.104 = 19.63 k N
14400 mm
0 (7.2)
NRk,c = k1 ∙ fck ∙ hef1.5 = 7.7 ∙ 30.00 N / mm2 ∙ (40 mm)1.5 = 10.67 k N

A0c,N = scr,N ∙ scr,N = 120 mm ∙ 120 mm = 14400 mm2 (7.3)

ψs,N = min 1; 0.7 + 0.3 ∙ c c = min 1; 0.7 + 0.3 ∙ 65 mm


(7.4)
= 1.000 ≤ 1
cr,N 60 mm
ψre,N = 1.000 (7.5)

ψec,N = 1 ⇒ ψec,Nx ∙ ψec,Ny = 1.000 ∙ 1.000 = 1.000 ≤ 1


(7.6)
2 ∙ eN
1+ s
cr,N

ψec,Nx = 1 = 1.000 ≤ 1 ψec,Ny = 1 = 1.000 ≤ 1


1 + 2 ∙ 0 mm 1 + 2 ∙ 0 mm
120 mm 120 mm
ψM,N = 1.104 (7.7)

NRk,c γMc NRd,c NEd βN,c


kN kN kN %
19.63 1.50 13.09 10.46 79.9

Resistance to shear loads


Proof Action Capacity Utilisation βV
kN kN %
Steel failure of bolt w ith lever arm * 0.71 1.58 44.5
Concrete pryout failure 1.41 30.82 4.6
Concrete edge failure 1.41 7.08 19.9
* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 4
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Steel failure of bolt with lever arm


VRk,s,M
VEd ≤ VRd,s,M = γMs
αM ∙ MRk,s (7.37)
VRk,s,M = = 1 ∙ 37.59 Nm = 1.98 k N
la 19 mm
0
MRk,s = MRk,s ∙ (1 − NEd / NRd,s ) = 52.00 Nm ∙ (1 − 5.23 k N / 18.87 k N) = 37.59 Nm (7.38)

VRk,s,M γMs VRd,s,M VEd βV,s,M


kN kN kN %
1.98 1.25 1.58 0.71 44.5

Anchor no. βV,s,M Group N° Decisive β


%
1 44.5 1 βV,s,M;1
2 44.5 2 βV,s,M;2

Concrete pryout failure


VRk,cp
VEd ≤ VRd,cp = γMc
VRk,cp = k 8 ∙ NRk,c = 2.6 ∙ 17.78 k N = 46.23 k N (7.39a)

Ac,N (7.1)
0
NRk,c = NRk,c ∙ 0 ∙ ψs,N ∙ ψre,N ∙ ψec,N ∙ ψM,N
Ac,N
2
NRk,c = 10.67 k N ∙ 24000 mm2 ∙ 1.000 ∙ 1.000 ∙ 1.000 ∙ 1.000 = 17.78 k N
14400 mm
0 (7.2)
NRk,c = k1 ∙ fck ∙ hef1.5 = 7.7 ∙ 30.00 N / mm2 ∙ (40 mm)1.5 = 10.67 k N

A0c,N = scr,N ∙ scr,N = 120 mm ∙ 120 mm = 14400 mm2 (7.3)

ψs,N = min 1; 0.7 + 0.3 ∙ c c = min 1; 0.7 + 0.3 ∙ 65 mm


(7.4)
= 1.000 ≤ 1
cr,N 60 mm
ψre,N = 1.000 (7.5)

ψec,N = 1 ⇒ ψec,Nx ∙ ψec,Ny = 1.000 ∙ 1.000 = 1.000 ≤ 1


(7.6)
2 ∙ eN
1+ s
cr,N

ψec,Nx = 1 = 1.000 ≤ 1 ψec,Ny = 1 = 1.000 ≤ 1


1 + 0 mm
2 ∙ 1 + 0 mm
2 ∙
120 mm 120 mm
ψM,N = 1.000 (7.7)

VRk,cp γMc VRd,cp VEd βV,cp


kN kN kN %
46.23 1.50 30.82 1.41 4.6

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 5
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Concrete edge failure


VRk,c
VEd ≤ VRd,c = γMc
Ac,V (7.40)
0
VRk,c = VRk,c ∙ 0 ∙ ψs,V ∙ ψh,V ∙ ψα,V ∙ ψec,V ∙ ψre,V
Ac,V
2
VRk,c = 7.53 k N ∙ 26813 mm2 ∙ 1.000 ∙ 1.000 ∙ 1.000 ∙ 1.000 ∙ 1.000 = 10.62 k N
19013 mm
0
VRk,c = k 9 ∙ dnomα ∙ lf β ∙ fck ∙ c11.5 (7.41)

0
VRk,c = 1.7 ∙ (10 mm)0.078 ∙ (40 mm)0.069 ∙ 30.00 N / mm2 ∙ (65 mm)1.5 = 7.53 k N
lf 40 mm dnom 0.2 0.2 (7.42)
α = 0.1 ∙ c1 = 0.1 ∙ = 0.078 β = 0.1 ∙ c1 = 0.1 ∙ 10 mm = 0.069
65 mm 65 mm
c2 98 mm (7.45)
ψs,V = min 1; 0.7 + 0.3 ∙ = min 1; 0.7 + 0.3 ∙ = 1.000 ≤ 1
1.5 ∙ c1 1.5 ∙ 65 mm
1.5 ∙ c1 1.5 ∙ 65 mm
(7.46)
ψh,V = max 1; = max 1; = 1.000 ≥ 1
h 215 mm

ψα,V = 1 = 1 = 1.000 ≥ 1
(7.48)
( cos αV)2 + (0.5 ∙ sin αV)2 ( cos 0.0)2 + (0.5 ∙ sin 0.0)2

ψec,V = 1 = 1 = 1.000 ≤ 1
(7.47)
2 ∙ eV 1 + 2 ∙ 0 mm
1+ 3 ∙ 65 mm
3 ∙ c1
ψre,V = 1.000 7.2.2.5 (13)

VRk,c γMc VRd,c VEd βV,c


kN kN kN %
10.62 1.50 7.08 1.41 19.9

Utilisation of tension and shear loads


Tension loads Utilisation βN Shear loads Utilisation βV
% %
Steel failure * 27.7 Steel failure of bolt w ith lever arm * 44.5
Pullout failure * 49.5 Concrete pryout failure 4.6
Concrete cone failure 79.9 Concrete edge failure 19.9
* Most unfavourable anchor

Utilization to tensile and shear loads, as well as interaction

Interaction concrete
Decisive utilisation for tensile loads βN,c/p = 0.80 ≤ 1
Decisive utilisation for shear loads βV,c/p = 0.20 ≤ 1
1.5 1.5
Decisive utilisation for the interaction βNV,c/p = βN,c/p + βV,c/p = 0.80 ≤ 1

Proof successful

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 6
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Technical remarks
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state
and the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of
the actions introduced by the anchors. For these verifications the additional provisions given in the current design method
shall be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. C-FIX offers a special module to determine a sufficient base plate stiffness. Utilisation is recommended.

During the design, the following messages were issued:


• According to EN1992-4 7.2.2.5 (1) for stand-off installation, all component edges should be > max(10 · hef; 60 · d) = 600
mm.

Legal provisions
All information and data contained in the programs refer exclusively to the Use of fischer products and based on the
principles, formulas and safety regulations in accordance with the technical instructions and fischer''s operating, setting
and assembly instructions etc., which must be strictly observed by the user. All values contained are average values;
therefore, application-specific tests must always be carried out before using the respective fischer product. The results of
the calculations carried out using the software are based mainly on the data you enter. You therefore bear sole
responsibility for the accuracy, completeness and relevance of the data you enter. You are still solely responsible for
checking the results of the calculation to have it checked and approved by a specialist before use for your specific system
(s), especially with regard to conformity with applicable standards and approvals. The dimensioning program serves
merely as an aid for the interpretation of standards and approvals without any guarantee of accuracy, correctness and
relevance of results or suitability for a particular application. The user must take all necessary and reasonable measures
to prevent damage caused by the to prevent or limit the design program. In particular, for regular backups, you must of
programs and data as well as regular updates of the software offered by fischer, if necessary. Carry out design program.
Unless you use the automatic update function of the software, you have to m'+'ake sure by manual updates via the fischer
website that you always have the current and therefore use a valid version of the design program. Insofar as you culpably
breach this obligation if the goods are damaged, fischer is not liable for the consequences, in particular not for the
replacement of the goods lost or damaged data or programs.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 7
C-FIX Online 1.1.52.0
Database version 1.1.52.0
Date 27/06/2023

Installation data
Anchor
Anchor system fischer bolt anchor FAZ II
Fixing element FAZ II 10/10, Art.-No. 094981
gvz
Accessories FABS Art.-No. 077937
FA-ST II M10 Art.-No. 558790
FA-ST II Set Art.-No. 558789
FA-ST II Feder Art.-No. 558793
Blow-out pump AB G Art.-No. 567792
Hammer drill Quattric II 10/100/165 Art.-No. 549922
Hollow drill FHD 10/100/230 Art.-No. 559943

Installation details
Size M10
Drill hole diameter d0 = 10 mm
Drill hole depth h2 = 75 mm
Anchorage depth hef = 40 mm
Drilling method Hammer drilling
Drill hole cleaning Only blow out by hand
When using a hollow drill (e.g. FHD), no cleaning is
necessary.
Installation type Push-through installation
Annular gap Not filled
Installation torque Tinst = 45 Nm
Wrench size SW = 17 mm
Base plate thickness t = 8 mm
Layer thickness g = 10 mm
Maximum possible fixing tfix,max = 30 mm
thickness
Maximum possible levelling tfix,max - tfix = 12 mm
layer

Base plate details


Units of Measurement Geometry: mm
Base plate thickness t = 8 mm
Clearance hole diameter df = 12 mm

Anchor coordinates
Anchor no. x y
mm mm
1 -40 0
2 40 0

Attachment
Profile type None
Steel grade S235

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of
warranty in the license agreement of the Software.

Page 8