260 14.00
Atlas Copco Filter Frame Size 260
Atlas Copco Filter Type DD DD
12.00
Oil Carryover 0.1 mg/m³
Nominal pressure drop (new) 0.05 bar
10.00
Nominal pressure drop (saturated) 0.12 bar
With AC Filter
Nominal flow 260 l/s 8.00
From
Compres-
6.00 sor
Actual Flow 280 l/s
Actual pressure drop (new) 0.06 bar psi
4.00
Actual pressure drop (saturated) 0.14 bar
Oil carryover per week 9.102 ml 2.00
Quality of air
3 Time to reach pressure drop of 0,35 bar 0,45 bar
Ideal tim e to change your filter elem ent
3000
specify it myself 10000 h 10000 h
2500
filter 3 DDp
DDp 361.59 EURO 4176 0.9 1114.81 EURO 1000
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Total costs during one year 7929.99 EURO
DD hours used
DDp QD
Currency and Power Cost Dialogue
1 kW = 0.07 EURO
Number Type Price of filter element in EURO
1 9 75.45
2 17 108.19
3 32 138.09
4 44 159.44
5 60 193.61
6 120 234.89
7 150 254.82
8 175 271.91
9 260 361.59
10 390 444.16
11 520 509.65
12 520F 1426.44
13 780F 1901.92
14 1050F 2377.40
15 1400F 3328.35
16 1800F 3803.83
17 2100F 4754.79
18 2700F 5705.75
19 3150F 5705.75
20 4800F 7607.66
21 7200F 11411.50
The sheet Cost and hours of usage calculation will calculate the ideal time to replace your filter elements. To do this calculation some parameters a
- the average extra joule per liter when there is a pressure drop of one bar
- the kind of filterelements you want to use
- the capacity of the filter can be changed on the sheet "Filter Pressure Drop & Oil Carryover Calculator"
How fast the filter is spoilt depends on the quality of the air taken in. When you fill in that you have clean air this program assumes that the pressu
8000 h. When the air is filthy that point will already be reached after 4000 hours. After that point the slope will become much steeper. You can also
the pressure drop of 0,35 and 0,45 is reached .
o this calculation some parameters are needed: - the price of electricity
his program assumes that the pressure drop point of 0,35 is reached after
l become much steeper. You can also fill in yourself after how many hours