Nylon Tubing

Series T/TIA
RoHS
For general pneumatic Model  — 20 m roll  — 100 m roll (T1613 is reel.)
tubing, Nylon tubing Tubing size
Metric size (Series T) Inch size (Series TIA)
Max. Operating Pressure Model T0425 T0403 T0604 T0645 T0806 T1075 T1209 T1613 TIA01 TIA05 TIA07 TIA11 TIA13
3.6 Tubing O.D. (mm) 4 4 6 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7
3.4 T0425 Tubing I.D. (mm) 2.5 3 4 4.5 6 7.5 9 13 2.18 3.48 4.57 6.99 9.56
3.2
T0604
3.0 Black (B)
Max. operating pressure (MPa)

2.8
2.6 White (W)
2.4 Series TIA
2.2 Red (R)
2.0
1.8
Blue (BU)
T1613
1.6 Yellow (Y)
1.4
1.2 Green (G)
1.0 T0403
0.8 Nominal size (inch)
0.6
Other metric size
5 32 " 5 16 " 18" 3 16 " 1 4 " 3 8 " 1 2 "
0.4
0.2
0.0 Nominal
−40 −20 0 20 40 60 80 100 size (mm)

Operating temperature (°C) Specifications 3.2

Fluid Air/Water
20°C or less 3.3 2.0 3.0 2.0 2.0 2.0 2.0 1.6 2.3 2.3 2.3 2.3 2.3
How to measure the minimum bending radius. Max. operating 40°C 2.3 1.4 2.1 1.4 1.4 1.4 1.4 1.1 1.6 1.6 1.6 1.6 1.6
2R pressure Note 1) 60°C 1.65 1.0 1.5 1.0 1.0 1.0 1.0 0.8 1.15 1.15 1.15 1.15 1.15
(MPa) 80°C 1.35 0.8 1.25 0.8 0.8 0.8 0.8 0.65 0.95 0.95 0.95 0.95 0.95
100°C 1.2 0.75 1.1 0.75 0.75 0.75 0.75 0.6 0.85 0.85 0.85 0.85 0.85
Applicable fittings Note 1) Note 2) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
Min. bending
Min. bending radius 13 20 24 30 40 50 60 100 15 25 30 50 65
Fixed end

radius
(mm) Note 3) Bending value
(Reference) 10 15 18 23 30 40 45 75 12 20 23 40 48
Operating temperature Note 1) −40 to +100°C, Water: 0 to +70°C (No freezing)
Material Nylon 12
Note 1) Be sure to operate under the maximum operating pressure conditions using the lower maximum op-
erating specification of either the tubing or fittings.
At a temperature of 20°C, bend the tub- Note 2) Mount an inner sleeve when using metal One-touch fittings in high-temperature environments of
ing into a U shape. Fix one end and grad- 60°C or more. Use self-align fittings at a temperature of 60°C or less.
ually move the other end closer. Measure Note 3) The minimum bending radius is the representative value measured as shown in the left figure.
2R at the point where the outside diame- • Use a tube above the recommended minimum bending radius.
ter's rate of change is 10%. • The tubing may be bent if used under the recommended minimum bending radius.
Therefore, refer to the refraction value and make sure that the tubing is not bent or flattened.
• Please note that the refraction value is not warranted because of the value when 2R is measured
by the method in the left figure if the tubing is bent or flattened, etc.

Precautions
How to Order
Be sure to read before handling.
Refer to front matter 56 for Safety
Instructions and pages 13 to 16 for
T0425 B 20
Fittings and Tubing Precautions. Length per roll
Tubing model Symbol Length
Caution Color 20 20 m roll
1. Applicable for general industrial water. Symbol Color 100 100 m roll (Black and white only)
Please consult with SMC if using other B Black (Translucent)
kinds of fluid. Surge pressure must be un- W White (Material color)
der the max. operating pressure. If the
surge pressure exceeds the maximum op- R Red (Translucent)
erating pressure, it will result in damage BU Blue (Translucent)
to fittings and tubes. Y Yellow (Translucent)
2. Please exercise caution when using this G Green (Translucent)
item in a clean room. There is a possibility
of plasticizer and other materials precipi-
tating on the tube surface and detracting
from the cleanliness level of the room.
A 410
Nylon Tubing Series T/TIA

Made to Order
(Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.)
100 m reel Metric size and Inch size except ø16: Suffix “-X3” to the end of part number. Ex.) T0425R-100-X3
Longer length reel Metric size: Suffix “-X3” to the end of part number. Ex.) T0425G-500-X3
20 m roll Inch size: Suffix “-X4” to the end of part number. Ex.) TIA01BU-20-X4
Reinforced corrugated
cardboard specification ø6, Black and White only: Suffix “-X64” to the end of part number. Ex.) T0604B-500-X64
KQ2
longer length reel
Made to Order Availability KQB2
Part no. Length Model T0425 ∗ T0604 ∗ T0806 ∗ T1075 ∗ T1209 ∗ TIA01 ∗ TIA05 ∗ TIA07 ∗ TIA11 ∗ TIA13 ∗ Color KS
100 m reel KX
Black, White,
150 m reel
X3
200 m reel
Red, Blue, KM
Yellow, Green
500 m reel
X4 20 m roll Red, Blue, Yellow, Green KF
250 m reel
X64 Black, White
500 m reel M
H/DL
L/LL

KC
KK
KK130
DM
KDM
KB
KR
KA
KQG2
KG
KFG2
MS
KKA
KP
LQ
MQR
T

410-1 B
Soft Nylon Tubing

Series TS/TISA
RoHS
KQ2
For general pneumatic tubing Model  — 20 m roll  — 100 m roll (TS1612 is reel.) KQB2
Pliable soft nylon tubing Tubing size
Metric size (Series TS) Inch size (Series TISA) KS
Max. Operating Pressure Model TS0425 TS0604 TS0806 TS1075 TS1209 TS1612 TISA01 TISA05 TISA07 TISA11 TISA13 KX
Tubing O.D. (mm) 4 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7
2.2
2.0
TS0425 Tubing I.D. (mm) 2.5 4 6 7.5 9 12 2.18 3.48 4.57 6.99 9.56 KM
Max. operating pressure MPa

1.8 TS0604 Black (B)


1.6
1.4
White (W) KF
1.2 Red (R)
1.0
0.8
Other than
TS0425, TS0604 Blue (BU) M
0.6 Yellow (Y)
H/DL
0.4 Green (G)
0.2
L/LL
0.0 Nominal size (inch)
−40 −20 0 20 40 60
Operating temperature °C
80 100 5 32 " 5 16 " 18 " 3 16 " 14" 38" 12 " KC
Nominal
size (mm)
Precautions Specifications 3.2 KK
Fluid Air/Water Note 1)
Be sure to read before handling. Refer Max. 20°C or less 2.0 1.7 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 KK130
operating 40°C 1.4 1.2 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9
to front matter 56 for Safety Instruc- pressure 60°C 1.0 0.85 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65
tions and pages 13 to 16 for Fittings MPa 80°C 0.8 0.65 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 DM
and Tubing Precautions. Note 2) 100°C 0.6 0.45 0.35 0.35 0.35 0.4 0.35 0.35 0.35 0.35 0.35
Applicable fittings Note 2) 3) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
KDM
Caution Min. bending Min. bending radius
radius mm Note 4) Bending value (Reference)
15
12
23
17
45
34
55
42
65
50
90
70
18
12
27
15
30
23
55
42
65
50
1. Compatible with water due to a change in
materials. Compatible fluid types are
Operating temperature Note 2) −40 to +100°C, Water: 0 to +50°C (No freezing) KB
Material Nylon 12
printed on the tube body for differentiation,
so please be sure to check this. Note) If
Note 1) Refer to the “Printing/Fluid”.
Note 2) Be sure to operate under the maximum operating pressure and operating temperature conditions using the lower KR
using the previous TS/TISA series with specifications of either the tubing or fittings.
Note 3) Mount an inner sleeve when using metal One-touch fittings in high-temperature environments of 60°C or more. Use
“water”, the tube may shrink and cause air
leakage or the tube may fall out.
self-align fittings at a temperature of 60°C or less.
Note 4) The minimum bending radius is the representative value measured as shown in the left figure. KA
2. The products which changed the material are • Use a tube above the minimum bending radius.
• The tubing may be bent if used under the minimum bending radius. Therefore, refer to the bending value and make
applicable for general industrial water. Please
contact SMC if using other kinds of fluid.
sure that the tubing is not bent or flattened.
• Please note that the bending value is not warranted because of the representative value when 2R is measured by KQG2
the method in the left figure if the tubing is bent or flattened, etc.
Surge pressure must be under the max.
operating pressure. If the surge pressure Printing/Fluid KG
exceeds the maximum operating pressure, it
will result in damage to fittings and tubes. Print code Fluid
3. Please exercise caution when using this Previous SMC TS 0604 SOFTNYLON 6 x 4 Air KFG2
item in a clean room. There is a possibility of NEW  SMC TS 0604 SOFTNYLON 6 x 4 Air/Water
plasticizer and other materials precipitating MS
on the tube surface and detracting from the How to Order
cleanliness level of the room.
How to measure the minimum bending radius Length per roll Color KKA
2R
At a temperature of 20°C, bend the tub-
TS0604 W 100 Symbol Length Symbol Color
ing into a U shape. Fix one end and
20 20 m roll B Black (Translucent) KP
Fixed end

gradually move the other end closer. 100 100 m roll (Black and white only) W White (Material color)
Tubing model
Measure 2R at the point where the out- R Red (Translucent) LQ
side diameter's rate of change is 10%. BU Blue (Translucent)
Y Yellow (Translucent)
G Green (Translucent) MQR
Made to Order
(Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.) T
100 m reel Metric size and Inch size except ø16: Suffix “-X3” to the end of part number. Ex.) TS0425R-100-X3
Longer length reel Metric size: Suffix “-X3” to the end of part number. Ex.) TS0425G-500-X3
20 m roll Inch size: Suffix “-X4” to the end of part number. Ex.) TISA01BU-20-X4
Made to Order Availability
Part no. Length Model TS0425 ∗ TS0604 ∗ TS0806 ∗ TS1075 ∗ TS1209 ∗ TISA01 ∗ TISA05 ∗ TISA07 ∗ TISA11 ∗ TISA13 ∗ Color
100 m reel
Black, White,
150 m reel
X3 Red, Blue,
200 m reel
Yellow, Green
500 m reel
X4 20 m roll Red, Blue, Yellow, Green

411 A
Polyurethane Tubing

Series TU/TIUB
RoHS

 — 20 m roll  — 100 m roll


For general pneumatic tubing Model/Specifications — Option — Manufactured upon receipt of order (Please consult with SMC.)
Flexible Tubing size
Polyurethane tubing Metric size (Series TU) Inch size (Series TIUB)
Model TU0212 TU0425 TU0604 TU0805 TU1065 TU1208 TU1610 TIUB01 TIUB05 TIUB07 TIUB11 TIUB13
Additional 21 new colors.
Tubing O.D. (mm) 2 4 6 8 10 12 16 3.18 4.76 6.35 9.53 12.7
Burst Pressure Characteristics Tubing I.D. (mm) 1.2 2.5 4 5 6.5 8 10 2 3.18 4.23 6.35 8.46
Curve and Operating Pressure Black (B)
White (W)
Red (R)
Blue (BU)
Burst pressure (MPa)

Yellow (Y)
Bu
rst Green (G)
pre
ss
ure Clear (C)
Orange (YR)
Solid blue (BU1)
Max. op
erating Clear blue (BU2)
pr essure
Medium blue (BU3)
Brown (BR1)

Operating temperature (°C) Solid green (G1)


Clear green (G2)
Neon green (G3)
Precautions Dark green (G4)
Gray (GR1)
Be sure to read before handling. Light gray (GR2)
Refer to front matter 56 for Safety Neon pink (P1)
Instructions and pages 13 to 16 for
Solid purple (PU1)
Fittings and Tubing Precautions.
Clear purple (PU2)

Caution Solid red (R1)


1. Applicable for general industrial water. Clear red (R2)
Please consult with SMC if using for the Silver (S1)
other kind of fluid. Also, the surge voltage
pressure must be under the maximum Solid yellow (Y1)
operating pressure. If the surge pressure Clear yellow (Y2)
exceeds the maximum operating pressure,
it will result in damage to fittings and tubes. Neon yellow (Y3)
2. The value of the max. operating pressure is Clear orange (YR1)
at a temperature of 20°C. Refer to the
burst pressure characteristics curve for Neon orange (YR2)
other temperatures. Furthermore, abnor-
mal temperature rises caused by adiabatic Nominal size (inch)
compression may result in the burst of the 5 32 " 5 16 " 18" 3 16 " 14" 38" 12"
tube.
3. The value of the minimum bending radius Nominal
is measured at the temperature of 20°C as size (mm)
shown in the figure below. 3.2

Fluid Air/Water
Max. operating
Bend the tube into U-form pressure at 20°C 0.8 MPa
at a temperature of 20°C.
Fix one end and close Burst pressure Refer to the burst pressure characteristics curve.
Fixed end

loop gradually. Measure Applicable fittings One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
2R when the tube breaks
Min. bending
or is crushed. 4 10 15 20 27 35 45 10 15 23 27 35
radius (mm)
Operating temperature –20 to +60°C (Water: 0 to 40°C) (No freezing)
Material Polyurethane

412
Polyurethane Tubing Series TU/TIUB

How to Order

TU0425 BU 20
Length per roll
Tubing model Symbol Length
20 20 m roll KQ2
100 100 m roll
Color KQB2
Symbol Color Symbol Color KS
B Black GR1 Gray KX
W White GR2 Light gray
R Red P1 Neon pink KM
BU Blue PU1 Solid purple
Y
G
Yellow
Green
PU2
R1
Clear purple
Solid red
KF
C Clear R2 Clear red
YR Orange S1 Silver M
BU1 Solid blue Y1 Solid yellow
H/DL
BU2 Clear blue Y2 Clear yellow L/LL
BU3 Medium blue Y3 Neon yellow
BR1 Brown YR1 Clear orange KC
G1 Solid green YR2 Neon orange
G2 Clear green
G3 Neon green
KK
G4 Dark green
KK130
DM

Made to Order KDM


(Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.)
KB
100 m reel Metric size and Inch size: Suffix “-X3” to the end of part number. Ex.) TU0425R-100-X3
Longer length reel Metric size: Suffix “-X3” to the end of part number. Ex.) TU0425G-500-X3 KR
20 m roll Inch size: Suffix “-X4” to the end of part number. Ex.) TIUB07W-20-X4
KA
Made to Order Availability
Part no. Length Model TU0425 ∗ TU0604 ∗ TU0805 ∗ TU1065 ∗ TU1208 ∗ TIUB01 ∗ TIUB05 ∗ TIUB07 ∗ TIUB11 ∗ TIUB13 ∗ Color KQG2
100 m reel
Black, White, Red,
X3
200 m reel
Blue, Yellow, Green,
KG
400 m reel
Clear, Orange
500 m reel KFG2
X4 20 m roll Red, White, Yellow, Green, Clear, Orange

MS
KKA
KP
LQ
MQR
T

413
Soft Polyurethane Tubing

Series TUS
RoHS
Suitable for piping in Model/Specifications  — 20 m roll  — 100 m reel
confined spaces Model TUS0425 TUS0604 TUS0805 TUS1065 TUS1208
Extremely flexible Tubing O.D. (mm) 4 6 8 10 12

Soft polyurethane tubing Tubing I.D. (mm) 2.5 4 5 6.5 8


Black (B)
TUS related accessories White (W)
Inner sleeve
Red (R)
Series TJ
Reinforces soft polyuretharane tubing. Blue (BU)
Insert an inner sleeve into soft Yellow (Y)
polyurethane tubing when used with a
One-touch fitting. Green (G)
Translucent (N) (1)
Yellow brown (YB)
Soft polyurethane
tubing

Iner sleeve Fluid Air


Max. operating pressure at 20°C 0.6 MPa
Burst pressure Refer to the burst pressure characteristics curve.
Applicable fittings One-touch fitting, Insert tube fitting, Hose nipple (3)
One-touch fitting
Min. bending radius (mm) (2) 8 15 15 22 29
Model Operating temperature –20 to +60°C (No freezing)
Model Applicable tubing model Length Material Polyurethane
Tube drawing Without
TJ-0425 TUS0425 18 inner sleeve 15 60 60 85 110
strength (N) With
TJ-0604 TUS0604 19 (Using One-touch fitting) inner sleeve 80 230 250 300 480
TJ-0805 TUS0805 20.5 Note 1) Not clear, but translucent due to material.
TJ-1065 TUS1065 23 Note 2) Min. bending radius is measured as shown in the figure below.
TJ-1208 TUS1208 24
Burst Pressure Characteristics
Specifications Bend the tube into U-form at Curve and Operating Pressure
a temperature of 20°C. Fix
Material C2700T (Electroless nickel plated) one end and close loop
Fixed end

Burst pressure (MPa)

Wall thickness 0.2 mm gradually. Measure 2R when


the tube breaks or is crushed. Burs
t pres
sure
Precautions
Maximum operating pressure
Be sure to read before handling. Note 3) Always use inner sleeve (Series TJ) in
Refer to front matter 56 for Safety safety circuit or critical area.
Instructions and pages 13 to 16 for
Operating temperature (°C)
Fittings and Tubing Precautions.

Caution How to Order


1. Use a nylon or polyurethane tubing for
general industrial water, otherwise the tube
may result in being fallen out or bursted TUS1065 B 100
when the max. operating pressure is lower
and the surge pressure is occurred. Length per roll
2. The value of the max. operating pressure Tubing model Symbol Length
is at a temperature of 20°C. Refer to the Color
burst pressure characteristics curve for 20 20 m roll
other temperatures. Furthermore, abnor- Symbol Color 100 100 m reel (Black, Blue only)
mal temperature rises caused by adiabatic B Black
compression may result in the burst of the W White
tube. R Red
3. The value of the minimum bending radius BU Blue
is measured at the temperature of 20°C as
Y Yellow
shown in the figure on the right.
4. Use inner sleeve, taking the removing G Green
force into consideration when used with N Translucent
One-touch fittings. YB Yellow brown

414
Hard Polyurethane Tubing/Standard Type

Series TUH RoHS

KQ2
Model/Specifications  — 20 m roll  — 100 m roll KQB2
Model TUH0428 TUH0644 TUH0858 TUH1073 TUH1288 KS
O.D. (mm) 4 6 8 10 12
KX

I.D. (mm) 2.8 4.4 5.8 7.3 8.8 KM


Black (B) KF
Bend the tube into U-form White (W)
at a temperature of 20°C. Blue (BU) M
Fixed end

Fix one end and close


loop gradually. Measure Translucent (N) H/DL
2R when the tube breaks L/LL
or is crushed.
KC
Fluid Air
Burst Pressure Characteristics KK
Max operating
Curve and Operating Pressure pressure (at 20°C)
0.8 MPa
KK130
Applicable fittings One-touch fittings

5 Min. bending radius (mm) 10 18 24 30 36 DM


Burst pressure Refer to the burst pressure characteristics curve.
KDM
4
Burst pressure (MPa)

Br
us Operating temperature –20 to 60°C
tp
re
ss Material Polyurethane KB
3 ur
e
KR
2
How to Order
KA
1

0
Maximum operating pressure
TUH0644 B 20 KQG2
-20 0 20 40 60 KG
Operating temperature (°C)
Length per roll
Tubing model
Symbol Length KFG2
20 20 m roll
Precautions 100 100 m roll MS
Be sure to read before handling. Color KKA
Refer to front matter 56 for Safety Symbol Color
Instructions and pages 13 to 16 for B Black KP
Fittings and Tubing Precautions. W White
BU Blue
LQ
Caution N Translucent

1. Please consult with SMC regarding other MQR


fluids. Because ester polyurethane is used,
water cannot be used due to the occur-
rence of hydrolysis. T
2. The value of the max. operating pressure
is at a temperature of 20°C. Refer to the
burst pressure characteristics curve for
other temperatures. Furthermore, abnor-
mal temperature rises caused by adiabatic
compression may result in the burst of the
tube.
3. The value of the minimum bending radius
is measured at the temperature of 20°C as
shown in the figure above.

415
Hard Polyurethane Tubing/High Pressure Type

Series TUH RoHS

Model/Specifications  — 20 m roll  — 100 m roll


Model TUH0425 TUH0604 TUH0805 TUH1065 TUH1208
O.D. (mm) 4 6 8 10 12
I.D. (mm) 2.5 4 5 6.5 8
Bend the tube into U-form
at a temperature of 20°C.
Black (B)
Fixed end

Fix one end and close


loop gradually. Measure
White (W)
2R when the tube breaks
or is crushed. Blue (BU)
Translucent (N)
Burst Pressure Characteristics
Curve and Operating Pressure
Fluid Air
7
Max operating
pressure (at 20°C) 1.0 MPa
6
Applicable fittings One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
Br
us

Min. bending radius (mm) 10 15 20 27 35


tp
Burst pressure (MPa)

5
res

Burst pressure
su

Refer to the burst pressure characteristics curve.


re

4 Operating temperature –20 to 60°C


Material Polyurethane
3

2 How to Order
Maximum operating pressure

TUH0604 B 20
1

0
-20 0 20 40 60
Operating temperature (°C) Length per roll
Tubing model
Symbol Length
20 20 m roll

Precautions 100 100 m roll

Color
Be sure to read before handling. Symbol Color
Refer to front matter 56 for Safety B Black
Instructions and pages 13 to 16 for W White
Fittings and Tubing Precautions. BU Blue
N Translucent
Caution
1. Please consult with SMC regarding other
fluids. Because ester polyurethane is used,
water cannot be used due to the occur-
rence of hydrolysis.
2. The value of the max. operating pressure
is at a temperature of 20°C. Refer to the
burst pressure characteristics curve for
other temperatures. Furthermore, abnor-
mal temperature rises caused by adiabatic
compression may result in the burst of the
tube.
3. The value of the minimum bending radius
is measured at the temperature of 20°C as
shown in the figure above.

416
Wear Resistant Tubing
Series TUZ

1/
RoHS
KQ2
KQB2

3
Maximum abrasion (mm)
Description
After 10 million cycles KS
KX
Abrasion: Approx. Wear resistant tubing
TUZ series 0.16
KM
(Compared with SMC polyurethane tubing TU series) Polyurethane tubing
0.46
TU series
KF
Note) Comparison based on the SMC's
specific testing condition
M
H/DL
L/LL

KC
KK
KK130
DM
KDM
KB
KR
KA
KQG2
KG
KFG2
MS
KKA
KP
LQ
6-color variations MQR
T
Black White Red Blue Yellow Green

8-size variations

Tubing O.D.: ø2 ø3.2 ø4 ø6 ø8 ø10 ø12 ø16


417 A
Wear Resistant Tubing RoHS

Series TUZ
Model  — 20 m roll  — 100 m roll
Model TUZ0212 TUZ3220 TUZ0425 TUZ0604 TUZ0805 TUZ1065 TUZ1208 TUZ1610
Tubing O.D. (mm) 2 3.2 4 6 8 10 12 16
Tubing I.D. (mm) 1.2 2 2.5 4 5 6.5 8 10

Black (B)
White (W)
Red (R)
Blue (BU)
Yellow (Y)
Green (G)

Specifications
Fluid Air/Water
One-touch fittings KQ2 series,
Applicable fittings Insert fittings KF series, Stainless steel 316 insert fittings KFG2 series,
Miniature fittings M/MS series (hose nipple type)
Max. operating 20°C 0.8 MPa
pressure 60°C 0.4 MPa
Burst pressure Refer to the burst pressure characteristics curve.
Min. bending radius (mm) 4 10 10 15 20 27 35 45
Operating temperature –20 to +60°C (Water: 0 to 40°C) (No freezing)
Material Special polyurethane
Note 1) The minimum bending radius means the value measured by the method shown in the figure at the right at the temperature of 20°C when the tube is bent. The minimum
bending radius assumes static piping. If the tube is used in a moving part, provide extra length to the tube. Check the bending radius recommended by the flexible
protection tube manufacturer for sure if the tube is used in the flexible protection tube.
Note 2) Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure. If the surge
pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubes.

Burst Pressure Characteristics Curve and Operating Pressure How to Calculate Minimum Bending Radius
4.0

2R
3.0
Fixed end
Pressure (MPa)

Burst pressure

2.0

1.0

Maximum operating pressure


Bend the tube into U-form at the
0
–20 0 20 40 60 temperature of 20°C. Fix one end
and close loop gradually. Measure
Temperature (°C) 2R when the tube breaks or is
crushed.

How to Order

TUZ0425 BU 20
Tubing model Color Length per roll
Model O.D. x I.D. (mm) Symbol Color Symbol Length
TUZ0212 2 x 1.2 B Black 20 20 m roll
TUZ3220 3.2 x 2 W White 100 100 m roll
TUZ0425 4 x 2.5 R Red
TUZ0604 6x4 BU Blue
TUZ0805 8x5 Y Yellow
TUZ1065 10 x 6.5 G Green
TUZ1208 12 x 8 Note) Not clear, but translucent due to material.
TUZ1610 16 x 10
A 418
Wear Resistant Tubing Series TUZ

Reference Data: Abrasion due to Flexible Protection Tube


Test Conditions
Test tube TUZ0604, TU0604 L
Quantity of tube tested 5 pcs. for each
Operating speed 1500 mm/sec Flexible protection tube
Operating frequency 90 c.p.m R
KQ2
Stroke L 500 mm
Bending radius R 28 mm KQB2
Material of flexible protection tube Special engineering plastic KS
Tube tie Not used KX

KM
Test Results Flexible protection tube
Tube
Model Maximum abrasion after 10 million cycles (mm) KF
TUZ0604 0.16
TU0604 0.46 M

10.5
As this test was an acceleration test, the tube bending radius was out of the flexible
protection tube manufacturer's allowable range. H/DL
When the flexible protection tube is used in the actual application, check the L/LL
manufacturer’s catalog specifications.
The values in the table above are representative values, and not guaranteed.
64 KC
Tube dimensions inside the flexible protection tube KK
KK130
Made to Order TFU-X73 DM
Wear Resistant Flat Tubing: Multi-core, same color specification KDM
Flat type of the TUZ series
The identification line is not shown.
Please contact SMC for detailed specifications, dimensions, and delivery.
KB
How to Order KR
TFU0425 BU 2 20 X73 KA
Color Special polyurethane KQG2
Symbol Color (Multi-core, same color specification)
B Black KG
W White Length per roll
R Red
BU Blue
Nil
n
10 m
n m Note)
KFG2
Y Yellow Note) It is also available in lengths other than 10 m.
G Green Enter the length you need (1, 2, 3, 4, 5, 20). MS
Note) Not clear, but Example) TFU0425BU-2-20-X73
translucent due
to material. Number of cores
KKA
20 m
2 to 12
Tubing model
KP
Model O.D. x I.D. (mm)
TFU0425 4 x 2.5
LQ
TFU0604 6x4
TFU0805 8x5 MQR
TFU1065 10 x 6.5
TFU1208 12 x 8 T

419 A
Series TUZ
Specific Product Precautions
Be sure to read before handling.
Refer to front matter 56 for Safety Instructions,
pages 13 to 16 for Fittings and Tubing Precautions.

Selection Piping

Warning Caution
1. Confirm the specifications. 1. Preparation before piping
Products represented in this catalog are designed only for use Before piping is connected, it should be thoroughly blown out
with compressed air system applications (including vacuum). with air (flushing) or washed to remove chips, cutting oil and
Do not use at pressure or temperature beyond the range of other debris from inside the pipe. Not allowing chips of the
specifications, as this can cause damage or malfunction. piping thread or the seal material to go in.
(Refer to the specifications.) The minimum bending radius assumes static piping. If the
tube is used in a moving part, provide extra length to the tube.
2. In case of using the product for medical care Check the bending radius recommended by the flexible
This product is designed for use with compressed air system protection tube manufacturer for sure if the tube is used in the
applications for medical care purposes. Do not use in transfer flexible protection tube.
applications to a human living body, or in contact with human
bodily fluids, body tissues.
Air Supply
Caution
1. Do not use in locations where the connecting
Warning
threads and tube connection will slide or rotate. 1. Types of fluid
The connecting threads and tube connection will come apart This product is designed for use with compressed air.
under these conditions. 2. In case of excessive condensation
Use rotary type one-touch fittings (KS, KX series) in cases Excessive condensation in compressed air may cause
where sliding or rotation will occur. malfunction of pneumatic devices. Installation of an air dryer,
2. Use the tube at or above the minimum bending water separator before filter is recommended.
radius. Using below the minimum bending radius 3. Drain flushing
can cause breakage or flattening of the tube. If condensation in the drain bowl of an air filter is not emptied
3. Never use the tube for anything flammable, explo- on a regular basis, the condensation will enter the outlet side,
sive or toxic such as gas, fuel gas, or cooling medi- causing malfunction of pneumatic devices.
If the drain flushing is difficult, installation of a filter with an
ums, etc.
auto drain option is recommended.
Because the contents may penetrate outward. For compressed air quality, refer to SMC’s “Air Preparation
4. Use the suitable fittings for the tube size. Equipment Model Selection Guide.”

Mounting Operating Environment

Caution Warning
1. Confirm model number, size, etc. before installing. 1. Do not use in locations having an explosive atmo-
Check if there is damage, gouge, crack, etc. on the tube. sphere.
2. When the tube is connected, consider factors such 2. Do not operate in locations where vibration or im-
as changes in the tubing length due to pressure, pact occurs.
and allow sufficient leeway. 3. In locations near heat sources, block off radiated
3. Do not apply unnecessary forces such as twisting, heat.
pulling, moment loads, etc. on fittings and tube.
This will cause damage to fittings or flattening, bursting or Maintenance
disconnection of tube, etc.
4. Mount so that tube is not damaged due to tangling.
This will cause flattening, bursting or disconnection of tube,
Caution
etc. 1. Perform periodic inspections to check the following
problems and replace the tube, if necessary.
a) Cracks, gouges, wearing, corrosion
b) Air leakage
c) Twists or crushing of tube
d) Hardening, deterioration, softening of tube
2. Do not repair or patch the replaced tube or fittings
for reuse.

420
Polyurethane Coil Tubing

Series TCU RoHS

KQ2
For flexible tubing Model/Specifications KQB2
Compact piping possible Model
TCU TCU TCU TCU TCU TCU TCU
0425B-1 0425B-2 0425B-3 0604B-1 0604B-2 0604B-3 0805B-1 KS
Burst Pressure Characteristics Number of cores 1 core 2 cores 3 cores 1 core 2 cores 3 cores 1 core KX
Curve and Operating Pressure Tubing O.D. (mm) 4 6 8
Tubing I.D. (mm) 2.5 4 5
KM
Fluid Air
Max. operating pressure (at 20°C) 0.8 MPa KF
Applicable fittings One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
Burst pressure (MPa)

Bu
rst
Burst pressure Refer to the burst pressure characteristics curve. M
pre Operating temperature –20 to +60°C
ss
ure Material Polyurethane H/DL
Color Black L/LL

KC
Maximum op
erating press
ure
Dimensions
KK
(Maximum operating length)
KK130
Operating temperature (°C)
DM
Precautions KDM
Be sure to read before handling. Tube fastener (Multi-tube only) KB
Refer to front matter 56 for Safety
Instructions and pages 13 to 16 for Specifications Tubing size (mm) Coil (mm) No. of No. of coil windings Max. operating Standard unit
KR
Model O.D. I.D. L øD cores per tube length length (m) of packing
Fittings and Tubing Precautions.
TCU0425B-1 210 18 1 52 ± 2
TCU0425B-2 4 2.5 280 2 35 ± 1
1.5
KA
Caution TCU0425B-3 265
28
3 22 ± 1 1
1. Please consult with SMC regarding use
with any fluids other than air.
TCU0604B-1
325
24 1 54 ± 2 2 5 tubes/case KQG2
TCU0604B-2 6 4 2 27 ± 1 1.5
2. Refer to the burst pressure characteristics 37
17 ± 1
curve for other temperatures.
TCU0604B-3
TCU0805B-1 8 5
305
330 31
3
1 41 ± 2
1
2
KG
Furthermore, abnormal temperature rises
∗ The number of coil windings per tube length and dimensions are changeable due to material.
caused by adiabatic compression may
result in the burst of the tube.
KFG2
3. Please do not cut the coil and insert it into
the fitting. This may cause air leakage, or MS
tubing to come out after installation.
Made to Order KKA
Change of coil turns, Change of color (Please contact SMC for specifications in detail, dimensions and delivery.)
KP
(Maximum operating length)

LQ
MQR
T
Tube fastener (Multi-tube only)

Specifications Tubing size (mm) Coil (mm) No. of No. of coil Max. operating Specifications Tubing size (mm) Coil (mm) No. of coil Max. operating
No. of windings
windings per per
Model O.D. I.D. L øD cores tube length (N) length (mm) Model O.D. I.D. L øD cores tube length (N) length (mm)
TCU0425 -1-N-X6 N x 4 18 1 3 to 90 L x 5.9 + 200 TCU0805 -1-N-X6 Nx8 31 1 3 to 90 L x 5.2 + 200
8 5
TCU0425 -2-N-X6 4 2.5 N x 8 28 2 3 to 90 L x 4.4 + 200 TCU0805 -2-N-X6 N x 16 42 2 3 to 40 L x 3 + 200
TCU0425 -3-N-X6 N x 12 28 3 3 to 63 L x 2.9 + 200 TCU1065 -1-N-X6 N x 10 52 1 3 to 45 L x 5 + 200
10 6.5
TCU0604 -1-N-X6 N x 6 24 1 3 to 90 L x 5.3 + 200 TCU1065 -2-N-X6 N x 20 52 2 3 to 35 L x 3 + 200
TCU0604 -2-N-X6 6 4 N x 12 37 2 3 to 66 L x 3.8 + 200 TCU1208 -1-N-X6 N x 12 67 1 3 to 35 L x 5 + 200
12 8
TCU0604 -3-N-X6 N x 18 37 3 3 to 44 L x 2.5 + 200 TCU1208 -2-N-X6 N x 24 67 2 3 to 30 L x 3 + 200
∗ : B (Black), W (White), R (Red), BU (Blue), Y (Yellow), G (Green), C (Clear), YR (Orange)
421 A
Polyurethane Flat Tubing

Series TFU
RoHS

Compact piping possible Model/Specifications


With line markings for Model
TFU TFU TFU TFU TFU TFU
piping differentiation 0425B-2 0425B-3 0604B-2 0604B-3 0805B-2 0805B-3
No. of cores 2 cores 3 cores 2 cores 3 cores 2 cores 3 cores
Burst Pressure Characteristics Tubing O.D. (mm) 4 6 8
Curve and Operating Pressure Tubing I.D. (mm) 2.5 4 5
Fluid Air
Max. operating pressure (at 20°C) 0.8 MPa
Burst pressure Refer to the burst pressure characteristics curve.
Applicable fittings One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings
Operating temperature –20 to +60°C (No freezing)
Burst pressure (MPa)

Bu Material Polyurethane
rst
pre Color Black
ssu
re Min. bending radius (mm) 10 15 20
Tube length per roll (m) 10

Maximum op
erating pre
ssure

How to Order
Operating temperature (°C)
TFU0425 B 2
Precautions Tubing model
No. of tubes
Symbol No. of cores
Be sure to read before handling. Color 2 2 cores
Refer to front matter 56 for Safety Symbol Color 3 3 cores
Instructions and pages 13 to 16 for B Black
Fittings and Tubing Precautions.

Caution
1. Please consult with SMC regarding use
with any fluids other than air.
2. Refer to the burst pressure characteristics
curve for other temperatures.
Furthermore, abnormal temperature rises
caused by adiabatic compression may re- Bend the tube into U-form
sult in the burst of the tube. at a temperature of 20°C.
Fixed end

3. The value of the minimum bending radius Fix one end and close
is measured at the temperature of 20°C as loop gradually. Measure
shown in the figure on the right. 2R when the tube breaks
4. As a result of product design characteris- or is crushed.
tics, there are cases of very slight leakage.

Made to Order
(Please contact SMC for specifications in detail, dimensions and delivery.)
 —10 m roll  — 50 m reel  — 100 m reel

1. Change of color (10 m roll) Model TFU0425 TFU0604 TFU0805 TFU1065 TFU1208
Suffix “-X4” to the end of part number. Tubing O.D. (mm) 4 6 8 10 12
Ex.) TFU0604BU-2-10- X4 Tubing I.D. (mm) 2.5 4 5 6.5 8
• W: White, R: Red, BU: Blue, Y: Yellow, G:
Green, C: Clear, YR: Orange, (All tubes are the 2
same color regardless of 2 cores or 3 cores.)
3
2. Reel (50 m, 100 m length, Color changes) 4
Suffix “-X3” to the end of part number. No. of
cores 5
Ex.) TFU0425B-2-50- X3
6
3. No. of cores (10 m roll, each color)
7
Suffix “-X4” to the end of part number.
8
Ex.) TFU0604B-4-10- X4
422
Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Soft Nylon Tubing

Series TRS
RoHS
KQ2
KQB2
Suitable for air and water Model/Specifications  — 20 m roll  — 100 m reel
KS
piping in environments where Model TRS0603 TRS0805 TRS1065 TRS1208 KX
sparks from spot welders, etc., Tubing O.D. (mm) 6 8 10 12

may be a problem. Tubing I.D. (mm) 3 5 6.5 8 KM


Black (B)
Flame resistant tubing KF
White (W)
Burst Pressure Characteristics Red (R) M
Curve and Operating Pressure Blue (BU) H/DL
Green (G) L/LL

KC
Burst pressure (MPa)

Oth
er t
han Fluid Air/Water KK
TS Max. operating pressure (at 20°C) 1.2 MPa
R0
603
Burst pressure Refer to the burst pressure characteristics curve. KK130
Maximum operating pressure Applicable fittings FR one-touch fittings: Series KR-W2
Minimum bending radius DM
17 19 27 32
(mm)
Operating temperature (°C) Operating temperature –20 to +60°C (Water: 0 to 60°C) (No freezing) KDM
Material Flame resistant nylon (Equivalent to UL-94 standard V-0)
KB
Precautions KR
How to Order
Be sure to read before handling. KA
Refer to front matter 56 for Safety
Instructions and pages 13 to 16 for
Fittings and Tubing Precautions.
TRS1065 B 100 KQG2
KG
Caution Tubing model Length per roll
1. Applicable for general industrial water. Symbol Length KFG2
Please consult with SMC if using for the 20 20 m roll
other kind of fluid. 100 100 m reel
Also, the surge voltage pressure must be MS
under the maximum operating pressure.
Color
If the surge pressure exceeds the maxi-
mum operating pressure, it will result in Symbol Color
KKA
damage to fittings and tubes. B Black
2. The value of the max. operating pressure W White KP
is at a temperature of 20°C. Refer to the R Red
burst pressure characteristics curve for BU Blue LQ
other temperatures. G Green
Furthermore, abnormal temperature rises
caused by adiabatic compression may re- MQR
sult in the burst of the tube.
T

423
Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Double Layer Tubing

Series TRB RoHS

Suitable for air and water Model  — 20 m roll  — 100 m reel


piping in environments where
sparks from spot welders, Model TRB0604 TRB0806 TRB1075 TRB1209
etc., may be a problem. Inner tubing O.D. (mm) 6 8 10 12
Inner tubing I.D. (mm) 4 6 7.5 9
Double layer design using Outer layer thickness (mm) 1 1 1 1
flame resistant resin Note)
Black (B)
(equivalent to UL-94 Standard
External layer color

White (W)
V-0) for outer layer.
Red (R)
Blue (BU)
Yellow (Y)
Green (G)

Min. bending radius


15 28 35 45
(mm)

Specifications
Fluid Air/Water
Inner tubing Max. operating pressure
1.0 MPa
(at 20°C)
Burst pressure Refer to the burst pressure characteristics curve.
Outer layer Recommended fittings FR One-touch fittings: Series KR-W2
–20 to +60°C
Ambient and fluid temperature
(Water: 0 to 60°C) (No freezing)
Inner tubing Nylon 12
Sectional view of FR double layer tubing
Material
Outer layer PVC (Equivalent to UL-94 Standard V-0)
Note) The color of all inner tubing is black.

Burst Pressure Characteristics


Curve and Operating Pressure How to Order

TRB1075 B 100
Bu
rs
tp
re
ss
Tubing model Color Length per roll
Burst pressure (MPa)

Bu ur
rst eT
pre RB Symbol Color Symbol Color Symbol Length
ssu 06
re 04 B Black BU Blue 20 20 m roll
(Fo
ro W White Y Yellow 100 100 m reel
the
r th
an R Red G Green
TR
B0
60
4)
Maximum operatingpressure
(TRB0604)

Maximum operating pressure


(For other than TRB0604)

Operating temperature (°C)

424
FR Double Layer Tubing Series TRB

Installation on One-touch Fittings

Caution
Length of tubing to be inserted into One-touch fittings is indicat-
ed on the outer layer of TRB tubing. Cut the tube according to
this indication, (Step 1) and then strip off the outer layer (Step 2)
for installing into fittings.
KQ2
KQB2
KS
KX

KM
Pitch indication: All installation lengths with same pitch
KF

Step 1
M
H/DL
L/LL

KC
Cut internal and external layers
KK
Step 2 KK130
DM
KDM
Strip off external layer only
KB
KR
Precautions KA

Be sure to read before handling. KQG2


Refer to front matter 56 for Safety Instructions and pages 13 to 16 for Fittings and Tubing Precautions.
KG
Caution KFG2
1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Also, the surge voltage pressure must be
under the maximum operating pressure.
If the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings and tubing. MS
2. The value of the max. operating pressure is at a temperature of 20°C. Refer to the burst pressure characteristics curve for other temperatures.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. KKA
KP
LQ
MQR
T

425
Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Double Layer Polyurethane Tubing

Series TRBU RoHS

Model  — 20 m roll  — 100 m reel

Model TRBU0604 TRBU0805 TRBU1065 TRBU1208


Inner tubing O.D. (mm) 6 8 10 12
Inner tubing I.D. (mm) 4 5 6.5 8
External layer thickness (mm) 1 1 1 1

Note)
Black (B)
External layer color

White (W)
Inner tubing
Red (R)
Blue (BU)
Outer layer
Yellow (Y)
Green (G)

Sectional view of FR double layer tubing


Minimum bending
15 20 27 35
radius (mm)
Burst Pressure Characteristics
Curve and Operating Pressure
Specifications
5.0
Fluid Air/Water
4.0
Burst pressure (MPa)

Max. operating pressure 0.8 MPa


Bu (at 20°C)
rst
3.0 pre
ssu Burst pressure Refer to the burst pressure characteristics curve.
re
Applicable fittings FR one-touch fittings: Series KR-W2
2.0
Ambient and –20 to +60°C
Max. oper fluid temperature Water: 0 to 40°C (No freezing)
1.0 ating pres
sure
Internal tubing Polyurethane
0 Material
-20 0 20 40 60
Outer layer Polyolefin (Equivalent to UL-94 standard V-0)
Operating temperature (°C) Note) The color of all inner tubing is black.

How to Order

TRBU1065 B 100
Length per roll
Tubing model
Symbol Length
20 20 m roll
100 100 m reel

Color
Symbol Color Symbol Color
B Black BU Blue
W White Y Yellow
R Red G Green

426
FR Double Layer Polyurethane Tubing Series TRBU

Installation on One-touch Fittings

Caution
Lengths of tubes to be inserted into One-touch fittings are
indicated on the outer layer of TRBU tubes. Cut the tube accord-
ing to this indication, (Step 1) and then strip off the outer layer
(Step 2) for installing into fittings.
KQ2
KQB2
8x5 SMC FR TUBE TRBU0805 8 x 5 KS
KX

KM
Pitch indication: All installation lengths with same pitch
KF
Step 1
M
8x5 SMC FR TUBE TRBU0805 8 x 5
H/DL
L/LL

Cut internal and external layers KC


Step 2
KK
8x5 SMC FR TUBE
KK130
DM
Strip off the external layer only

KDM
KB
KR
Precautions KA

Be sure to read before handling. KQG2


Refer to front matter 56 for Safety Instructions and pages 13 to 16 for Fittings and Tubing Precautions.
KG
Caution KFG2
1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Bend the tube into U-form
Also, the surge voltage pressure must be under the maximum operating pressure. at a temperature of 20°C.
MS
Fixed end

2. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal Fix one end and close
temperature rises caused by adiabatic compression may result in the burst of the tube. loop gradually. Measure
3. The value of the minimum bending radius is measured at the temperature of 20°C as shown in 2R when the tube breaks
or is crushed.
KKA
the figure on the right.
KP
LQ
MQR
T

427
Related Products:
Double Layer Tube Stripper

Series TKS RoHS

Allows easy stripping of the Model


outer layer from double layer
tubes. Model
Tip
color
Applicable tubing ∗
Dimensions (mm) Weight
(g)
D1 D2 L
Even the double layer TKS-06 Orange TRB0604, TRBU0604 16
58 45
polyurethane tubing (Series TKS-08 Yellow TRB0806, TRBU0805
35
18
TRBU), which is highly TKS-10 Blue TRB1075, TRBU1065 20
62 50
adhesive to the external TKS-12 Green TRB1209, TRBU1208 22
∗ Inner tubing material/TRB: Nylon, TRBU: Polyurethane
layer can be stripped easily.
Dimensions

ØD2

ØD1
9.7 L
(3/8")

Able to strip without damaging the inner tubing


The outer tube can be stripped without damaging the inner tube because a pawl is
inserted between the inner and outer tube layers.
Tubing guide
Cutter
Outer layer

Inner tubing

Pawl

Can be attached to tools


Stripping work can be automated by attaching an air driver, etc. with it.

Socket adapter

Adjustment of cutter and stripping length is unnecessary


A constant stripping length is always possible due to the fixed cutter with angle that
cuts until the tube reaches the end surface inside the stripper.

Removal of stripped tube is unnecessary.


Since the stripped tube is discharged to the outside, no additional labor is required
to remove it.
Window

428
Series TKS
Specific Product Precautions
Be sure to read before handling.
Refer to front matter 56 for Safety Instructions and pages 13 to 16 for
Fittings and Tubing Precautions.

Operation Attachment to Tools

Caution Caution KQ2


1. Insert the tube into the double layer tube stripper (Series TKS). 1. Align the socket of the TKS with a commercially available
male socket adapter (9.5 mm square). KQB2
2. Connect the socket adapter to the TKS. KS
Tube KX
TKS
KM
Socket adapter KF
Hook
M
2. Rotate the TKS in the arrow direction while pushing it.
H/DL
3. Strip the outer layer until the cut end of the tubing strikes L/LL
the end surface inside the stripper.
The end surface can be confirmed in the window. KC
Note) Stripping is not possible by rotating in the opposite 3. Connection with tools such as an air driver is also possible.
direction. Note) Ensure the TKS does not shake or vibrate. KK
Window
KK130
Air driver, etc.
DM
KDM
KB
4. Pull the TKS off of the tubing to complete stripping.
The tube can be attached as it is to a FR One-touch fitting. KR
Operation
KA
Caution KQG2
1. When using a tool such as air driver, use a push-
start type which rotates after the tubing is inserted. KG
2. Do not insert the tube when the TKS is rotating, as
the pawl may be damaged. KFG2
MS
KKA
KP
LQ
MQR
T

429
FR Three-layer Polyurethane Tubing
Series TRTU
Flame Resistant (Equivalent to UL-94 Standard V-0)
RoHS
Improved spatter resistance
Spatter resistance is twice that of FR
double layer polyurethane tubing TRBU series. ∗ In SMC conditions

For general pneumatic and water


piping in environments exposed
to sparks from arc welding, etc.
Three-
Spatter resistance is improved
layer
by installing an aluminum layer design
between the outer layer and
inner tube.

Outer Flame resistant polyolefin


layer (Equivalent to UL-94 standard V-0)

Middle
layer Aluminum laminated film

Inner
tube Polyurethane

6-color variations

Black White Red Blue Yellow Green

Model  — 20 m roll  — 100 m reel


Model TRTU0604 TRTU0805 TRTU1065 TRTU1208
Inner tube O.D. (mm) 6 8 10 12
Inner tube I.D. (mm) 4 5 6.5 8
Outer layer thickness (mm) 1 1 1 1
Black (B)
Outer layer color

White (W)
Red (R)
Blue (BU)
Yellow (Y)
Green (G)

430
Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Three-layer Polyurethane Tubing

SeriesTRTU RoHS

KQ2
Model  — 20 m roll  — 100 m reel KQB2
Model TRTU0604 TRTU0805 TRTU1065 TRTU1208
Inner tube O.D. (mm) 6 8 10 12
KS
KX
Inner tube I.D. (mm) 4 5 6.5 8
Outer layer thickness (mm) 1 1 1 1 KM
Outer layer Black (B) KF
Flame resistant polyolefin Note 3) White (W)
(Equivalent to UL-94 standard V-0)
Middle layer
Outer
layer
Red (R) M
color Blue (BU)
Aluminum laminated film H/DL
Yellow (Y) L/LL
Inner tube
Green (G)
Polyurethane
KC
Specifications
Fluid Note 1) Air, Water
KK
For general pneumatic and water
FR One-touch fittings: Series KR-W2
piping in environments exposed Applicable fittings
Metal One-touch fittings: Series KQB2 KK130
to sparks from arc welding, etc.
At 20°C 0.8 MPa
Max. operating
At 40°C 0.65 MPa
DM
How to measure the pressure
At 60°C 0.5 MPa
minimum bending radius
Burst pressure Refer to the burst pressure characteristics curve.
KDM
Min. bending radius (mm) Note 2) 50 60 70 80
2R
Ambient and fluid temperature −20 to +60°C, Water: 0 to 40°C (No freezing)
KB
Fixed end

Inner tube Polyurethane


Material Middle layer Aluminum laminated film
KR
Outer layer Polyolefin (Equivalent to UL-94 standard V-0)
Note 1) Applicable for general industrial water. Please consult with SMC if using for the other kind
KA
of fluid. Also, the surge pressure must be under the maximum operating pressure.
If the surge pressure exceeds the maximum operating pressure, it will result in damage to KQG2
Bend the tube into the U-form at a temper- fittings and tubes.
ature of 20°C. Fix one end and close loop
gradually. Measure 2R when the deformed
Note 2) The minimum bending radius is the representative value measured as shown in the left
figure. Allow extra length when piping since the tube may be bent if used under the
KG
ratio of the tube diameter at bending minimum bending radius.
reaches 5%. Note 3) The color of all inner tubes is black. KFG2
MS
Burst Pressure Characteristics
Curve and Operating Pressure How to Order KKA
KP
4.0
TRTU1065 B 20 LQ
3.0
Tubing model Length per roll MQR
Pressure (MPa)

Burst pressure
Model Inner tube O.D. x I.D. (mm) Symbol Length
Color
2.0 TRTU0604 6x4
Symbol Color
20 20 m roll T
TRTU0805 8x5 100 100 m reel
TRTU1065 10 x 6.5 B Black
1.0
TRTU1208 12 x 8 W White
Max. operating pressure
R Red
0.0 BU Blue
−20 0 20 40 60 Y Yellow
Operating temperature (°C) G Green

431
Series TRTU

Installation on One-touch Fittings


Pitch length for installation on a One-touch fitting is indicated on the outer layer of the TRTU tubing.
(There are two types of applicable fittings, so two types of pitch length for installation are available.)
Cut the tube according to this indication (Step 1) and strip off the outer layer (Step 2) using a special tool.
Strip off the aluminum laminated film to prevent the inner tube from being damaged (Step 3) and install it on the One-touch fitting.
Refer to the Operation Manual for details of installation on the One-touch fitting.
The Operation Manual can be downloaded from the SMC URL below.
http://www.smcworld.com
Metal One-touch fittings
Pitch indication (Series KQB2): All installation lengths with the same pitch Series KQB2

Pitch indication (Series KR-W2): All installation lengths with the same pitch

Identification of the pitch length Flame resistant


for installation (equivalent to UL-94 standard V-0)
“ ”: Series KQB2 FR One-touch fittings
“ ”: Series KR-W2
Series KR-W2

Installation on the KR-W2 series

Step 1

Use a special tool for stripping


off the outer layer.
Part no.: YS-100
∗ Refer to the Operation Manual
for details of how to use the
special tool.

Outer layer, aluminum laminated film


and inner tube are cut at the “ ” mark.
Step 2

Tube

Special tool

Strip off the outer layer.


Step 3

Strip off the aluminum laminated film to prevent


the inner tube from being damaged.

432
2-Layer Soft Fluoropolymer Tubing
Series TQ

Carries fluid such as solvent RoHS


KQ2
with a soft and abrasion resistant tube. KQB2
KS
2-layer KX
structure Outer
layer Special nylon resin KM
KF
Inner
layer Special fluoropolymer
M
H/DL
L/LL

KC
Translucent tube helps in identifying KK
Internal smoothness the fluid color.
Equivalent to Ra 0.02 µm Peeling before piping is not necessary. KK130
DM

Improved by up to 55%∗1
TL: 40 mm
KDM
TD/Soft fluoropolymer: 32 mm
Flexibility Minimum bending radius (Tube close bend radius) KB
TQ: 9 mm TL: 20 mm TQ: 18 mm
(Fluoropolymer Tubing, Super PFA) KR
∗1. Compared with SMC Fluoropolymer Tubing/TL (ø6 x ø4)
KA
KQG2
KG
Wearing
of outer Reduced to 1/30 KFG2
layer TQ: 1 mg TL: 30 mg ∗2 ∗2 MS
tube (Fluoropolymer Tubing)
∗2. Based on friction test of tubes
KKA
KP
Weight reduced Applications
Light LQ
weight by approximately
44%∗3 MQR
∗3. 2-Layer Soft Fluoropolymer Tubing (TQ): 26.5 g/m Automobile Semiconductor Food Medical Machine T
Fluoropolymer Tubing (TL): 47 g/m (ø8 x ø6) tools

Series Variations
Designation TQ0425 TQ0604 TQ0806 TQ1008 TQ1209
O.D. (mm) 4 6 8 10 12
I.D. (mm) 2.5 4 6 8 9
20 m roll
100 m roll
433 A
2-Layer Soft Fluoropolymer Tubing

Series TQ RoHS

Specifications
Designation TQ0425 TQ0604 TQ0806 TQ1008 TQ1209
O.D. (mm) 4 6 8 10 12
I.D. (mm) 2.5 4 6 8 9
20 m     
Roll
100 m     
Color Note 1) Translucent (Material color)
Fluid Note 2) Air, Water, Inert gas, Solvent
Insert fittings KF, KFG2, VCK series
How to measure the Applicable fittings Note 3) Miniature fittings M, MS series (Hose nipple type)
minimum bending radius Fluoropolymer fittings LQ1, LQ3 series Note 6)
Bend the tube into a U shape Max. operating Note 4)
at a temperature of 20°C. Fix 20°C 2.0 1.9 1.5 1.1 1.2
pressure (MPa)
Fixed one end and bend the loop
end gradually at 100 mm/min. Min. bending radius (tube close bend radius) Note 5) (mm) 4 9 26 42 37
Measure 2R when the tube Fluid temperature (fixed usage) Air, Inert gas: –20 to 100°C, Water, Solvent: 0 to 70°C (No freezing)
breaks or is crushed. Material Inner layer: Special fluoropolymer, Outer layer: Special nylon resin
Note 1) There may be plasticizer (white powder) deposits on the external surface of the tube. Please be careful
when the tube is used in clean rooms. Otherwise, the clean level may decrease.
Note 2) When solvent is used, make sure to test in the same environment as the actual operating environment, and
confirm that no problem will occur in the operating conditions. The standard value of the Applicable Fluid
How to Order List below is the reference value based on the test result performed under specific conditions.
The product can be physically affected by temperature, pressure, chemical density, etc, causing permeation
or swelling, and this may cause some problems.
Note 3) Perform periodic maintenance inspections. If leakage continues to occur after tightening, replace the tube

TQ0425 20 with a new one. (Refer to Maintenance in the Specific Product Precautions on page 435.)
When the tube rotates, perform a test to make sure no problem occur in the actual operating conditions.
When the product is used with motion for a long time, or at a high temperature, the tubes may have leakage
due to deterioration of the materials.
Length per roll Note 4) Observe the lesser value of the maximum operating pressure between the tubing and fitting. The surge
Tubing designation pressure must not exceed the maximum operating pressure. If the surge pressure exceeds the maximum
Symbol Length operating pressure, it will result in damage to tubes and fittings. Furthermore, abnormal temperature rise
20 20 m caused by adiabatic compression may result in the tube bursting.
Note 5) Minimum bend radius (tube close bend radius) is not guaranteed. The value of 2R in the left figure is
100 100 m measured with a bent or flattened tube.
Note 6) For the installation of fluoropolymer fitting LQ1 and LQ3, please contact SMC.

Applicable Fluid List Max. Operating Pressure


Fluid in the list below are chemically inert , to tubing material. Possible physical
Note 1)
Unit: MPa
effects may occur such as penetration and swelling due to temperature, pressure and Temperature (°C) TQ0425 TQ0604 TQ0806 TQ1008 TQ1209
chemical density. To use tubing in a solvent environment, tests should be performed
–20 to 20 2.0 1.9 1.5 1.1 1.2
with the same environment to ensure no problem occurs with operating environment.
30 1.7 1.6 1.2 0.9 1.0
40 1.4 1.4 1.0 0.8 0.9
Inner layer Outer layer Inner layer Outer layer
Chemical Chemical 50 1.2 1.1 0.8 0.6 0.8
Special fluoropolymer Special nylon resin Special fluoropolymer Special nylon resin
Hydrochloric acid   Citric acid   60 1.1 1.0 0.7 0.5 0.7
Sulfuric acid   Stearic acid   70 1.0 0.9 0.6 0.4 0.6
Nitric acid  × Formic acid   80 0.9 0.8 0.5 0.4 0.5
Caustic soda   Ethyl acetate   90 0.8 0.7 0.4 0.3 0.4
Caustic potash   Butyl acetate   100 0.7 0.6 0.4 0.3 0.3
Ammonlum hydroxide   Methyl alcohol  
Hydrogen peroxide   Ethyl alcohol  
Water   Butyl alcohol  
Phenol  × Isopropyl alcohol  
Benzene   Cellosolve  
Toluene   Hexane  
Xylene   Cyclohexane  
Carbon tetrachlorlde  × Mineral oil ASTM No.3  
Acetone   Naphtha  
Methyl ethyl ketone  
Note 1) “Chemically inert” means – not to cause any chemical reaction.
Note 2) Criteria:  Applicable,  Not recommended, × Inapplicable
Note 3) Applicable Fluid List shows the reference value based on test results performed
under specific conditions. Application for products is not guaranteed.
Note 4) Applicable Fluid List is for tube materials. For use in environments containing
solvents, please contact SMC.
A 434
Series TQ
Specific Product Precautions
Be sure to read before handling.
Refer to front matter 56 for Safety Instructions and pages 13 to 16 for Fittings and
Tubing Precautions.

Selection Mounting

Warning Caution
1. Check the specifications. 7. Mount so that tubing is not damaged due to tangling
Give careful consideration to operating conditions such as the and abrasion. This can cause flattening, bursting or
KQ2
application, fluid and environment, and use within the operating disconnection of tubing, etc. If the LQ1 or LQ3 fitting is
ranges specified in this catalog. Tube may burst or lead to used, connect the tube with the specialized tool. KQB2
operation failure if operating conditions are out of the specification Refer to the pamphlet “High-Purity Fluoropolymer Fittings HY-
range. The specifications of the catalog are designed assuming KS
PER FITTING/Series LQ1, 2 Work Procedure Instructions” KX
the product is used with the fixed conditions. (M-E05-1) or “High Purity Fluoropolymer Fittings Hyper Fitting
2. When using the product for medical care / Flare Type Series LQ3 Fitting Procedure” (M-E06-4) for con- KM
This product is designed for use with compressed fluid system necting tubing and special tools. (Downloadable from our web-
applications for medical care purposes. Do not use in contact with site)
human bodily fluids, body tissues or transfer applications to a KF
human living body.
3. Maintenance M
Perform periodic maintenance inspections, securing enough
space for maintenance.
H/DL
L/LL
4. Countermeasures for static electricity
Since static electricity may be generated depending on the fluid KC
being used, implement suitable countermeasures.
KK
Caution KK130
1. When toxic solvent is used, make sure to test in the Operating Environment
same environment as the actual operating environ-
ment, and confirm that no problem will occur in the DM
operating conditions. Warning
2. When the joint of the tube or fitting rotates, make sure 1. Do not use in locations having an explosive atmo- KDM
to test it in the same environment as the actual operat- sphere.
ing environment, and confirm that no problems will
2. When vibration or impact is applied, make sure to test KB
occur in the operating conditions.
in the same environment as the actual operating envi-
3. The surge pressure must not exceed the maximum ronment, and confirm that no problem will occur in the KR
operating pressure. operating conditions.
4. There may be plasticizer (white powder) deposits on
the external surface of the tube. Please be careful 3. In locations near heat sources, block off radiated heat. KA
when the tube is used in clean rooms. Otherwise, the
clean level may decrease. KQG2
5. If fittings of brands other than SMC are used, be sure Maintenance
to confirm that no problem will occur with the operat- KG
ing conditions. Caution
6. Trademark, product number, the material of inner/ 1. Check the following after the initial installation and for KFG2
outer layer, O.D. x I.D. size, production lot number, and each periodic inspection. If any problem is confirmed,
country of origin are printed in 500 mm intervals on
the outer surface of the tube. Printed letters may be
replace the tube with a new product or reconsider the MS
customer's operating conditions.
erased depending on fluid.
a) Cracks, gouges, wearing, corrosion KKA
Mounting b) Leakage, penetration, dissolution
c) Twists or crushing of tubing
KP
Caution d) Hardening, deterioration, softening of tubing
∗ There may be plasticizer (white powder) deposits on the surface
1. Check the model number, size, etc. before installing. of the tube, but there is no impact on performance. LQ
Check tubing for damage, gouges, cracks, etc. 2. The two layers of the tube are completely bonded. If
2. Before piping, perform air blow (flushing) or cleaning separation is confirmed between them, replace the MQR
to remove any dust, etc. from the piping. tube with a new one or reconsider the customer’s op-
3. There may be plasticizer (white powder) deposits on erating conditions. T
the surface of the tube, but there is no impact on 3. If the tube and the fitting are removed or replaced,
performance. eliminate the residual fluid with air or water.
4. Cut the tube perpendicularly using a tube cutter.
4. When using insert, miniature or fluoropolymer fittings
If the tube is cut incorrectly, fluid can leak or the tube can fall out
over a long period, some leakage may occur due to
as a result.
age deterioration of the materials. If any leakage is de-
5. When connecting tubing, allow a sufficient margin tected, correct the problem by additional tightening. If
considering the change of tube diameter and length tightening becomes ineffective, replace the fittings
due to pressure.
with a new product immediately.
6. Do not apply unnecessary forces such as twisting,
pulling, moment loads on fittings or tubing. It may cause 5. Do not repair or patch the replaced tubing or fittings
leakage, the fitting to fracture or the tube to be crushed, for reuse.
burst or fall off.
435
Antistatic Tubing

Series TA RoHS

Conductive tube prevents troubles caused by static electricity.


Antistatic Soft Nylon Tubing: Series TAS
For pneumatic piping and Model/Specifications  — 20 m roll  — 100 m reel
applications which require Model TAS3222 TAS0425 TAS0604 TAS0805 TAS1065 TAS1208
the measures against Tubing O.D. (mm) 3.2 4 6 8 10 12
antistatic electricity. Tubing I.D. (mm) 2.2 2.5 4 5 6.5 8

Flame resistant tubing Black (B)


(Equivalent to UL-94
standard V-0)
Fluid Air
Max. operating pressure (at 20°C) 1.2 MPa
Burst pressure Refer to the burst pressure characteristics curve.
Antistatic one-touch fittings: Series KA
Recommended fittings
Miniature fittings: Series M and MS Note)
Minimum bending radius (mm) 12 12 15 19 27 32
Operating temperature 0 to 40°C
Burst Pressure Characteristics Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 standard V-0)
Curve and Operating Pressure Surface resistance 104 to 107 Ω
Note) Miniature fittings: Only the following types are available for Series M and MS
Burst pressure (MPa)

Burst Series M Series MS


pressu
re
M-3AU-3, M-3AU-4, M-5AU-3, M-5AU-4 MS-5AU-3, MS-5AU-4, MS-5AU-6
M-5AU-6, M-5H-4, M-5H-6 MS-5H-4, MS-5H-6

Maximum operating pressure

How to Order

Operating temperature (°C) TAS1065 B 100


Length per roll
Color
Tubing model Symbol Length
Precautions
Symbol Color
20 20 m roll
B Black
100 100 m reel

Be sure to read before handling.


Refer to front matter 56 for Safety
Instructions and pages 13 to 16 for
Fittings and Tubing Precautions.
Made to Order
Caution Coil Tubing Please contact SMC for details.
1. The maximum operating pressure is the
value at 20°C. Refer to the burst pressure
characteristics curve for other tempera-
tures. Avoid abnormal temperature rises
caused by adiabatic compression.
2. The value at temperature of 20°C and O.D.
variable rate 10% max.
3. Please exercise caution when using this
item in a clean room. There is a possibility
of plasticizer and other materials precipitat-
ing on the tube surface and detracting from
the cleanliness level of the room.

A 436
Antistatic Tubing Series TA

KQ2
KQB2
Antistatic Polyurethane Tubing: Series TAU KS
KX
For pneumatic piping and Model/Specifications  — 20 m roll  — 100 m reel
KM
applications which require Model TAU3220 TAU0425 TAU0604 TAU0805 TAU1065 TAU1208
the measures against Tubing O.D. (mm) 3.2 4 6 8 10 12
KF
antistatic electricity. Tubing I.D. (mm) 2 2.5 4 5 6.5 8

Flexible tubing Black (B) M


H/DL
L/LL
Fluid Air
Max. operating pressure at 20°C 0.9 MPa KC
Burst pressure Refer to the burst pressure characteristics curve.
Recommended fittings Antistatic one-touch fittings: Series KA Miniature fittings: Series M and MS Note) KK
Minimum bending radius (mm) 10 10 15 20 27 35
Burst Pressure Characteristics Operating temperature 0 to 40°C KK130
Curve and Operating Pressure Material Conductive polyurethane
Surface resistance 104 to 107 Ω DM
Burst Note) Miniature fittings: Only the following types are available for Series M and MS
Burst pressure (MPa)

pressu
re
Series M Series MS KDM
M-3AU-3, M-3AU-4, M-5AU-3, M-5AU-4 MS-5AU-3, MS-5AU-4, MS-5AU-6

Maximum operating pressure


M-5AU-6, M-5H-4, M-5H-6 MS-5H-4, MS-5H-6 KB
How to Order KR

Operating temperature (°C) TAU1065 B 100 KA


Length per roll
Tubing model Color Symbol Length KQG2
Precautions Symbol Color
B Black
20
100
20 m roll
100 m reel KG
Be sure to read before handling.
Made to Order
KFG2
Refer to front matter 56 for Safety
Coil Tubing Flat Tubing Please contact SMC for details.
Instructions and pages 13 to 16 for
Fittings and Tubing Precautions.
MS
Color Tubing
• 5 colors KKA
Caution
1. The maximum operating pressure is the
• Surface resistance 109 Ω
value at 20°C. Refer to the burst pressure
KP
characteristics curve for other tempera-
Specifications How to Order
tures. Avoid abnormal temperature rises Fluid Air LQ
caused by adiabatic compression. Max. operating
0.8 MPa TAU 0604 BU 20 X100
2. The value of the minimum bending radius
is measured at the temperature of 20°C as
pressure at 20°C MQR
Ambient and
shown below. 0 to 40°C
fluid temperature Antistatic
Polyurethane Tubing
Antistatic
polyurethane T
Bend the tube into U-form Material Antistatic polyurethane color tubing
at a temperature of 20°C.
Surface resistance 10 Ω
9
Fixed end

Fix one end and close Tubing size


Recommended Antistatic One-touch fittings: Series KA Length per roll
loop gradually. Measure
fittings Miniature fittings: Series M and MS Note) Symbol O.D. x I.D. Symbol Length
2R when the tube breaks
or is crushed. 0212 ø2 x ø1.2 20 20 m roll
Note) Miniature fittings: Only the following types are 0425 ø4 x ø2.5
available for Series M and MS
0604 ø6 x ø4 Color
3. Because ester polyurethane is adopted, Series M Series MS 0805 ø8 x ø5 Symbol Color Symbol Color
water cannot be used due to the occur- M-3AU-2, M-3AU-4 MS-5AU-4, MS-5AU-6 1065 ø10 x ø6.5 W White G Green
rence of hydrolysis. M-5AU-2, M-5AU-4 MS-5H-4, MS-5H-6 1208 ø12 x ø8 BU Blue C Clear
M-5AU-6, M-5H-4 B Black — —
M-5H-6

437 A
Fluoropolymer Tubing Variations
Series TL/TIL/TLM/TILM/TH/TIH/TD/TID
RoHS

High Purity Fluoropolymer Tubing Fluoropolymer Tubing (PFA) KQ2


Series TL/TIL Material Super PFA Series TLM/TILM Material PFA KQB2
It is suitable for applications which require a highly smooth The material consists of a good chemical resistant fluor- KS
KX
internal surface and small amount of elution of fluorine ions. opolymer. This also has good heat resistance, and it is suit-
∗ It has heat and chemical resistance equivalent to PFA. P.440 able for a wide range of applications. P.441 KM
KF
M
H/DL
L/LL

KC
KK
KK130
FEP Tubing (Fluoropolymer) Soft Fluoropolymer Tubing DM
Series TH/TIH Material FEP Series TD/TID Material Modified PTFE KDM
This has better resistance in chemical environments. Flexibility improved by approx. 20% KB
P.444 (Compared with SMC TL/TIL Series)
P.446
Suitable for applications which require flexibility. KR
KA
KQG2
KG
KFG2
MS
KKA
Series TL/TIL TLM/TILM TH/TIH TD/TID
Material Super PFA PFA FEP Modified PTFE KP
Chemical resistance 
Heat resistance 260°C 260°C 200°C 260°C LQ
Flexibility    
Ion elution   
MQR
  
Internal smoothness
T
Fluid Chemicals, Deionized water Chemicals, Deionized water Air, Water, Inert gas
Metric ø4 to ø19 ø2 to ø25 ø4 to ø12 ø4 to ø12
Tubing O.D.
Inch 1/8" to 1" 1/8" to 1 1/4" 1/8" to 3/4" 1/8" to 1/2"
Color Translucent Translucent, Red, Blue, Black Translucent, Red, Blue, Black Translucent
One-touch fittings — KQ2, KQG2, KP, KP KQ2, KQG2, KP, KP —
fitting series
Applicable

Miniature fittings — M, MS (Hose nipple type) M, MS (Hose nipple type) M, MS (Hose nipple type)
Insert fittings — KF, KFG2 KF, KFG2 KF, KFG2
Fluoropolymer fittings LQ1, LQ2, LQ3 LQ1, LQ2, LQ3 LQ1, LQ2, LQ3 LQ1, LQ2, LQ3
: Very good : Good : Moderate
The comparison table shown above was prepared based on a relative comparison taking the characteristics of each fluoropolymer tubing into consideration.
439
RoHS
High Purity
Fluoropolymer Tubing

Series TL/TIL Material: Super PFA

Series and Specifications


Metric sizes (Series TL) Inch sizes (Series TIL)
Tubing model TL0403 TL0604 TL0806 TL1008 TL1210 TL1916 TIL01 TILB01 TIL05 TIL07 TIL11 TIL13 TIL19 TIL25
Nominal diameter – – – – – – 1/8" 1/8" 3/16" 1/4" 3/8" 1/2" 3/4" 1"
Tubing size ø4 x ø3 ø6 x ø4 ø8 x ø6 ø10 x ø8 ø12 x ø10 ø19 x ø16 1/8" x 0.086" 1/8" x 1/16" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 7/8"
Basic
O.D. diameter 4 6 8 10 12 19 3.18 3.18 4.75 6.35 9.53 12.7 19.05 25.4
(mm) +0.2 +0.2
Tolerance ±0.1 −0.1 ±0.1 −0.1
Basic
Thickness diameter 0.5 1 1.5 0.5 0.8 0.8 1.2 1.6
(mm) Tolerance ±0.05 ±0.1 ±0.15 ±0.05 ±0.08 ±0.08 ±0.12 ±0.15
10 m – – –    – – – –   – –
20 m        –      
50 m        –      
Bundle
100 m        –      –
50 Ft (16 m) – – – – – –        
100 Ft (33 m) – – – – – –        
Straight pipe 2 m        –      
Color Translucent (color of material)
Applicable fluid Refer to the applicable fluid in page 448.
Max. operating Note 1)
pressure (at 20°C) 1 MPa 0.9 MPa 0.7 MPa 0.6 MPa 1 MPa 0.7 MPa 0.5 MPa
Burst pressure 4.9 MPa 6.9 MPa 4.7 MPa 3.6 MPa 2.9 MPa 2.6 MPa 6.4 MPa 9.9 MPa 6.7 MPa 7.9 MPa 6.7 MPa 4.6 MPa 2.8 MPa 2.0 MPa
(at 20°C)
Min. bending Note 2)
radius (mm) 20 40 65 110 160 12 6 20 30 60 160 290
Max. operating
260°C
temperature (Fixed use)
Material Super PFA
Note 1) • The maximum operating pressure is the value at 20°C. For other temperatures, calculate from the burst pressure drop At a temperature of
coefficient. 20°C bend the
Furthermore, an abnormal temperature increase due to adiabatic compression can cause tubing to burst.To operate at a 2R tubing into a U
Fixed side

temperature other than 20°C, the operating pressure must be no more than the value calculated using the equation shape. Then with
below: When the value (calculated using the formula below) exceeds 1 MPa, the Max. operating pressure is 1 MPa. one side fixed,
(Max. operating pressure) = 1/4 x (burst pressure drop coefficient) x (burst pressure at 20°C) gradually close the
• When using a fluid in liquid form, the surge pressure must be no more than the maximum operating pressure. other side and
A surge pressure higher than the maximum operating pressure can cause breakage of the fitting or bursting of the tubing. measure 2R at the
Note 2) The minimum bending radius is measured using the method shown in the figure at the right. point where the
Note 3) As for other commercial items, there are some cases it is not able to connect due to tolerance of dimensions. tubing folds or
flattens, etc.

Burst pressure drop curve How to Order


1.0

Metric sizes TL0604 20


Burst pressure drop coefficient

0.8

0.6
Inch sizes TIL01 20
Length Applicable to both
metric and inch size
0.4 Tubing Model
Symbol Type Length
0.2
10 10 m
20 20 m
Roll
50 50 m
0
20 40 60 80 100 120 140 160 180 200 220 240 260 100 100 m
Temperature (°C) 2S Straight 2m

Length Applicable to inch size only


Eluting fluorine ion amount Note 4) (µg/g) Eluting metal ion amount Note 4) (ng/cm2)
Symbol Type Length
Type Fluorine ion Type Al Fe Ni Na Ca
16 50 Ft (16 m)
Eluting amount 0.1 or less Eluting amount 4.5 0.3 0.2 7.1 1.3 Roll
33 100 Ft (33 m)
A 15 g piece of fluororesin tubing is cut off, washed The interior of the fluororesin tubing is washed with super deionized Please refer to the “Series and Specifications”
in DI water (puer water) and immersed in 15 mL of water. Approximately 20 g of super high purity hydrofluoric acid (48%)
is measured and injected into the tubing. The interior wall of the above, as the tubing length differs depending
25% methyl alcohol extract at room temperature for on each size.
tubing is immersed at normal temperature for one week with both
24 hours. Then the extract is diluted with DI water ends of the tubing plugged. Then the extract was diluted with super
(puer water) to be subjected to a quantitative deionized water to be subjected to a quantitative analysis on Al, Fe, Note 4) Figures shown in tables are representative
analysis of fluorine ions. Ni, Na and Ca by the stripping method. values, not guaranteed values.
440
Fluoropolymer Tubing PFA

Series TLM/TILM

RoHS

Max. operating temperature: 260°c KQ2


KQB2
KS

22 size variations
KX

KM
Metric size ø2 to ø25 (13 sizes) Inch size 1/8" to 1 1/4" (9 sizes) KF

Length per roll 10 m, 20 m, 50 m, 100 m Length per roll 10 m, 20 m, 50 m, 100 m


M
16 m (50 ft), 33 m (100 ft) H/DL
Straight 2m L/LL
Straight 2m KC

4 color variations Applications


KK
KK130
DM
Photovoltaic LCD HDD
cell manufacturing manufacturing KDM
Translucent
manufacturing
KB
Black (Opaque) KR
Medical Food
KA
KQG2
Blue (Translucent)
Compatible with KG
Food Sanitation Law
Red (Translucent) • Compatible with the test conforming to Japan’s KFG2
Food Sanitation Law based on the 370th
notice given by the Ministry of Health and
Welfare in 1959.
MS
• Complies with FDA (Food and Drug Adminis-
tration) §177-1550 dissolution test. KKA
KP
LQ
MQR
T

441
Fluoropolymer Tubing (PFA)
Metric Size

Series TLM RoHS


Series
Size Metric size
Model TLM0201 TLM0302 TLM0425 TLM0403 TLM0604 TLM0806 TLM1075 TLM1008 TLM1209 TLM1210 TLM1613 TLM1916 TLM2522
Tubing size ø2 x ø1 ø3 x ø2 ø4 x ø2.5 ø4 x ø3 ø6 x ø4 ø8 x ø6 ø10 x ø7.5 ø10 x ø8 ø12 x ø9 ø12 x ø10 ø16 x ø13 ø19 x ø16 ø25 x ø22
O.D. (mm) 2 3 4 4 6 8 10 10 12 12 16 19 25
I.D. (mm) 1 2 2.5 3 4 6 7.5 8 9 10 13 16 22
Length per roll Color Symbol
10 m Translucent N      
Translucent N             
Red (Translucent) R             
20 m
Roll Blue (Translucent) BU             
Black (Opaque) B             
50 m Translucent N             
100 m Translucent N            
Straight 2 m Translucent N             

Inch O.D. size Inch O.D. size O.D. 3.2 mm is available in ø 1/8 inch (3.18 mm) tubing.
5/32" 5/16" For details, refer to the table “Series” on page 443.

Specifications
Fluid: Refer to “Applicable Fluid List” on page 449. Fittings: Fluoropolymer fittings series LQ
Fluid Note 1) 2) 3) and
applicable fittings Note 1) 2) 3) Fluid: Air, Water, Inert gas Fittings: One-touch fittings KQ2, KQG2, Clean One-touch fittings KP, KP
Insert fittings KF, KFG2, Miniature fittings M, MS (Hose nipple type)
Max. operating pressure (MPa) Refer to the max. operating pressure curve.
Min. bending Recommended radius 10 20 20 35 35 60 95 100 100 130 160 220 400
radius (mm) Note 4) Tube close bend radius 7 15 15 20 20 40 60 65 65 110 130 160 290
Max. operating temperature 260°C
Material PFA (Tetrafluoroethylene perfluoroalkoxy vinyl ether copolymer)
Note 1) Fluid varies depending on the applicable fittings. How to measure the
Note 2) When using a liquid fluid, the surge pressure must not exceed the maximum operating pressure. If the surge pressure minimum bending radius
exceeds the maximum operating pressure, it will result in damage to fittings and tubes. Furthermore, abnormal
temperature rise caused by adiabatic compression may result in the tube bursting.
Note 3) Do not use this product in a manner in which the tube is not fixed. Observe the lesser value of the maximum operating
pressure between the tubing and fitting. A material change over a long duration or due to high-temperature may cause
leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected. Fixed
(Refer to “Maintenance” of the tubing precautions on page 451.) end
For other precautions, refer to “Fittings & Tubing Precautions” on pages 13 to 16. When using the fluoropolymer fittings,
refer to the precautions on pages 395 and 396.
Note 4) Minimum bending radius is measured as shown left as representative values.
• Use a tube above the recommended minimum bending radius.
• The tube may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close At a temperature of 20°C, bend the
tubing into a U shape. Fix one end
bend radius and make sure that the tube is not bent or flattened. and gradually move the other end
• Please note that the tube close bend radius is not warranted because of the value when 2R is measured by the method closer. Measure 2R at the point
in the right figure if the tube is bent or flattened, etc. where the outside diameter’s rate of
change is 5%.
Max. Operating Pressure
Max. operating pressure (MPa)
Group Model
2.4 20°C 100°C 200°C 260°C
Max. operating pressure MPa

2.2 A TLM0201 2.3 1.1 0.55 0.3


A
2.0 B TLM0425 1.7 0.9 0.45 0.23
1.8 TLM0302
B C 1.5 0.7 0.35 0.2
1.6 TLM0604
1.4 TLM0403
1.2
C TLM0806
D 1 0.5 0.25 0.15
1.0 TLM1075
0.8 TLM1209
0.6 TLM1008
E 0.7 0.35 0.17 0.11
0.4 TLM1613
0.2 TLM1210
F 0.6 0.3 0.15 0.1
0.0 TLM1916
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 G TLM2522 0.4 0.2 0.1 0.05
Operating temperature °C
How to Order
1.2
Metric size
Max. operating pressure MPa

TLM0425 N 20
1.0

0.8
E
Tubing Length per roll
0.6
F designation Symbol Type Length
0.4
10 10 m
G Color indication 20 20 m
Roll
Symbol Color 50 50 m
0.2 N Translucent 100 100 m
R Red (Translucent) 2S Straight 2m
0.0 BU Blue (Translucent)
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Note) Refer to the table “Series”
B Black (Opaque) above, as the tubing length
Operating temperature °C
differs depending on each size.
A 442
Fluoropolymer Tubing (PFA)
Inch Size

Series TILM RoHS


Series
Size
Model TILM01 TILMB01 TILM05 TILM07
Inch size
TILM11 TILM13 TILM19 TILM25 TILM32 KQ2
Tubing size 1/8" x 0.086" 1/8" x 1/16" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 7/8" 11/4" x 11/10"
O.D.
inch
mm
1/8"
3.18
1/8" 3/16"
4.75
1/4"
6.35
3/8"
9.53
1/2"
12.7
3/4"
19.05
1"
25.4
11/4"
31.75
KQB2
inch 0.086" 1/16" 1/8" 5/32" 1/4" 3/8" 5/8" 7/8" 11/10" KS
I.D.
mm 2.18 1.58 3.15 3.95 6.33 9.5 15.85 22.2 27.95 KX
Length per roll Color Symbol
10 m Translucent N   KM
Translucent N         
Red (Translucent) R         
20 m
Blue (Translucent) BU          KF
Roll Black (Opaque) B         
50 m Translucent N
100 m Translucent N












 
M
16 m ( 50 ft) Translucent N         
33 m (100 ft) Translucent N         
H/DL
Straight 2 m Translucent N        
L/LL

Metric O.D. size O.D. 5/32" is available in ø4 metric tubing, and O.D. 5/16" is available KC
3.2 in ø8 metric tubing. For details, refer to the table “Series” on page 442.

KK
Specifications
Fluid Note 1) 2) 3) and
applicable fittings Note 1) 2) 3)
Fluid: Refer to “Applicable Fluid List” on page 449. Fittings: Fluoropolymer fittings series LQ
Fluid: Air, Water, Inert gas Fittings: One-touch fittings KQ2, KQG2, Insert fittings KFG2
KK130
Max. operating pressure (MPa) Refer to the max. operating pressure curve.
Min. bending Recommended radius
radius (mm) Note 4) Tube close bend radius
20 10 25 35 60 95 220 400 500 DM
12 6 20 20 30 60 160 290 360
Max. operating temperature 260°C
Material PFA (Tetrafluoroethylene perfluoroalkoxy vinyl ether copolymer) KDM
Note 1) Fluid varies depending on the applicable fittings. How to measure the
minimum bending radius
Note 2) When using a liquid fluid, the surge pressure must not exceed the maximum operating pressure. If the surge pressure
exceeds the maximum operating pressure, it will result in damage to fittings and tubes. Furthermore, abnormal KB
temperature rise caused by adiabatic compression may result in the tube bursting.
Note 3) Do not use this product in a manner in which the tube is not fixed. Observe the lesser value of the maximum operating
pressure between the tube and fitting. A material change over a long duration or due to high-temperature may cause KR
leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected. Fixed
end
(Refer to “Maintenance” of the tubing precautions on page 451.)
For other precautions, refer to “Fittings & Tubing Precautions” on pages 13 to 16. When using the fluoropolymer fittings, KA
refer to the precautions on pages 395 and 396.
Note 4) Minimum bending radius is measured as shown left as representative values.
• Use a tube above the recommended minimum bending radius. KQG2
• The tube may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close At a temperature of 20°C, bend the
tubing into a U shape. Fix one end
bend radius and make sure that the tube is not bent or flattened.
• Please note that the tube close bend radius is not warranted because of the value when 2R is measured by the method
and gradually move the other end
closer. Measure 2R at the point KG
in the right figure if the tube is bent or flattened, etc. where the outside diameter’s rate of
change is 5%.
Max. Operating Pressure Max. operating pressure (MPa)
KFG2
Group Model
2.4 20°C 100°C 200°C 260°C
MS
Max. operating pressure MPa

2.2 A TILMB01 2.3 1.1 0.55 0.3


2.0
A B TILM07 1.7 0.9 0.45 0.23
1.8 TILM05
1.6 B C
TILM11
1.5 0.7 0.35 0.2 KKA
1.4 TILM01
1.2 C D 1 0.5 0.25 0.15
1.0
F
TILM13
TILM19 0.6 0.3 0.15 0.1
KP
0.8
TILM25
0.6
0.4
G
TILM32
0.4 0.2 0.1 0.05
LQ
0.2
0.0
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260
How to Order MQR
Operating temperature °C
Inch size
T
1.2
TILM01 N 20
Max. operating pressure MPa

D
1.0
Tubing Length per roll
0.8 designation Symbol Type Length
10 10 m
0.6
F Color indication 20 20 m
Symbol Color 50 50 m
0.4 Roll
G N Translucent 100 100 m
0.2 R Red (Translucent) 16 16 m (50 ft)
BU Blue (Translucent) 33 33 m (100 ft)
0.0 B Black (Opaque) 2S Straight 2m
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Note) Refer to the table “Series” above, as
Operating temperature °C the tubing length differs depending
on each size.
443 A
FEP Tubing (Fluoropolymer)
Metric Size

Series TH RoHS
Series -20 m roll -100 m roll
Metric size
Model TH0402 TH0425 TH0604 TH0806 TH1075 TH1008 TH1209 TH1210
Tubing O.D. (mm) 4 4 6 8 10 10 12 12
Tubing I.D. (mm) 2 2.5 4 6 7.5 8 9 10

Color Symbol
Translucent N
Red (Translucent) R
Blue (Translucent) BU
Black (Opaque) B

Inch nominal size Inch nominal size


5/32" 5/16"
Operating Temperature: Max. 200°C
It varies depending on the operating pressure. Refer Specifications
to the graph for the maximum operating pressure. Fluid Air, Water Note 1), Inert gas
Compatible with the Food Sanitation Law Applicable Note 2)
One-touch fittings, Insert fittings
• Compatible with the test conforming to the Food Fluoropolymer fittings: Series LQ Note 3)
fittings
Sanitation Law based on the 370th notice given Miniature fittings: Series M, MS (Hose nipple type)
by the Ministry of Health and Welfare in 1959.
• Complies with FDA (Food and Drug Administra- 20°C 2.3 1.7 1.5 1 0.7 1 0.7
tion) §177-1550 dissolution test. Max. operating 100°C 0.85 0.6 0.55 0.4 0.25 0.4 0.25
pressure (MPa) 200°C 0.4 0.3 0.3 0.2 0.1 0.2 0.1
How to measure the minimum
bending radius. Refer to below “Max. Operating Pressure.”
Min. bending Recommended 15 20 35 60 95 100 130
radius radius
Fixed end

(mm) Note 4) Tube close bend


radius 10 15 20 40 60 65 110
Operating temperature Air, Inert gas: -20 to 200°C Water: 0 to 100°C (No freezing)
Material FEP (Fluorinated Ethylene Propylene Resin)
Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure. A surge
pressure higher than the maximum operating pressure can cause breakage of the fittings, or rupture of the tubing.
At a temperature of 20°C, bend Furthermore, an abnormal temperature increase due to adiabatic compression can also result in ruptured tubing.
the tubing into a U shape. Fix Note 2) Do not use in locations where the FEP tubing will move.
one end and gradually move the Be sure to operate under the maximum operating pressure conditions using the lower maximum operating
other end closer. Measure 2R at specification of either the tubing or fittings.
the point where the outside After long term use or under high temperatures, some fittings leakage may occur due to material deterioration with
diameter's rate of change is 5%. age. Perform periodic inspections, and if any leakage is detected, replace with a new product immediately.
When the insert and miniature fittings are used over extended periods of time, it may cause leakage due to the
material deterioration of age. In such a case, give an additional tightening to the tube connection part. If leakage
Max. Operating Pressure still occurs after giving an additional tightening, replace the fitting with a new product. For other precautions, refer
to “Fittings & Tubing Precautions”. When using the fluoropolymer fittings, refer to the precautions on pages 395
3 and 396. Select the size after confirming O.D. and I.D.
Note 3) TH0402, TH0425, TH1075 and TH1209 are not available because of different internal diameters.
Note 4) The minimum bending radius is the representative value measured as shown in the left figure.
TH0402 • Use a tube above the recommended minimum bending radius.
Max. Operating Pressure MPa

• The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube
close bend radius and make sure that the tubing is not bent or flattened.
2
• Please note that the tube close bend radius is not warranted because of the value when 2R is measured by the
TH0425 method in the left figure if the tubing is bent or flattened, etc.
TH0604
TH0806/TH1075/TH1209 How to Order
TH1008/TH1210
Metric size
1

TH0604 N 20
0.5
Indication of tubing model Length per roll
Color indication
Symbol Roll size
0 Symbol Color
020 20 m roll
-20 0 20 40 60 80 100120140 160 180200 N Translucent
100 Note) 100 m roll
Operating Temperature °C R Red (Translucent)
Note) 100 m roll is available
BU Blue (Translucent)
Note) The maximum operating pressure varies dependant with translucent (color
on the I.D. bore size even if the O.D. is the same. B Black (Opaque) indication: N) only.
B 444
FEP Tubing (Fluoropolymer): Metric Size Series TH

Made to Order
(Please contact SMC for specifications in detail, dimensions, delivery and specifications other than those mentioned above.)
Reinforced corrugated
cardboard specification ø6, Translucent only: Suffix “-X64” to the end of part number. Ex.) TH0604N-500-X64
longer length reel

Made to Order Availability


Part no. Length Model TH0604N Color
250 m reel
X64 Translucent
500 m reel

444-1 A
FEP Tubing (Fluoropolymer)
Inch Size

Series TIH RoHS

Series -50 ft (16 m) roll -100 ft (33 m) roll


KQ2
Inch size
Model TIHA01 TIHB01 TIHC01 TIHA05 TIHB05 TIHA07 TIHB07 TIHA11 TIHB11 TIH13 TIH19 KQB2
inch 1/8" 3/16" 1/4" 3/8" 1/2" 3/4"
Tubing O.D. KS
mm 3.18 4.75 6.35 9.53 12.7 19.05 KX
0.124" 0.156" 0.25" 0.374" 0.624"
Tubing I.D.
inch 0.093" 0.086" 0.065" 0.137"
(1/8")
0.18"
(5/32")
0.275"
(1/4") (3/8") (5/8") KM
mm 2.36 2.18 1.65 3.48 3.15 4.57 3.95 6.99 6.33 9.5 15.85
KF
Color Symbol
Translucent N M
Red (Translucent) R H/DL
Blue (Translucent) BU L/LL
Operating Temperature: Max. 200°C Black (Opaque) B
It varies depending on the operating pressure. Refer KC
to the graph for the maximum operating pressure.
Specifications KK
Compatible with the Food Sanitation Law Fluid Air, Water Note 1), Inert gas
• Compatible with the test conforming to the Food
Sanitation Law based on the 370th notice given Applicable fittings Note 2) One-touch fittings, Fluoropolymer fittings: Series LQ Note 3) KK130
by the Ministry of Health and Welfare in 1959. 20°C 1 2.3 1 1.5 1 1.7 1 1.5 1 0.7
• Complies with FDA (Food and Drug Administra- Max. operating 100°C 0.4 0.85 0.4 0.55 0.4 0.6 0.4 0.55 0.4 0.25 DM
tion) §177-1550 dissolution test. pressure (MPa) 200°C 0.2 0.4 0.2 0.3 0.2 0.3 0.2 0.3 0.2 0.1
How to measure the minimum KDM
Refer to below “Max. Operating Pressure.”
bending radius.
Min. bending Recommended
radius radius 25 20 10 35 25 55 35 85 60 95 220 KB
(mm) Note 4) Tube close bend 20 12 7 25 20 35 20 55 30 60 160
Fixed end

radius
Operating temperature Air, Inert gas: -20 to 200°C Water: 0 to 100°C (No freezing) KR
Material FEP (Fluorinated Ethylene Propylene Resin)
Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure. A surge KA
pressure higher than the maximum operating pressure can cause breakage of the fittings, or rupture of the tubing.
At a temperature of 20°C, bend Furthermore, an abnormal temperature increase due to adiabatic compression can also result in ruptured tubing. KQG2
the tubing into a U shape. Fix Note 2) Do not use in locations where the FEP tubing will move.
Be sure to operate under the maximum operating pressure conditions using the lower maximum operating
one end and gradually move the
specification of either the tubing or fittings. KG
other end closer. Measure 2R at After long term use or under high temperatures, some fittings leakage may occur due to material deterioration with
the point where the outside
diameter's rate of change is 5%.
age. Perform periodic inspections, and if any leakage is detected, replace with a new product immediately. KFG2
When the insert and miniature fittings are used over extended periods of time, it may cause leakage due to the
material deterioration of age. In such a case, give an additional tightening to the tube connection part. If leakage
Max. Operating Pressure still occurs after giving an additional tightening, replace the fitting with a new product. For other precautions, refer MS
to “Fittings & Tubing Precautions”. When using the fluoropolymer fittings, refer to the precautions on pages 395
3 and 396. Select the size after confirming O.D. and I.D. KKA
Note 3) TIHA01, TIHC01, TIHA05, TIHA07 and TIHA11 are not available because of different internal diameters.
Note 4) The minimum bending radius is the representative value measured as shown in the left figure.
TIHC01 • Use a tube above the recommended minimum bending radius. KP
Max. Operating Pressure MPa

• The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube
TIHB05/TIHB11
close bend radius and make sure that the tubing is not bent or flattened. LQ
2 • Please note that the tube close bend radius is not warranted because of the value when 2R is measured by the
TIHB07 method in the left figure if the tubing is bent or flattened, etc.
TIHA01/TIHB01/TIHA05
MQR
TIHA07/TIHA11/TIH13 How to Order
T
Inch size

TIHA01 N 16
1
TIH19

0.5
Indication of tubing model Length per roll
Color indication Symbol Roll size
0 Symbol Color 50 ft (16 m) roll
16
-20 0 20 40 60 80 100120140 160 180200 N Translucent
33 Note) 100 ft (33 m) roll
Operating Temperature °C R Red (Translucent)
Note) 100 ft (33 m) roll is
BU Blue (Translucent) available with translucent
Note) The maximum operating pressure varies dependant
on the I.D. bore size even if the O.D. is the same. B Black (Opaque) (color indication: N) only.
445 B
Soft Fluoropolymer Tubing
Metric Size

Series TD RoHS

Model/Specifications
Size Metric size
Model TD0425 TD0604 TD0806 TD1075 TD1209
Tubing O.D. (mm) 4 6 8 10 12
Tubing I.D. (mm) 2.5 4 6 7.5 9

Roll
10 m     
20 m     
Color Translucent (material color)
Applicable fluid Refer to the applicable fluid in page 448.
Fluid Note 1) Air, Water Note 1), Inert gas
Insert Fittings KF series
Applicable fittings Note 2) Stainless Steel 316 Insert Fittings KFG series
Miniature fittings M, MS series (Hose nipple type)
Flexibility: Improved by approx. 20% Fluoropolymer fitting series LQ
* SMC comparison (Fluoropolymer tubing,
Series TL/TIL) 20°C 1.6 1.4 0.9 0.9 0.9
Max. operating 100°C 0.9 0.7 0.5 0.5 0.5
Compatible with the Food Sanitation Law pressure (MPa) 200°C 0.45 0.35 0.25 0.25 0.25
• Compatible with the test conforming to the Food
260°C 0.23 0.2 0.15 0.15 0.15
Sanitation Law based on the 370th notice given by
the Ministry of Health and Welfare in 1959. Min. bending Recommended radius 15 25 45 55 75
• Complies with FDA (Food and Drug Adminis- radius (mm) Note 3) Tube close bend radius 8 16 31 35 41
tration) §177-1550 dissolution test. Max. operating temperature (fixed usage) 260°C
Material Modified PTFE (Polytetrafluoroethylene resin)
Operating Temperature: Max. 260°C Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure.
It varies depending on the operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to
Refer to the graph for the maximum operating fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression
pressure. may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed.
How to measure Observe the lesser value of the maximum operating pressure between the tubing and fittings.
the minimum A material change over a long duration or due to high-temperature may cause leakage.
bending radius Perform periodic maintenance and replace with a new product immediately when abnormali-
ties are detected.
(Refer to “Maintenance” of the tubing precautions on page 451.)
Bend the tubing into the
For other precautions, refer to “Fittings & Tubing Precautions” on pages 13 to 16. When using
U-form at a temperature
Fixed end

the fluoropolymer fittings, refer to the precautions on pages 395 and 396.
of 20°C. Fix one end Note 3) The minimum bending radius is the representative value measured as shown in the left figure.
and close loop gradu- • Use a tube above the recommended minimum bending radius.
ally. Measure 2R when • The tubing may be bent if used under the recommended minimum bending radius.
the deformed ratio of the Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
tubing diameter at • Please note that the tube close bend radius is not warranted because of the value when 2R
bending reaches 5%. is measured by the method in the left figure if the tubing is bent or flattened, etc.

Maximum Operating Pressure How to Order


Metric size
2.0
1.8
TD0425 10
Max. operating pressure MPa

TD0425
1.6 Length per roll
Symbol Length
1.4 TD0604
10 10 m roll
1.2
20 20 m roll
1.0 TD0806/TD1075/TD1209
0.8 Tubing model
0.6
0.4
0.2
0.0
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

Operating temperature °C

A 446
Soft Fluoropolymer Tubing
Inch Size

Series TID RoHS

KQ2
Model/Specifications
Size Inch size KQB2
Model TID01 TID05 TID07 TID11 TID13
KS
inch 1/8" 3/16" 1/4" 3/8" 1/2" KX
Tubing O.D.
mm 3.18 4.75 6.35 9.53 12.7

0.086"
0.124" 0.156" 0.25" 0.374" KM
Tubing I.D. inch (1/8") (5/32") (1/4") (3/8")
mm 2.18 3.15 3.95 6.33 9.5 KF
Roll
8m     
16 m      M
Color Translucent (material color)
H/DL
Applicable fluid Refer to the applicable fluid in page 448. L/LL
Flexibility: Improved by approx. 20% Fluid Note 1) Air, Water Note 1), Inert gas
* SMC comparison (Fluoropolymer tubing,
Series TL/TIL)
Applicable fittings Note 2) Fluoropolymer fitting series LQ KC
20°C 1.4 1.4 1.6 1.4 0.9
Compatible with the Food Sanitation Law Max. operating 100°C 0.7 0.7 0.9 0.7 0.5 KK
• Compatible with the test conforming to the Food pressure (MPa) 200°C 0.35 0.35 0.45 0.35 0.25
Sanitation Law based on the 370th notice given by 260°C 0.2 0.2 0.23 0.2 0.15 KK130
the Ministry of Health and Welfare in 1959. 15 20 25 40 75
Min. bending Recommended radius
• Complies with FDA (Food and Drug Adminis-
tration) §177-1550 dissolution test.
radius (mm) Note 3) Tube close bend radius 9 10 15 23 42 DM
Max. operating temperature (fixed usage) 260°C
Operating Temperature: Max. 260°C Material Modified PTFE (Polytetrafluoroethylene resin) KDM
It varies depending on the operating pressure. Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If
Refer to the graph for the maximum operating the surge pressure exceeds the maximum operating pressure, it will result in damage to fittings KB
pressure. and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may
result in the tubing bursting.
How to measure Note 2) Do not use this product in a matter in which the modified PTFE tubing is not fixed. KR
the minimum Observe the lesser value of the maximum operating pressure between the tubing and fittings.
bending radius A material change over a long duration or due to high-temperature may cause leakage. KA
Perform periodic maintenance and replace with a new product immediately when abnormali-
ties are detected.
Bend the tubing into the (Refer to “Maintenance” of the tubing precautions on page 451.) KQG2
U-form at a temperature For other precautions, refer to “Fittings & Tubing Precautions” on pages 13 to 16. When using
Fixed end

of 20°C. Fix one end


and close loop gradu-
the fluoropolymer fittings, refer to the precautions on pages 395 and 396.
Note 3) The minimum bending radius is the representative value measured as shown in the left figure.
KG
ally. Measure 2R when • Use a tube above the recommended minimum bending radius.
the deformed ratio of the • The tubing may be bent if used under the recommended minimum bending radius. KFG2
tubing diameter at Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
bending reaches 5%. • Please note that the tube close bend radius is not warranted because of the value when 2R
is measured by the method in the left figure if the tubing is bent or flattened, etc.
MS
KKA
Maximum Operating Pressure How to Order
Inch size
KP
2.0
1.8
TID01 8 LQ
Max. operating pressure MPa

TID07
1.6 Length per roll MQR
Symbol Length
1.4 TID01/TID05/TID11
1.2
8 25 ft (8 m) roll T
16 50 ft (16 m) roll
1.0 TID13
0.8 Tubing model
0.6
0.4
0.2
0.0
−20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300

Operating temperature °C

447 A
Series TL/TIL/TD/TID
Applicable Fluid List
Chemical resistance of Fluoropolymer Super PFA, modified PTFE material
Chemicals in the list below are chemically inert Note) to Super PFA, modified PTFE material. Possible physical
effects may occur such as penetration and swelling due to temperature, pressure and chemical concentration.
To use Super PFA, modified PTFE tube in a chemical environment, tests should be performed with the same
environment to ensure no problem occurs with operating environment.

1,1,1-Trichloroethane Formic acid Trichloroethylene


1,1,2-Trichloroethane Ethyl formate Trichloroacetic acid
1,2,3-Trichloropropane Propyl formate Toluene
1,2-Dichlorobutane Methyl formate Naphtha
2,4-Dichlorotoluene Xylene Carbon dioxide
2-chloropropane Glycol Nitrogen dioxide
2-nitro-2-methylpropane Glycerine Nitrobenzene
2-nitrobutanol Cresol Nitromethane
Pentabasic benzamide Chromic acid Carbon disulfide
Hydrochlorofluorocarbon-22 Chloracetic acid Piperidine
N-octadecanol Chlorosulfonic acid Pyridine
N-butylamine Chloroform Pyrogallol
o-chlorotoluene Paraffinum liquidum Phenol
Isobutyl adipate Acetate Butanol
Acetyl chloride Amyl acetate Phthalic acid
Acetophenone Ethyl acetate Hydrofluoric acid
Acetone Potassium Furan
Aniline Butyl acetate Ethyl propionate
Sulfurous acid gas Propyl acetate Propyl propionate
Allyl chloride Methyl acetate Methylpropionate
Benzoic acid Salicylic acid Propylene chloride
Ammonium Sodium hypochlorite Bromobenzene
Sulfur Diisobutyl ketone Hexachlorethane
Isoamyl alcohol Diethylamine Hexane
Isooctane Carbon tetrachloride Heptane
Ethanol Dioxane Benzyl alcohol
Ethyl ether Cyclohexanone Benzaldehyde
Ethylene glycol Cyclohexane Benzine
Ethylene chloride Dichloroethylene Benzoyl chloride
Ethylenediamine Dichloropropylene Benzonitrile
Zinc chloride Dibutyl phthalate Pentachloroethane
Aluminum chloride Dimethyl ether Boric acid
Ammonium chloride Dimethylsulfoxide Sodium boric acid
Calcium chloride Dimethylformamide Formaldehyde
Ferrous chloride Hydrobromic acid Acetic anhydride
Mercuric chloride Potassium dichromate Methanol
Stannous chloride Bromine Methyl ether
Ferric chloride DI water (Pure water) Methyl ethyl ketone
Cupric chloride Nitric acid Methylene chloride
Sodium chloride Ammonium hydroxide Ethyl butyrate
Magnesium chloride Potassium hydroxide Methyl butyrate
Hydrochloric acid Sodium hydroxide Hydrogen sulfide
Chlorine Soap, detergent Sulphuric acid
Aqua regia Diethyl carbonate Zinc sulfate
Ozone Sodium carbonate Ammonium sulfate
Oleic acid Tetrachloroethane Ferrous sulfate
Perchlorate Tetrachloroethylene Copper sulfate
Hydrogen peroxide Tetrahydrofuran Phosphoric acid
Natrium peroxide Tetrabromoethane Sodium phosphate
Gasoline Triethanolamine
Potassium permanganate Triethylamine
Note) “Chemically inert” means – not to cause any chemical reaction.

448
Series TLM/TILM
Applicable Fluid List
Chemical resistance of Fluoropolymer PFA material

Chemicals in the list below are chemically inert Note) , to PFA material. Possible physical effects may occur such as
penetration and swelling due to temperature, pressure and chemical concentration.
To use PFA tube in a chemical environment, tests should be performed with the same environment to ensure no problem
occurs with operating environment. KQ2
Acetate Butyl stearate Ethylene dicloride Malic acid Salicylic acid KQB2
Acetic anhydride Calcium acetate Ethylene glycol Mercaptan Silicate ester
KS
Acetone Calcium bisulfite Ethylene oxide Mercuric chloride Silicone grease KX
Acetylene Calcium chloride Ethylenediamine Mercury Silicone oil
Acrylonitrile Calcium hydroxide Fatty acid Methyl acetate Silver nitrate KM
Aluminum acetate Calcium hypochlorite Ferric chloride Methyl alcohol Sodium bicarbonate
Aluminum nitrate Calcium nitrate Ferric nitrate Methyl chloride Sodium bisulfate KF
Aluminum bromide Calcium sulfide Ferric sulfate Methyl ethyl ketone Sodium bisulfite
Aluminum chloride Carbon dioxide Fluorboric acid Methyl isobutyl ketone Sodium hypochlorite (5%)
M
Aluminum fluoride Carbon disulfide Fluorobenzene Methyl methacrylate Sodium metaphosphate H/DL
Aluminum sulfate Carbonic acid Fluosilicic acid Methylene dichloride Sodium nitrate L/LL
Ammonia gas Castor oil Formaldehyde Mineral oil Sodium perborate
KC
Ammonium carbonate Caustic soda (30%) Formic acid Monochloroacetic acid Sodium phosphate
Ammonium chloride Cellosolve Furfural Monochlorobenzene Sodium sulfite KK
Ammonium hydroxide Chlorosulfonic acid Gasoline Monoethanolamine Sodium thiosulfate
Ammonium nitrate Chlorotoluene Gelatine Naphtha Soybean oil KK130
Ammonium nitrite Chromic acid Glauber's salt Naphthalene Stannic chloride
Ammonium persulfate Citric acid Glucose Naphthenic acid Stearic acid DM
Ammonium phosphate Coconut oil Glue Natrium peroxide Styrene
Ammonium sulfate Copper cyanide Glycerine Natural gas Sucrose solution KDM
Amyl acetate Copper sulfate Grease Nickel acetate Sulfur
Amyl alcohol Corn oil Hexaldehyde Nickel chloride Sulfur chloride KB
Amyl borate Cottonseed oil Hexane Nickel sulfate Sulfuric acid (98%)
Amyl naphthalene Creosote oil Hexyl alcohol Nitric acid (60%) Sulfurous acid gas KR
Aniline Cresol Hydrobromic acid Nitrobenzene Tannic acid
Aniline dye Cupric chloride Hydrochloric acid Nitroethane Tartaric acid
KA
Animal oil (Lard oil) Cyclohexane Hydrocyanic acid Nitromethane Terpineol
KQG2
Aqua regia Cyclohexanol Hydrofluoric acid (49%) Nitropropane Tetrachloroethane
Arsenic acid Cyclohexanone (Anon) Hydrofluoric acid anhydrous Octyl alcohol Tetraethyl lead
KG
Asphalt Dibutyl phthalate Hydrogen peroxide (30%) Oxalic acid Tetrahydrofuran
Barium chloride Dichlorobenzene Hydrogen sulfide Oxygen Tetralin KFG2
Barium hydroxide Diethyl sebacate Hydroquinone Ozone Thionyl chloride
Barium sulfate Diethylene glycol Hypochlorous acid Palmitic acid Triacetin MS
Barium sulfide Diisopropyl keton Isobutyl alcohol Perchlorate Tributoxy ethyl phosphate
Beer Dioctyl phthalate Isooctane Perchloroethylene Tributyl phosphate KKA
Beet sugar liquors Dioctyl sebacate Isopropyl acetate Petroleum Trichloroethylene
Benzaldehyde Dipentene (Limonene) Isopropyl alcohol Phenol Tricresyl phosphate KP
Benzine Diphenyl Isopropyl ether Phosphoric acid (75%) Triethanolamine
Benzene (Benzol) Diphenyl oxide Kerosene Picric acid Tung oil LQ
Benzyl alcohol Epichlorohydrin Lead acetate Piperidine Turpentine oil
Benzyl benzoate Ethanolamine Lead nitrate Potassium chloride Vegetable oil
MQR
Benzyl chloride Ethyl acetate Lead sulfamate Potassium dichromate Vinegar
Borax Ethyl acetoacetate Linolenic acid Potassium hydroxide Water
T
Boric acid Ethyl acrylate Linseed oil Potassium nitrate Whiskey
Bromine Ethyl alcohol Liquid ammonia Potassium permanganate Xylene
Bunker oil Ethyl benzene LPG (Liquefied petroleum gas) Potassium sulfate Zeolite
Butane Ethyl cellulose Lubricating oil Propyl acetate Zinc acetate
Butter Ethyl chloride Magnesium chloride Propyl alcohol Zinc chloride
Butyl acetate Ethyl oxalate Magnesium hydroxide Propylene Zinc sulfide
Butyl acrylate Ethyl silicate Magnesium sulfate Pyridine
Butyl alcohol (Butanol) Ethylene chlorohydrin Maleic acid Pyrrole
Note) “Chemically inert” means – not to cause any chemical reaction.

449
Series TH/TIH
Applicable Fluid List
Chemical Resistance of Fluoropolymer FEP Material
Chemicals in the list below are chemically inert Note) to FEP material, however physical properties may
be effected by temperature or pressure change.
Please make sure that operating conditions do not cause problems since the use of FEP tubing under
chemical environment is unsecured.

2-nitro-2-methyl propanol Chloroform Nitromethane


2-nitrobutanol Paraffinum liquidum Perchloroethylene
Pentabasic benzamide Allyl acetate Perphloroxylene
N-butylamine Ethyl acetate Unsymmetrical dimethylhydrazine
N-octadecanol Potassium Hydrazine
N-butyl acetate Butyl acetate Pinene
O-cresol Sodium hypochlorite Piperidine
Di-isobutyl adipate Carbon tetrachloride Glacial acetic acid (Acetic acid)
Acetophenone Dioxane Pyridine
Acetone Cyclohexanone Phenol
Alniline Cyclohexane Phthalic acid
Abietic acid Dimethyl ether Dybutyl phthalate
Sulfuric chloride Dimethylsulfoxide Dimethyl phthalate
Isooctane Dimethylformamide Hydrofluoric acid
Liquid ammonia Bromine Naphthalene fluoride
Ethyl alcohol DI water (Pure water) Nitrobenzene fluoride
Ethyl ether Nitric acid Furan
Ethylene glycol Mercury Hexachlorethane
Ethylenediamine Ammonium hydroxide Hexane
Zinc chloride Potassium hydroxide Ethyl hexanoate
Aluminum chloride Sodium hydroxide Phenylcarbinol
Ammonium chloride Cetane Benzaldehyde
Calcium chloride Soap, detergent Benzonitrile
Sulfuric chloride Dibutyl sebacate Borax
Iron chloride (III) Diethyl carbonate Boric acid
Benzoyl chloride Tetrachloroethylene Formic aldehyde (Formalin)
Magnesium chloride Tetrahydrofuran Acrylic anhydride
Hydrochloric acid Tetrabromoethane Acetic anhydride
Chlorine (absolute) Triethanolamine Methacrylic acid
Aqua regia Trichloroethylene Allyl methacrylate
Ozone Trichloroacetic acid Vinyl methacrylate
Hydrogen peroxide Toluene Methyl alcohol
Natrium peroxide Naphtha Methyl ethyl ketone
Gasoline Naphthalene Methylene chloride
Permanganate Naphthol Sulphuric acid
Formic acid Lead Phosphoric acid
Xylene Carbon dioxide Iron phosphate (III)
Chromic acid Nitrogen dioxide Tri-n-butyl phosphate
Chlorosulfonic acid Nitrobenzene Tricresyl phosphate
Note) “Chemically inert” means – not to cause any chemical reaction.
Reference cited: Teflon®, the fluoropolymer handbook, Manual for the chemical applications of Teflon®. Du Pond-Mitsui Fluorochemicals
Co., Ltd.

Teflon® is a registered trademark for the fluoropolymer produced by E.I du Pond de Nemours & Company (Inc.) and Du Pond-Mitsui
Fluorochemicals Co., Ltd.

450
Series TL/TIL/TLM/TILM/TD/TID/TH/TIH
Tubing/Precautions
Be sure to read before handling.

Selection Piping

Warning Caution KQ2


1. Confirm the specifications. 1. Preparation before piping
Products represented in this catalog are designed only for use Before piping is connected, it should be thoroughly blown out
KQB2
in compressed air systems (including vacuum). with air (flushing) or washed to remove chips, cutting oil and KS
Do not operate at pressures or temperatures, etc., beyond the other debris from inside the pipe. Not allowing chips of the KX
range of specifications, as this can cause damage or malfunc- piping thread or the seal material to go in.
tion. (Refer to the specifications.) KM
2. In case of using the product for medical care
This product is designed for use with compressed air system
Air Supply KF
applications for medical care purposes. Do not use in contact
with human bodily fluids, body tissues or transfer applications Warning M
to a human living body.
1. Types of fluid H/DL
This product is designed for use with compressed air. L/LL
Caution 2. In case of excessive condensation
1. Do not use in locations where the connecting Excessive condensation in a compressed air system may
KC
threads and tubing connection will slide or rotate. cause pneumatic equipment to malfunction. Installation of an
The connecting threads and tubing connection will come apart air dryer, water separator before filter is recommended. KK
under these conditions. 3. Drain flushing
2. Use tubing at or above the minimum bending If condensation in the drain bowl is not emptied on a regular KK130
radius. Using below the minimum bending radius basis, the bowl will overflow and allow the condensation to
can cause breakage or flattening of the tubing.
enter the compressed air lines. It causes malfunction of DM
pneumatic devices.
3. Never use the tubing for anything flammable, explo- If the drain bowl is difficult to check and remove, installation of KDM
sive or toxic such as gas, fuel gas, or cooling medi- a drain bowl with an auto drain option is recommended.
ums etc. For compressed air quality, refer to SMC’s “Air Cleaning
Equipment” catalog. KB
Because the contents may penetrate outward.
4. Use the fittings applicable to the tubing size. KR
Operating Environment
Mounting
KA
Warning
KQG2
Caution 1. Do not use in locations having an explosive atmo-
sphere.
1. Confirm model no., size, etc. before installing. KG
Check tubing for damage, gouges, cracks, etc.
2. Do not operate in locations where vibration or
impact occurs. KFG2
[TLM/TILM]
3. In locations near heat sources, block off radiated
The TLM and TILM series do not have the model number
displayed on the product due to the resin material used. If heat. MS
tubing without a model label is mixed with other tubing which
also does not have a model label, it is impossible to identify the KKA
model. Please avoid mixing the products with other models Maintenance
while it is being used and/or stored.
KP
2. When tubing is connected, consider factors such as Caution
changes in the tubing length due to pressure, and 1. Reform periodic inspections to check the following LQ
allow sufficient leeway. problems and replace tubing, if necessary.
3. Do not apply unnecessary forces such as twisting, 1) Cracks, gouges, wearing, corrosion MQR
pulling, moment loads, etc. on fittings or tubing. 2) Air leakage
This will cause damage to fittings and will crush, burst or 3) Twists or crushing of tubing T
release tubing. 4) Hardening, deterioration, softening of tubing
4. Mount so that tubing is not damaged due to tangling 2. Do not repair or patch the replaced tubing or fittings
and abrasion. for reuse.
This can cause flattening, bursting or disconnection of tubing, 3. When using insert or miniature fittings over a long
etc. period, some leakage may occur due to age deterio-
ration of the materials. If any leakage is detected,
correct the problem by additional tightening.
If tightening becomes ineffective, replace the fittings with a
new product immediately.

451
RoHS

Clean Series Tubing


Polyurethane Tubing: Series 10-TU Refer to CAT. E02-23, “SMC Pneumatic Clean Series” for details.

Model/Specifications  — 20 m roll

10 TU0425 BU 20 Inch size


Tubing size

(Series TIUB) Metric size (Series TU)

Color Model 10-TIUB01 10-TU0212 10-TU0425 10-TU0604 10-TU0805 10-TU1065 10-TU1208


Clean series B Black Tubing O.D. (mm) 3.2 2 4 6 8 10 12
Tubing I.D. (mm) 2 1.2 2.5 4 5 6.5 8
W White
R Red Black (B)
BU Blue White (W)
Tubing model Y Yellow Red (R)
G Green Blue (BU)
C Clear Yellow (Y)
YR Orange Green (G)
Clear (C)
Length per roll Orange (YR)
20 20 m roll

Minimum bending radius measuring method Fluid Air/Water


Max. operating pressure (at 20°C) 0.8 MPa
Bend the tube into U-form at
a temperature of 20°C. Fix Burst pressure Refer to the burst pressure characteristics curve.
Fixed end

one end and close loop Recommended fittings Fittings for clean series (10-KJ, 10-KQ, 10-KF, 10-KDM, 10-KG, 10-M, 10-MS)
gradually. Measure 2R when Min. bending radius (mm) Note)
the tube breaks or is 10 4 10 15 20 27 35
crushed. Operating temperature Air: –20 to 60°C, Water: 0 to 40°C (No freezing)
Material Polyurethane
Note) The value of the minimum bending radius is measured at the temperature of 20°C as
shown at the left .

Polyurethane Coil Tubing: Series 10-TCU Refer to CAT. E02-23, “SMC Pneumatic Clean Series” for details.

Specifications
10-TCU 10-TCU 10-TCU 10-TCU 10-TCU 10-TCU 10-TCU
Model 0425B-1 0425B-2 0425B-3 0604B-1 0604B-2 0604B-3 0805B-1
No. of cores 1 core 2 cores 3 cores 1 core 2 cores 3 cores 1 core
Tubing O.D. (mm) 4 6 8
Tubing I.D. (mm) 2.5 4 5
Fluid Air
Max. operating pressure (at 20°C) 0.8 MPa
Burst pressure Refer to the burst pressure characteristics curve.
Recommended fittings Fittings for clean series (10-KJ, 10-KQ, 10-KF, 10-KDM, 10-KG, 10-M, 10-MS)
Operating temperature –20 to 60°C
Material Polyurethane
Color Black

Polyurethane Flat Tubing: Series 10-TFU Refer to CAT. E02-23, “SMC Pneumatic Clean Series” for details.

Burst Pressure Characteristics Specifications


Curve and Operating Pressure Model
10-TFU 10-TFU 10-TFU 10-TFU 10-TFU 10-TFU
0425B-2 0425B-3 0604B-2 0604B-3 0805B-2 0805B-3
No. of cores 2 cores 3 cores 2 cores
2 cores 3 cores
3 cores
Tubing O.D. (mm) 4 6 8
Tubing I.D. (mm) 2.5 4 5
Fluid Air
Burst pressure (MPa)

Max .operating pressure (at 20°C) 0.8 MPa


Bu
rst Burst pressure Refer to the burst pressure characteristics curve.
pre
ssu Recommended fittings Fittings for clean series (10-KJ, 10-KQ, 10-KF, 10-KDM, 10-KG, 10-M, 10-MS)
re
Operating temperature –20 to 60°C
Material Polyurethane
Color Black
Max. oper Min. bending radius (mm)
ating pres 10 15 20
sure
Tubing roll length (m) 10
Note) The value of the minimum bending radius is measured at the temperature of 20°C as
shown at the left .

Operating temperature (°C)

452
Clean Tubing:
Polyolefin Tubing

Series TPH RoHS

KQ2
Model/Specifications — 20 m roll  — 100 m reel
KQB2
KS
Model TPH0425 TPH0604 TPH0806 TPH1075 TPH1209 KX
O.D. (mm) 4 6 8 10 12
I.D. (mm) 2.5 4 6 7.5 9 KM
KF
White (W)
Black (B) M
Red (R) H/DL
Blue (BU) L/LL
Yellow (Y) KC
Green (G)
KK
Fluid Air/Nitrogen gas/Water (Pure water) (1) KK130
Max. operating
pressure (at 20°C) 1.0 MPa (2) 0.7 MPa (2)
DM
Min. bending radius (mm) 15 25 35 45 55
Burst pressure Refer to the burst pressure characteristics curve.
KDM
Clean one-touch fittings KB
Applicable fittings One-touch fittings, Metal: Series KQB2
One-touch fittings, Stainless steel 316: Series KQG2 KR
Insert fittings
Operating temperature – 20 to 80°C, For water 5 to 80°C KA
Material Polyolefin resin
Note 1) Please consult with SMC regarding other fluids. KQG2
Note 2) The maximum operating pressure is the value at 20°C. Refer to the burst pressure
characteristics curve for other temperatures. Furthermore, an abnormal temperature rise KG
due to adiabatic compression can cause tubing to burst.
Note 3) The minimum bending radius indicates the value at a temperature of 20°C with an
outside diameter rate of change of 10% or less. At higher temperatures the outside KFG2
diameter rate of change may exceed 10% within the minimum bending radius.
Note 4) Polyolefin resin is not suitable for regular pneumatic equipment piping because it is not
resistant to mineral oil. MS
KKA
Burst Pressure Characteristics How to Order
Curve and Operating Pressure KP
5
TPH0604 B 20 LQ
MQR
Bu H0

4
Burst pressure (MPa)

Bu H0

TP
rs 42

Tubing model
TP
rs 80

tp
t p 6,

re 5,T

T
re TP

ss P
ss H1

ur H0

3 Color Length per roll


ur 07

e
e

Symbol Color Symbol Length


5

6
,TP

04

2 W White 20 20 m roll
H1

Max. operating pressure B


20

Black 100 100 m reel


9

(TPH0425,TPH0604)
1 R Red
Max. operating pressure BU Blue
(TPH0806,TPH1075,TPH1209) Y Yellow
0
-20 0 20 40 60 80 G Green
Operating temperature (°C)

453
Clean Tubing:
Soft Polyolefin Tubing

Series TPS RoHS

Model/Specifications — 20 m roll  — 100 m reel

Model TPS0425 TPS0604 TPS0805 TPS1065 TPS1208


O.D. (mm) 4 6 8 10 12
I.D. (mm) 2.5 4 5 6.5 8

White (W)
Black (B)
Red (R)
Blue (BU)
Yellow (Y)
Green (G)

Fluid Air/Nitrogen gas/Water (Pure water) (1)


Max. operating
pressure (at 20°C) 0.7 MPa (2)

Min. bending radius (mm) 10 20 25 30 40


Burst pressure Refer to the burst pressure characteristics curve.

Clean one-touch fittings


Applicable fittings One-touch fittings, Metal: Series KQB2
One-touch fittings, Stainless steel 316: Series KQG2
Insert fittings
Operating temperature – 20 to 80°C, For water 5 to 80°C
Material Polyolefin resin
Note 1) Please consult with SMC regarding other fluids.
Note 2) The maximum operating pressure is the value at 20°C. Refer to the burst pressure
characteristics curve for other temperatures. Furthermore, an abnormal temperature rise
due to adiabatic compression can cause tubing to burst.
Note 3) The minimum bending radius indicates the value at a temperature of 20°C with an
outside diameter rate of change of 10% or less. At higher temperatures the outside
diameter rate of change may exceed 10% within the minimum bending radius.
Note 4) Polyolefin resin is not suitable for regular pneumatic equipment piping because it is not
resistant to mineral oil.

Burst Pressure Characteristics How to Order


Curve and Operating Pressure
5
TPS0604 B 20
4
Tubing model
Burst pressure (MPa)

3 Bu Color Length per roll


rs
tp
re Symbol Color Symbol Length
ss
2 ur W White 20 20 m roll
e
B Black 100 100 m reel
1 Max. operating pressure R Red
BU Blue
0 Y Yellow
-20 0 20 40 60 80 G Green
Operating temperature (°C)

454