PROJECT PROPOSED SOLAR PLANT Of ______CAPACITY , at __________Location BOQ Numbe r : DATE

SUBJECT BILL OF QUANTITIES - ____________________ REVISON T0


ERECTION
SL.NO DESCRIPTION OF WORK QUANTITY UNIT SUPPLY RATE SUPPLY AMOUNT ERECTION RATE REMARKS
AMOUNT

1.0 SOLAR PV CELLS of _____Wp , Type ___________

Supply, installation and interconnection of 72 Cell Dual Glass 3.2 MM thick Solar Pv module
___________ /________ Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating
with Power output Capacity of each solar PV module >300W. Total Solar PV module arrays Capacity a
set of (____nos x _____Wp) at _______. The Solar Panels should Comply as per IEC 61215 and IEC
1.10 R.only Each 0.00 0.00
61730 standard. DC cable/wire of suitable size up to _____Mt/solar pv module with solar pv
connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be
equal or more than _____%.

2.0 MMS -- Module Mounting Strucutre

Support array/module mounting structures, mounting Clips shall be manufactured with Hot dip
galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of _______
microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS
having adequate strength & appropriate design and shall be suitable to accommodate ________ No. of
2.1 Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with R.only Kg 0.00 0.00

civil work removable concrete ballast made of pre-fabricated PCC (1:2:4) M15 and other required
hardware. All solar panels must be accessible from the top for cleaning and from the bottom for
access to the module junction box.

Structure supply and Installation-______Wpmodule at 22 degree tilt and 7m pitch,


2.2 consideringstructure length _____m, width ______m(accommodating 40 modules on one R.only Kg 0.00 0.00
structure,____*______ matrix). With 6 Nos of Posts. (Total _____ no.of Tables & ______ Kg/Table)

Piling for MMS structure-Consider ______mm Diameter Pile Foundation.Total ____ nos of Table& _____
2.3 Nos of Posts per Table. R.only Cum 0.00 0.00

3.0 Inverter & Combiner Boxes

Supply , Installion and commissioning of MPPT Based Grid Tied Solar Inverter with ____kVA/_____kW
rating with maximum DC Input Voltage 1000V , MPPT range from 400V to 800V AC output 415V, 3
Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC &
AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per
VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output
3.1 R.only Nos 0.00 0.00
power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours
etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-
11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure
should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more
than 96%.

Supply , Installion and commissioning of Central Inverter with ____kVA @50 C/_____kW rating with
maximum DC Input Voltage ______V ,Grid output 535~660V, 3 Phase, 50Hz, with inbuilt
protection of AC high/low voltage, high/low frequency with Output Current _______@40 C, DC
Input Protection Load Breaks switch with Fuse of Size _______ ,AC Input side LSING Protection
______Amp ,DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding
3.2 protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like R.only Nos 0.00 0.00
output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency,
operation hours etc. complying to standards as per IEC 62116, IEC 61727, IEC 61683, IEC
60068(1,2,14,30), IEC 62109-1/2. EMC Compliances : EN 61000-6-1, EN 61000-6-2 Invertor has
facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for
Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%.
Supply & installation of DC combiner box/Array Junction Box made out of the thermoplastic IP65
protected DIN rail mounting type of following size for interconnection of DC cable of the solar
3.3
module arrays & DC outgoing cable to DC distribution box complete with termination with cu
lugs/ferrule /connectors (MC4) and fixing accessories as required.

3.3.1 4 way 16A connector with 4 nos 16A SP DC MCB 10kA with enclosure R.only Nos 0.00 0.00

3.3.2 6 way 16A connector with 6 nos 16A SP DC MCB 10kA with enclosure R.only Nos 0.00 0.00

3.3.3 8 way 16A connector with 8 nos 16A SP DC MCB 10kA with enclosure R.only Nos 0.00 0.00

Supply & installation of AC distribution box made out of the thermoplastic IP65 protected DIN rail
mounting and front lid transparent type of following size with Phase indication LED lamp, busbar,
3.4 earth link terminal etc. complete with all fixing accessories as required. ELR & CBCT of Necessary
Incomer Current rating, for MCCB > 250 Amp . Metering is required 0.5s class with SECURE Elite
30B.

3.4.1 63A 4P AC MCB 16kA with enclosure R.only Nos 0.00 0.00

3.4.2 125A 4P AC MCB 16kA with enclosure R.only Nos 0.00 0.00

3.4.3 250A 4P AC MCB ___kA with ____ Outgoing of _____rated Amp capacity enclosure of IP ____ R.only Nos 0.00 0.00

3.4.3 400A 4P AC MCB ___kA with ____ Outgoing of _____rated Amp Capacity enclosure of IP ____ R.only Nos 0.00 0.00

3.4.4 630A 4P AC MCB ____kA with ____ Outgoing of _____rated Amp Capacity enclosure of IP _____ R.only Nos 0.00 0.00

Supplying and laying of following sizes of XLPE insulated and sheathed, UV stablished/protected Single
core flexible copper conductor DC cable layed in existing PVC/HDPE conduit pipe suitable for outdoor
3.5 installation complete with termination with tinned copper end-ferrules, special connector (MC4), gland
etc. as required. All DC cable shall be supplied confirming to IEC 60502 / IS 1554 voltage rating 1500 V
grade.

3.5.1 25 sqm. single core flexible Copper UV protected XLPE cable. R.only RM 0.00 0.00

3.5.2 16 sqm. single core flexible Copper UV protected XLPE cable. R.only RM 0.00 0.00

3.5.3 10 sqm. single core flexible Copper UV protected XLPE cable. R.only RM 0.00 0.00

3.5.4 6 sqm. single core flexible Copper UV protected XLPE cable. R.only RM 0.00 0.00

Supply and fixing of following sizes of heavy duty PVC/HDPE conduit pipe along with all accessories like
bend, JB, thermo plastic clamp/saddle, pvc slip, screws etc. fixed on surface /recessed in
3.6
wall/ceiling, complete with cutting the wall and making good the same in case of recessed conduit as
required.

3.6.1 32mm heavy duty PVC/HDPE conduit pipe. R.only RM 0.00 0.00

3.6.2 20mm heavy duty PVC/HDPE conduit pipe. R.only RM 0.00 0.00

3.6.3 25mm heavy duty PVC/HDPE conduit pipe. R.only RM 0.00 0.00
5.0 11KV Metering Cubical OUTDOOR IP54
Supply, fabricate & Installation of metering cubicle with TVM METER 0.2S CLASS Accurancy, ABT & TOD
FA CILITY house inisde IP 55 enlcosure, PROVISION FOR CHECK METER & panel mounted 3NO.S CT's &
PT's (at __________ authorised fabricator) to the requirement of __________. Calibrate at
__________ RT Division, erection, testing & commissioning at site in the presence of __________ RT
5.1 Division personnel. The quoted rate shall be inclusive of CTs , PTs , Bus Bars, etc., and shall also R.only Each 0.00 0.00
include all other accessories complete as required. AS PER __________ STATUTORY NORMS AND
REQUIREMENTS. THIS METER CUBICLE SHALL BE ALSO SUITA BLE FOR NET METERING APPLICATION.
(As per tender dwg - __________-EL-SLD-401 , Rev : T0 )

6.0 11kV COMPACT RING MAIN VCB PANEL-1 Outdoor IP 54

Supply, store, receiving, unloading at site, erecting, testing and commissioning of 11 kV, 3Phase, 50
Hz, 500 MVA , THREE VCB Panel of Outdoor type, totally enclosed free standing MS sheet clad cubicle
type, Isolation type, HT Panel of siemens grey or of approved color with 1no.800A motorised VCB as
incomer,800A TP PVC sleeved copper bus bars and 2no.400A motorised VCB as OUTGOING suitable to
receive 3C x300 Sqmm XLPE(E) HT incomig cable and 3C x 300Sqmm XLPE(E) HT outgoing cable. The
6.10 1.00 Each 0.00 0.00
VCB Panel shall comply to the requirements of __________. The tripping mechanism shall be suitable
for 110V DC source in built power pack & 230V AC source for spring charge & heater circuit from
external supply . AS PER __________ STATUTORY NORMS AND REQUIREMENTS.
(As per tender dwg - __________-EL-SLD-401 , Rev : T0 )

7.0 PACKAGED SUBSTATION-1 IP54- 630KVA WITH ONAN TRAFO

Supply , Installation, Testing and Commissioning of 11kV/433V , 630KVA PSS 3Ph. 50Hz. WITH HT ICOG
panel , 630KVA, 11kv/433 volts transformer,LT connection and LT panel enclosed detailed
7.1 specifications.AS PER __________ STATUTORY NORMS AND REQUIREMENTS. 1.00 Each 0.00 0.00

(As per tender dwg - __________-EL-SLD-401 , Rev : T0 )

SECTION-1 HT VCB ICOG PANEL


Supply, store, receiving, unloading at site, erecting, testing and commissioning of 11 kV, 3Phase, 50
Hz, 500 MVA , 400A, VCB PA NEL of indoor type, totally enclosed free standing MS sheet clad cubicle
type, Isolation type, HT Panel of siemens grey or of approved color with 1no.400A 3P 21.1KA VCB as
incomer cum outgoing ICOG panel along 400A TP PVC sleeved copper bus bars suitable to receive 3C x
240 Sqmm XLPE(E) HT incomig cable and 3C x 240 qmm XLPE(E) HT outgoing cable. The VCB Panel shall
7.2 0.00 0.00
comply to the requirements of __________. The tripping mechanism shall be suitable for 110V DC
source in built power pack & 230V AC source for spring charge & heater circuit from external supply .
AS PER __________ STATUTORY NORMS AND REQUIREMENTS.
(As per tender dwg - __________-EL-SLD-401 , Rev : T0 )

SECTION-2 OIL TYPE SEALED HAEMETRICALLY TRAFO


Supply , unloading at site, store, Erection, testing & commissioning of 630kVA , 11KV/433V, 35MVA ,
Dyn 11, Oil cooled ONAN type indoor mounting Copper wound Distribution Transformer with OFF load
tap changer (OCTC) , Marshalling Box, Oil Temperature Indicator, Winding Temperature Indicator,
Buccholz Relay, Bidirectional rollers, Marshalling Box, cable box with HT Disconnecting Chamber for 3C
7.3 0.00 0.00
x240 Sq.mm 11KV, XLPE(E) Al. Cable and LT bushing for copper busbar connection with all other
accessories completely as required. The tap off on the HT side shall be +5% - 5% .AS PER IS 1180 LEVEL
2 ENERGY EFFICIENCY.
(As per tender dwg - __________-EL-SLD-401 , Rev : T0 )
11.0 H.T.Cable Outdoor/Indoor end termination

Supply & termination of Raychem type end termination kit suitable for the above XLPE cables.

A 3-Core x 300 Sqmm11KV XLPE Cable termination(OUTDOOR) R.only Each 0.00 0.00
B 3-Core x 300 Sqmm 11KV XLPE Cable termination(INDOOR) 4.00 Each 0.00 0.00
C 3-Core x 185 Sqmm11KV XLPE Cable termination(OUTDOOR) R.only Each 0.00 0.00
D 3-Core x 185 Sqmm 11KV XLPE Cable termination(INDOOR) 8.00 Each 0.00 0.00

12.0 EARTHING
Providing the earth stations with necessary materials labour,civil works such as construction of 450 x
450 chamber with GI cover, etc.,complete as required and as per IS-3043.complete.
3 mtrs long 100 mm dia. C.I pipe electrode earth station.The chamber size shall be 600 x 600 mm with
A heavy duty C.I. Cover plate. The identification number shall be provided both inside and outside. As 16.00 set 0.00 0.00
per IS 3043.
600 x 600 x 3.15 mm copper plate electrode earth station along with 2 runs of 3mtrs long 35x6 mm
B Copper strip .The chamber size shall be 600x 600 mm with C.I. Cover plate. The identification number 4.00 set 0.00 0.00
shall be provided both inside and outside of equipment. As per IS 3043.
The type of electrode to be used shall be of 17.2mm dia solid steel core with Cu coated as per UL467
of 3Mtrs length with 3 bags of (25 Kg each )of Back fill compound (BFC). The rate shall include all
C necessary material required. The chamber size shall be 600 x 600 mm with heavy duty C.I. Cover R.only set 0.00 0.00
plate.

Supply Install of chemical type earth pit with 3 bags of Backfill compound containing 25 Kgs each,
Black Cotton soil, installation with 2runs of 3mtr long 30 x 10 mm copper flat with 600mm x 600mm x
3.15mm copper plate at bottom and heavy checked plate Chamber constructions . Testing and
D commissioning the eathing with 3 bags of (25 Kg each )of Back fill compound (BFC). The rate shall R.only set 0.00 0.00
include all necessary material required. The chamber size shall be 600 x 600 mm with heavy duty C.I.
Cover plate.

13.00 EARTHING TAPES/WIRES

Supply of earth tapes/wires as per specification, complete. Erection rate shall be both indoor &
outdoor inclusive of earth excavation work.
A 50 x 10 mm Hot Dip Galvanised Iron Tape R.only Mtrs 0.00 0.00
B 50 x 6 mm Hot Dip Galvanised Iron Tape R.only Mtrs 0.00 0.00
C 65 x 10 mm Copper Tape with Black PVC sleeves R.only Mtrs 0.00 0.00
D 50x 10 mm Copper Tape with Black PVC sleeves R.only Mtrs 0.00 0.00
E 35 x 6 mm Hot Dip Galvanised Iron Tape R.only Mtrs 0.00 0.00
F 25 x 6 mm Hot Dip Galvanised Iron Tape R.only Mtrs 0.00 0.00
G 40 x 10 mm Copper Tape with Black PVC sleeves R.only Mtrs 0.00 0.00
H 25 x 6 mm Copper Tape with Black PVC sleeves R.only Mtrs 0.00 0.00
14.0 EXTERNAL TRENCH AND HUME / GI PIPE

PIPES :

Supply and laying of pipes in excavated ground including excavation laying and making good the surface as
required. Any collars and bends and nipples required shall be laid at a depth of 600 mm below ground level
or under paved areas/under floor as required.

A 150 mm dia Class 'B' GI pipe. R.only Mtr 0.00 0.00


B 150 mm dia HDPE PIPE R.only Mtr 0.00 0.00
C 150 mm dia Hume pipe. R.only Mtr 0.00 0.00
D HT cable markers R.only Each 0.00 0.00
E LT cable markers R.only Each 0.00 0.00

15.00 Civil works for external cable laying


Preparation of outdoor cable trenches including excavation,back filling,sand filling,cable
tiles,compaction as per specification of the for the following sizes.
A Trench of width 1000mm & depth 1000mm. R.only Mtr 0.00 0.00
B Trench of width 450mm & depth 300mm. R.only Mtr 0.00 0.00
C Trench of width 300mm & depth 300mm. R.only Mtr 0.00 0.00
D Trench of width 150mm & depth 600mm. 50.00 Mtr 0.00 0.00
E Trench of width 450mm & depth 600mm. R.only Mtr 0.00 0.00
F Trench of width 300mm & depth 600mm. R.only Mtr 0.00 0.00

16.00 MISCELLANEOUS ITEMS :


A 4 Fire buckets of 9 Ltrs capacity with floor, stand, sand, painting, etc. 2.00 Each 0.00 0.00

Rubber mats of 1.1 KV grade 1.8 Mtrs x 0.9 Mtrs and of MIN. 3MM thickness & BLUE IN COLOUR as
B 30.00 Each 0.00 0.00
required by the Electrical Inspectorate and confirming IS code -15652- edition 2006 .

C Shock treatment chart with teak wood frame and glass cover as approved by Electrical Inspectorate. 1.00 Each 0.00 0.00

D Electrical single line diagram A1 SHEET (As Built drawing) with teak wood frame and glass cover. 1.00 Each 0.00 0.00

E First Aid Box. 2.00 Set 0.00 0.00

Danger boards mention voltage level in min three languages marked in red as per __________
F 10.00 Each 0.00 0.00
requirements.

17.00 Yard Fencing & Jelly Spreading

Providing 2500 mm high chain link fencing consisting of 50 x 50 x 6 mm MS angle, vertical support port
2500 mm high (spacing not exceeding 3.0m), 50 x 50 x 6 mm MS angle 2800 mm long bracing struts (in
both directions) for every fifth post (and at change of directions of the fence) and 10 gauge GI chain
link mesh 50 x 50 mm fully streached and secured to MS angle verticals and horizontals with 6mm dia
MS bolts, nuts and washers spaced at 150 mm (min) using 25 x 5 mm MS flat cover strips, 170 mm
A 20.00 Sqmt 0.00 0.00
long, bottom 75mm end of MS verticals and bracing struts to be split and 400 mm embedded in 400 x
400 x 500 deep cement concrete 1:3:6 including necessary welding and/or bolted connections of MS
horizontals and bracings/struts to vertical posts, excavation, cement concrete and painting one coat
of primer and two coats of synthetic enamel paint to all exposed faces of steel work and chain link
fencing. Measured nett area of fencing between external faces of horizontal members.

providing one gate 2400 mm wide (min) in two (side hung) leaves to match the chain link fence
B 1.00 Each 0.00 0.00
including necessary hinges, locking arrangements, etc., complete.

providing one gate 1200 mm wide (min) in two (side hung) leaves to match the chain link fence
C 1.00 Each 0.00 0.00
including necessary hinges, locking arrangements, etc., complete.

Supplying and spreading 40mm nominal size stone aggregate as directed (voids not considered for
D 5.00 cum 0.00 0.00
measurement)
30.0 POWER AND CONTROL CABLES :

Supply, Laying and testing of 1.1KV Grade XLPE insulated, PVC sheathed Aluminium conductor steel
armoured power cables as per the specs. The rates quoted shall be for laying in trays, cable trenches
(indoor and outdoor), pipes, etc. For buried cables,the excavation work will be included under the
heading "Civil works for outdoor cable laying." AS PER IS 7098

A 3.5 Core x 300 Sqmm A2XFY CABLE R.only Mtr 0.00 0.00

B 3.5 Core x 240 Sqmm A2XFY CABLE 300.00 Mtr 0.00 0.00

C 3.5 Core x 185 Sqmm A2XFY CABLE R.only Mtr 0.00 0.00

D 3.5 Core x 95 Sqmm A2XFY CABLE 100.00 Mtr 0.00 0.00

E 3.5 Core x 70 Sqmm A2XFY CABLE R.only Mtr 0.00 0.00

F 3.5 Core x 50 Sqmm A2XFY CABLE R.only Mtr 0.00 0.00

G 3.5 Core x 35 Sqmm A2XFY CABLE R.only Mtr 0.00 0.00

H 4 Core x 25 Sqmm A2XFY CABLE 25.00 Mtr 0.00 0.00

I 4 Core x 16 Sqmm A2XFY CABLE 25.00 Mtr 0.00 0.00

J 4 Core x 10 Sqmm A2XWY CABLE R.only Mtr 0.00 0.00

Supply, Laying and testing of 1.1KV Grade PVC insulated, PVC sheathed Copper conductor steel
armoured power cables as per the specs. The rates quoted shall be for laying in trays, cable trenches
(indoor and outdoor), pipes, etc. For buried cables, the excavation work will be included under the
heading "Civil works for outdoor cable laying." AS PER IS 1554

A 1 Core x 185 Sqmm YY Cable . 100.00 Mtr 0.00 0.00

B 3 Core x 2.5 Sqmm 2XWY Cable . 25.00 Mtr 0.00 0.00

C 3 Core x 1.5 Sqmm 2XWY Cable . 50.00 Mtr 0.00 0.00

D 3 Core x 1.5 Sqmm YY Cable . 25.00 Mtr 0.00 0.00

E 24 Core x 2.5 Sqmm 2XWY Cable . R.only Mtr 0.00 0.00

F 19 Core x 2.5 Sqmm 2XWY Cable . R.only Mtr 0.00 0.00

G 12Core x 2.5 Sqmm 2XWY Cable . R.only Mtr 0.00 0.00

H 7Core x 2.5 Sqmm 2XWY Cable . 100.00 Mtr 0.00 0.00

31.00 CIVIL WORKS FOR OUTDOOR CABLE LAYING :


Preparation of outdoor cable trenches including excavation, back filling, sand filling, cable tiles,
compaction as per specification, of the following sizes.
A Trench of width 600mm & depth 750mm. R.only Mtr 0.00 0.00
B Trench of width 300mm & depth 450mm R.only Mtr 0.00 0.00
A Trench of width 150mm & depth 750mm. R.only Mtr 0.00 0.00
B Trench of width 400mm & depth 450mm R.only Mtr 0.00 0.00
32.00 CABLE END TERMINATIONS :

Supplying and providing the end terminations with Aluminium cable lugs, Double compression brass
cable glands, taping, crimping, gland and armour earthing, etc. complete as required.

A 3.5 Core x 300 Sqmm A2XFY CABLE R.only EACH 0.00 0.00

B 3.5 Core x 240 Sqmm A2XFY CABLE 14.00 EACH 0.00 0.00

C 3.5 Core x 185 Sqmm A2XFY CABLE R.only EACH 0.00 0.00

D 3.5 Core x 95 Sqmm A2XFY CABLE 6.00 EACH 0.00 0.00

E 3.5 Core x 70 Sqmm A2XFY CABLE R.only EACH 0.00 0.00

F 3.5 Core x 50 Sqmm A2XFY CABLE R.only EACH 0.00 0.00

G 3.5 Core x 35 Sqmm A2XFY CABLE R.only EACH 0.00 0.00

H 4 Core x 25 Sqmm A2XFY CABLE 4.00 EACH 0.00 0.00

I 4 Core x 16 Sqmm A2XFY CABLE 4.00 EACH 0.00 0.00

J 4 Core x 10 Sqmm A2XWY CABLE R.only EACH 0.00 0.00

Supplying and providing the end terminations with Copper cable lugs, Double compression brass cable
33.00 glands, taping, crimping, gland and armour earthing, etc. complete as required.

A 1 Core x 185 Sqmm YY Cable . 46.00 EACH 0.00 0.00

B 3 Core x 2.5 Sqmm 2XWY Cable . 10.00 EACH 0.00 0.00

C 3 Core x 1.5 Sqmm 2XWY Cable . 10.00 EACH 0.00 0.00

D 3 Core x 1.5 Sqmm YY Cable . 10.00 EACH 0.00 0.00

E 24 Core x 2.5 Sqmm 2XWY Cable . R.only EACH 0.00 0.00

F 19 Core x 2.5 Sqmm 2XWY Cable . R.only EACH 0.00 0.00

G 12Core x 2.5 Sqmm 2XWY Cable . R.only EACH 0.00 0.00

H 7Core x 2.5 Sqmm 2XWY Cable . 4.00 EACH 0.00 0.00


37.00 STEEL ITEMS :
Supply, fabrication, erection painting of steel items as required as per specification complete.
Generally steel items include cable trays and supporting arrangements and any other steel items not 0.50 M.T. 0.00 0.00
covered in other items of schedule of quantities.

38.00 GI LADDER HOT DIPPED TYPE CABLE TRAYS


Supply & erection of the following sizes ladder type cable tray made of 14/16 SWG hot dipped
galvanised with necessar grip bolts,nuts, etc.,complete as required.

A 75X75X1000 mm wide,2mm thick with 2 runs of 50x 6mm GI strip along tray . R.only Mtr 0.00 0.00

B 75X75X750 mm wide,2mm thick with 2 runs of 40x 6mm GI strip along tray . 50.00 Mtr 0.00 0.00

C 75X75X600 mm wide ,2mm thick with 2 runs of 40x 6mm GI strip along tray . R.only Mtr 0.00 0.00

D 75X75X450 mm wide ,2mm thick with 2 runs of 25x 6mm GI strip along tray . R.only Mtr 0.00 0.00

E 50X50X300 mm wide ,2mm thick with 2 runs of 25x 3mm GI strip along tray . R.only Mtr 0.00 0.00

F 50X50X150 mm wide ,2mm thick with 2 runs of 25x 3mm GI strip along tray . 25.00 Mtr 0.00 0.00

39.00 PRE GALVANISED PERFORATED GI CABLE TRAYS :


Supply & erection of the following sizes pre galvanised perforated type cable tray made of 14 SWGGI
trays with necessary bolts, nuts,double washers, etc., complete, necessary supports, brackets, angle
iron,suspension are measured separately under the heading "Steel Item".(THE RATE SHALL ALSO
INCLUDE TOP COVER)

A 300 mm wide x 75mm depth with 2 runs of 25x 3mm GI strip along tray with top cover R.only Mtr 0.00 0.00

B 150 mm wide x 75mm depth with 2 runs of 25x 3mm GI strip along tray with top cover . R.only Mtr 0.00 0.00

C 100 mm wide x 75mm depth with 2 runs of 25x 3mm GI strip along tray with top cover . R.only Mtr 0.00 0.00

D 50 mm wide x 50mm depth with 2 runs of 10sqmm Copper MSCC WIRE along tray with top cover . R.only Mtr 0.00 0.00
40.00 HDD METHOD FOR HT/LT CABLES
Providing Horizontal Directional Drilling for Laying HDPE Pipe of 200mm dia. layout / routing as per
drawings at 2.50 m below existing Ground Level.
A Rate to include Pilot Bore / Drilling, pushing and rotating by long high tensile flexible drill rods as per R.only Mtr 0.00 0.00
required Size Proposed HDPE Pipe with necessary Equipment, drilling head, Tools & Tackles,
Consumables etc., Complete.

Providing and Laying HDPE Pipe of PN -8 of 200 mm dia. Inside Horizontal Directional Drilled Bore with
B R.only Mtr 0.00 0.00
necessary welded Joints etc., complete.
27.0 Utility Development & Civil Works

Clearing grass, removal of the rubbish,roots or any kind of dumped material within the construction premise required to
start the project and disposal of same aout of site peripheri, complete

Earth work in excavation including back filling by mechanical means (Hydraulic excavator) or manual, over the area ( not
exceeding 1.5 in depth,and 10 sqm on plan) and disposal of surplus excavated earth, lead up to 50m and lift up to 1.5m,
disposed earth to be levelled and neatly dressed(excavation shall be measured according to neat line for measurement )

Construction of Control room & INVERTER ROOM of SIZE (____X ____M) & ( ____X ___M) as per the
Architechural Drawing

PCC Work :Providing and laying in position cement concrete of specified grade including the cost of centerin g and
shuttering .
A 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size). R.only Cum 0.00 0.00
B 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) R.only Cum 0.00 0.00
C 1:4:8 (1 Cement : 4 coarse sand : 6 graded stone aggregate 40 mm nominal size). R.only Cum 0.00 0.00
D 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). R.only Cum 0.00 0.00

RCC Work : Providing and laying in position design mix concrete of specified grade forreinforced cement concrete work
including pumping of concrete to site of laying including the cost of centering, shuttering, finishing and reinforcement
including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve
workability without impairing strength and durability as per direction of Engineer-in-charge

A M25 GRADE R.only Cum 0.00 0.00


B M20 GRADE R.only Cum 0.00 0.00
C M15 GRADE R.only Cum 0.00 0.00

REINFORCEMENT :Receiving , storing , stacking and placing reinforcement steel in all reinforced concrete work
including straightening , cutting , removal of loose rust by wire brush , bending , binding , placing in position to the shape
and profilerequired at all levels and heights as per drawing and design and /or as directed by Enigineer-in-charge , binding
with 18 gauge SWG annealed steel wire including cost of binding wire etc. complete. ( contractor has to arrange the
annealed steel wire at his own cost.)

A HYSD bars of grade Fe 500 bars R.only KG 0.00 0.00

Brickwork : Providing and laying brick work with bricks of class 75 in half brick thick joints finished flush/raked to 12 mm
R.only Sqm 0.00 0.00
depth, cured including necessary scaffoldig complete in cement mortar 1:4 with coarse sand

External Plaster :Providing 15-18mm thick average cement plaster in two coats to rough surface of walls, columns,
R.only Sqm 0.00 0.00
piers etc., applied, finished smooth and cured, complete in cement mortar 1:6 ( 1 cement : 6 fine sand )

Internal Plaster :Providing 12-15mm thick average cement plaster to smooth surface of walls, columns, piers etc.,
applied, finished smooth and cured, complete,with mixes : 1:6 with coarse sand. R.only Sqm 0.00 0.00

Water Proofing :Providing and laying water proofing treatment in floors and at walls upto 1m by applying geo textile
sheet asper company rules. The vendors will have to furnish gaurantee of waterproofing upto 10 years R.only Sqm 0.00 0.00

Painting:Painting three or more coat of Oil bound distemper on interior surface including the base cement primer and
R.only Sqm 0.00 0.00
smothening of the surface by BIRLA / JK putty complete as per instructions of Architect.
False Ceiling : P&F in position Gypsum board false ceiling with 12.5mm th. Gypsum boards,screwed/ fixed to the
under struct of suspended G.I. Grid const & suspended from the main ceiling of ceiling sectn at max c to c distance of
450 mm perimeter channel and intermediate channels at max c to c distance 1200 mm galvanised grid should be fixed R.only Sqm 0.00 0
to RF CC slab.The gypsum board should be fixed to galvanised iron grid with necessary screws.The boards should be
taped and filled from underside to give smooth, seamless ceiling.The rate should include necessary additional ceiling
sections and intermediate channels to be provided at openings for light fixtures, asbestos cement ducts, vertical drops,
offsets etc. Additional intermediate channels should be fixedto strap hangers for additional support to prevent strapping
at every 1200 mm item to be comp in all respect.(G.I. perimeter channel size- 27mmx0.5mm &30mm,intermediate
channel. size- thk.,flange-20mm

False Ceiling : With Armstrong Orcal Lay in metal ceiling System consisting of 600x600mm Lay
in tiles of pre coated galvanised steel in 0.5/0.4 mm thickness in white colour with standard
perforation of 2.5mm dia & open area of 16%. The back of the tile should have black acoustical R.only Sqm 0.00 0
fleece with NRC of 0.70 & CAC 36 with life time warrantee against sag in module size 595 mm X
595 mm at required height above FFL.

Periphery Road - Proving & laying 150mm ThickLayer of Rubble for preparation of base &Spreading Rolling,
B Compaction, Watering, etc.Complete & Finishing it With A Layer Of 25mmThk. Bitumunious Road. (4m Width R.only Each 0.00 0
Assumed),2886total length of periphery road

Supply & Installation of Porta Cabin of Size (_____X_____) Tw o inner walls of porta-cabin are made in aluminum
framed section partition as per attached drawings. 600x600mm grid type false ceiling with mineral fiber material
C with rock wool insulation at the top as false ceiling in office passages. [Make: Armstrong or equivalent] R.only Each 0.00 0
Necessary space to accommodate electrical and A C (cassetteindoor unit )

Insulation LShould be filled in between the exterior and interior wall. It should
be of Rock wool/mineral Wool having excellent thermal efficiency
and acoustic performance of at least 50mm average thickness
confining to IS; which will be rot proof, fire retardant, nonhygroscopic and vermin proof.
The doors should be insulated, made from the same material as that
of external and internal cladding of wall with locking arrangements
from inside and outside for main entry.
Main Door : Size of door W x H (8ft x 7ft) & quantity 2 Nos. [Location as shown in drawing]
 Insulation must as same of walls as mentioned above.
 Door should be rain proof in very heavy rainy conditions.
 Detachable metal staircase should be provided at the door entry
and also for terrace/roof.
Exterior Walls: Should be of 14 gauge or heavier gauge Galvanized vertical
corrugated MS sheet, CO2 welded to the frame. A ll gaps must be
sealed at edges, at seams, bottom sills etc.
Interior Walls: Should be covered with decorative laminated 8mm HDF board all
weather proof exterior grade.  Porta-cabin interior should be water proof, termite, heat and fire
resistant and should be comfortable in extreme hot or cold climate

Wiring should be of FRLS wire with flame retardant casing and should be provided with suitable sizing according
to the load. Raw power and UPS power wiring should be separately drawn and with clear marking of UPS and raw
power. All Power socket load should be directly tapped from DB. Suitable Main DB/panel should be provided with
adequate MCB‘s For isolation at the entrance of the cabin.
 All Switches, cables, MCB’s , DB’s , fittings should be of suitable rating and should be provided according to load.
Provision of Geyser and AC’s point (As per attached drawing) should be provided with inbuilt isolator MCB switch
and wiring should be drawn from Mains DB. All fittings/ fixtures should be LED with proper illumination. Three
separate earthing should be provided. One for UPS power earthing, second for raw power earthing and third for
body earthing of cabins. Make list provided at the end of the table should be used. In addition to standard
electrical fittings specific additional
electrical points are need to be provided as per figure

Windrows: Size of windows W x H (4ft x 3ft) & quantity 6 Nos.[Location as shown in drawing]
 Wherever required should be made from Aluminum anodized/powder coated extruded sections; fixed type fitted 0 0
withClear glasses (Toughened 12mm), with vertical blinds. Windows should be rain proof.

Sceptic Tank :CONSTRUCTION OF 10 USER SEPTIC TA NK AS PER STA NDARD DESIGN, DRAWING & INSTRUCTION OF
D R.only Each 0.00 0
ENGINEER –IN CHARGE ETC A LL COMPLETE.

MAKING SOAK PIT 2.5 M DIAMETER 3.0 METRE DEEP WITH 45 X 45 CM DRY BRICK HONEY COMB SHAFT WITH BRICKS
E OF CLASS DESIGNATION 75 AND S.W. DRAIN PIPE 100 MM DIAMETER, 1.8 M LONG COMPLETE AS PER STA NDARD R.only Each 0.00 0
DESIGN WITH F. P. S. BRICKS

F Security Cabin :(Size-3.3X2.8M) RCC FramedStructure With Corrogated Steel Roofing & BrickMasoery Work. R.only Each 0.00 0

G PROVIDING. AND PLACING ON TERRACE (AT ALL FLOOR LEVELS)POLY ETHYLENE WATER STORAGE TA NK ISI : 12701
MARKED WITH COVER AND SUITA BLE LOCKING ARRANGEMENT AND MAKING NECESSARY HOLES FOR INLET, R.only Each 0.00 0
OUTLET A ND OVERFLOW PIPES WITH FITTINGS A ND THE BASE SUPPORT FOR TA NK , CAPA CITY : 5000 Litre

You might also like