IR.20-150
MANUAL
EGG COUNTING SYSTEM
IR.20-150
All rights reserved. Reproduction of any part of this manual in any form whatsoever without Fancom’s
express written permission is forbidden. The contents of this manual are subject to change without notice. All
efforts have been made to assure the accuracy of the contents of this manual. However, should any errors be
detected, Fancom would greatly appreciate being informed of them. The above notwithstanding, Fancom can
assume no responsibility for any errors in this manual or their consequence.
MODIFICATIONS RESERVED
EC-declaration of compliance
Manufacturer : Fancom B.V.
Address : Industrieterrein 34
City : Panningen (the Netherlands)
Panningen 14-03-2012
Table of contents
About this manual
1. Introduction .............................................................................................. 1
2. Technical specifications ........................................................................... 2
3. Safety instructions and warnings ............................................................. 3
4. Mounting .................................................................................................. 4
5. Electrical connection ................................................................................ 5
6. Working.................................................................................................... 6
7. Maintenance ............................................................................................ 7
IR.20-150
This manual contains information about the installation and service of the
egg counter. Read this manual carefully and follow all safety instructions.
If you have any questions, please do not hesitate to contact Fancom. The
subjects discussed in this manual are listed in the table of contents.
Caution
The product could be damaged, if the procedures are not followed
carefully.
Caution
Life threatening situation, if the procedures are not followed carefully.
IR.20-150
1. Introduction
The egg counting systems have been specially developed for egg counting.
The eggs are placed on a conveyor belt and pass underneath the egg
counter.
1
IR.20-150
2. Technical specifications
Power supply
Supply voltage 24Vdc
Power consumption IR.20 40mA
IR.30 60mA
IR.40 80mA
IR.50 100mA
… (step - 20mA) …
IR.150 300mA
Housing
Plastic housing, protection class IP54
Dimensions (l×w×h) IR.20 230×50×31mm/ 9.00×1.96×1.22ins
IR.30 330×50×31mm/12.90×1.96×1.22ins
IR.40 430×50×31mm/16.90×1.96×1.22ins
IR.50 530×50×31mm/20.80×1.96×1.22ins
… (step - 100mm / 3,9ins) …
IR.150 1530×50×31mm/60.23×1.96×1.22ins
Ambient climate
Operating temperature range 0°C to +40°C/32 F to +104 F
Storage temperature range -10°C to +50°C/14 F to +122 F
Relative humidity <95%, uncondensed
2
IR.20-150
1. Read the safety instructions carefully before mounting and using the IR.20-
150.
2. After unpacking the IR.20-150, check for any possible transport damage.
Report any damage directly to the distributor. Never install a damaged
egg counter!
3
IR.20-150
4. Mounting
Observe the following points when mounting the egg counting system:
1. Mount the egg counter in an inclined position above the conveyor using
the bracket supplied (see Fig. 1). See bracket mounting drawing.
2. The sensor is at the bottom of the egg counter. Ensure the bracket
does not cover the sensor.
3. For an optimal count the eggs must be motionless on the belt. When
stopped, the belt should not back wind.
4. When mounted on a cross conveyor, the egg counter should be
positioned where the eggs cannot move (sideways). Moving eggs
could be registered more than once.
5. Intense light, namely sunlight and fluorescent light, can influence
accuracy. Place the egg counter out of direct (sun) light, or shield it
from light.
6. Mount the IR egg counter 2,5 cm above a large egg (no double-yolk).
0,85cm β
β = 9°
2,5cm
Fig. 1: Mounting the egg counter above the cross conveyor (side view).
4
IR.20-150
5. Electrical connection
Observe the following points when connecting the egg counting system:
1. Use low voltage cables for electrical connection of the egg counter
(max. length 100m).
2. Connect the egg counter according to the instructions in Fig. 2.
3. Mount the cables so that they cannot be damaged.
4. Ensure that cables can be easily replaced in the event of a
malfunction.
5. Separate high/low voltage cables by mounting them in separate cable
channels.
6. If metal cable channels are used ground them.
7. Seal all gland nuts to prevent the entry of moisture.
Caution!
Apply power only after all the cables have been connected correctly.
24Vdc
30mA
RD
BL
GN PULSE/10 or 12
PULSE/1
WH
RD = Red
BL = Black
GN = Green
WH = White
5
IR.20-150
6. Working
The egg counter has been calibrated at the factory.
The IR.20-150 egg counter gives one pulse per egg or one pulse per
10 eggs.
LED indication
The IR.20-150 has several LEDs (the IR.20 has 2 leds; the IR.30 3 leds; the
IR.40 4 leds; the IR.50 5 leds until IR.150 15 leds). These leds indicate the
egg counter status (Fig. 3).
The red LEDs illuminate when the counter is ready to start counting.
Fig. 3: IR.60 egg counter with six LEDs (viewed from below)
6
IR.20-150
7. Maintenance
The egg counter normally requires a minimum of maintenance. The lens
usually remains dust free.
Clean a dirty lens with an antistatic cloth or compressed air, preferably once
a month. If necessary, a non-aggressive glass cleaner can be used.
Caution!
When cleaning the poultry house, ensure running water or steam
does not damage the egg counters.