Bp 220

Study online at https://quizlet.com/_2c53nw

1. House and lot Bp 220 shall apply to the development


House or lot only of either a ___ and ____ or ______

2. Design standards for bp 220 A. Protection and safety of life, limb,


property, general public
B. Basic needs of human settlement
C. Affordability
D. Location

3. Basic needs of human settlement Water


Movement/ circulation
Storm drainage
Solid/liquid waste disposal
Parks and playground
Power

4. Affordable cost Refers to the most reasonable price


Ra 7279 of land and shelter based on the
needs and financial capability of pro-
gram beneficiaries and appropriate fi-
nancing scheme

5. 200mm Suitable trees with a caliper of ___ or


more, shrubs and desired ground cover
shall be preserved

6. Finishing grades of yards play- Good quality of soil shall not be re-
grounds parks and garden area moved and shall be presrved for __

7. Complete and permanent cover of Grass, shrubs and other landscsping


the area materials for ground cover shall be
planted as to allow ___

8. Fault traces Philvolcs resolution no.515, series of


1992

9. Hierarchy, accessibility, free from Location of parks shall be based on


hazards risks barriers

10. Bp344
1 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
Land circulation system shall comply
with the pertinent req. Of

11. 10m; 15cm If major road will function as intercon-


necting road, it shall have a min row
of__; it shall have a ___mix gravel / pit
run base course on well compacted sub
grade.

12. 3m depth; 5m lengt Subdivision projects abutting a main


public road must provide sufficient set-
backs with minimum dimension of __ in
depth and __ in length at both sides of
the subdivision entrance.

13. Alley; 2m Width of 2m intended to break a block


and to serve both pedestrians and for
emergency purposes; shall not be used
as access to property

14. Pathwalk; 3m width; 60m max Width 3m; provide pedestrian access to
length property for socialized housing projects;
max length ___

15. Pd 953 tree planting Planting strips are required under


_____

16. Resolution no. R-532 series of Every owner of existing subdivision is


1993 required among others to plant trees in
designated area

17. Asphalt- 50mm Major, minor road and motor court for
Concrete-150mm economic and socialized housing shall
Compressive strength: 20.7 mpa be paved with ____
at 28 days

18. Macadam finish Finish for sidewalk and alley

19. 20m

2 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
Distance between offset intersections
should not be less than ___corner to
corner.

20. 6m Radius of outer curb of cul de sac near


road

21. 4.5m Radius of inner curb of cul de sac

22. 21 to 31m Diameter of cul de sac

23. 1.5 to 9% Crown of the road shall have a slope of


not less than _____.

24. 40% Price of saleable lots intended for single


detached units shall not exceed ___ of
max selling price of the house and lot
package

25. 20 units per block; 100m max Row houses shall be __ units per block
length or cluster but in no case this be more
than _____ in length

26. 400m Max block length

27. 2m alley If block exceeds 250m, a ___approxi-


mately at mid length

28. 1.5m front and side setback Setbacks for socialized and economic
2 m rear setback housing

29. 300m Communal well shall not be closer than


____ from each other

30. 150 liters per capita per day Minimun quality of water consumption
for subdivision project

31. Operationa Deep well and pump Each subdivision must have at least an
sets ____ and ___ with sufficient capacity
to provide average daily demand to all
3 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
home owners provided a spare pump
and motor set is reserved

32. NWRB; LWUA Required permits from the ____ shall


be obtained and standards of ___ shall
be complied with

33. 25m Ground reservoir shall be at least ___


from sources of pollution / contami-
nants

34. 20% of average daily demand plus Water tank capacity


fire reserve

35. 50m Distance of street lighting per pole

36. Concrete lined canal with load Minimum drainage system for econom-
bearing cover ic and socialized housing

37. 300mm Minimum drainage pipe

38. 1.3m Row = 15m


Planting strip=?
Sidewalk = 1.20m

39. 0.80m Row= 12m, 10m


Planting strip=?
Sidewalk=1.20

40. 0.40m Row= 8m


Planting strip=?
Sidewalk=0.60m

41. Optional Row = 6.5


Planting strip=?
Sidewalk=0.50m

42. 2m Minimum horizontal dimension of


courts and yards

4 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
43. 1.20m Passageway with a minimum width of
___ or by a door thru room

44. 50% residential Private open space req. For interior lot
24% others

45. 20% residential Private open space req.


15% others For inside lot

46. 10% residential Private open space req.


5% others For corner and through lot

47. 5% residential Privats open space req.


5% others For lots bounded on 3 or more sides

48. 1 hour resistivity rating Minimum firewall fire resistivity rating

49. 2m Min ceiling height bp220

50. 1.80 above and below Min ceiling height mezzanine

51. 50% of floor area Mezzanine floor area

52. 1 for less than 10 people Min number of entrances


2 for more than 10 people

53. 2m; 1.8m for bathroom Min clear height of doors

54. Main door 0.80m Min clear width of doors


Service/Bedroom 0.70m
Bathroom 0.60m

55. 0.60m Min clear width of stairs

56. 250mm Max. Riser of stairs

57. 200mm Minimum tread of stairs exclusive of any


projections

58. 2m Head room clearance for stairs

5 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
59. 3.6m Max height between landings

60. 1 At least how many handrails?

61. 4 Stairways with less than __risers need


not to have handrails

62. 0.80m to 1.20m Handrail height

63. 38mm Handrail Clearance from wall

64. 150mm, 300mm from the narrower Min width of winding and circular stair
side of stairs

65. 1.80m Max distance between landings of lad-


ders

66. 5mm Max variation of risers and treads

67. At least 1 light outlet and 1 conve- Electrical requirements


nience outlet per activity area

68. 25% of total area Multifamily dwellings and condomini-


ums for socialized and economic hous-
ing : non residential areas shall be
equal and not more than ___?

69. 10m; 6m Minimum distance between buildings


with morethan 4 storeys shall be __?
Minimum horizontal clearance shall be
___.

70. 2m; 1m In cases when 2 sides of the buildings


facing each other are blank walls, ei-
ther there are no openings or only min-
imal openings for comfort rooms, the
minimum distance between bldgs shall
be ___. Horizontal distance between
eaves

6 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
71. Shortest Measurement of distance between 2
blgs shall be made where the distance
between the 2 buildings is ___.

72. 1 parking slot per 8 living units Parking requirement for multifamily
dwellings and condominiums

73. 2.15m x 6.00m Parallel and diagonal parking

74. 2.50m x 5.00m Perpendicular parking

75. 5m Driveway right of way

76. 100m Offsite parking allowed provided further


that it shall not be ___ away from con-
dominium projecy

77. 15m Automativ fire alarm suppression sys-


tem should be provided for structure
more than ___ in height

78. 6 storeys and beyond Provision of elevators required for build-


ings ______

79. 25 years Use of indigenous materials are en-


couraged as long as it conforms with
the rules and ensures a building life
span of at least ____.

80. Board resolution no. R-97 series Variances and exemptions for bp 220 is
of 1982 annex 2 stipulated in ____.

81. Sangguniang bayan or sangguini- Individual lot owners in bp220 may con-
ang panglunsod; city/ municipal struct their individual residential house
engineer by: 1. Development approval is secured
from LGU thru _____ prior to construc-
tion. 2. Proposed building plans are sub-
mitted to the ____ for approval

82. Hlurb or lgu


7 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
Every registered owner or developer of
a parcel of land who wishes to con-
vert the same into a subdivision projecy
shall apply with ____ or _____ for ap-
proval

83. 2 sets of sdp Optional application for preliminary


1:200 to 1:2000 signed by archi- subdivion development plan
tect, enp, civil engineer or geodet-
ic engineer

84. 500m Signed by geodetic engr


Vicinity map- at least within ____from
the property boundaries of the projecy

85. 25m apart in all direction; 0.50m Ground elevation for subdivision if less
than 2% spot elevations point not more
than ___; more than 2% indicate con-
tours not more than ____ if necrssary
due to irregular land

86. 180 days Approval of preliminary subdivision de-


velopment plans will be valid only for a
period of ____ from the date of approval

87. 1:200 Subdivision development plan scales


1:1000
Max 1:2000

88. Architect, enp, civil engineer or Site development plan shall be pre-
geodetic engineer pared signed and sealed by any li-
censed and registered _____

89. Professional mechanical engi- Should a pump motor has a horsepow-


neer er rating of 50hp or more, its pump rat-
ing and specs shall be signed by a ___?

90. National water resources board Application for permit to drill from____.
nwrb

8 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw
91. 30hec and above Traffic impact assessment for projects
____ are required

92. 3 years Development permit shall only be valid


for a period of ____ from the date of
issue if no physical development is in-
troduced

93. Licensed geodetic engineer Land surveys

94. Pd 1529 Property rrgistration decree


Ra 8560 irr

95. Hlurb form 001 Licensed to sell


Sworn registration statements for cor-
poration

96. Hlurb form 003 Licensed to sell


Sworn registration statement for single
proprietorship

97. 3'x 6' billboard A ______ billboard notice of the project


shall be posted on the project site until
the issuance of the license to sell

98. 2 weeks Failure to publish the notice of filling of


registratin statement within ____ from
the receipt to publish issued by board,
owner shall be required to refile the ap-
plication for certificate of registration

99. 5 days After ___ days from the completion of


publication, the board shall issue a cer-
tificate of registration

100. 2 weeks Within ___ from registration of the pro-


ject, no owner or developer shall sell
any disposable subdivision lots or con-
do in a registered property without a
license to sell by the board
9 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw

101. 10% of development cost of un- Surety bond


finished portion of the approved
plan

102. At least 10% of the total develop- Real estate mortgages


ment cost

103. Cash bonds 5% of the development cost of the un-


Fiduciary deposits finished portion of the approved plan
Guarantee deposit which may be in the form of:
Letter from bank
Irrevocable credit line to be uti-
lized in the devt

104. July 12 1993 Presidential decree 953 was approved


when?

105. Certificate of completion; deed of The developer shall be relieved of the


donation for the road lot and open obligation to maintain trees planted only
spaces upon the issuance of a ___ by hlurb
and upon receipt by lgu concerning the
____ duly executed in their favor on the
homeowners association in the case of
parks and playground with consent of
local government

106. July 6 1976 Existing subdivision approved after


____.

107. Memorandum circular no. 29 Amended pd 953


Series of 2005 july 19 Supplemental rules and regulations to
implement pd 953 administrative order
no. 2 series of 1994

108. Shade trees Large trees with profused branches, ex-


tended laterally, min 4m height

109. Ornamental tree Medium sized trees with less profused


branches, max height 3m
10 / 11
Bp 220
Study online at https://quizlet.com/_2c53nw

110. Garden plants Single woody stem plants which do not


have primary branches

111. Along the side; electrical pow- Shade trees shall be planted ___ of
er distribution lines; 5m recom- the road opposite the ______. Recom-
mended distance mended distance between shade trees

112. Along side of the electrical power Ornamental trees shall be plant-
distribution lines; 3m ed_____. Recommended distance be-
tween ornamental trees

113. 3m Vertical clearance from topmost part of


the ornamental trees to primary electri-
cal power distribution lines

114. Coconut and other high growing Shall not be allowed in all designated
plants planting strips

115. 1m in height for higher plant sur- Recommended potted planting materi-
vival als is at least ___.

116. 1 tree per saleable lot Ratio of trees in subdivisions

117. Resolution no. 55 series 1982 of Evaluation of applications for the inte-
executive committee grated permit by hsrc personnel

118. Pd 957 Subdivision and condominuim buyers


protective decree

119. Pd 1216 Defining open spaces

120. 56cm least dimension; 0.45 sqm; Pd 1185 outside window dimension;
122cm height from ffl

121. 90 cm wide Pd 1185: No exit access from sleeping


rooms to outside shall be less than_.

122. 60cm wide Pd 1185: Interior door providing exit


less than