Abreeza Residences (2) - Report

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 18

Toshiba VRF Piping Selection Tool Report

7/14/2014

Project Information Version 2.4.84.0


Project Name Abreeza Residences (2)
System Type SMMS-i
Customer Name Abreeza Residences (2)
Address
Installer
Installation Date 7/14/2014
Commissioning Date 7/14/2014

Equipment List
Outdoor Units
Model Name Quantity
MMY-MAP1604T8-E 2
MMY-AP2014T8-E 1
MMY-AP2214T8-E 1

Indoor Units
Model Name Quantity
MMD-AP0241BH 1
MMD-AP0244BH-E 7
MMD-AP0276BH-E 1
MMC-AP0364H-E 8

Outdoor Connection Kits


Model Name Quantity
RBM-BT14E 2

Y-joints
Model Name Quantity
RBM-BY55E 2
RBM-BY105E 7
RBM-BY205E 4

Header
Model Name Quantity

Accessories
Model Name Quantity

Central Control Devices


Model Name Quantity

Piping Length - Project Totals


(in) φ1/4 φ3/8 φ1/2 φ5/8 φ3/4 φ7/8 φ1 1/8 φ1 3/8 φ1 5/8
Total(m) 19 10.6 22 1 10 3.6 1
Gas side(m) - 0 0 19 0 10 3.6 1
Liquid side(m) 19 10.6 3 1 0 - -

Refrigerant Change Amount(Additional Refrigerant Required) - Project To


Total(kg) 31.888

Outdoor Design Temperature


Cooling 35 deg(C) (Dry Bulb)
System Information
Ref. Cycle Number 1
Ref. Cycle Name ACCU-GF-01
System Type SMMS-i

Outdoor Unit
Model Name
Header Unit Follower Unit1 Follower Unit2 Follower Unit3
MMY-MAP1204T8-E MMY-MAP1004T8-E - -

Capacity Rated Capacity(kW) Corrected Capacity(kW)


Cooling 61.5 61.28

Diversity 59%

Location Below

Indoor unit(s)
Rated Corrected Required
Capacity Capacity(kW) Capacity(kW) Capacity(kW) Fan
Model Name Quantity
Code Speed
Sensible Total Sensible Total Sensible Total
MMD-AP0241BH 2.5 5 7.1 5 7.10 (7.10) 4 6.9 High 1
MMD-AP0276BH-E 3 5.8 8 5.78 7.97 (7.97) 4.7 7.2 High 1
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 3 6.9 High 1
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 3 6.9 High 1
MMD-AP0244BH-E 2.5 5 7.1 4.98 7.07 (7.07) 3 6.9 High 1

Outdoor Connection Kits


Model Name Quantity
RBM-BT14E 1

Y-joints
Model Name Quantity
RBM-BY55E 1
RBM-BY105E 2
RBM-BY205E 1

Header
Model Name Quantity

Accessories
Model Name Quantity

Piping Length
(in) φ1/4 φ3/8 φ1/2 φ5/8 φ3/4 φ7/8 φ1 1/8 φ1 3/8 φ1 5/8
Total(m) 6 3.8 6 1 3.2 0.6 1
Gas side(m) - 0 0 6 0 3.2 0.6 1
Liquid side(m) 6 3.8 0 1 0 - -

Refrigerant Change Amount(Additional Refrigerant Required)


Total(kg) 5.979

Electric information(Outdoor Unit(s))


MOCP (A) 63.00(40.00 + 32.00)
MCA (A) 54.00(28.50 + 25.50)
Protection Device size (A) 63
Wire(Cable Size) (mm2 or AWG(#))

Electric information(Indoor Unit(s))


Total MCA (A) 3.75
Protection Device size (A) 75
Wire(Cable Size) (mm2 or AWG(#))

System Information
Ref. Cycle Number 2
Ref. Cycle Name ACCU-GF-02
System Type SMMS-i

Outdoor Unit
Model Name
Header Unit Follower Unit1 Follower Unit2 Follower Unit3
MMY-MAP1604T8-E - - -

Capacity Rated Capacity(kW) Corrected Capacity(kW)


Cooling 45 45

Diversity 62%

Location Below

Indoor unit(s)
Rated Corrected Required
Capacity Capacity(kW) Capacity(kW) Capacity(kW) Fan
Model Name Quantity
Code Speed
Sensible Total Sensible Total Sensible Total
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 4.55 6.5 High 1
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 4.55 6.5 High 1
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 4.55 6.5 High 1
MMD-AP0244BH-E 2.5 5 7.1 5 7.10 (7.10) 4.55 6.5 High 1

Outdoor Connection Kits


Model Name Quantity

Y-joints
Model Name Quantity
RBM-BY55E 1
RBM-BY105E 1
RBM-BY205E 1

Header
Model Name Quantity

Accessories
Model Name Quantity

Piping Length
(in) φ1/4 φ3/8 φ1/2 φ5/8 φ3/4 φ7/8 φ1 1/8 φ1 3/8 φ1 5/8
Total(m) 5 1 6 1 1
Gas side(m) - 0 0 5 1 1
Liquid side(m) 5 1 1 0 - -

Refrigerant Change Amount(Additional Refrigerant Required)


Total(kg) 11.04

Electric information(Outdoor Unit(s))


MOCP (A) 50
MCA (A) 36.5
Protection Device size (A) 50
Wire(Cable Size) (mm2 or AWG(#))

Electric information(Indoor Unit(s))


Total MCA (A) 3
Protection Device size (A) 60
Wire(Cable Size) (mm2 or AWG(#))

System Information
Ref. Cycle Number 3
Ref. Cycle Name ACCU-GF-03
System Type SMMS-i

Outdoor Unit
Model Name
Header Unit Follower Unit1 Follower Unit2 Follower Unit3
MMY-MAP1004T8-E MMY-MAP1004T8-E - -

Capacity Rated Capacity(kW) Corrected Capacity(kW)


Cooling 56 55.99

Diversity 80%

Location Below

Indoor unit(s)
Rated Corrected Required
Capacity Capacity(kW) Capacity(kW) Capacity(kW) Fan
Model Name Quantity
Code Speed
Sensible Total Sensible Total Sensible Total
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.05 9 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.05 9 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.05 9 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.05 9 High 1

Outdoor Connection Kits


Model Name Quantity
RBM-BT14E 1

Y-joints
Model Name Quantity
RBM-BY105E 2
RBM-BY205E 1

Header
Model Name Quantity

Accessories
Model Name Quantity

Piping Length
(in) φ1/4 φ3/8 φ1/2 φ5/8 φ3/4 φ7/8 φ1 1/8 φ1 3/8 φ1 5/8
Total(m) 4 3.8 5 3.8 1
Gas side(m) - 0 0 4 3.8 1
Liquid side(m) 4 3.8 1 0 - -

Refrigerant Change Amount(Additional Refrigerant Required)


Total(kg) 3.779

Electric information(Outdoor Unit(s))


MOCP (A) 63.00(32.00 + 32.00)
MCA (A) 51.00(25.50 + 25.50)
Protection Device size (A) 63
Wire(Cable Size) (mm2 or AWG(#))

Electric information(Indoor Unit(s))


Total MCA (A) 4.52
Protection Device size (A) 60
Wire(Cable Size) (mm2 or AWG(#))

System Information
Ref. Cycle Number 4
Ref. Cycle Name ACCU-5F-01
System Type SMMS-i

Outdoor Unit
Model Name
Header Unit Follower Unit1 Follower Unit2 Follower Unit3
MMY-MAP1604T8-E - - -

Capacity Rated Capacity(kW) Corrected Capacity(kW)


Cooling 45 45

Diversity 100%

Location Below

Indoor unit(s)
Rated Corrected Required
Capacity Capacity(kW) Capacity(kW) Capacity(kW) Fan
Model Name Quantity
Code Speed
Sensible Total Sensible Total Sensible Total
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.03 10.5 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.03 10.5 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.03 10.5 High 1
MMC-AP0364H-E 4 7.6 11.2 7.6 11.20 (11.20) 6.03 10.5 High 1

Outdoor Connection Kits


Model Name Quantity

Y-joints
Model Name Quantity
RBM-BY105E 2
RBM-BY205E 1

Header
Model Name Quantity

Accessories
Model Name Quantity

Piping Length
(in) φ1/4 φ3/8 φ1/2 φ5/8 φ3/4 φ7/8 φ1 1/8 φ1 3/8 φ1 5/8
Total(m) 4 2 5 2 1
Gas side(m) - 0 0 4 2 1
Liquid side(m) 4 2 1 0 - -

Refrigerant Change Amount(Additional Refrigerant Required)


Total(kg) 11.09

Electric information(Outdoor Unit(s))


MOCP (A) 50
MCA (A) 36.5
Protection Device size (A) 50
Wire(Cable Size) (mm2 or AWG(#))

Electric information(Indoor Unit(s))


Total MCA (A) 4.52
Protection Device size (A) 60
Wire(Cable Size) (mm2 or AWG(#))

Note: Equivalent length is calculated by coefficient 1.300

- The user is responsible for ensuring that all data entered is correct.

- Equipment selections have been based on the Design Guidelines stated within the Toshiba SMMS-i/SHRM-i/Mini-SMMS Installation Manual.

- It is the responsibility of the consultant or contractor, to verify and confirm that the equipment selection and system design is correct before
installation.
- Please note that in the event of future system expansion being allowed for in the system design or a change in cooling/heating requirements, a re-
evaluation of the air conditioning system must be made prior to final installation.
System Information
Project Name Abreeza Residences (2)
Ref. Cycle Number 1
Ref. Cycle Name ACCU-GF-01
System Type SMMS-i
Outdoor Unit Model Name MMY-AP2214T8-E
Indoor units Quantity 5
Total Pipe Length(m) 10.8
Refrigerant Charge Amount(kg) 5.979
Diversity 59%
Location Below
Capacity Rated Capacity(kW) Corrected Capacity(kW)
Cooling 61.5 61.28
Wiring Schematic
Piping Schematic

System Information
Project Name Abreeza Residences (2)
Ref. Cycle Number 2
Ref. Cycle Name ACCU-GF-02
System Type SMMS-i
Outdoor Unit Model Name MMY-MAP1604T8-E
Indoor units Quantity 4
Total Pipe Length(m) 7
Refrigerant Charge Amount(kg) 11.04
Diversity 62%
Location Below
Capacity Rated Capacity(kW) Corrected Capacity(kW)
Cooling 45 45
Wiring Schematic
Piping Schematic

System Information
Project Name Abreeza Residences (2)
Ref. Cycle Number 3
Ref. Cycle Name ACCU-GF-03
System Type SMMS-i
Outdoor Unit Model Name MMY-AP2014T8-E
Indoor units Quantity 4
Total Pipe Length(m) 8.8
Refrigerant Charge Amount(kg) 3.779
Diversity 80%
Location Below
Capacity Rated Capacity(kW) Corrected Capacity(kW)
Cooling 56 55.99
Wiring Schematic
Piping Schematic

System Information
Project Name Abreeza Residences (2)
Ref. Cycle Number 4
Ref. Cycle Name ACCU-5F-01
System Type SMMS-i
Outdoor Unit Model Name MMY-MAP1604T8-E
Indoor units Quantity 4
Total Pipe Length(m) 7
Refrigerant Charge Amount(kg) 11.09
Diversity 100%
Location Below
Capacity Rated Capacity(kW) Corrected Capacity(kW)
Cooling 45 45
Wiring Schematic
Piping Schematic
Concealed Duct Standard Type

Technical specifications
Model name MMD-AP0241BH MMD-AP0276BH-E MMD-AP0244BH-E
Cooling/Heating capacity (kW) 7.1/8.0 8.0/9.0 7.1/8.0

Power requirements 1-phase 50 Hz 230 V (220–240 V) (Separate power supply for indoor units required.)
Electrical
characteristics
Power consumption (kW) 0.06 0.077 0.06

Appearance
Model RBC-UD281PE(W)/RBC-UD501PE(W)/RBC-UD801PE(W)/RBC-UD1401PE(W)
(Ceiling Panel)
External Height (mm) 320 (9) 275 320 (9)
dimensions:
Width (mm) 1000 (1080) 1000 1000 (1080)
Main unit
(Ceiling Panel) Depth (mm) 800 (500) 750 800 (500)
Total weight: Main
unit (kg) 43 (6) 30 43 (6)
(Ceiling Panel)
Standard air flow
(m3/h) 1140/990/870 1200/930/720 1140/990/870
(High/Mid/Low)
Fan unit
Motor output (W) 120 150 120
Gas side (in) φ5/8
Connectiong
Liquid side (in) φ3/8
pipe
Drawin port (nominal dia.) 25 (Polyvinyl chloride tube)
Sound pressure
level (dB(A)) 33/31/29 36/31/27 33/31/29
(High/Mid/Low)
Under Ceiling Type

Technical specifications
Model name MMC-AP0364H-E
Cooling/Heating capacity (kW) 11.2/12.5

1-phase 50 Hz 230 V (220–240 V)


Power requirements (Separate power supply for indoor
Electrical
units required.)
characteristics
Power consumption (kW) 0.091

Height (mm) 210


External
dimensions: Width (mm) 1595
Main unit
Depth (mm) 680
Total weight: Main
(kg) 34
unit
Standard air flow
(m3/h) 1650/1380/1200
(High/Mid/Low)
Fan unit
Motor output (W) 80
Gas side (in) φ5/8
Connectiong
Liquid side (in) φ3/8
pipe
Drawin port (nominal dia.) 20 (Polyvinyl chloride tube)
Sound pressure
level (dB(A)) 41/38/35
(High/Mid/Low)
SMMS-i
22(HP) 16(HP) 20(HP)
Model name MMY-AP2214T8-E MMY-MAP1604T8-E MMY-AP2014T8-E
Outdoor unit type Inverter unit
Outdoor unit model MMY-MAP1204T8-E MMY-MAP1004T8-E MMY-MAP1604T8-E MMY-MAP1004T8-E MMY-MAP1004T8-E
Cooling capacity Outdoor temp. 35(CDB) (kW) 61.5 45 56
Heating capacity (kW) --
Power supply 3phase 4wires 50Hz 400V (380-415V)
Minimum (V) 342
Voltage range
Maximum (V) 456
Running current (A) 26 17.6 22.8
Cooling
Power consumption (kW) 16.96 13.7 14.82
Outdoor temp.
Power factor (%) 94 95 94
35(CDB)
EER(Energy Efficiency Ratio) (kW/kW) 3.63 3.28 3.78
Electrical
Running current (A) 0
characteristics
Power consumption (kW) 17.7 14.2 15
Heating
Power factor (%) 92 93 92
COP (kW/kW) 3.9 3.52 4.2
Starting Current (A) Soft Start
Height (mm) 1887 1887 1887 1887 1887
Packing Width (mm) 1062 1062 1282 1062 1062
Depth (mm) 828 828 828 828 828
Dimension
Height (mm) 1830 1830 1830 1830 1830
Unit Width (mm) 990 990 1210 990 990
Depth (mm) 780 780 780 780 780
Packing (kg) 256 256 347 256 256
Weight
Unit (kg) 241 241 330 241 241
Color Silky shade (Munsell iY8.5/0.5)
Type Hermetic twin rotary compressor
Compressor
Motor output (kW) 4.2 x 2 3.1 x 2 3.6 x 3 3.1 x 2 3.1 x 2
Fan Propeller fan
Fan unit Motor output (kW) 1 1 1 1 1
Air volume (m3/h) 11600 10500 13000 10500 10500
Heat exchanger Finned tube
Charged R410A
Refrigerant
refrigerant (kg) 10.5 10.5 11.5 10.5 10.5
High-pressure switch amount (MPa) OFF:2.9 ON:3.73

Discharge temp. sensor


Suction temp. sensor
High-pressure sensor
Protective devices
Low-pressure sensor
High-pressure switch
PC board fuse

MCA (A) 54 36.5 51


Power supply wiring Unit
MOCP (A) 63 50 63
Gas side (in) φ1 3/8 φ1 1/8
Connecting port
Liquid side (in) φ3/4 φ5/8
diameter
Balance side (in) φ3/8
Gas side Brazing
Connecting
Liquid side Flare
Method
Balance side Flare
Refrigerant piping Max. equivalent length (m) 220 210 220
real length
Max. total pipe (m) 180 170 180
length(Real (m) 300
length)
Max. height Higher than indoor unit 70
(m)
difference Lower than indoor unit 40
Control wiring between indoor and (Up to 1000m) Shield wire 1.25mm2 x 2 cores
outdoor
units + Central controller wiring (Up to 2000m) Shield wire 2.0mm2 x 2 cores
Max. No. of connected indoors unit 37 27 33
(db(A)) 61.5 62 60
Cooling
Silent mode (db(A)) -
Sound pressure level
(db(A)) 63.5 64 61
Heating
Silent mode (db(A)) -
Cooling (db(A)) 82 78 83 78 78
Sound power level
Heating (db(A)) 83 79 84 79 79
Max. external static pressure (Pa) 50 60 40 60 60
Cooling CDB -5 to 43
Operation temperature range
Heating CWB -20 to 15.5

You might also like