Professional Documents
Culture Documents
(已压缩)Pigeon Brochure
(已压缩)Pigeon Brochure
,LTD
Email:sandy@pigeon-medical.com
Tel: 86-18666310927
Fax: 86-663-2286006
Website: h�p://www.gdgezi.com
Headquarter Factory
Puning City
No.118,6/Zhuyuan,ChiweiTown,Puning City,Guangdong ,China
OPTIMAL RESPIRATORY
Branch Factory
Dongguan City
No.180,Donghuan Road,Xincheng Industrial Zone,Hengli Town,Dongguan City,Guangdong ,China
SOLUTION
Shenzhen Office
24F,Building A,Zhongzhi Time Square,Donghuan Second Road,Longhua New District,Shenzhen City,Guangdong,China
Profile INTRODUCTION
MAIN PRODUCT
----------------------------------------------------------------03
Business History
----------------------------------------------------------------05
NCPAP
----------------------------------------------------------------11
Air Oxygen Blender
Medical Air Compressor
----------------------------------------------------------------15
----------------------------------------------------------------17
Infant Resuscitator
Guangdong Pigeon Medical Apparatus Co.,Ltd. is a high-tech enterprise specializing in
----------------------------------------------------------------19
Humidifier
independent research & development,produc�on & sale of infant and maternal care
products and assis�ve products since 1990s. Main products are Infant NCPAP, Air-oxygen ----------------------------------------------------------------22
Neonate Transport
Blender, Medical Air Compressor, Medical Hea�ng Respiratory Humidifier, Infant ----------------------------------------------------------------24
Suc�on
Resuscitator, Oxygen Inhaler and Oxygen Analyzer,Neonate bed, etc. ----------------------------------------------------------------25
Oxygen Analyzer
Pigeon Medical dominates the Chinese and overseas market with high-quality products, ----------------------------------------------------------------27
Adult HFNC
professional skills,superior direct sales and a�er sales force, following four main ----------------------------------------------------------------28
Infant HFNC
principles: Advanced Technology, Excellent Quality, Users Supremacy and Customer ----------------------------------------------------------------29
Oxygen Inhaler
Sa�sfac�on.
----------------------------------------------------------------30
Circuit Support Arm
----------------------------------------------------------------31
Trolley
Parts
----------------------------------------------------------------33
OPTIMAL RESPIRATORY
SOLUTION PIGEON 04
Business
History
Established as Cer�fied ISO. Start to entry Having distributors Establish Shenzhen
a state owned interna�on market. in over 20 countries, office.
enterprise in Puning, serving over
Guangdong. 8000 hospitals.
NCPAP
Nasal Con�nuous Posi�ve Airway Pressure(NCPAP) is a form of posi�ve airway
pressure ven�la�on with nasal prongs to keep the airways con�nuously open in people
who are able to breathe spontaneously. Pigeon AD series commit to respiratory care
for premature, neonate, pediatric with nasal prongs and are widely applied in
ICU,NICU,PICU,etc.
Interface
Mode Descrip�on
Mode Descrip�on
NCPAP
08-01-03-64I Infant Bonnet,29-36cm
A
#-1 #1.5
B
#-2 #2 C
E
#0 #3 D
#1 #4
Size A B C D E
Horizontal
#-1 5mm 1.5mm 3.5mm 2.4mm 3mm
nasal prong
#1 6mm 2.5mm 4.5mm 3.5mm 3mm
AD3000-SPA AD3000-SPB
Alarm When gas supply pressure difference>0.1 MPa Pressure Air/Oxygen @ 0.3 - 0.4 MPa
Alarm nosie >57 dB(A) >57 dB(A) >57 dB(A) >57 dB(A) Alarm When gas supply difference > 0.1 MPa
Recommended
Blender Accessories
Product code Product code
10-29-02-01 10-29-02-03
Descrip�on Descrip�on
Air high pressure tube, Oxygen high pressure tube,
2m(6.5�),black 2m(6.5�),blue
10-29-02-01 10-29-02-03
10-29-14-12 10-29-19-02
Medical
Air Compressor
Pigeon PN series provide air support for
CPAP,ven�lator,anaesthesia machine,etc. PN-5000 PN-4000
Oil-free,water-free,noise-free.
Integrated with American GAST/THOMAS oil-free pump.
Mul�ple well-known pneuma�c components such as Japanese SMC& UK NORGREN.
Double output is op�onal,providing air support for more than one machine.
PN-3000 PN-2000
Power source AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz AC 220V/110V, 50-60Hz
08-01-03-14
08-01-03-98
Model AD3000-TPA AD3000-TPB
Flow / 0-15LPM
FiO2 / 21%-100%
@5 LPM,2~27 cmH2O
PIP
@8 LPM,4~36 cmH2O 06-04-04-06A
@10 LPM,6~42 cmH2O
Humidifier Accessories
Humidifica�on chambers
Thermal cut off 95±6℃ Descrip�on Reusable chamber,adult,PC material Descrip�on Reusable chamber,infant,PC material
Temperature
0-75℃
monitoring
Max-temperature of
85℃
heated plate
Heatedwiremode:
Invasive Mode:
P1:25-29℃
Chamber outlet:
P2:29-35℃
35.5-37℃, Airway 35-40℃ VHC20 VHC10
Temperature P3:35-39℃
/
Control Se�ngs Non-heated wire mode: Noninvasive Mode: Model VHC20 Model VHC10
P1:23-27℃ Chamber outlet:
P2:27-32℃ 31℃, Airway 28-34℃ Descrip�on Disposable chamber,auto-fill,adult Descrip�on Disposable chamber,auto-fill,infant
P3:32-37℃
Suc�on
Oxygen Analyser
Characteris�cs:
Convenient to use with small size
The ba�ery is chargeable(3.7V) that is convenient to carry
Stable performance and high precision
Base Unit Specifica�ons
Economical and prac�cal
Measurement Range 0.0-100%
Resolu�on 0.1%
Technical parameters: ±1% of full scale at constant temperature,
Oxygen concentra�on:21%-100% Accuracy and Linearity
R.H.and pressure when calibrated at full scale Total
Power:DC 3.7V
Use life of oxygen sensor:2 years Accuracy ±3% Actual oxygen level over full opera�ng temperature range
Low ba�ery alarm
Response Time 90% of final value in approximately 15 seconds at 23"C
Humidity 0-95%(non-condensing)
Expected Sensor Life >1,000,000% 02 Hours over 2 years in typical applica�ons Alarm
Low Oxygen Alarm Range 0%-99% (> 1% lower than low alarm)
High Oxygen Alarm Range 1%-100% (>1% higher than low alarm)
Adult HFNC
Pigeon High Flow Nasal Cannula(HFNC) oxygen therapy is a form of High Flow Nasal Cannula
non-invasive respiratory support which comprises an air oxygen blender,
an ac�ve humidifier ,a single heated circuit and a nasal cannula.It delivers
adequately heated and humidified medical gas up to 60 L/min,and is Code Descrip�on
considered to have a number of physiological effects.
HFNC-001 High flow nasal cannula ,Large
FiO2 21%-100%
Infant HFNC
Alarm Noise >57 dB(A)
Accuracy of FiO2 3%
Flow meter
Manual connec�on
Humidifier
Humidifier filter core
Performance parameters
Type Hanging weight Material Surface treatment Arm length Tube diameter
Pressure resistance:before the flow control valve should be able to bear the pressure of 10 bar.
Humidifica�on bo�le should not be broken under pressrue 0.5MPa±0.05MPa. Aluminum, Oxida�on,
Light 0.5 kg 390mm x 380mm x 380mm x 95mm Φ14
Flow control range:1L/min~15L/min stainless steel electropla�ng
Pressure of relief valve:0.35MPa±0.35MPa,the relief valve will exhaust automa�cally.
Aluminum, Oxida�on,
Tighten the flow valve and sealed the parts connec�on of inhaler.Shall not be lock. Heavy 1.5 kg 400mm x 420mm x 420mm x120mm Φ16
stainless steel electropla�ng
Humidifica�on bo�le:GZ-XRQ-1 45~85ml.
OPTIMAL RESPIRATORY
SOLUTION PIGEON 32
Trolley
Completed Matching Solu�on of Ven�lator
Fabian
MV
AVEA
VELA
RESMED
SLE
Newport
GE
OPTIMAL RESPIRATORY
SOLUTION PIGEON 34
Parts