Professional Documents
Culture Documents
WL 320 Wet Cooling Tower Gunt 1496 PDF - 1 - en GB
WL 320 Wet Cooling Tower Gunt 1496 PDF - 1 - en GB
WL 320 Wet Cooling Tower Gunt 1496 PDF - 1 - en GB
WL 320
Wet cooling tower
• principle and characteristic vari- The evaporated water volume is recorded. • thermodynamic principles of the wet
ables of a wet cooling tower with The air flow is generated by a fan and ad- cooling tower
forced ventilation justed using a throttle valve. • changes of state of the air in the h-x dia-
• transparent, easily interchangeable gram
cooling column with wet deck sur- The cooling column is transparent allowing • determination of the cooling capacity
face clear observation of the wet deck surface • energy balances
• 4 additional cooling columns avail- and the trickling water. Interchangeable • calculation of process parameters, such
able as accessory cooling columns (WL 320.01 – as maximum cooling distance, cooling
WL 320.04) enable comparative stud- zone width etc.
Wet cooling towers are a proven method ies.GUNT software for data acquisition via • in conjunction with the cooling columns
of closed-circuit cooling and heat dissipa- USB under Windows 10 WL 320.01-WL 320.04
tion. Typical areas of application are: air · comparison of different wet deck sur-
conditioning, heavy industry and power All important process parameters are re- faces
plants. corded (volumetric air flow rate, temperat-
ures of air and water, air humidity, water
In wet cooling towers the water to be flow rate). The measured values can be
cooled is sprayed over a wet deck surface. read on digital displays. At the same time,
Water and air come into direct contact in the measured values can also be transmit-
the counterflow. The water is cooled by ted directly to a PC via USB. The data ac-
convection. Some of the water evaporates quisition software is included. The changes
and the evaporation heat removed further of state of the air are represented in an h-x
cools down the water. diagram.
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 1/3 - 11.2023
gunt
WL 320
Wet cooling tower
Specification
Cooling column
• specific surface of the wet deck surface: 110m2/m3
• cross-section: 150x150mm
Volumetric air flow measurement via orifice: Ø 80mm
Heater, adjustable in three stages:
• 500W
• 1000W
• 1500W
Thermostat: switches off at 50°C
Fan
• power consumption: 250W
• max. pressure difference: 4,3mbar
• max. volumetric flow rate: 13m3/min
Pump
• max. head: 70m
• max. flow rate: 100L/h
1 fan, 2 air chamber, 3 tank with heater, 4 pump, 5 tank for additional water, 6 cooling Tank for additional water: 4,2L
column with wet deck surface; T temperature, H humidity, dp differential pressure, F water
flow rate
Measuring ranges
• differential pressure: 0…10mbar (air)
• flow rate: 12…360L/h (water)
• temperature: 2x 0…50°C, 3x 0…100°C
• rel. humidity: 10…100%
Scope of delivery
Changes of state of air and water in the h-x diagram as online representation in the soft-
ware 1 trainer
1 cooling column type 1
1 GUNT software + USB cable
1 set of instructional material
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 2/3 - 11.2023
gunt
WL 320
Wet cooling tower
Optional accessories
Other accessories
WL 320.01 Cooling column, type 2
WL 320.02 Cooling column, type 3
WL 320.03 Cooling column, type 4
WL 320.04 Cooling column, type 5
WP 300.09 Laboratory trolley
G.U.N.T. Gerätebau GmbH, Hanskampring 15-17, D-22885 Barsbüttel, Telefon (040) 67 08 54-0, Fax (040) 67 08 54-42, Email sales@gunt.de, Web www.gunt.de
We reserve the right to modify our products without any notifications. Page 3/3 - 11.2023