ELECTRICAL SHAFT
26 PAX
1600 CFM
2350X3390 X-RAY
4.0TR
LIFT
AHU
USG
8 PAX ROOM ELECTRICAL
1780X1750
PARKING AREA ROOM
CONTINUOUS GRILLE
SIZE- 6800x150, 1 NO. LEAD LINED DOOR 700 CFM
600X200
3 No.s collar size = 800x150 SAMPLE
WOODEN STAIRCASE
Y 530CFM (TYP) COLLECTION
ROOM
250X250
LIFT
LOBBY 250X300 350X300
PRINTING
DRY CAFETERIA AREA AND CR
1375 CFM
150X300
400X300
2000 CFM IN LINE EXHAUST FAN
UP DIAGNOSTICS
RECEPTION/ CASH AND TOILET
2 REPORT DISTRIBUTION
FEMALE
SHEAR WALL TO
2060 CFM
600X300
SUPPORT THE
WC
RCC CANOPY @
SO1
2450 LVL. UPPER BED LIFT TOILET
MALE
BASEMENT @-1050 LVL. VCD 1050 CFM 26 PAX
RCC PORTICO ENTRANCE 450X250 3390X2350
DIAGNOSTICS WC
z ABOVE
CHW S/R PIPE @-1050 LVL. z FD
VCD
WAITING AREA
4350X7400 CHW S/R PIPE
5500CFM
13.75TR
LIFT LOBBY
SIZE-Ø150MM. VCD
AHU
2640 CFM SIZE-Ø150MM.
Ø25MM. FIRE FIGHTING SHAFT Ø25MM. Ø25MM. 800X300
BED LIFT FRESH AIR DUCT
FIRE FIGHTING SHAFT 5500 CFM VCD 26 PAX
1200X300 WITH DAMPER
3390X2350
SIZE = 780X200
Ø50MM.
3 HVAC
800 CFM
LOCKER
300X300
TREAD @ 300 MM.
CHANGE SHAFT
Ø65MM.
RISER @146.15MM GYPSUM FALSE CEILING - LVL.+2600
PRINTING RADIOLOGIST RM. Ø50MM. LINEN STORE
NO. OF RISERS = 26 CORRIDOOR
AND CR ROOM Ø50MM.
200 CFM
DN
UP
600 CFM
STORE
300X200
MACHING SIZE :-
1200 CFM
LEAD LINED WINDOW
1200 CFM
400X300
750X200
PARKING AREA
STRETCHER
450x450 (N.S.) CONSOLE
STORE 13.75 TR - 5500CFM = 1200(W)X1000(L)X610(H)-CSAHU
BAY
SA & RA DIFFUSER S & R. AIR
LEAD LINED DOOR
CONTINUOUS GRILLE
Ø50MM.
1200 CFM SIZE- 1585x150, 1 NO.
17 TR - 6800CFM = 1550(W)X1850(L)X1530(H)-FMAHU
2400 CFM
600 CFM 750X200
650X300
1200 CFM
600X150
750X200
1200 CFM
750X200
X-RAY
200 CFM
400X150
4 CHANGE (M) CHANGE (F) 3.5 TR - 1250CFM = 1000(W)X1260(L)X610(H)-CSAHU
755
1200 CT SCAN
2400 CFM
LOCKERS (M) LOCKERS (F) 6800 CFM AHU AHU EQUIPMENT 650X300 GENERAL
&
17 TR VCD
STORE
CHANGE (M) CHANGE (F) 4400 CFM TOOLS
PLENUM 800X300 BATTERIES
1.2X1.5X0.5(H) NOTE :-
Ø50MM. UPS
300
VCD
ROOF OF LOWER BASEMENT ALL COLLIER SIZE = 450X150
DIFFUSER SIZE = 450X450 (OUTER SIZE)
FRESH AIR DUCT 450x450 (N.S.) 450x450 (N.S.) 450x450 (N.S.) 340 CFM (TYP)
WITH DAMPER SA & RA DIFFUSER SA & RA DIFFUSER SA & RA DIFFUSER
PLEASE PROVIDE VENTILATION SIZE = 780X200
FOR THE LOCKERS ROOM THICKNESS OF SHEET AS PER IS : 655
MINIMUM 300 MM TO BE LEFT FOR
QUENCH PIPE TO TRAVEL THE DISTANCE
Maximum Thickness
UPPER BASEMENT PLAN PLEASE INSTALL THE AHU Size of Sheet (GI)
Gauge
420
AC DUCTING
2660
0 to 750 0.63 24
2240
DRG. TITLE :
AUTOCAD DRAWING FILE REF. :
N
REV. DATE REVISION DESCRIPTION DRW. CHK. APP. ISSUED H-227, BAISHNABGHATA PATULI TOWNSHIP, PINTU SARKAR SCALE : 1:100
Ph.: 033-4001891 / 1892 KOLKATA - 700094
REVISION INDEX email : sreckolkata@gmail.com REV NO. : 0