Professional Documents
Culture Documents
Conpass Smart DV TP 2022
Conpass Smart DV TP 2022
SMART DV
Full Body Scanner
With DruGuard and Optional A.I.
Powered Full Body Threat Detection
CUSTOMER PROSPECT
www.adanisystems.us ADANI patented technology based Full-Body Security Screening
System CONPASS Smart DV is specially designed for use in
0503-SA06022020
Tech Support 844.989.6789 airports, prisons, border terminals, government buildings, as well
13631 Poplar Circle, Support@adanisystems.com as in all other locations which require a detailed examination of
Conroe, TX 77304, USA Sales Inquiries 936.588.2064 the abdominal cavity and natural cavities of the human body
info@adanisystems.com Sales@adanisystems.com without employing specialized medical equipment.
CONPASS SMART DV
ADVANTAGES 1
● An innovative X-ray inspection method of
body screening based on registration of the
low dose X ray electrical signals passing
through the object
● High medical quality of images of abdominal
part of the body using low dose radiation;
2
● Detection of the prohibited objects under the
clothes or inside the body of the person
4
being inspected in 5 seconds
● Highly increased screening efficiency as
compared to metal detectors
● Free from privacy violation issues typical of
backscater X-ray inspection systems, which
“strip” the person being inspected. No need
for multiple scans to obtain front, back or
lateral projections. 3
● Artificial Intelligence (AI) software based on
neural network help operator to find all CONPASS SMART DV SCANNER:
objects, not belonging to human body and
mark them in according to potential risk level. 1 Portal;
2 Enclosure;
3 Moveable platform (or conveyer belt);
4 Operator’s computer.
Explosives, Containers
detonators, Narcotics with biological Electronic Food
wires etc. or chemical devices
materials
SHIELDED OPERATOR
WORKSTATION
A specially developed X-ray protective
shield is an ideal solution ensuring
maximum protection for the operator from
the radiation scattered during the
scanning process, as well as helping to
save money.
The use of the shield is recommended
only when the operator needs to stay
critically close to the system. Passersby
have no access to the area around the
system, so the size of the safety perimeter
around the scanner is of no consequence.
CONPASS SMART DV FEATURES
Inspection method Penetrating X-radiation
Inspection object Full-body inspection as well as separate inspection of abdominal part of the body
Detection objects Prohibited objects of any material, hidden inside any part of the human body
Human body movement method Moveable platform/conveyor (platform move – not less than 2,63ft)
Inspection chamber Open portal. Low height portal option is available
Scanning technique The human body is being moved through the fixed X-ray beam
X- ray beam Movement time 5 seconds (5-15 seconds fully adjustable)
RADIATION SAFETY
Full-Body Scanner (Class A, as in ANSI/HPS
ANSI classification
N43.17-2009), Limited use (for doses more than 0.25 µSv per scan)
DOSE PER SCANNED INDIVIDUAL
Min dose (2500 scans per year) 0,1 µSv / high dense objects / no limits for quantity of scans per year
Low dose (1000 scans per year) 0,25 µSv / small high dense objects / big low dense objects / weapons, explosives etc.
Standard quality (250 scans per year) 1 µSv / small dense objects / small non-dense objects
High quality (125 scans per year) 2 µSv /small dense objects and small non-dense objects in obstruction environment (abdominal
cavity)
4 µSv /extra small (0.15 mm) dense objects and small non- dense objects in obstruction environment
Max dose (62 scans per year)
(abdominal cavity)
Delivered dose control Embedded dosimeters (calibrated during the installation)
POWER FEATURES:
Consumption Max 1.5 kVA
Voltage 230VAC ± 10%, single phase/110-125 VAC ± 10% (50/60Hz)
Possibility to install a boost Can be installed inside the system (in countries with the
transformer lower line voltage (on customer demand))
DETECTABILITY:
Scanning field 6’7” x 2’6” (reduced height configuration)
36 AWG (38 AWG optionally) for full-body image and 40
Min seen wire
AWG (41 AWG optionally) for abdominal cavity image
Penetration Min 34-38 (depending on scanning mode) mm steel
Detector type Linear array, 2.5 or 1.5 mm pixels detector plates for full- body and abdominal images.
Bit count 16 bit
Dual Energy detector (optional) Full-body image can be presented in Dual Energy format, which discriminate materials by atomic
number.
X-RAY TUBE MODULE FEATURES
Generators type Monoblock
GENERATORS PARAMETERS:
Anode voltage 160 kV, 200 kV
0.1-2.25 mA for the 1st generator (full-body image)
Anode current 0.1-2 mA for the 2nd generator (abdominal part image)
ADANI Systems, Inc. All rights reserved. The informa�on in this document is proprietary to ADANI Systems, Inc. It may not be used, reproduced, disclosed, or
exported without the written approval of ADANI Systems, Inc. With con�nual development of our products ADANI Systems, Inc. reserves the right to make
changes to the design and specifica�ons at any moment and without no�ce.
CONPASS SMART DVX-RAY IMAGES
Super Edge Enhancement (S.E.E.)
SOFTWARE UPGRADE
ACCESSORIES
FACIAL INTERCOM TOUCHSCREEN A-EYE
RECOGNITION
CAMERA
SYSTEM PANELS SOFTWARE
UPGRADE DIMENSIONS
NETWORK
MULTI-OPERATOR INTEGRATION
LASER
FUNCTION
PRINTER
www.adanisystems.us
LASER
PRINTER