This standard covers the minimum requirements for special purpose form-wound squirrel-cage induction motors 375
kW (500 Horsepower) and larger for use in petroleum, chemical and other industry applications.
Note 1: Special purpose machines typically have one or more of the following characteristics:
1. Is in an application for which the equipment is designed for uninterrupted, continuous operation in critical service,
and for which there is usually no installed spare equipment.
2. Is larger than 2250 kW (3000 hp) for speeds 1800 RPM and below.
3. Is rated 600 kW (800 hp) or greater for two-pole (3000 or 3600-RPM) machines of totally-enclosed construction, or
rated 930 kW (1250 hp) or greater for two-pole machines of open or guarded construction (including machines with
WP-I or WP-II type enclosures).
4. Drives a high-inertia load (in excess of the load WK2 listed in NEMA MG 1 Part 20).
5. Uses an adjustable speed drive as a source of power.
6. Is an induction generator.
7. Is a vertical machine rated 375 kW (500 hp) or greater.
8. Operates in abnormally hostile environments..
Metal fan-covers
WPII - stainless steel filters & provisions for differential pressure switch
Stainless steel hardware (up to ½“)
Specific mounting surface dimension tolerances
Copper rotors (Aluminum allowable if approved by purchaser) with Phosphorous-free braze material
(Cu bar rotors)
Special rotor balance procedures (Step Balance 2 & 4-poles)
Shaft
Laminated steel core
Rotor bars/short circuit rings
Air duct
Internal fan
External fan
Shaft
Laminated steel core
Copper rotor bars
Copper short circuit rings
High tensile retaining rings
Internal fans
Routine Testing
Coil Surge comparison tests
Soft-foot check must be made prior to any mechanical running test
High-potential test
Polarization index
No-load bearing run + bearing temperature rise
Bearing inspection (sleeve bearings)
Vibration test
RTDs measure “hot spot” temperature Occasionally average exceeds hot spot
RTDs inserted between coils in the slots meaning hot spot is not the worst case
Average temperature determined by Now required to meet the limits by both
change of winding resistance methods
Permitted hot spot rises are 0 to 10°C Ensures temperature limits are met
above average rises throughout windings
New
TEWAC/CACW
TEWAC motors are required to include a flow-sensing device
and air RTD's (into and out of cooler) now as standard (4.4.1.2.4)
New
4.4.5.1.3 Heat-treated forged steel shafts shall be used for machines having any of the following characteristics:
a) finished shaft diameter 200 mm (8 in.) and larger;
b) two pole machine;
c) operation above the first lateral critical speed;
d) driving a reciprocating load; or
e) using a tapered hydraulic fit coupling.
Hot-rolled shafts may be used for all other machines if the vendor can demonstrate a minimum of two years
successful operating experience with the design in that application.
4.4.5.1.4 When specified, the shaft and spider shall be machined from a one-piece heat-treated forging.
4.4.5.1.5 Heat-treated forged steel shafts shall be AISI 4000 series and comply with ASTM A668 or equivalent in EN
10250.
Many new requirements and notes throughout the standard created for ASD
applications and for purchaser information/review of application
When specified, mutually agreed sound level on ASD (4.1.4)
When specified, mutually agreed over-speed capability (4.1.5)
Mutually agreed upon voltage and frequency ratings (4.2.1.2.3)
Starting & Running, new note for ASD starting (4.2.3.3)
Supply from ASD only, starting characteristics can differ from ACL requirements (4.2.4.5)
Note: Rotor and Stator temps
Note: Torsional oscillations from drive harmonics
Note: Damage due to improper application
Purchaser to advise significant ASD harmonic content (4.3.1.2)
Purchaser to advise ASD voltage spikes (4.3.1.2.1) Symbol used to
Purchaser to advise ASD common mode voltage (4.3.1.2.2) identify paragraphs in
Mutually agree on strategy to avoid structure resonances (4.4.2.1.1) 541 with ASD related
Well damped rotor natural frequency if within speed range (4.4.6.1.2) content
ASD CONDITIONS
INDUCTION MOTOR JOB NO. ITEM / TAG NO.
API 541 5th Edition -- DATA SHEETS PURCHASE ORDER NO.
U.S. CUSTOMARY UNITS REQ. / SPEC. NO.
PURCHASER'S SELECTIONS REVISION NO. DATE BY
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE 1 OF 12 Rev
1 USER APPLICATION
4
LOCATION
SITE / PLANT
m SUPPLIER
Adjustable Speed Drive (ASD) Conditions, if applicable (4.1.4; 4.1.5; 4.2.1.2.3, 4.3.1.2):
Bold Italics = Indicate the Standard's Default Selection - Refer to Annex C for Data Sheet Guidance
m m m
6 Applicable Standards (1.3.2; 2.0): North American (i.e., ANSI, NEMA) Use SI (metric) data sheets for International Standards (IEC, etc.)
m m m
ASD only operation (4.2.4.5)
7
8
Power / RPM Ratings are Specified by:
HP
Other
m 40 o C m m
O O
10 Nameplate Ambient Temp. Rating (4.3.1.1,b): Other: C Minimum Rated Operating Ambient Temp.(4.1.2): C
m
13 Duty (4.1.2): Continuous m Other:
15
Max. Sound Pressure Level @ 1 m. @ no load, full voltage/frequency on sine wave power (4.1.3; 4.1.4):
m
Voltage and Frequency Variations (4.2.1.3): Per NEMA Other:
85 dBA m Other:
RPM dBA
m m
m
16 Motor Power Source: Sine Wave Power ASD Power (complete below section) Solid State Soft Starter - Complete data on page 6, line 8
17 Adjustable Speed Drive (ASD) Conditions, if applicable (4.1.4; 4.1.5; 4.2.1.2.3, 4.3.1.2):
Constant Power Speed
m
18 Range:
m Max Speed
m
ASD only operation (4.2.4.5) ASD+DOL Start capability ASD only w-Bypass to Utility Power m ASD w-DOL Start & Bypass to Utility RPM ft-lb
19 m Variable Torque Speed Range: Min Speed RPM ft-lb Max. Speed RPM ft-lb
20 m Constant Torque Speed Range: Min Speed RPM Max. Speed RPM ft-lb
ASD Description and Information affecting motor design (Obtain from ASD Supplier; refer to Data Sheet G
21
22
m Constant Power Speed Range: Max Speed RPM ft-lb
ASD Description and Information affecting motor design (Obtain from ASD Supplier; refer to Data Sheet Guide)
25
ASD Output Harmonics, describe and/or attach data (4.3.1.2):
ASD Maximum Voltage Spike Amplitude and Rise-Time at drive output (4.3.1.2.1): Volts @ microseconds
26 ASD Maximum Common Mode Voltage (CMV) at drive output (4.3.1.2.2): Volts
29 Area Classification (4.1.8): m Nonclassified m Classified as: Class Group Division or Zone
o
30 Temperature Code (T-code): Autoignition Temperature (AIT): C
32 Site Data (4.1.2; 4.4.8.3; 4.4.10.4): Site Ambient Temperature: Max Min m O
F m O
C
O
33 Minimum Rated Storage Ambient Temp.(4.1.2): C Site Elevation: ft.
m
35
Voltage (CMV)
m m
m at drive output (4.3.1.2.2):
Relative Humidity:
No
Use Higher Elevation for motor rating:
36 m Outdoor Roof Over Motor: m No m Yes m Offshore Platform / similar marine environment (4.4.1.1.c)
37 m Seismic Loading (4.4.2.2), IBC Zone: Importance Factor: m Other Seismic Requirements:
Other ASD information / motor requirements:
38 Unusual Site Conditions, Define:
42 Other:
43
an off-line partial discharge test shall be performed on the stator windings, in accordance with Clause 10.2
of IEEE 1434 or IEC TS 60034-27.
Test voltage shall be 120 % of the rated phase-to-neutral voltage, maintained for at least five minutes.
The vendor shall provide the purchaser with partial discharge test data of similar machines with the same
insulation system for comparison. The acceptance criteria shall be mutually agreed upon between the
vendor and purchaser prior to performing the tests.
New
1 USER
Instructions
Refer to the Data Sheet Guide for comprehensive guidance on all content within this data sheet, which is greatly revised from the
PURCHASER'S SELECTIONS REVISION NO.
Bold Italics = Indicate Default Selection
INDUCTION MOTOR
API 541 5th Edition -- DATA SHEETS
DATE
prior edition of API 541. The Purchaser and/or their representative is responsible for selections, data and revisions in Pages 1-7.
REV. DATE
JOB NO.
APPLICATION
PURCHASE ORDER NO.
PAGE 1
ITEM / TAG NO.
BY
OF 12 Rev
INDUCTION
API 541 5th Edition STATOR
MOTOR
-- DATA
U.S. CUSTOMARY UNITS
SHEETS
WINDING
JOB NO.
AND ROTORPURCHASE ORDER NO.
REPAIR DATA
REQ. / SPEC. NO.
1 Stator Coil Information (8.6.2.d, reference Appendix G): Coil Dimensional Drawing No.:
Page 3/4 Motor Supplier Order Data REVISION NO.
ITEM / TAG NO.
DATE BY
The Supplier / Vendor and / or Manufacturer is responsible for selections, data and revisions on page 8 - PROPOSAL DATA, where 2 Total Copper Weight: lbs. Copper Strand Size: Insulation:
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE 11 OF 12 Rev
3 2 LOCATION U.S.
the Supplier is to provide details about their CUSTOMARY UNITS
offer.
SUPPLIER
REQ. / SPEC. NO.
3 Number of Strands per Coil Turn: Number of Turns per Coil:
3 PROJECT NAME PURCHASER'S SELECTIONS REVISION
SUPPLIER REF. No. NO. DATE BY m INDUCTION AS-DESIGNED
MOTOR m JOB NO.
AS-BUILT ITEM / TAG NO.
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE 2 OF 12 Rev 4 Turn Insulation Description:
4 SITE / PLANT
The Supplier / Vendor and / or Manufacturer shall complete pages 9-12 - MOTOR ORDER DATA, where the AS-DESIGNED symbol NUMBER of UNITS REQUIRED API 541 5th Edition -- DATA SHEETS
ACCESSORIES & PURCHASE
SETTINGS ORDER NO.
BASIC after DESIGN - Enclosure, Mounting, Electrical 5 Ground-Wall Insulation Description:
4 is to be selected for initial
5 Applicable m
To: transmittal m
Proposal of thePurchase DS to m the Purchaser
INDUCTION m
As Designed MOTOR order
As Built placement, MOTOR and TAG
JOB the AS-BUILTsystem
No.(s)
NO. symbol selected ITEM for/ TAG
finalNO. 1 Heaters:
U.S. CUSTOMARY UNITS
Single Voltage Design:
REQ. / SPEC. NO.
Dual Voltage Design:
transmittal with
1 any applicable
Enclosure changes following motor shipment to the Purchaser.
(4.4.1.2) 6 Thickness Turn Insulation: mils 2/4
Page Thickness
MotorStrand Supplier Insulation:
Order Data mils Thickness REVISIONGroundwall
NO. Insulation:
DATE mils BY
API 541 5th Edition -- DATA SHEETS PURCHASE ORDER NO. 2 Operating Voltage kW Phase Operating Voltages kW Phase Sheath Material
Bold Italics = Indicate the Standard's Default Selection - Refer to Annex C for Data Sheet Guidance N.A. REV. DATE PAGE 10 OF 12 Rev
2 m WP-II (Weather Protected Type U.S.II)CUSTOMARY
(4.4.1.2.2) m UNITS
WP-I (Weather Protected
BASIC DESIGN - General
REQ.Type m
/ SPEC. NO.
I) (4.4.1.2.2) DPG (Dripproof Guarded) (4.4.1.2.2)
m
7 Coil
3
Configuration: Rows by
Frame Heaters (5.4.1; 5.4.2; 5.4.3):
Bold Italics =
ColumnsIndicate Default Selection
/
PURCHASER'S
m SELECTIONS REVISION NO.
m DATE BY 8 m
Finished Coil Dimension in Slot, W x H x L (also give tolerances): AS-DESIGNED m AS-BUILT
Purchaser requirements
To minimize 3duplication, Air Filters:
a singleRequiredData Sheet for WP-IIand set (5.5.3)
of requirements Provisions
should be Only for WP-I
utilized foror DPGcommon
each (5.5.2) (same power, Provide filters for WP-I or DPG (5.5.4)
voltage, INDUCTION MOTOR
N.A.
6 etc.)
Applicable Standardsfor (1.3.2; 2.0):
Bold NorthItalics American
= Indicate (i.e., ANSI,
Default NEMA)
Selection UseofSIthe REV.
(metric) DATE
dataofsheets for International PAGE
Standards (IEC,3 etc.) OF 12 Rev m 4 Main T/Box Heaters: / JOB NO. ITEM / TAG NO.
5
enclosure, 4
rating intended the same application,
Air Filter Capability (5.5.4): 90% of particles > 10 micron
service or
m
load, regardless Other:
number units. If there are any different
m
9 Total Number of Stator Slots: API Winding
541 5th Throw:
Edition -- BEARINGS, DATA SHEETS HOUSINGS AND Winding
SEALSConnection:
PURCHASE ORDER NO.
requirements
7 within /aRPM
Power serviceRatings (e.g. aret/box locations,
Specified m
by: direction User/Project m
of rotation, etc.), m OEM
BASIC a separate
DESIGNOther -Data
Bearings,SheetSeals should be used for any unit(s) 5 Bearing Heaters (4.4.8.3):
m U.S.Side CUSTOMARY mils UNITS
/
m
5
with even a single m
difference. Purchaser Specified Filters: INDUCTION Manufacturer: MOTOR JOB
Type: NO. ITEM
Model: / TAG NO. 10 Slot Filler Description
1 Bearings: - Thickness:
Type: Top Hydrodynamic mils (4.4.7.1.1) Middle milsREQ.Slot/ SPEC.
Antifriction
NO.
Dimensions:
(4.4.7.1.3) AFBMA Number(s):
8 Nameplate
1 Bearings: Power Horizontal
Rating (4.2.1.1): Machines
API 541 5th Edition -- DATA m m HPSHEETS kW PURCHASE Motor Speed: RPM (Synchronous) 6 Temperature Detectors:
m
Page 1/4 Motor Supplier Order Data REVISION NO.
m
DATE
m
BY
6 Differential Pressure Device (5.5.5): Provisions Required for WP-II m ORDER NO.
m
Differential Pressure Switch (5.5.5) Combination
11 Slot Wedge2Material:
N.A.
Split Sleeve (4.4.7.1.1) Magnetic Slot Wedges:
REV. DATE
Drive End: No
PAGE
Yes
9 OF 12 Rev
9 Nameplate
2 Bearing Voltage/Ph/Hz
Type: HydrodynamicRating (4.2.1.2): m
U.S. CUSTOMARY
(4.4.7.1.1) UNITS
Volts
Sleeve (4.4.7.1.1) m REQ.
Phase
Tilting Pad/ SPEC.
(4.4.7.1.1)NO. Hertz
mm
7 Winding Temperature Detectors (5.2):
Bold Italics = Indicate Default Selection
RTD-Platinum, 3 Wire, 100 Ohms at 0°C (5.2.1.1) No.per Phase (5.2.1.2): Three (3) m Other
6
Some items may 7 have an option for 'Supplier Decision'. This m is intended
Provisions Only for to give m
WP-Iclear or DPG guidance
(5.5.5) and direction DifferentialtoPressure the Supplier Gaugewhen (5.5.5) Switch / Gauge 12 Stator Bore3Diameter: Tilting Pad (4.4.7.1.1)
m
Stress Grading Description if Applicable: Opposite Drive End:
m
the Purchaser has
3 no other preference. mm
PURCHASER'S o SELECTIONS
m O REVISION NO. DATE BY O
m Resistance:AS-DESIGNED AS-BUILT m
Design/As-built
10 Nameplate Ambient Temp. Rating (4.3.1.1,b): 40 C Bearing Other: Constant-Level Oilers C Minimum
Required Rated Operating
(4.4.7.2.2) Type: Ambient Temp.(4.1.2): C 8 Other RTD Material: Wires: No.per Phase (5.2.1.2): Three (3) Other
8 N.A. m Purchaser Specified Device: Bold Italics Manufacturer:
= Indicate Default Selection Type:DATE
REV. Model:
PAGE 4 OF 12 Rev 13 Special End-Turn
4 Bracing:
Hydrodynamic m
Bearings: Oil Rings Included (4.4.8.1) m Yes No
11 Stator
4 Insulation Class (4.3.1.1,a): m
m
Class F Other Class:(4.4.7.1.3)
Antifriction m 9 One Common1 USER Lead Each Element Grounded in Box. (5.2.1.2)
m m
APPLICATION
Each item on9 each page can be
Enclosure for referred
motors rated to by 6kV it'sand page above:number (in header
(4.4.1.1,f): TEFC,in the upper
TEAAC,
ACCESSORIES right
or TEAAC of(IP44
- Main each m
orpage),
Terminal higher) Boxline number
or (down
Use the
enclosure selected in line 2 14 Other: 5 Bearing, Drive End: Capable of Self-Lube Yes No Manufacturer Model / Part No.
7
left side12 5
Stator
of each m
Temperature
page), or Rev.Other: Rise (4.3.1.1,b)
number (in header *: Class m
andBdown INDUCTION theOther:
right sideMOTOR of each page). * (SeeJOB NO. sentences in Data Sheet
underlined ITEM / TAG
Guide forNO.
this item) m 10 2 LOCATION
Thermocouples: Type: SUPPLIER m
No.per Phase (5.2.1.2): Three (3) Other
10 m 1TEFC Main(4.4.1.2.3)
Terminal Box (5.1.1): m m TEPV
Box Size: (4.4.1.2.3)
Minimum--sizeDATA is per NEMA Other Enclosure:
MG 1-20 Type II with Copper BusNO. Bar & Standoff Insulators Required 15 Rotor Information: 6 BoreTotal
Diameter: Min Weight:
Conductor in. Max lbs. Number of Bars: in. Bore Length Strand or Bar Size: in. Type
13 Duty (4.1.2): Continuous m API Other:541 5th Edition SHEETS PURCHASE ORDER
m 11 Other 3 PROJECT NAME SUPPLIER REF. No.
11 6 Bearings:
2 Instructions
Other Size: m
Vertical Machines
Supplier
Heat m mm
ExchangerStd.for U.S. CUSTOMARY
Req'd.Accessories
Tube Aluminum UNITS m m
Alum.
For Shielded Alloy Copper
REQ.m
m m
Cable Term.(5.1.6, / SPEC. Copper
e) NO. AlloyOther: Other 16 Conductor 7 Design
Material: Clearance with Shaft: Ring Min
Material: in. Max Retaining Ringin.Alloy, If Applicable: Bearing Loading: PSI
8
14 m
Max. Sound TEAAC (4.4.1.2.3)
Pressure Level @ on 1 m. how @ noto load,use full data sheet symbols
voltage/frequency on sine wave topowermake selections
(4.1.3; 4.1.4): 85 dBA Other: dBA 12 4 SITESettings:
Recommended / PLANT Alarm: Shutdown: NUMBER of UNITS REQUIRED
12 7 3 Box Location Thrust Materials
facingBearing
mm m m PURCHASER'S
(4.4.10.8,
non-drive Downthrust
end:
a): Momentary SELECTIONS
LeftStainless
Side SteelRightm
300 Series
Side
lbs
REVISION NO.
Stainless
Other: Steel Upthrust m
316 Series Momentary DATE req'd for offshore)
(4.4.10.8, lbsBY
Thermal Insulation (5.1.6, a) 17 Shaft 8Material:
Bearing, Non-Drive End: Capable m
Ring ofDimensions m
Self-Lube Premachining:
Yes No Manufacturer Model / Part No.
Some of15the paragraphs
13
Voltage and
8
m
N.A.Frequency
4TEWAC Cable
Load
in the Standard
(4.4.1.2.4)
Variations
Enter From
(4.4.7.1.11,
require
Heat
(4.2.1.3):
mm m m
a)Bold
a Purchaser
Exchanger Bottom
(5.1.4.1):
Per NEMA
Italics = Decision
Indicate
Tube Materials Continuous
Other:
or
Default
Top(4.4.10.8,
are Selection
Optional. These arelbs
mm m
b):End 90-10SideCu-Ni
REV.
indicated
m
DATE by a solid
Other
round bullet PAGE
Continuous 5 lbs OF 12 Rev 13 Bearing 5
Temperature Detectors (5.3): One (1) Per Bearing Hydrodynamic, Thrust mBearings MOTOR Other TAG No.(s)
Qty / Bearing m Dual Element
next to the
16 paragraph in the Standard. This data sheet uses ASD openPower bullets to Drive
identify those items that Non-Drive fit this End Side
convention. Quick Disconnect
Soft StarterChanging
- Completethe
Studs or Receptacles (5.1.6,f) 9 Bore Diameter: Min in. Max in. Bore Length in. Type
9 Motor Power
bullet to a solid 9
14 bullet on the
5 Coolingm
Source:
Other:
Incomingdata
Sine Wave
sheet
WaterConductor
Conditionsindicates
Power
m
Size: the Purchaser
per 4.4.1.2.4, a: Type requires
(complete
Water & glycol an item
below
m
section)
ACCESSORIES
or that the item appliesOther
solution
Insulation
Solid State
toQty. m
thecooling
Purchaser's
Per Phasewater conditions (attach
data on page 6, line 8
documentation)
Provision for Purging (5.1.6, c)
m 18 Notes:
14
10
RTD - Platinum, 3 Wire, 100 Ohms at 0°C (5.3.1)
Design Clearance with Shaft:
m Min
MOTOR m
ProvisionsRATING
in. Max
Only - ELECTRICAL
Install perAND
in.
m
PERFORMANCE
API 670 (5.3.1) DATA
Ground One Common Lead
Bearing Loading: PSI
17
requirements Adjustable
for the machine. 1SpeedHeaters:
m m
Drive (ASD)Frame Conditions,
m m m
Space if applicable
Heaters (5.4.1; (4.1.4;5.4.2;4.1.5;5.4.3): m
4.2.1.2.3,
m Sheath 4.3.1.2):
Material: m Supplier Decision Other: m 19
15 Other RTD 6 Material:
Quantity Type Wires:
/ Model No. m
Frame Size / Designation m
Other info: Motor Power: m
Utility-Grid ASD
15 10 Seals:
m
6 Cooler Location-orientation
All Phase Special
Leads Seals In Terminal (4.4.1.2.4,
for Gas BoxPurge c): (4.4.7.3.a)
(4.3.6): Supplier750kW
Required Decision (1000HP)Above
Non-conducting Stator(4.4.7.3,
Seals
and larger Other
b)
Provide m
in < 750kW (1000HP) Removable Links (5.1.6, d)
m m
Resistance:
m
18 ASD 2 only operation (4.2.4.5) m
m m ASD+DOL StartDesign
capability Operating ASDVoltage m
only w-Bypass to Utility Power ASDPhasew-DOL Start & Bypass to Utility
m 20 11 Special Seals for Gas Purge (4.4.7.3, a)
m
Non-conducting Seals (4.4.7.3, b)
m
Other Seal Type
mm mm m mm mm
Single Voltage 16 7 Nameplate
Thermocouples: Type: Power / RPM Rating (4.2.1.1): HP kW RPM Full Load RPM Synchronous Poles
16 7 Cooler OnInlet-Outlet
Copper lineBus5, select
Jointlocation
the
Plating or(facing
(5.1.6,NDE):
applicable bullet
i): to indicate Supplier
Supplier the Decision
status
Decision of the data Right
Silver sheet.Side TheTin LeftNone
initial state Side
is 'Proposal',Other andCopper
it should Ground Bus (5.1.6, k)
10 19Page 1 m
11 Other:
Variable Torque Speed m
Range: Min Speed RPM ft-lb Max. Speed
/ Bus Bar between RPM ft-lb
m 21 12 m
Thrust Bearing: Antifrictionm (4.4.7.1.5)
m
Hydrodynamic (4.4.7.1.10) Bearing
m
Loading:
m PSI
17
12 8
3 be changed to 'Purchase' to indicate
m
Tube Construction (4.4.1.2.4, d;
Insulated Terminations mm Dual Voltage
and4.4.10.8,
a finalDesign
c):
Interior Jumpers
revision and
Single Tube
(5.1.6.m)
Operating
m
purchaseVoltages of the machine is underway.
Double
6kV & Tubeup use Insulated Redundant
Phase
Coolers (4.4.1.2.4,
Stator Windings b) INDUCTION MOTOR
and Main Terminals (4.3.9)
JOB NO. ITEM / TAG NO. 17 Dial Type8 Thermometers
Nameplate Voltage/Ph/Hz
(4.4.7.1.16): Rating Type (4.2.1.2): Volts (4.2.1.2)Alarm Contacts Number Phaseof Contacts Hertz NO NC
20 m Constant m
Torque Speed Range: Min Speed(4.4.8.3): RPM Max. Speed APIRPM 541 5th Edition ft-lb-- DATA SHEETS
INDUCTION MOTOR PURCHASE ORDER NO. 22 13
m
Thrust Bearing Momentary lbs Momentary lbs
11 Pages 4
m
181 - 6 9 LeakThroughout Detection
Main T/Box these
(4.4.1.2.4,
Space
Bearing
pages,
m
Heaters
c): select
Heaters Required and change
(5.1.6, b):For Double to solidTube Operating
theSingle
bullets
Coolers: thatVoltage
apply
Inner
Voltage to the
Tube
Design Purchaser's
Leak m
Detection
Operating requirements.
Required
Voltage
Phase
Outer Tube Detection also Phase
JOB NO. ITEM / TAG NO. 18 9 Insulation
Antifriction bearings: Class (4.3.1.1,a):
Load Above
Capability
Class F
selectionsDownthrust Temperature
applied to Antifriction bearings Rise (4.3.1.1, b): Class B
Upthrust
Enclosure (4.4.1.2):
21 m Constant5 Power Speed Range: m Max Speed or BASIC
RPM DESIGN - Bearing ft-lbLubrication U.S. CUSTOMARY API 541 UNITS5th Edition -- DATA REQ. /SHEETS
SPEC. NO. PURCHASE ORDER NO. 23 14 (4.4.7.1.11) Continuous at: Locked-Rotor (LRT) lbs Pull-Up Continuous Breakdown (BDT) lbs
m m
Main Terminal Box Space Heaters required: also see Main Terminal Box section, page 4
19 10 FlowSelect Referand
Sensor to page
with Local
change 5 for to heater
Indicator
solid the T-Code,
bulletsetc.
(4.4.1.2.4, g): apply
that Required
to the Purchaser's
Dual Voltage Not requirements
Required
Design m
for Analysis,
Operating Relay Contacts:and Testing
Inspection
Voltages m
Norm.Open /as
PURCHASER'S Norm.Closed
PhaseSELECTIONS
INDUCTION MOTOR JOB NO. ITEM / TAG NO. 19 10 Full-Load
Recommended Torque
Settings: (FLT)
Alarm: ft-lb Percent FLTShutdown: (PUT)
22 13 Description
ASD Hydrodynamic Forand Bearings:
Information
Classified Areas Ring Type
affecting
provide motor Self Lubrication
design (Obtain (4.4.8.1)
from toASD Supplier; T3refer onlytowhenData Sheet Guide)ifrequires
U.S. CUSTOMARYREVISION UNITS NO.
API 541 5th Edition -- DATA SHEETS
REQ. DATE
/ SPEC. NO. BY
PURCHASE ORDER NO. 24 15 m m
Non-Drive Endfollowing Drive EndManufacturer Model / Part No.
12 Page
20 7 m
6 described
Purchaser
above.
Specified
Additionally,
Device:
changeTemp. theCode
Manufacturer:
triangle (from bullet
pg.1): a solid triangle used for
Type: N.A.
the
labeled Purchaser
heaters all units of a
not specified
Model: Bold Italics = Indicate PURCHASER'S
Default Selection SELECTIONS
REV. DATE REVISION NO. PAGE 6 DATEOF 12 Rev BY
11 Expected Data (8.1.3,f)
20 Enclosure Accessories at the Loads (100% Voltage):
m m
11type For Temp.
multi-unit
the devices Code
order and/or
to
following Max.
receive Surface
below, the applicable
the Purchaser inspection
may make orSupplier
test. Leaving
a Provide-Install the triangle
selection; bullettheopen defaultindicates
is Providethe inspection
and Install orby Supplier : o
23 14
ASD Type/Viscosity
7 /test
topology: of Oil (4.4.8.5; 4.4.8.8; 5.1.4.2) Decision o Other, Define: U.S. CUSTOMARY UNITS REQ. / SPEC. NO. 25
Temp. (5.4.2):
Cooler Airapplies Inlet &only to one Max.
unit of a multi-unit Surface
order. Temp.:
m C
m
(less than or equal to 80%
m of AIT on pg.1 for
Same as WindingN.A. Other
unlabeled heaters, 160 C if AIT not specified)
Bold Italics = Indicate Default Selection CONDITIONS REV. DATE PAGE 7 OF 12 Rev
21 WP-II, 12 Load Point:
WP-I, DPG/ODP (4.4.1.2.2)
Locked-Rotor
m 50%
Air Filters:
LUBRICATION
75% SYSTEM 100%
Provided (5.5.4): Required for WP-II (5.5.3) m Other: % Data is:
Air Filters Not Provided (5.5.4)
mm
21 Outlet Temperature Sensor (4.4.1.2.4, h): Required Not Required
InstalledLOAD REQUIREMENTS AND STARTING MOTOR PROPOSAL DATA REVISION NO. DATE BY
24 15
ASD 12Output DifferentialLube
Pressurized
Harmonics, Protection
Required
describe Current
and/or (4.4.8.4)Transformers
attach m
data (4.3.1.2): (5.1.6,Commonh; 5.1.8; With 5.6.3) Driven Equipment (4.4.8.5) Provided By
m
and By
m26
m m
22 8 m
8 The Supplier,
Winding
Purchaser Vendor and/or
Temperature
m Specified Manufacturer
Detectors
Device:
mm
(5.2): isRTD
Manufacturer: to complete
- Platinum, this 3page,
Wire,using
m m
100 Ohmsthe bulletsat 32°F
Type: to indicate
(5.2.1.1) items applicable Other to
Model:RTD theirMaterial:
Requirements (4.2.2): N.A. m ANALYSIS,
orBold Italics
SHOP INSPECTION,Selection
= Indicate AND TESTS
load curve & data (4.2.2.1,a) REV. DATE
specifiedDefault PAGE 22 8
16 13Hydrodynamic
OFCapability
Filter Efficiency:
12 (5.5.4):Rev90% of particles% m
Bearing Ring Type Self Lubrication
> 10 micron %
Other
(4.4.8.1) %
m
Constant-Level
% Oilers (4.4.7.2.2)
% Provisions Only
Air Filter Calculated
(5.5.2)
42
38 Other Monitors and Devices
mm Copies of Applicable Certifictions, including NRTL, Material Certications (including PMI), 30 Coupling:
and other Specified m
Certifications By: 31 m
for the machine(s)Purchaser
m
m
Rated Rotor Temperature-Vibration
(8.7.6)
29
m m
Driven Test (6.3.5.2.1)
Equipment m
Supplier(If notCapability
Load using Complete
Motor SupplierTest)
Downthrust
Momentary
v 671
Per API v lbs
Upthrust v
Momentary lbs
41 Alarm and Control Switches (5.6.1): SPDT 10 Amp 120VAC & 125VDC m Other:
33
m m
34 Overspeed Test (6.3.5.6; 4.1.5) m 32 m Pressurized Lube mSystem
Motor Half-Coupling Mounted By (4.4.9.4): (requires vibration test in 6.3.1.5 when Motor Supplier mounts half-coupling)
(4.4.8.4) Common With v
Driven Equipment (4.4.8.5) v System mSupplied By vm
(4.4.8.4): Others Motor Supplier
42 Auxiliary Equipment T-Boxes (5.1.4.1): Location of Aux. Boxes (facing non-drive end): m m 34
mm Left Side
m
Right
35 Side
m
Final Rotating Other: m
Assembly 33
m
Purchaser
ClearanceType/Viscosity of Oil (4.4.8.5;
data storage (6.2.1.1,
Driven Equipment Supplier
e) 4.4.8.8; 5.1.4.2):
Motor Supplier Other:
v m m
Oil rings Included Yes No
43 m Stainless Steel Aux. Boxes/Encl. (5.1.4.1) Cond./Cable Entry (5.1.4.1, 5.1.13): m m m Bottom Left or 36 RightRadiographic m
Side facing non-drive m
34 end2 Define
Test (6.2.2.2), Oil Requirements
Parts: mper Bearing (8.1.4): Flow: 2 v GPM v
Pressure: vPSI Volume: QTS
Material Inspection (6.2.2)
35 Coupling Inertia (4.2.2.1, c): Wk : lb-ft2 or GD2: kg-m (To be included in Total Inertia above)
44 Accessory Equipment Wiring Outside Enclosure (5.1.11): Rigid Conduit m Other:
36 Mass Moment37 of Coupling Ultrasonic m
inspection of
Half (4.4.6.2.1.1,f
35
m
): shaft forging (4.4.5.1.8; m
lb-ft2 6.2.2.3)
or
Heat Loss
kg-m2 (For v
To Be Removed per
damped unbal. response
Bearing:
vanalysis) kW
v
37 38
m
Ultrasonic m
Test (6.2.2.3),
Center of Gravity of Coupling Half - drawing reference or dimensions (6.3.5.3): m m
36 Oil Mist Provisions (4.4.7.4) (see Guide):
Define Parts: m Purge Oil Mist, Hydrodynamic Brg's
v v m
Pure Oil Mist, Antifriction Brg's
v
Oil Mist Ready, Antifriction Brg's.
38 Other Information: 39 m
37 Other:
m
Magnetic Particle Test (6.2.2.4), Define Parts:
m m v v
Grease, Type:
v
38 Magnetic Stator Slot Wedges Used (4.3.10): m Yes mvNo
39 Vertical Pumps: 40 Liquid Penetrant TestMomentary
Thrust Bearing
(6.2.2.5), Define Parts: lbs mMomentary m v lbs m v
Downthrust39 When Enclosure Pre-Start Purging is specified,
Upthrust
vendor defined maximum allowable pressure (4.4.1.1, e):
40 Load 41
(4.4.7.1.11, a)
Hydrostatic Test (6.2.2.6), Define Parts:
Continuous lbs m v
Continuous m v lbs m v
40 Low Ambient Temperature Precautions (4.4.10.4):
41 Other Information: 42 Certified Data Prior to Shipment (8.6.2, a) m v
41 Special Winterizing Requirements (8.1.15):
42 43 All Required Test and Inspection Equipment (6.1.4) Provided by Supplier
42 Machine Net Weight (8.1.5):
m Other:
lbs.
44 Notes:
43 Special Tools Included in Proposal (4.1.11, 8.1.13):
44 Machine Proposed is in Strict Compliance with API 541 5th Edition? (8.1.9) m Yes m No m List of Applicable Exceptions Attached
Revised
Refer to the Data Sheet Guide for comprehensive guidance on all content within this data sheet, which is greatly revised from the
2
prior edition of API 541. The Purchaser and/or their representative is responsible for selections, data and revisions in Pages 1-7.
The Supplier / Vendor and / or Manufacturer is responsible for selections, data and revisions on page 8 - PROPOSAL DATA, where
3
the Supplier is to provide details about their offer.
6
3) Press enter or click onto next item
Some items may have an option for 'Supplier Decision'. This is intended to give clear guidance and direction to the Supplier when
the Purchaser has no other preference.
m l
8 Instructions on how to use data sheet symbols to make selections
to lower case " l " Changes an item from default or not required to an item that is required
Some of the paragraphs in the Standard require a Purchaser Decision or are Optional. These are indicated by a solid round bullet
next to the paragraph in the Standard. This data sheet uses open bullets to identify those items that fit this convention. Changing the
9
bullet to a solid bullet on the data sheet indicates the Purchaser requires an item or that the item applies to the Purchaser's
l m
requirements for the machine.
to lower case " m "
10 Page 1
Changes an item from being required to the default or not required
On line 5, select the applicable bullet to indicate the status of the data sheet. The initial state is 'Proposal', and it should
be changed to 'Purchase' to indicate a final revision and purchase of the machine is underway.
22 l to m lower case " m " Changes an item from being required to the default or not required
1 USER APPLICATION
2 LOCATION SUPPLIER
m m
3 PROJECT NAME SUPPLIER REF. No.
5 m
SITE / PLANT
Bold Italics = Indicate the Standard's Default Selection - Refer to Annex C for Data Sheet Guidance
Adjustable Speed Drive (ASD) Conditions, if applicable (4.1.4; 4.1.5; 4.2.1.2.3, 4.3.1.2):
6 Applicable Standards (1.3.2; 2.0): North American (i.e., ANSI, NEMA)
BASIC DESIGN - General
m 8
10
m
Nameplate Power Rating (4.2.1.1):
Other:
HP m
O
C
kW
m
Phase
Motor Speed:
Hertz
O
C
ASD only w-Bypass to Utility Powe
m
11 Stator Insulation Class (4.3.1.1,a): Class F m Other Class:
13
m
Stator Temperature Rise (4.3.1.1,b)*: Class B
Duty (4.1.2): Continuous Other:
Other:
RPM
* (See underlined sentences in Data Sheet Guide for this item)
ft-lb
m
m
14 Max. Sound Pressure Level @ 1 m. @ no load, full voltage/frequency on sine wave power (4.1.3; 4.1.4): 85 dBA Other: dBA
15 m
Voltage and Frequency Variations (4.2.1.3): Per NEMA Other:
Constant Torque Speed Range: MinmSpeed
16 Motor Power Source: Sine Wave Power ASD Power (complete below section) m RPM
Solid State Soft Starter - Complete data on page 6, line 8
17 Adjustable Speed Drive (ASD) Conditions, if applicable (4.1.4; 4.1.5; 4.2.1.2.3, 4.3.1.2):
m
18 m ASD only operation (4.2.4.5) m ASD+DOL Start capability m ASD only w-Bypass to Utility Power m ASD w-DOL Start & Bypass to Utility
Constant Power SpeedmRange: Max Speed
19 Variable Torque Speed Range: Min Speed RPM ft-lb Max. Speed RPM
RPM ft-lb
ft-lb
20 m Constant Torque Speed Range: Min Speed RPM Max. Speed RPM ft-lb
ASD Description and Information affecting motor design (Obtain from ASD Supplier; refer to Data Sheet Guid
22
23
ASD Description and Information affecting motor design (Obtain from ASD Supplier; refer to Data Sheet Guide)
25 ASD Maximum Voltage Spike Amplitude and Rise-Time at drive output (4.3.1.2.1): Volts @ microseconds
ASD type / topology: 26 ASD Maximum Common Mode Voltage (CMV) at drive output (4.3.1.2.2): Volts
28
30
m mattach data (4.3.1.2):
Area Classification (4.1.8): Nonclassified Classified as: Class
33
m m output (4.3.1.2.1):
Site Data (4.1.2; 4.4.8.3; 4.4.10.4):
Site Elevation:
Min
ft.
O
F O
C
34 Relative Humidity: % Max % Min m Use Higher Elevation for motor rating: ft.
42 Other:
43
1 Enclosure (4.4.1.2)
m m m
Enclosure for motors rated 6kV and above: (4.4.1.1,f):
2
3
WP-II (Weather Protected Type II) (4.4.1.2.2)
6 Differential Pressure Device (5.5.5): Provisions Required for WP-II m Differential Pressure Switch (5.5.5) m
TEFC, TEAAC, or TEAAC (IP44 or higher)
Combination
7
Manufacturer:
m
Type:
Differential Pressure Gauge (5.5.5)
Model:
Switch / Gauge
or
9 Enclosure for motors rated 6kV and above: (4.4.1.1,f): TEFC, TEAAC, or TEAAC (IP44 or higher) or m Use enclosure selected in line 2
11 Heat Exchanger Tube m Aluminum m Alum. Alloy m Copper m Copper Alloy m Other
m TEAAC (4.4.1.2.3)
12 Materials (4.4.10.8, a):
m Stainless Steel 300 Series m Stainless Steel 316 Series (4.4.10.8, req'd for offshore)
13 m TEWAC (4.4.1.2.4) Heat Exchanger Tube Materials (4.4.10.8, b): 90-10 Cu-Ni m Other
14 Cooling Water Conditions per 4.4.1.2.4, a: m Water & glycol solution m Other cooling water conditions (attach documentation)
16 Cooler Inlet-Outlet location (facing NDE): m Supplier Decision m Right Side m Left Side m Other
17 Tube Construction (4.4.1.2.4, d; 4.4.10.8, c): Single Tube m Double Tube m Redundant Coolers (4.4.1.2.4, b)
18 Leak Detection (4.4.1.2.4, c): Required For Double Tube Coolers: Inner Tube Leak Detection Required m Outer Tube Detection also
19 Flow Sensor with Local Indicator (4.4.1.2.4, g): Required m Not Required Relay Contacts: m Norm.Open m Norm.Closed
m
22
System Cooler Air Inlet & Outlet Temperature Sensor (4.4.1.2.4, h):
Type:
Same as Winding
Model:
Other
23 Alternate Enclosure Identification (4.4.1.2.1) m Degree of Protection (4.4.1.2.1) IP m Method of Cooling (4.4.1.2.1) IC
25
26 m
Hardware-Fasteners Material (4.4.1.1.c): Stainless Steel 300 Series through M12 (1/2 in.)
Provision for Pre-Start Purging (4.4.1.1, e): Purchaser Specified Purge Details:
Purchaser
m Specified Paint Color
SS 316 Series through 1/2 in. for offshore
30 Paint System: Supplier's Paint System m Purchaser Specified Paint System Paint System Specification:
31 Paint Color: Supplier's Paint Color m Purchaser Specified Paint Color Define Paint Color and Code:
32 Mounting: m Horizontal Foot Mounted m Horizontal Flange Mounted with Feet m Vertical Foot Mounted
33 m Vertical Flange Mounted m Shaft Down m Shaft Up m Solid Shaft m Hollow Shaft m Non-Reverse Ratchet
34 m Vertical Motor to carry thrust (if selected, complete applicable area of Bearing &/or Driven Equipment / OEM section, pg. 6, lines 39-40)
39 m Data for Non-massive System Dynamic Analysis Required From Machine Vendor per 4.4.6.1.3, a, b, c, d
40 Electrical System: Primary Power Source Volts Phase Hertz Maximum Ground Fault Amps
42 3-Phase Fault Current at Machine Terminals (5.1.2) MVA Let-Through Energy (5.1.2.1): I2 t (Ampere-squared seconds)
43 Min S.C. at Motor Bus (4.2.3.2, c) MVA at V base X/R Ratio: Min.Motor Term. start voltage % rated
44 Other Information:
4 m Antifriction (4.4.7.1.3)
5 m Other:
9 m Other:
10 Seals: m Special Seals for Gas Purge (4.4.7.3.a) m Non-conducting Seals (4.4.7.3, b)
11 Other:
12
16 System Supplied By (4.4.8.4): m Driven Equipment Supplier m End User m Motor Supplier m Other
17 Lube System to comply with API 614 (4.4.8.6): m Part 3 General Purpose m Part 2: Special Purppose m ISO 10438-1
18 Main Oil Pump Driven by: m Supplier Decision m Separate, independent motor m Main motor shaft
19 Other Lube System information:
20 m Meet Cleanliness Requirements of API 614 for 5 GPM & above capacity (6.2.3.2)
23 m Pure Oil Mist (4.4.7.4.1; 4.4.7.4.5) m Oil Mist Ready or m Oil Mist Provisions Only (bearing grease removal may be required - see guide)
24 Vertical Motor Bearings: Thrust Bearing: m Supplier Decision m Grease Lubrication m Oil Sump Lubrication
26 Other:
SPECIAL CONDITIONS
27 m Shaft and Spider one piece forging for 4 or more poles (4.4.5.1.4; 4.4.5.1.2, b)
29 m Efficiency Evaluation Factor (8.1.2), EF = cost / kW C= cost / KWH applied at % of full load
32 m External Loads Imposed on Motor Enclosure when Connected at Installation Site, Define (4.4.4):
33
35 Other:
37
38
m m Supplier Decision
REVISION NO. DATE BY
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE 5 OF 12 Rev
Sheath Material:
Sheath
m
Material:
Supplier Decision Other:
5
m
m
Bearing Heaters (4.4.8.3):
Operating Voltage
Operating Voltage
Main Terminal Box Space Heaters required: also see Main Terminal Box section, page 4
Phase
or
m Dual Voltage Design
6 For Classified Areas provide Temp. Code (from pg.1): T3 used for labeled heaters if not specified
Temp. Code and/or Max. Surface
/
o
7 Temp. (5.4.2): Max. Surface Temp.: C (less than or equal to 80% of AIT on pg.1 for unlabeled heaters, 160 o C if AIT not specified)
9 Required Number per Phase (5.2.1.2): Three (3) m Other Wires: Resistance:
m m Other
Operating Voltage
11 Thermocouples: Type: No. per phase: Three (3)
12 Bearing Temperature Detectors (5.3): One (1) Per Bearing Hydrodynamic, Thrust Bearings m Other Qty / Bearing m Dual Element OK
13 m RTD - Platinum, 3 Wire, 100 Ohms at 0°C (5.3.1) m Provisions Only m Install per API 670 (5.3.1) m Ground One (1) Common Lead
m Main Terminal Box Space Heaters required: also see Main Terminal Box section, page 4
14 m Other RTD Material: Wires: Resistance: m Other info:
15 m Thermocouples: Type:
16 m Oil Temp. Indicators (Dial Thermometers) (4.4.7.1.16) Type: m Alarm Contacts Number of Contacts: m NO m NC
17 Location of Terminations for Bearing Temp. Det. (5.1.14): m Supplier Decision m Terminal Head m T-box m T-box with Winding Temp. Det.
18 Antifriction bearings: m Use selections above when Antifriction bearings are specified
20 Non-contact Shaft Probes (5.8.1): Motors operating at 1200 rpm and higher Motors operating at less than 1200 rpm
23
Phase Reference-Probe (5.8.1):
Motors operating at
Number per bearing (X-Y) (5.8.2):
required
Two (2)
m
m
Installed
Four (4)
m Provisions
Two (2)
m
m
Motors operating at
Installed
Four (4)
24 m Provide two (2) axial-position probes for hydrodynamic thrust bearings at the thrust end (5.8.2): m Provisions m Installed
26
Supplier
Supplier Decision
Other:
Purchaser Defined, Type:
m Supplier m
Installed By:
less than 1200 rpm
Other:
29 Location of Terminations (5.1.14): m Supplier Decision m In Osc.-Demodulators Box m In Sensor Housing m Other:
31 Sensor: m m Installed Provisions Only m Per API 670 (5.8.3) m Supplier Decision m Purchaser Defined:
33
Vibration Switch:
required
Device Provided By: m m
Installed Provisions Only
Supplier Other:
Per API 670 (5.8.3) Supplier Decision
Installed By: m
Purchaser Defined:
Supplier m Other:
34 Define Mounting / Hole Size if Purchaser Defines Device: If Switch, Type: m Manual Reset m Electric Reset
41 Alarm and Control Switches (5.6.1): SPDT 10 Amp 120VAC & 125VDC m Other:
42 Auxiliary Equipment T-Boxes (5.1.4.1): Location of Aux. Boxes (facing non-drive end): m Left Side m Right Side m Other:
43 m Stainless Steel Aux. Boxes/Encl. (5.1.4.1) Cond./Cable Entry (5.1.4.1, 5.1.13): m Bottom m Left or m Right Side facing non-drive end
44 Accessory Equipment Wiring Outside Enclosure (5.1.11): Rigid Conduit m Other:
m Typical Drawings m
or
10 Refer to page 5 for heater T-Code, etc.
m Dual Voltage Design Operating Voltages / Phase
Proposals & Literature (8.1.8) Purchaser defined Efficiency Method (8.1.3,f):
11 For the devices following below, the Purchaser may make a Provide-Install selection; the default is Provide and Install by Supplier :
m 12
Separate Price For Each Test on Data Sheetm (8.1.14)
13 Type: m Self-balancing
m
Differential Protection Current Transformers (5.1.6, h; 5.1.8; 5.6.3)
Packaged Price For All Tests
m
Provided By and
on Data Installed By
Sheet
Full Differential
(8.1.14)
m
m All Phase Leads In Terminal
Provide requirements for Special Weather15 &mWinterizing
Box
14
mm Provide safe stall time calculation method and limits (4.2.4.3)
Accuracy Class
(4.3.6):
Protection (8.1.15)
Surge Capacitors (5.1.6, g; 5.6.2.1, 5.6.2.3): m Microfarads
Ratio Quantity:
m m m
m Provide Quote
m
16 Surge Arresters (5.1.6, g; 5.6.2.2, 5.6.2.3): kV Rated
Provide Quote for Supervision of Installationmand Erection (8.1.17)17 m for Start-Up Commissioning Service (8.1.17)
Current Transformers (5.1.6, h) for Phase Current Meter
m
m m
m m m
m Partial Discharge (PD) Detectors (5.6.4.1, 5.1.6, l)
24 Qty. Special Tools and Lifting Devices (4.1.11, 4.1.12, 4.4.2.14): Proof of Nonsparking, Corrosion-Resistant Fan (4.4.10.6.1)
Drawings (8.5) System of Units for Drawings
25
/mData (1.3.1): U.S. / N.Am. Customary
Separate Nameplate with Purchaser's Information - list below (4.4.11.4)
onlyTest Data - Define
m Electronic Vibration SI (Metric) only
Digital Format below (6.3.3.17)
U.S. (SI) SI (U.S.)
m
26
Manufacturer To Supply Curve Data in Tabular
27
Format
Packaging (6.4.1) m(8.5.1) Define preferred Digital Format
Domestic m Export Boxing m Special Shipping Bearings (6.4.1, k)
: Storage More Than Six Months (6.4.2)
m Outdoor
and
System inspection
of Units of bearings
for Drawings / Data (1.3.1): m U.S. / N.Am.and seals
Customary only (8.7.4,
m c) m U.S. (SI) m SI (U.S.)
SI (Metric) only
36 m Manufacturer To Supply Curve Data in Tabular Format (8.5.1) Define preferred Digital Format :
m m Quantities ofincluding
Photos showing machine assembly steps37required; each
Documents & Drawings,
38 m
step of Schedule
and Documentation bearing assembly
(or define (8.7.5)
source for this information) (8.5.1):
40
m
Certications
m
(including
Quantity of Instruction Manuals PMI),
to Provide (8.7.1) and
(Typically other
supplied Certifications for the machine(s) (8.7.6)
in digital format):
Detailed instructions and photo's, etc. for disassembly and inspection of bearings and seals (8.7.4, c)
41 m Photos
Define any/all Certifications required, including materials:
showing machine assembly steps required; including each step of bearing assembly (8.7.5)
42 m Copies of Applicable Certifictions, including NRTL, Material Certications (including PMI), and other Certifications for the machine(s) (8.7.6)
44
Sauer May 2017 Page 41
PAGE 6 – LOAD, STARTING, OEM DATA
INDUCTION MOTOR JOB NO. ITEM / TAG NO.
API 541 5th Edition -- DATA SHEETS PURCHASE ORDER NO.
U.S. CUSTOMARY UNITS REQ. / SPEC. NO.
PURCHASER'S SELECTIONS REVISION NO. DATE BY
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE 6 OF 12 Rev
1 Load Torque and Inertia Requirements (4.2.2): Per NEMA MG 1-20 or m Per specified load curve & data (4.2.2.1,a)
3
Design Load Curve Condition: m Unloaded (e.g. closed valve or damper)
6 Motor Starting (4.2.3): Across-The-Line Starting at 80% of Rated Voltage (4.2.3.1) or m Other ATL % of rated voltage %
7 m Other Starting Method (4.2.3.2, a): m Autotransformer m Captive Transormer m Reactor m Solid State Soft Starter m ASD
8 Other Method % volts: % If Soft Starter, define Percent Locked Rotor Current Limit during acceleration: %
m m m
10 m Determine Starting Capability per (4.2.3.2, b): Min. Volts at Motor Terminals under Amps Locked Rotor Current
11 or (4.2.3.2, c): Min. S.C. MVA and X/R ratio with base voltage and % Rated Volts at Motor Terminals
12 m Provide Curves & Data (8.1.3, a, b): at Rated Voltage & Min.Start Conditions m Other: % Volts m Other:
13 m No. of Consecutive Starts Other than Table 3 (4.2.4.1): With motor temperature at ambient: 3 m Other:
m Loaded
14 With motor temperature greater than ambient but less than rated operating temp.: 2 m Other:
m
Starting(e.g. open valveVoltage
or damper)
15 No.of Full Voltage Starts if more than 5000 required (4.2.4.1; 4.4.5.1.1):
m%Partially
m Other ATL
17 Driven Equipment: Tag No.(s): Description Location
18
19
of rated voltage
Loaded (e.g. min.flow)
Driven Equipment Mfgr.:
%
Driven Equip. Rotation Viewed from Non Drive End of Motor :
Type / Model No.
m Clockwise m Counterclockwise m
RPM
Bi-directional
Overspeed Trip Point
20 Required Motor Rotation Viewed from Non Drive End of Motor : m Clockwise m Counterclockwise m Bi-directional
25 Load Characteristics Per (4.2.2.1): NEMA MG 1-20 m Other - Provide Load Speed-Torque Curve No. (4.2.2.1, a):
26 Total Driven-Equipment/Load Inertia Reflected to Motor (4.2.2.1, c): Wk2: lb-ft2 or GD2: kg-m2 at: RPM ASD
27 m Speed Increasing or Reducing Gearbox (4.2.2.1, c): Ratio: Note: Affect on intertia to be included in Total Inertia above
28 Driver Connection to Load: m Direct Coupled m Gearbox m V or Cog Belt Belt Ratio:
m m m
If Soft Starter, define Percent
29
30 m Locked Rotor
Coupling: Specified By: m Current Limit during acceleration:
Motor Shaft Extension (4.4.5.1.9):
m
Cylindrical Fit
Purchaser
Taper Fit
33 Motor Half-Coupling Mounted By (4.4.9.4): (requires vibration test in 6.3.1.5 when Motor Supplier mounts half-coupling)
35 Coupling Inertia (4.2.2.1, c): Wk2: lb-ft2 or GD2: kg-m2 (To be included in Total Inertia above)
36 Mass Moment of Coupling Half (4.4.6.2.1.1,f ): lb-ft2 or kg-m2 (For damped unbal. response analysis)
41 Other Information:
42
2
m
l
( m ) Indicates line item is not required
v (v)
t (t)
Indicates line item applies to only one machine in a multiple machine application/order
3 Make selections in only one column for each item Required Witnessed Observed
m
4 (6.1.3.3; 6.3.1) (6.1.3; 6.1.3.1; 6.3.1.1) (6.1.3; 6.1.3.2; 6.3.1.1)
7
Coordination Meeting (8.2)
l
8 Torsional Analysis Data (4.4.6.2.2) Analysis By:
9 Submit Test Procedures and Acceptance Criteria 6 Weeks Before Tests (6.3.1.4) m
(l) 10
11
12
Stator Core Test (6.3.4.1) Indicates Purchaser required line item
Demonstrate Accuracy of Test Equipment (6.3.1.15)
v
17 Partial Discharge Test for Machines 6kV and Greater (6.3.4.6) m v m v m v
(v) 18
19
machine in a multiple machine
Rotor Residual Unbalance Verification Test (4.4.6.3.4)
21
22
application/order
Vibration Test with Half -Coupling (6.3.1.5) (req'd if Supplier mounts cplg. 2.4.9.4)
24
Routine Test - Always required for all machines (6.3.2)
(Purchaser to select one of below options)
Bearing Dimensional & Alignment Checks Before Tests (6.3.2.1, k)
l
m
t
v
m
m v
m
m v
m
26 Purchaser Supplied Vibration Monitoring / Recording (6.3.3.7) m v m v m v
tto supply
m m m
Purchaser ( t ) Half-Coupling
27
machines in a multiple machine Efficiency (6.3.5.1.1, a) Locked Rotor current, PF and torque (6.3.5.1.1, b)
v v
Full Load Current and Slip (6.3.5.1.1, c)
v
29 Breakdown Torque (6.3.5.1.1, d) Heat Run (6.3.5.1.1, e) Speed Torque Curve (6.3.5.1.1, f) Noise Test at No-Load (6.3.5.1.1, g)
m
30 DC High-Potential Test (6.3.5.1.2) m v m v m v
application/order
Purchaser to provide data
31
44 Notes:
3 Full Load Speed RPM Insulation Class F Temperature Rise Class B Service Factor 1.0
4 Enclosure Full-Load Torque (FLT) ft-lb Rotor Inertia (8.1.3, c) lb-ft2 m Wk2 m GR2 m GD2
5 Locked-Rotor Torque (LRT) % FLT Pull-Up Torque (PUT) % FLT Breakdown Torque (BDT) % FLT
6 Calculated Expected Data (8.1.3, f) at the following Loads: m For Recip. Comp., Calc. Eff. is based on Pulsating Current Conditions from Pg.6
8
Load Point
Efficiency m m
DATA
50%
%
75%
%
100%
%
Other: %
%
Area Classification (4.1.8):
m m
o
10 Current Amps Amps Amps Amps Autoignition Temp C or Temp.Code
12
Guaranteed Efficiencies (8.1.3, f) at % Load = %
Max. Sound Pressure Level (4.1.3): 85 dBA @ 1 m. NO-LOAD, FULL VOLTAGE/FREQUENCY, SINE WAVE POWER
Yes
Test Method (8.1.3, f):
m Other:
No
dBA
13 Motor Power Source: Sine Wave Power m ASD Power only m ASD only w-Bypass to Utility Power
14 m ASD + DOL Start capability m ASD w-DOL Start and Bypass to Utility Power
16
is specified, vendor defined maximum allowable pressure (4.4.
Variable Torque Speed Range: Min Speed
RPM
ft-lb Max. Speed
Max. Speed
RPM
RPM
ft-lb
ft-lb
20
Base Frequency(ies) and Harmonics assumed present in the supply waveform(s) (8.1.3,f):
24 TEWAC Heat Exchanger requirements (4.4.1.2.4): Tube materials (4.4.10.8, b): 90-10 Cu-Ni m Other Tube material:
27 Bearings (4.4.7.1): Hydrodynamic (4.4.7.1.1) m Sleeve (4.4.7.1.1) m Tilting Pad (4.4.7.1.1) m Antifriction (Horizontal) (4.4.7.1.3)
lbs.
28 m Antifriction Thrust Bearing (Vertical) (4.4.7.1.5) m Hydrodynamic Thrust Bearing (Vertical) (4.4.7.1.10)
31 Lubrication (4.4.8):
(4.4.7.1.11, a)
m Yes m No
lbs
32 m Pressurized Lube System (4.4.8.4) m Common With Driven Equipment (4.4.8.5) System Supplied By (4.4.8.4): m Others m Motor Supplier
Machine Proposed is in Strict Compliance with API 541 5th Edition? (8.1.9)
34
35
Oil Requirements per Bearing (8.1.4): Flow: GPM
kW
Volume: QTS
36 mPurge Oil Mist, Hydrodynamic Brg's mPure Oil Mist, Antifriction Brg's mOil Mist Ready, Antifriction Brg's.
Oil Mist Provisions (4.4.7.4) (see Guide):
m m m
37 Other: m Grease, Type:
Yes No 38
39
List of Applicable Exceptions Attached
Magnetic Stator Slot Wedges Used (4.3.10): m Yes m No
When Enclosure Pre-Start Purging is specified, vendor defined maximum allowable pressure (4.4.1.1, e):
44 Machine Proposed is in Strict Compliance with API 541 5th Edition? (8.1.9) m Yes m No m List of Applicable Exceptions Attached
1 USER
U.S. CUSTOMARY UNITS
APPLICATION
REQ. / SPEC. NO.
Page 2/4 Motor Supplier Order Data REVISION NO. DATE BY
2 LOCATION SUPPLIER 10 12
N.A. Bold Italics = Indicate Default Selection REV. DATE PAGE OF Rev
INDUCTION MOTOR JOB NO. ITEM / TAG NO.
3 PROJECT NAME SUPPLIER REF. No.
m AS-DESIGNED -- mDATA
API 541 5th Edition SHEETS
AS-BUILT PURCHASE ORDER NO.
4 SITE / PLANT NUMBER of UNITS REQUIRED
U.S. CUSTOMARY UNITS REQ. / SPEC. NO.
BEARINGS, HOUSINGS AND SEALS
5 MOTOR TAG No.(s)Page 3/4 Motor Supplier Order Data REVISION NO. DATE BY
1
Bearings: Type: m Hydrodynamic
N.A. (4.4.7.1.1) m
Bold Italics = Indicate DefaultAntifriction Selection(4.4.7.1.3) REV. AFBMA
DATENumber(s): PAGE 11 OF 12 Rev
MOTOR RATING - ELECTRICAL AND PERFORMANCE DATA INDUCTION MOTOR JOB NO. ITEM / TAG NO.
2 m Split Sleeve (4.4.7.1.1)
m
Drive End:
m
6 Quantity Type / Model No.
3
Frame Size / Designation
m Tilting Pad (4.4.7.1.1)
Motor Power: m API
m
AS-DESIGNED
Utility-Grid 541
OppositeU.S.
5th Edition
ASD
Drive CUSTOMARY
End:
-- DATA SHEETS
AS-BUILT PURCHASE ORDER NO.
UNITS REQ. / SPEC. NO.
7 Nameplate Power / RPM Rating (4.2.1.1):
4
m HP m kW
Hydrodynamic Bearings: Oil Rings Included (4.4.8.1)
RPM Full Load
m Yes m No
RPM Synchronous ACCESSORIES Poles & SETTINGS
Page 4/4 Motor Supplier Order Data REVISION NO. DATE BY
8 Nameplate Voltage/Ph/Hz Rating (4.2.1.2): Volts (4.2.1.2) 1 Heaters: Phase N.A. Hertz
Single Voltage Design: Dual Voltage Design:
5 Bearing, Drive End: Capable of Self-Lube
2
m Yes m No Manufacturer
Operating Voltage
Bold Italics Model
kW
= Indicate
Phase
/ PartDefault
No.
Operating
Selection
Voltages
REV. DATE
kW Phase Sheath Material
PAGE 12 OF 12 Rev
9 Insulation Class (4.3.1.1,a): Class F
6 Bore Diameter: Min
Temperature Rise (4.3.1.1, b): Class B
in. Max in.
Enclosure (4.4.1.2):
Bore Length in. m AS-DESIGNED
Type m AS-BUILT
10 Full-Load Torque (FLT)
7
ft-lb Percent FLT at: Locked-Rotor
Design Clearance with Shaft:
3 m
Min
Frame Heaters (5.4.1;
(LRT) 5.4.2;
Pull-Up
in. Max
(PUT) 5.4.3):
in.
Breakdown (BDT)
Bearing Loading:
/ STATOR WINDING AND PSIROTOR REPAIR DATA
11 Expected Data (8.1.3,f) at the following Loads (100% Voltage): 4 m Main T/Box Heaters: /
12 Load Point: Locked-Rotor
8 Bearing, Non-Drive End: Capable of Self-Lube
50% 75% 5 m
100%
m Yes
Bearing Heaters m No
Other: (4.4.8.3): %
1Manufacturer
Stator Coil Information (8.6.2.d, reference
Data is:
Appendix
Model / Part No.
/
G): Coil Dimensional Drawing No.:
15 Current: Amps
11 m Special Seals for Gas Purge (4.4.7.3, a)
Amps Amps8 m OtherAmps m
RTD Material: Amps m
Non-conducting Seals (4.4.7.3, b) m
Wires:Tested this
Other Seal Type
Resistance:
Order m
No.per Phase (5.2.1.2): Three (3) Other
5 Ground-Wall Insulation Description:
16 Guaranteed Efficiency (8.1.3,f) 12 Thrust Bearing: at
% Efficiency m Antifriction
% Load m
9 (4.4.7.1.5)
One Commonm Hydrodynamic
LeadDetermination
Efficiency Each Element (4.4.7.1.10)
6
Grounded
Test Method in(8.1.3,f):
Box. (5.2.1.2)
Thickness Turn Insulation:
Bearing Loading: PSI
mils Thickness Strand Insulation: mils Thickness Groundwall Insulation: mils
17 For Reciprocating Loads (8.1.3,f)13 % Efficiency at
Thrust Bearing
10 with Thermocouples:
% Load
Load Capability
m Momentary
% Current
Downthrust
Type:
Pulsation
7
Max. Current Variation
Coil Configuration:
lbs(8.1.3,g):
Rows by
Upthrust
Momentary
A
Columns
No.per Phase lbs m
(5.2.1.2): Three (3) Other
19 15
Curve No.'s (8.1.3,a,b): Speed-Torque m Non-Drive
Speed-Current m
12 End RecommendedDrive End Manufacturer
Settings: Alarm:Speed-Power Factor
9 Total Number of Stator Slots:
Model / Part No. Shutdown:
Winding Throw: Winding Connection:
20 When specified: Calculated Rotor-Response Curve No. (8.6.2,b): 13 Bearing Temperature Detectors Acceleration
LUBRICATION
10(5.3): Slot
One Curve
SYSTEM
(1) Per
Filler
No.Bearing - Hydrodynamic,
Description Thickness: Top Thrust Bearings m
mils Side Other Qtymils/ BearingMiddle m Dual Element
mils Slot Dimensions:
21 Acceleration Time (8.1.3,d): At16 m
Rated Voltage:
Hydrodynamicsec. Bearing AtRing
Minimum
m
14 TypeStarting
Self
RTD - Voltage/MVA:
Lubrication
Platinum,(4.4.8.1)
3 Wire, 100 sec.
11Ohms m at
Slot Wedge (5.3.1)m
At 0°CConstant-Level
% VoltageOilers
Material: m
Sec
(4.4.7.2.2)
Provisions Only m
Install per API 670 (5.3.1) Ground One CommonMagneticLead Slot Wedges: m No m Yes
22 Thermal Capacity / Limit Curve No. m
17 (4.2.4.2)Pressurized Lube (4.4.8.1, 4.4.8.4)
15 mOilOther Rotor
RingsRTDProvided:
Material:m
Inertia - Wk 2
Yes m
(8.1.3,c)
12
No Bearings
Wires: designed
Stator Bore Diameter:
lb-ft 2
to operate without lube system:
Resistance: m m
m Yes No
Other info:
Stress Grading Description if Applicable:
23 Locked-Rotor Withstand Time, Cold m
18 (4.2.4.2,a; at 100%
8.1.3,e) with
Common DrivenVoltage
Equipt. m
16 (4.4.8.4) SecSystem
at 80%
Thermocouples: Voltage
Supplied By (4.4.8.4):
Type: 13 m
Sec at
Driven Equipt.% Voltage
Special End-Turn Bracing: m
Supplier m
Sec
End User m
Motor Supplier Other
24 Locked-Rotor Withstand Time, Hot m
19 (4.2.4.2,b;Motor Onlyat
8.1.3,e) 100%
Lube Voltage
System 17 m Sec Type
Required
Dial at 80% Voltage Type/Viscosity
/ Recommended
Thermometers Sec
(4.4.7.1.16):
14
ofatOil (4.4.8.5;
Other: Type
% Voltage
4.4.8.8): m
Sec Alarm Contacts Number of Contacts m m
NO NC
25 Starting Capability (4.2.4.1): Consecutive
20 Successful
Total Bearing OilStarts With :18
Requirements (8.1.4): Locked-Rotor
Antifriction bearings: m
GPM Current
15
Above 100 % PSI
atselections
Rotor Information:
Voltage
applied Heat Loss To
to AntifrictionAmps
Be Removed per Bearing
bearings
Total Conductor Weight: lbs.
kW
Number of Bars: Strand or Bar Size:
26 21 m Motor prepared
Motor initially atfor
ambient temperature
Supplemental
19 Purge 3 Oil Mist (4.4.7.4.1)
Recommended Locked-Rotor
OtherCurrent
Settings: at
Lube System
Alarm:
16
80 % Voltage
information:
Conductor Material:
Amps Shutdown:
Ring Material: Retaining Ring Alloy, If Applicable:
27
22 m Antifriction Bearings: m
Motor temperature above ambient but not exceeding rated operating temperature 2
Grease
20 EnclosureType:
Locked-Rotor Current at
Accessories 17
% Voltage
Shaft Material:
Amps
Ring Dimensions Premachining:
28
23 m
Wait time after all Consecutive Starts have been used (4.2.4.2, d, e): With Motor Running
Pure Oil Mist (4.4.7.4.5)21 m
WP-II,Oil Mist DPG/ODP
WP-I, mSec
Ready or (4.4.1.2.2)
With Motor Stopped
Oil Mist Provisions m
Only
Air Filters:
Sec
Provided (5.5.4): Required for WP-II (5.5.3) m Air Filters Not Provided (5.5.4)
29 Max. Sound Pressure Level (4.1.3)
24
85 dBA @ 1 m., no-load m
22
Other:
Filter Capability (5.5.4): 90% Grease18 removal
m
Notes: required before operation with oil mist?
of particles > 10 micron Other m m Yes Nom Air Filter Provisions Only (5.5.2)
19
30 Induction Motor Equivalent Circuit Data:
25 m Phase-to-Phase
Vertical Motor Bearings: 23 Resistance
Filter Manufacturer:
Thrust Bearing:
Ohms, @
Guide Bearing:
°F
Mfgr. Recommended Type: Lubricant: Model:
20
31 kVA Base at Rated Voltage and 77°F
26 m
Subtransient Reactance X"d
24Oil Sump Lubrication m Total Winding
Oil Sump
Differential Pressure Device (5.5.5):
Capacitance to Ground
Lubrication Type/Viscosity
Provisions Required for WP-II of m
Oil:
uF
Provisions Only Provided m Device Not Provided
21
32 Locked Rotor at Rated Voltage:
27
Stator R
m 25 m
Rotor R
Grease Lubrication m
Differential PressureGreaseSwitch Lubrication
Magn R
Provided (5.5.5): m
Grease Type: Differential Pressure Gauge Provided (5.5.5) m Combination Switch / Gauge Provided
33 Stator X Rotor X 22 Magn X
26 Device Manufacturer:VIBRATION DETECTORS Type: Model:
34 Rated Load at Rated Voltage: Stator R Rotor R 23 Magn R
28 m Non-contact Shaft Probes 27 (5.8.1): Recommended
Number per bearing:settingsTWOfor Differential
24
m
(2) (5.8.1) Pressure Switch: Alarm:
Four (4) (5.8.2) Shut-Down:
35 Stator X Rotor X Magn X
29 Shaft Probes:28 m Provisions
TEAAC m Installed
Enclosure (4.4.1.2.3) Manufacturer:
Heat
25
Exchanger Tube Materials (4.4.10.8, Model:
a):
36 Residual Voltage Open-Circuit Time Constant: Motor Only sec. With Surge Capacitors sec.
30 Phase Reference Probe (5.8.1):
29 m Provisions m Installed
TEWAC Enclosure (4.4.1.2.4) 26
Manufacturer:
Heat Exchanger Tube Materials (4.4.10.8, b):
Model:
90-10 Cu-Nim Other
MOUNTING, WEIGHTS
31 Oscillator-Demodulators:
30 m Provisions m Installed
Tube Construction (4.4.1.2.4, d;
Manufacturer:
274.4.10.8, b,c): Single Tube m Model:
Double Tube
37 Mounting: m Horizontal Foot Mounted m Horizontal Flange Mounted with Feet m Vertical Foot Mounted
32 m Bearing Housing Seismic Sensors 31 (5.8.3): m Leak Per API 670
Detection 28(5.8.3) c): Required
(4.4.1.2.4, Double Tube Leak Detection: Inner Tubes Onlym Outer also
38 m Vertical Flange Mounted m Shaft Down m Shaft Up m mSolid Shaft Hollow Shaft m Non-Reverse Ratchet
33 Sensor: m Provisions
32 m Installed
Cooler Type:
Location/Orientation (4.4.1.2.4,
29 c): Manufacturer: Model: m Redundant Coolers (4.4.1.2.4, b)
39 Flange Type: Flange Bolt Circle Diameter:
34 Vibration Switch: m Provisions
33 mWaterInstalled Type: Max
Flow (GPM): Min Manufacturer: Water Pressure Model:
(PSI): Max Min
40 m Soleplate furnished with motor m Baseplate furnished with motor m 30
Adapter Plate furnished with motor
35 D.E. Bearing Qty.: 34 m m
Position(s):
Flow Sensor Horizontal m
Local Indicator m
31 Vertical
Provided (4.4.1.2.4, mm
Axial g) Other:
Provisions Only Manufacturer: Type: Model:
41 Weights: Motor Net: lbs. Stator lbs. Rotor lbs. Shipping lbs.
36 N.D.E. Bearing Qty.: 35 m m
Position(s): RelayHorizontal m
Contacts Provided: m m
32 Vertical Normally mm
Axial
Open Other:
Normally Closed
37
36
Recommended Vibration Settings: Alarm
High Flow Alarm Set33
Point
Shutdown
GPM
Inches per Sec. m
Low Flow Shutdown Set Point
Other
GPM
37 m
Cooler Air Inlet & Outlet Temperature
34 Sensor (4.4.1.2.4, h): Required
38 Alarm Shutdown Mils. mManufacturer:
Other
Type: Model:
38 Sensor Type: 35
39 Frequency of Shaft Resonance
m
39Closest to Operating Speed:
Cooling Water Conditions36
per 4.4.1.2.4, a Hertz
m
Water/Glycol Solution m Other Cooling Water Conditions (Purchaser Specified)
39
40
41
42
Face-to-face meetings
Coordination meeting
Verify scope of supply & expectations
Design review meeting
Finalize and confirm design
Discuss & resolve issues before they affect the outcome
Bart Sauer graduated from Case Western Reserve University (Cleveland, Ohio, USA) in 1989 with a Bachelor of
Science degree in Mechanical Engineering. He has been an employee of Siemens Industry, Inc. at the ANEMA motor
plant in Norwood, OH, since 1990, serving in roles as a Mechanical Product Engineer, Sales Application Engineer, and
his current role as a Market Segment Manager for the oil and gas industry since 2009. In this role he serves as the
technical lead for the API 547/541 specifications for Siemens AboveNEMA motors.
Bart has been an author on three previous IEEE papers, and is a current committee member of the 2018 Cincinnati
IEEE-IAS PCIC conference.
Bart has 3 daughters and has been happily married for 27 years. He is an avid fisherman, a high school Sunday
school teacher and a Canadian Olympic hockey team fan.