5'', 19.50#, 0.362'', G105, IEU, R2: NC50 (4-1/2"IF) - 6.625'' X 3.250''

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Drill Pipe Specification & Performance Data Sheet

5'', 19.50#, 0.362'', G105, IEU, R2


NC50 (4-1/2"IF) - 6.625'' x 3.250''
QT Item #: 9807

Tube / Pipe Body Specification Tubular Assembly Tube / Pipe Body Performance
OD: 5.000 in Adjusted Weight: 24.11 lbs/ft Inspection Class: Premium Class 80%

ID: 4.276 in Length (approximate): 30 - 32 ft Remaining Body Wall: 0.290 in

Wall Thickness: 0.362 in Box TJ Length (nominal): 14 in Tensile Strength: 436,150 lbs

Weight (nominal): 19.50 lbs/ft Pin TJ Length (nominal): 11 in Torsional Strength: 45,200 ft-lbs

Grade: G105 Fluid Displacement: 0.0088 bbls/ft Burst Capacity: 12,160 psi

Range: R2 Fluid Capacity w/ IPC: 0.0169 bbls/ft Collapse Capacity: 8,760 psi

Upset Type: IEU An oilfield barrel equals 42 US gallons.

Maximum Upset OD: 5.125 in

Notes: Notes:
-Dimensions, wall thickness, and tool joint lengths shown above are nominal if not otherwise stated. -Tube / Pipe body properties are calculated based on
-Values shown may vary with actual values due to OEM tolerances, rounding, and other factors. uniform OD and wall thickness.
-Capacity, Displacement, & Adjusted Weight are best estimates from the OEM and are based on pipe purchased at
95% RBW with longer than standard tool joints. Nominal thickness of IPC is .009" when applied.

Connection / Tool Joint Specification Connection Performance


Connection: NC50 (4-1/2"IF) Thread Compound Friction Factor (FF): 1.0 FF 1.15 FF

OD: 6.625 in Maximum Make-Up Torque: (Recommended) 30,700 35,305 ft-lbs

ID: 3.250 in Tension at Maximum Make-Up Torque: 1,118,500 1,118,500 lbs

SMYS: 120 ksi Minimum Make-Up Torque: 25,600 29,440 ft-lbs

Drift Size: 3.125 in Tension at Minimum Make-Up Torque: 1,130,300 1,130,300 lbs

Elevator Taper: 18° Torsional Strength: 51,200 58,880 ft-lbs

Notes: The Maximum Make-Up Torque based on the appropriate thread compound friction factor (FF) is
-Above dimensions are nominal. recommended. MUTs lower than maximum should only be applied when MUT is limited by rig equipment or
-There is no published pressure rating for this connection tensile capacity. MUT values lower than Minimum MUT should never be used.
connection.
Adjust MUT values per the applied thread compound’s FF greater than 1.0, without exceeding 1.15. Above values
tabulated at 1.0 and 1.15 FF.

Elevator Shoulder Capacity


-Refer to the attached OEM page(s) for capacities with
wear prior to using.

For combined loading of drill pipe, connection wear table, & elevator capacity figures, please see the attached page(s) provided by NOV-Grant Prideco™.

www.quailtools.com
Visit our website or download the Quail Tools Tubular & BOP Specification App for the latest updates and specifications!
The technical information contained herein, including the product Specification / Performance sheets and other attached documents, have been generated from material provided by the manufacturer where available. It is for reference only and should not be construed as a
recommendation. The user is fully responsible for the accuracy and suitability of use of all technical information. Quail Tools cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Assembly
properties are based on uniform OD and wall thickness. No safety factor is applied. The information provided for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the
customer and/or end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. The user should consider all field conditions along with combined
factors which may affect the final string design used in the field. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
New Iberia, LA (337) 365-8154 Victoria, TX (361) 579-0244 Odessa, TX (432) 366-1491 Evanston, WY (307) 789-5860
Texarkana, TX (903) 838-1624 Williston, ND (701) 774-2280 Morgantown, WV (304) 212-5191
Houston, TX (281) 445-1777 * Denver, CO (303) 534-1873 * Ok. City/Tulsa, OK (918) 994-4695 * Dallas, TX (972) 661-1443 * San Antonio, TX (210) 822-4801 * Pittsburgh, PA (724) 916-4643

**Uncontrolled When Printed**


devind QT-DP 5.000 19.50 G NC50 6.625 x 3.250 R2 80RBW Generated on: 4/28/2021
QT Item #: 9807

Drill Pipe Performance Sheet (1.0 FF)


1/8/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: NC50 6.625" x 3.25" (120 KSI SMYS ) Friction Factor: 1.0 Connection: NC50 6.625" x 3.25" (120 KSI SMYS ) Friction Factor: 1.0
Pipe: 5.0" OD 0.362" Wall Thickness G105 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (30700 ft-lbs ) At Min MUT (25600 ft-lbs ) 6.625 30700 25600
Operational Assembly Max Operational Assembly Max 6.557 30700 25600
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 6.489 30700 25600
0 436100 0 436100 6.42 30700 25600
1600 435900 1300 436000 6.352 29800 24800
3200 435100 2700 435400 6.284 27700 23100
4800 433700 4000 434400 6.216 25700 21400
6400 431800 5300 433100 6.148 23700 19700
8000 429300 6600 431500 6.08 21700 18100
9600 426200 8000 429300 6.011 19700 16400
11200 422500 9300 426800 5.943 17800 14900
12800 418300 10600 424000 5.875 16000 13300
14400 413400 11900 420800
16000 407900 13300 416800 Elevator Capacity
17600 401700 14600 412800 Elevator Bore Diameter: 5.25" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
19200 394800 15900 408300 Connection: NC50 5.0" 0.362" wall IEU G105
20800 387200 17200 403300 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
22400 378800 18600 397500 No Wear 1/32" Wear Factor
24000 369600 19900 391600 6.625 1411900 1383500
25600 359500 21200 385200 6.557 1334400 1306000
27100 349100 22500 378300 6.489 1257700 1229200
28700 336900 23900 370200 6.42 1180700 1152200
30300 323600 25200 362100 6.352 1105600 1077100
6.284 1031300 1002800
6.216 957800 929300
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
6.148 885100 856600
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 6.08 813200 784700
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 6.011 741000 712600
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
5.943 670700 642300
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
5.875 601300 572800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco
QT Item #: 9807

Drill Pipe Performance Sheet (1.15 FF)


1/8/2021

Combined Loading for Drill Pipe Connection Wear Table


Connection: NC50 6.625" x 3.25" (120 KSI SMYS ) Friction Factor: 1.15 Connection: NC50 6.625" x 3.25" (120 KSI SMYS ) Friction Factor: 1.15
Pipe: 5.0" OD 0.362" Wall Thickness G105 80% Inspection Class Tool Joint OD (in) Max MUT(ft-lbs) Min MUT(ft-lbs)
At Max MUT (35300 ft-lbs ) At Min MUT (29400 ft-lbs ) 6.625 35300 29400
Operational Assembly Max Operational Assembly Max 6.557 35300 29400
Torque(ft-lbs) Tension(lbs) Torque(ft-lbs) Tension(lbs) 6.489 35300 29400
0 436100 0 436100 6.42 35300 29400
1800 435800 1500 435900 6.352 34200 28500
3700 434700 3100 435100 6.284 31800 26500
5500 432900 4600 433900 6.216 29500 24600
7400 430300 6100 432200 6.148 27200 22700
9200 427000 7600 429900 6.08 24900 20800
11000 423000 9200 427000 6.011 22700 18900
12900 418000 10700 423800 5.943 20500 17100
14700 412400 12200 420000 5.875 18300 15300
16600 405700 13700 415600
18400 398400 15300 410400 Elevator Capacity
20200 390200 16800 404900 Elevator Bore Diameter: 5.25" Elevator SMYS: 110,100 psi Box Taper Angle: 18 deg
22100 380500 18300 398800 Connection: NC50 5.0" 0.362" wall IEU G105
23900 370200 19800 392100 Tool Joint OD (in.) Elevator Hoist Capacity (lbs)
25800 358100 21400 384200 No Wear 1/32" Wear Factor
27600 345400 22900 376000 6.625 1411900 1383500
29400 331300 24400 367100 6.557 1334400 1306000
31300 314700 25900 357400 6.489 1257700 1229200
33100 297000 27500 346100 6.42 1180700 1152200
35000 276000 29000 334500 6.352 1105600 1077100
6.284 1031300 1002800
6.216 957800 929300
The Technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be

consider as a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume
6.148 885100 856600
responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated 6.08 813200 784700
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions 6.011 741000 712600
(remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user
5.943 670700 642300
to determine the appropriate performance ratings, acceptable use of the product, maintain safe operating practices, and to apply a prudent safety factor suitable

for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter DS, Section DS-16 of the drilling manual,
5.875 601300 572800
it is recommended that drilling torque should not exceed 80% of MUT.

All references to any internal standards or specifications are per the current edition/revision at the point of manufacturing, unless otherwise stated. All references to any external standards or specifications are
per the current edition/revision at the original purchase order (P.O.) date, unless otherwise stated.

Grant Prideco L.P. | 10100 Houston Oaks Dr. | Houston, TX 77064 | www.nov.com/grantprideco

You might also like