I. Objective:
1. To be able to know how to start and shut down the boiler.
2. To determine the different boiler pre-starting inspections.
3. To test the fuel consumption of the boiler.
B. Boiler Controls
1. Burner and its Components
a) Burner Controller
b) Ignition Transformer
c) Ignition Rod
d) Flame Eye
e) Fuel Pump
f) Burner Motor
2. Vessel Control
a) Pressure Controllers
b) FWP cut-in/cut-off controller (Mc donnel & miller)
c) Warrick Relay Control
d) Feed Water Pump
E. Trouble Shooting
1. Burner does not start
Solution: - Check limit controller
- Reset pressure controller
- Check water level controller
- Check warrick contact
- Push burner reset button.
2. Burner runs but not firing
Solution: - Check fuel supply, bleed the fuel pump
- Check ignition rod spacing. Adjust if necessary
- Check ignition transformer
- Wipe flame eye with dry cloth
- Check burner controller
3. Burner runs but not stable
Solution: - Check and adjust air:fuel ratio of burner
4. High stack temperature
Solution: - Check and adjust air:fuel ratio of burner
- Reduce boiler pressure
- Reduce air opening of blower
NOTE: In adjusting air:fuel ratio, Adjust the fuel inlet and air opening one at a
time.
5. Feed water pump is not pumping
Solution: - Check overload relay of FWP. Reset.
- Bleed the pump if pressure is unstable to release unnecessary
air inside the pump.
X. References:
Book title, Author, Publisher, Edition, page/pages.
Internet websites.