Sandvik Mining and Construction Australia Pacific

NDT-Magnetic Particle Inspection Report


Pre Inspection

Site SANDVIK LIP Format No SMC/MPI/8183/2022


Customer PT Freeport Indonesia Date 28/04/2022
Description Bracket Transmission PTFI P.O. No. N/A
Bracket Transm SN N/A SandvikJob No. 7019053/503/6
Unit Type Boom Truck Install to Unit Type Boom Truck
Unit Serial Number - Serial Number SN 021-068
Ex Unit Number - Rebuild to Unit No. 730395
Welding Process MMAW Type of Joint Butt and Fillet Weld
Inspection Spec ASME Sec V Surface Condition Circum / Flat / Radius
After : Sanblasting, Welding,
Acceptance Criteria AWS D.1.1 Stage Exammination Machining, Others

Flaw Detector AC YOKE Bracket Transmission

Technique Contact / Scanning

Manufacture Magnaflux

Contrast Medium WCP - 2

Particle MPI Ink – 7 HF

Magnetic Field Direction Longitudinal / Circullar

Calibration Block 10 lb / 4,5 Kg

Temperature Ambient

Type of Particle Wet

Methode Spraying

Scanning Area/ Location

Figure 1. LH Mount Transmission, MPI Test Not Found Figure 2. Detail Hole Mount, MPI Test not Found Crack
Crack area. area.
Sandvik Mining and Construction Australia Pacific
NDT-Magnetic Particle Inspection Report
Pre Inspection

Figure 3. RH Mount Transmission, MPI Test not Found Figure 4. Detail Hole Mount, MPI Test not Found Crack
Crack area. area.

Test Result

No Item/Description Type Location Tested L / D Result Remarks


1 Transmission Mount N/A Figure 1 to 4 Mark Accepted Not Found Defect
Note: Cr:Crack P: Porosity CP:Cluster Porosity S:Slag IP:Incomplete Penetration UC:Under Cut LF: Lack of Fussion WO: Worn
out MD: Mechanical Damage

Recommendation : Continue to Painting and Assembly.

NDT Inspector Approved by Witnessed by

Herdiman.S/NDT Level 2 Ruslan Bahas Umar Sain


Certificate No.AMI-NDT.074.V.16 Superitendent Manager