Sandvik Mining and Construction Australia Pacific

NDT-Magnetic Particle Inspection Report


Pre Inspection

Site SANDVIK LIP Format No SMC/MPI/8181/2022


Customer PT Freeport Indonesia Date 28/04/2022
Description Cover Radiator PTFI P.O. No. N/A
Cover Radiator SN N/A SandvikJob No. 7019053/601/6
Unit Type Boom Truck Install to Unit Type Boom Truck
Unit Serial Number - Unit Serial Number SN 021-068
Ex Unit Number - Rebuild to Unit No. 730395
Welding Process MMAW Type of Joint Fillet and But Weld
Inspection Spec ASME Sec V Surface Condition Circum / Flat / Radius
After : Sandblasting, Welding,
Acceptance Criteria AWS D.1.1 Stage Examination Machining, Others

Flaw Detector AC YOKE Cover Radiator

Technique Contact / Scanning

Manufacture Magnaflux

Contrast Medium WCP - 2

Particle MPI Ink – 7 HF

Magnetic Field Direction Longitudinal / Circullar

Calibration Block 10 lb / 4,5 Kg

Temperature Ambient

Type of Particle WET

Methode Spraying

Scanning Area/ Location

Figure 1. Cover Radiator, Inner side view, Mounting Figure 2. Hole Mount Base plate, need found worn,
need install nut. need repiar.
Sandvik Mining and Construction Australia Pacific
NDT-Magnetic Particle Inspection Report
Pre Inspection

Need Upgrade

Figure 3. Hole Mount Base plate, need found worn, need Figure 4. Cover Radiator LH Side View, Need Upgrade
repiar. New Model.

Figure 7. Detail Crack area Need Repair. Figure 8. Detail Crack area need repair.

Test Result

No Item/Description Type Location Tested L / D Result Remarks


1 Cover Radiator Cr, Wr Figure 1 to 8 Mark Rejected Can Repair
Note: Cr:Crack P: Porosity CP:Cluster Porosity S:Slag IP:Incomplete Penetration UC:Under Cut LF: Lack of Fussion Wr:Worn
Out Bn: Bent MD: Mechanical Damage

Recommendation : Continue to Repair.

NDT Inspector Approved by Withnessed by

Herdiman.S/NDT Level 2 Ruslan Bahas Umar Sain


Certificate No.AMI-NDT.074.V.16 Superitendent Manager