The measurement »b«, which is the width of the O-Ring groove, has to be larger than the defor-
med O-Ring. Depending upon application the groove may be open on one side. However, the
pressure applied to the medium to be sealed must have full access to the O-Ring. The surfaces of
the groove and the opposed surfaces should have more or less rounded processing traces to
permit peak-to-valley-heights of 44 — 25 um.
Groove sizes
Static application
& t b de t b
1 08 13 5 4 65
18 41 19 5,33 43 69
16 42 2a 55 45 7A
178 13 23 57 465 7A
19 14 24 6 4.95 78
2 15 26 65 54 84
24 18 34 699 585 on
25 19 32 7 5,85 1
262 20 34 75 63 97
27 24 35 8 675 104
3 23 39 84 7.15 109
35 27 45 a5 725 110
353 27 45 9 7 17
36 28 ar 95 82 12,3
4 315 52 10 8.65 13
45 36 58
In case of applying back-up rings the width of groove »be is increased by the width of the back-up
ring resp. in case of support on either side by the double width of the back-up ring.