Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Digitally Generated by: Core Laboratories Panama,

S.A.
Reason: Laboratory data
Location: Panama - All activity
Core Laboratories El Salvador SA de CV Date: 2024.01.22 23:55:06 -05:00
Colonia Rasa 1, Lote 3
Porcion 2
Acajutla
El Salvador

Attention of : Mr. M. Olivares

Analysis Report
Report number : 13201/00036200.1/L/24 Submitted date : 2024-01-19
Main Object : ALCOHOL - LAICA PUNTA Sample submitted at : Saybolt Panama
MORALES
Report Date : 2024-01-22 Date received : 2024-01-20
Date of issue : 2024-01-22 Date completed : 2024-01-22
Sample object : Alcohol Anhidro Proceso Sample number : 15809778
Sample type : Submitted
Sample submitted as : Alcohol Anhidro
Marked : Alcohol Anhidro Proceso - CATSA - Zafra 2023/2024 - Fecha: 17/01/2024

NAME METHOD UNIT SPECS RESULT


Min Max
Higher Saturated Alcohols Q EN 15721
Methanol mass % 1.0 0.007
Higher alcohols mass % 2.0 0
Ethanol, inc. higher alcohols mass % 98.7 99.898
Water Content Q EN 15489 mass % 0.300 0.074
Total acidity Q EN 15491 mass % 0.007 <0.003(0.002)
Anions Q EN 15492
Chloride mg/kg 1.5 <0.2
Sulphate mg/kg 3.0 <0.2
Dry residue Q EN 15691 mg/100mL 10 <10
Sulfur Q EN 15486 mg/kg 10.0 1.4
Conductivity at 25°C Q EN 15938 µS/cm 2.5 <2.5
Density at 20 °C Q ASTM D 4052 kg/L 0.78949
Ethanol Strenght Q American Standard
EC/2870/2000B vol % 99.95
Metals by ICP Q EN 15837
Phosphorus mg/kg 0.15 <0.13
Copper mg/kg 0.100 <0.050

All results in this report refer to the sample(s) tested as taken or submitted like specified in this Analysis report. Uncertainties, available on request, apply in the evaluation of the test results.
All tests are conducted according to the latest version of the methods, unless another version is specifically indicated. Where available and for convenience purposes, the tested sample has
been checked for compliance with supplied specifications, without accepting any liability for the supplied information. In case of dispute or concern, we refer to the interpretation of test results
as defined in ASTM D3244, IP 367, ISO 4259 or GOST 33701. This report shall not be partially copied and reproduced without the written permission of the laboratory.

Saybolt expressly disclaims any representation in this report, whether express or implied, as to the origin of the crude or refined product identified herein. Any designation as to origin is
made solely by the party submitting the sample for analysis. Saybolt has not verified the tested parameters against any supplied specification for purposes of establishing origin. Further,
any certification provided is solely as to the physical and chemical properties of the sample identified in this report.

Core Laboratories Panama, S.A., City of Knowledge, Building 228, Panama City, Republic of Panama Print Date: 2024-01-22 18:54
Tel: +507 3170575 Fax.: +507 3170572 Page 1 of 2
Website: www.saybolt.com Email: saybolt.Panama@corelab.com
All our activities are carried out under Saybolt’s terms and conditions, available at www.corelab.com/saybolt/terms-conditions
Core Laboratories El Salvador SA de CV
Colonia Rasa 1, Lote 3
Porcion 2
Acajutla
El Salvador

Attention of : Mr. M. Olivares

Analysis Report
Report number : 13201/00036200.1/L/24 Submitted date : 2024-01-19
Main Object : ALCOHOL - LAICA PUNTA Sample submitted at : Saybolt Panama
MORALES
Report Date : 2024-01-22 Date received : 2024-01-20
Date of issue : 2024-01-22 Date completed : 2024-01-22
Sample object : Alcohol Anhidro Proceso Sample number : 15809778
Sample type : Submitted
Sample submitted as : Alcohol Anhidro
Marked : Alcohol Anhidro Proceso - CATSA - Zafra 2023/2024 - Fecha: 17/01/2024

NAME METHOD UNIT SPECS RESULT


Min Max
Appearance Visual - clear &
colorless

Lab comments:
Q: CNA Accreditation LE-002 is applicable for tests followed with a Q

Signed by: Jesus Abrego - Laboratory Manager Assistant


Issued by: Core Laboratories Panama, S.A.
Place and date of issue: Panama City - 2024-01-22

All results in this report refer to the sample(s) tested as taken or submitted like specified in this Analysis report. Uncertainties, available on request, apply in the evaluation of the test results.
All tests are conducted according to the latest version of the methods, unless another version is specifically indicated. Where available and for convenience purposes, the tested sample has
been checked for compliance with supplied specifications, without accepting any liability for the supplied information. In case of dispute or concern, we refer to the interpretation of test results
as defined in ASTM D3244, IP 367, ISO 4259 or GOST 33701. This report shall not be partially copied and reproduced without the written permission of the laboratory.

Saybolt expressly disclaims any representation in this report, whether express or implied, as to the origin of the crude or refined product identified herein. Any designation as to origin is
made solely by the party submitting the sample for analysis. Saybolt has not verified the tested parameters against any supplied specification for purposes of establishing origin. Further,
any certification provided is solely as to the physical and chemical properties of the sample identified in this report.

Core Laboratories Panama, S.A., City of Knowledge, Building 228, Panama City, Republic of Panama Print Date: 2024-01-22 18:54
Tel: +507 3170575 Fax.: +507 3170572 Page 2 of 2
Website: www.saybolt.com Email: saybolt.Panama@corelab.com
All our activities are carried out under Saybolt’s terms and conditions, available at www.corelab.com/saybolt/terms-conditions

You might also like