SERVICE DECK-01

FE-02
TC-1c
SLO
PE FE-03
UP
TC-1b DN
TC-1b
LINEN STO TOW +1.20 AFFL TOW +1.20 AFFL
DN

FHC
STORAGE
FREEZER
WALK-IN

WALK-IN
CHILLER

CELLAR

DRY

LINE OF CANOPY ABOVE


MEP RISER
SE LOBBY
MS-10d

PE
TC-1b

SLO
PL EE
OPEN DECK-01
SL E SL E SL E
KITCHEN OP OP OP OP OP OP
SPA / WELLNESS CENTER E SL E SL E SL
SE-01 TC-1c TC-1b
PREPARATION PE-01 PE-02

LINE OF ROOF ABOVE


AREA

COLD STATION

ELEV LOBBY-01 SLOPE SLOPE SLOPE


SLOPE TC-1b SLOPE SLOPE
DRY RACKS
MALE TOILET
TOW +1.20 AFFL
STERILIZER

JAN
CLOSET

PWD TOILET

FEMALE TOILET

RESTAURANT

FE-01
FHC

DN

LINE OF ROOF ABOVE

TOW +1.20 AFFL TOW +1.20 AFFL


OPEN DECK-02
TC-1b
TC-1c
SLO
PE
SLO

PE

H-12

REV. NO. REVISION DESCRIPTION DATE

ISSUE:

FOR CONSTRUCTION
DRAWING
FEBRUARY 16, 2024
RA 9266 SECTION 33
ELECTRONICS & COMMUNICATION CONSULTANT: DRAWINGS AND SPECIFICATIONS AND OTHER STRUCTURAL CONSULTANT MECHANICAL CONSULTANT FIRE PROTECTION CONSULTANT QUANTITY SURVEYOR PROJECT OWNER SHEET CONTENTS PROJ. NO. PMI-22-D-033
CONTRACT DOCUMENTS DULY SIGNED, STAMPED OR SEALED,
AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL QUADSTRUCT STRUCTURAL ROOF DECK AUXILIARY LAYOUT
PHILMEPS INC. PHILMEPS INC Consultant Engineers SHEET NO.
PROPERTY AND DOCUMENTS OF THE ARCHITECT, WHETHER
THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO
ENGINEERS
4F, 3908C Quinga St. Brgy. Pinagkaisahan, Unit 308, Valero Plaza Condominium, Salcedo Unit 308, Valero Plaza Condominium, CONSULTANT ADDRESS
Ferenzo Holdings and
P H I L M E P S I N C. DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR

MEC HANI CAL, ELEC TR IC AL, P LUMB IN G AND S PR I NKLER S YSTEM


P L A N N I N G , D E S I G N & C O N S U L T A N C Y
ALECAR S. PRADO
PROFESSIONAL ELECTRONICS & COMMUNICATION ENGINEER
USE IN THE REPETITION OF AND FOR OTHER PROJECTS OR
BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE,
WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR
OF SAID DOCUMENTS.
Makati City
ELECTRICAL CONSULTANT
Village, Makati City
PLUMBING CONSULTANT
Salcedo Village, Makati City
ELEVATOR CONSULTANT PROJECT MANAGER
FHDC Aureo Phase 6 Development Corporation
17th Floor, Lepanto Building, 8747 Paseo De Roxas, Makati City
EC2-08
Unit 30 8, Vale ro Pla za Con dom ini um, Sa lc edo Vil lag e, 124 Va ler o, Mak at i Ci ty Ph ili ppin es 12 27
philmeps.inc@gmail.com (02)8772-0040
PRC NO. 1108 Validity 13 JULY 2027 DESIGN BY: DRAW BY: Barangay San Francisco, City of San Fernando La Union, Philippines
PTR NO. 1862089 Date Issued 04 JAN 2024 A.B.V E.S.S/J.L.S PHILMEPS INC. PHILMEPS INC. C+Y DESIGN STUDIO Consultant Engineers
TIN 412 453 705 Issued at CALOOCAN CITY Unit 308, Valero Plaza Condominium, Unit 308, Valero Plaza Condominium, #1 Sto. Nino St., San Dionisio Village, Sucat, CONSULTANT ADDRESS
CHECK BY:
A.S.P FEB. 2023 Salcedo Village, Makati City Salcedo Village, Makati City Paranaque City

You might also like