Professional Documents
Culture Documents
Plumbing
Plumbing
1 1 1
F.D F.D C.O F.D
WD WD WD
2.20
2.20
2.20
2.53
2.53
2.53
HB HB HB
C.O
W.C W.C W.C
4.20
4.20
4.20
C.O
SK SK SK
2.18
2.18
1/2" Ø BLUE PVC WATERLINE PIPE
2.37
2.37
2.37
8.40
8.40
8.40
2 2 2
8.40
8.40
8.40
4.20
4.20
4.20
4.02
4.02
4.02
3.50
3.50
3.50
3 MH
3 MH
3 MH
C.O
MH MH C.O MH
MH
MH MH MH C.O
FROM MAIN CV GV
M HB
WATER SOURCE
3.50 3.50 3.50 3.50 3.50 3.50 SEPTIC TANK
E
7.00 PIP 7.00
TO LOCAL DRAINAGE 7.00
INE
E RL
1 WATERLINE LAYOUT AT 2 SEWERLINE LAYOUT 3 SANITARY LINE LAYOUT
PL-1 SCALE: 1:100 MTS. V CW PL-1 SCALE: 1:100 MTS. PL-1 SCALE: 1:100 MTS.
U EP
BL
"Ø
1/2
WD WD WD
ENGR. STEPHEN HAROLD T. RAYOSO, RMP REPUBLIC ACT 545 PROJECT TITLE : DESIGNED BY : N. PAGAYONA APPROVED BY : REVISIONS : DATE: SHEET CONTENTS:
This drawing as an instrument of service is
the property of THE AUTHOR, a registered
MASTER PLUMBER architect and as such must not be reproduced ACAD BY : N. PAGAYONA
P.R.C. NO. : 0014255
or copied in part or in whole without permission.
All drawings must be returned when no longer in "PROPOSED ONE(1) STOREY PL-1
TIN NO. : 776-336-084
use. CHECKED BY : SH. RAYOSO Ms. JESSICA QUINTO AS SHOWN
P.T.R. NO. : 1795085
PRESEDENTIAL DECREE NO. 49 RESIDENTIAL HOUSE" 09 10
"Protection of intellectual Property" works APPROVED BY : J. QUINTO OWNER
of Art Architecture, Models and Designs are
PLACE ISSUED : P.P.C creative works and considered as part of the
intellectual property of the Author LOCATION: BRGY. STA. LOURDES, PUERTO PRINCESA CITY, PALAWAN DATE : MARCH 10, 2024
DATE ISSUED : 02-18-2023
2.00
0.50
MANHOLE
0.10
0.50
1.50
1.30
1.50
100mm. THK.
CONCRETE SLAB
COVER PLUMBING NOTES
MANHOLE
1. GRADE OF HORIZONTAL :
0.60
0.50
2. CHANGE IN DIRECTION:
2.00
FORTY FIVE DEGREES (45%) WYE LONG QUARTER SIXTH EIGHT OR
0.10 0.16 0.50 0.14 0.10 0.20 0.50 0.20 0.10 SIXTEEN BENDS WHEN THE CHANGE OF FLOW IS FROM HORIZONTAL
0.40 0.40 TO VERTICAL A SINGLE 1/8 BEND COMBINATION MAYBE USED ON
10mm. Ø RSB SPACED
10mm Ø BAR
@0.20M. O.C BOTHWAYS VERTICAL STOCK AND SHORT QUARTER BENDS MAYBE USED ON
LIFTING HANDLE MANHOLE MANHOLE
C.O C.O WASTE LINE TEE AND CROSSES MAYBE USED IN VENT PIPE
0.10
0.10
3. PROHIBITED FITTING:
0.30
1.35
FINISH CLEAN OUTS ARE REQUIRED UNDER THE FOLLOWING CONDITION,
1.60
1.60
INTERIOR 10mmØ HORIZONTAL BARS
WALLS LEACHING DIGESTIVE SPACED @EVERY 3RD a) EVERY CHANGE IN HORIZONTAL DIRECTION EXCEEDING
0.30 CHAMBER CHAMBER LAYER OF CHB TWENTY TWO
AND ONE HALF DEGREES (221/2° ).
CONCRETE 150mm. THK. SLAB ON FILL b) ONE AND ONE HALF (1.5M) INSIDE THE PROPERTY LINE
WALL FOOTING WITH 12mmØ RSB SPACED
@250mm. O.C BOTHWAYS BEFORE THE HOUSE
PEA GRAVEL DRAINAGE CONNECTION.
2% SLOPE SLUDGE
BEDDING
0.25
0.15
d) AT THE END OF ANY HORIZONTAL PIPE LINE
12mmØ RSB
SPACED @100mm. 100mm. THK. GRAVEL BEDDING 6. NOT LESS THAN 30M OF AIR SPACE MUST BE LEFT BETWEEN THE
O.C BOTHWAYS ON WELL COMPACTED EARTH TOP OF SEWAGE AND THE PART OF THE VAULT ROOF SLAB.
SECTION- XX
1 SEPTIC TANK DETAILS
PL-2 SCALE: 1:100 MTS.
ENGR. STEPHEN HAROLD T. RAYOSO, RMP REPUBLIC ACT 545 PROJECT TITLE : DESIGNED BY : N. PAGAYONA APPROVED BY : REVISIONS : DATE: SHEET CONTENTS:
This drawing as an instrument of service is
the property of THE AUTHOR, a registered
MASTER PLUMBER architect and as such must not be reproduced ACAD BY : N. PAGAYONA
P.R.C. NO. : 0014255
or copied in part or in whole without permission.
All drawings must be returned when no longer in "PROPOSED ONE(1) STOREY PL-2
TIN NO. : 776-336-084
use. CHECKED BY : SH. RAYOSO Ms. JESSICA QUINTO AS SHOWN
P.T.R. NO. : 1795085
PRESEDENTIAL DECREE NO. 49 RESIDENTIAL HOUSE" 10 10
"Protection of intellectual Property" works APPROVED BY : J. QUINTO OWNER
of Art Architecture, Models and Designs are
PLACE ISSUED : P.P.C creative works and considered as part of the
intellectual property of the Author LOCATION: BRGY. STA. LOURDES, PUERTO PRINCESA CITY, PALAWAN DATE : MARCH 10, 2024
DATE ISSUED : 02-18-2023