10m High Pole On Median
10m High Pole On Median
10m high singlel arm pole on the median with 40m distance
Design Criteria:M5
Avg. Luminance (Lav) cd/m2 ≥0.5, Uniformity (U0) ≥ 0.35
Longitudinal Uniformity (Ul) ≥ 0.4, Threshold Index (Ti) ≤ 15
Walkway:P4
Avg. Illuminance (Eav) lux ≥5, (Emin) ≥ 1
Cycle track:P4
Avg. Illuminance (Eav) lux ≥5, (Emin) ≥ 1
Calculated Values:
Avg. Luminance (Lav) cd/m2 =0.65, Uniformity (U0) = 0.62
Longitudinal Uniformity (Ul) = 0.51, Threshold Index (Ti) = 7
Walkway:
Avg. Illuminance (Eav) lux = 10.05, (Emin) = 1.07
Cycle track:
Avg. Illuminance (Eav) lux = 7.24, (Emin) = 4.38
Date: 07.03.2024
Operator:
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Table of contents
Page 2
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Page 3
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 20 50 90 100 100 be displayed for this luminaire.
Page 4
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 35 79 97 100 100 be displayed for this luminaire.
Page 5
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Street Profile
Page 6
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Page 7
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Page 8
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Street 1 / 3D Rendering
Page 9
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Grid: 14 x 6 Points
Observer Position: (-60.000 m, 1.675 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.54 0.65 0.58 5
Fulfilled/Not fulfilled:
Page 10
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Grid: 14 x 6 Points
Observer Position: (-60.000 m, 5.025 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.50 0.65 0.56 5
Fulfilled/Not fulfilled:
Page 11
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Grid: 14 x 6 Points
Observer Position: (-60.000 m, 9.450 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.50 0.65 0.56 5
Fulfilled/Not fulfilled:
Page 12
10m high pole with 40m spacing
07.03.2024
Operator
Telephone
Fax
e-Mail
Grid: 14 x 6 Points
Observer Position: (-60.000 m, 12.950 m, 1.500 m)
tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.53 0.65 0.58 5
Fulfilled/Not fulfilled:
Page 13