E-17-16130-VFD-Version 2.0

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Data Sheets for Electrical Works

Abu Dhabi Sewerage Services Company


(ADSSC)

Project Reference: VARIABLE FREQUENCY


Project Title DRIVE E17/16130
(VFD)
Project Location Date
Manufacturer Supplier
Submittal Status: + Preliminary + Detailed Engineering + Approval + Final + AS BUILT

TECHNICAL SPECIFICATIONS
1.0 Reference Standards
Specification Standard 1.01 BS EN/IEC/UL 61800-2/61800-3/UL508C
1.02 Motor in Hazardous Area? (BS EN/IEC 60079-
14 applies) (Y/N)
1.03 Utilisation Category – “Pumps”
1.04 CE – Marking (Y/N)
2.0 Test Certificates
Certificate Numbers and 2.01 ASTA / KEMA / DNV / LRS / GL / BV / UL / CSA
Date of Issue / TUV
2.02 Routine Tests / Factory Tests
2.03
3.0 Electrical Data
VFD (Open) 3.01 Location – Tag No.
3.02 Rated Insulation Voltage (Ui)
3.03 Rated Operating Voltage (415V/3Phase)
3.04 Rated Impulse Voltage (Uimp)
3.05 Rated Operating frequency (50Hz)
3.06 Rated Current at 50°C – AC3/415V (Ie)
3.07 Control Supply Voltage (110V/50Hz)
3.08 Type 2 co-ordination (Y/N)
3.09 Aux. Contacts configuration – NO/NC
3.10 I/O configuration
3.11 Current limit (0-100% Adjustable)
VFD (Standalone) 3.12 Overload capacity (110%)
3.13 Acceleration Rate
3.14 Deceleration Rate
3.15 Minimum speed (0-100% adjustable)
3.16 Maximum speed (0-100% adjustable)
3.17 Speed Regulation (Open/Close loop)
3.18 Transient/Voltage surge protection (Type)
3.19 RC Snubber network protection (Y/N)
3.20 Serial Communication
3.21 Communication protocol
3.22 IP Rating (IP42/IP54)
3.23 Method of Cooling
3.24 Overload and Short-circuit protection devices

Variable Frequency Page 1 of 2


ADSSC/TDS Electrical E17/16130 Rev: 02 Jan. 2011
Drive (VFD)
Technical Data Sheets for Electrical Works
Abu Dhabi Sewerage Services Company
(ADSSC)

LCD Display Specification:


Intelligent Interface 3.25 4-line, 20-Character alphanumeric display
Key LCD Panel 3.26 Backlit LCD for easy monitoring
3.27 Directly readable actual Text Messages (no
Codes).
3.28 Exhaustive List of Fault memory to support
maintenance activities.
3.29 Detachable key panel that facilitates "Up/down
load" of parameters from one drives to another
Variable Frequency Drives of similar make and
Series Type.
List of Key Parameters Displayed on
LCD Panel:
3.30 Incoming Voltage
3.31 DC Bus Voltage
3.32 Output Voltage
3.33 Output Torque
3.34 Output Power
3.35 Output Current
3.36 Motor Speed
3.37 Reference Speed
3.38 Output Frequency
3.39 Operating Hours
3.40 Drive Temperature
3.41 kWhr
List of Key Faults and Alarm
Conditions Displayed:
3.42 Input Fuses
3.43 Input Line Contactor Fault
3.44 Short-circuit in the rectifier bridge
3.45 Supply phase loss
3.46 Choke Temperature High
3.47 I/O Communication Error
3.48 Communication Fault
3.49 Measurement loss
3.50 Inverter Short Circuit
3.51 DC Over- and Under-Voltage
3.52 Drive Temperature High
3.53 Motor phase loss
3.54 Motor stall protection
3.55 Motor Temperature High
3.56 Overcurrent
3.57 Overspeed / Frequency
3.58 Under load
3.59 Earth fault

Variable Frequency Page 2 of 2


ADSSC/TDS Electrical E17/16130 Rev: 02 Jan. 2011