ULTRASONIC EXAMINATION REPORT

Date of REPORT No & Rev no: GPTI-QICL-J931-MUT-004 PAGE: 1 OF 2


Examination: 25.02.2023
Client: AIR PRODUCTS/NEOM / QICL Job No:- J931
Location: QICL,HAMRIYAH PHASE 2 Item Id: J931-11-2022
Project: NEOM GREEN HYDROGEN ELEMENTS Drawing No: - QICL-J931-11-32-DRG-GEN-01 REV-D /
PM210011-QI700-9V3-00015 Rev-02
Connecting cable type and length: LEMO TO MICRODOT Special attachment/ Equipment/Blocks: N/A
Examination Method and Technique : CONTACT METHOD AND PULSE Tag No:
ECHO
Calibration Block No: QICL-J931-CB02 Thk: 63mm Reference Reflectors: 2.5mm SDH
CALIBRATION DATA
Reflector Beam Reflector
Probe Reflector No. % Echo Beam Path % Echo % Echo Beam Path
No Path No
45 1/4 80 21 1/2 56 45 3/4 26 69

Acceptance Criteria: ASME SEC VIII Div-2 ED 2021


Damping / Reject Setting: OFF/ZERO QICL-J931-11-32-MUT-01 Rev-C
UT Procedure & Rev.: QICL-J931-11-32-MUT-01 Rev-c
PROBE TYPE TR/00 45 0 60 0 70 0
Flaw Detector: USM 35 X DAC
Make WK WK NA NA

Sr. No. 42685 22297 NA NA Serial No: 12647a

Crystal Size / Diameter Calibration Certification No: GPTI/UT/CAL -088/2022


mm 10Ø 10Ø NA NA

Frequency MHz 5 MHZ 4MHZ NA NA Calibration Certificate Due Date : 24.03.2023

Base Metal Type & Thickness: CS,& 63mm


Primary Reference dB 1st BWE@80% of FSH 52dB NA NA
Weld Type / Configuration: DOUBLE V BUTT
Scanning Sensitivity dB +6 +6 NA NA
Test Range (mm) 0-150 0-250 NA NA Couplant Brand Name & Type: POLYCELL
Surface Condition Scan Face : FROM TOP SURFACE
/Preparation AS CLEANED
Access Limitations (if Any):
* 100% UT(45 TRANSVERSE DIRECTION) WAS CARRIED OUT ON VESSEL J931-11-2022 LONG SEAM WELD

* NO RECORDABLE INDICATION WAS OBSERVED.


* FOUND ACCEPTABLE AS PER SPECIFICATION.
* FOR WELD DETAILS REFER CONTINUATION SHEET.

ACCEPT REJECT

TEST RESULT ✘

CLIENT REP. : AI / TPI. :


TECHNICIAN : SANDIP BHOWMICK
NAME : NAME ;
LEVEL : II
SIGNATURE : SIGNATURE :
SIGNATURE :

DATE : 25.02.2023 DATE : DATE :

Report Form no-GPI/NDT/UT/001, REV-4 (Rev-date : 26/07/2020)


Disclaimer : This report is a property of GPTI & valid only if signed and stamped by GPTI Technician. Under no Circumstances will GPTI accept any
liability for loss or damage; consequential or otherwise caused by use or misuse of the test results. The test report shall not be reproduced in full or in part for
any promotional or publicity purpose without the written consent from GPTI
ULTRASONIC EXAMINATION REPORT
(CONTINUATION SHEET)

DATE : 25.02.2023 REPORT NO. & Rev no: GPTI-QICL-J931-MUT-004 PAGE : 2 OF 2


RESULT
Location no weld Distance from Depth from Echo Defect
WELD I.D. Welder ID & probe Beam path Reference 'O' scan face (mm)
height % Length Flaw Type
Size DAC (mm) ACC REJ

WH1107
(J931-11-22 ) WH1109
P
W99 45T 3065 mm NSD
LS-1
WH361
WH1141
(J931-11-22 ) WH1030
P
WH1151 45T 3065 mm NSD
LS-1A
WH1150
WH1030
(J931-11-22 ) WH973
WH1048 45T 3065 mm NSD P
LS-2A WH1151

WH1141
WH1069
(J931-11-22 ) WH1153 P
45T 3065 mm NSD
LS-22 WH361
WH1155

WH1068
WH1019
(J931-11-22 ) WH1048 P
45T 3065 mm NSD
LS-22A WH253
WH1151

WH1031
(J931-11-22 ) WH1141
WH253 45T 3065 mm NSD P
LS-23 WH1152

WH1031
(J931-11-22 ) WH1037
WH253 45T 3065 mm NSD P
LS-23A WH1159

WH1030
(J931-11-22 ) WH973
WH1151 45T 3065 mm NSD P
LS-24 WH1155

WH1141
(J931-11-22 ) WH1069
WH253 45T 3065 mm NSD P
LS-24A WH361

CLIENT REP. : AI / TPI. :


TECHNICIAN : SANDIP BHOWMICK
NAME : NAME ;
LEVEL : II
SIGNATURE : SIGNATURE : SIGNATURE :

DATE : DATE :
DATE : 25.02.2023

Report Form no-GPI/NDT/UT/001, REV-4 (Rev-date : 26/07/2020)


Disclaimer : This report is a property of GPTI & valid only if signed and stamped by GPTI Technician. Under no Circumstances will GPTI
accept any liability for loss or damage; consequential or otherwise caused by use or misuse of the test results. The test report shall not be
reproduced in full or in part for any promotional or publicity purpose without the written consent from GPTI
Report Form no-GPI/NDT/UT/001, REV-4 (Rev-date : 26/07/2020)