Exp 03
Exp 03
N2 + O2 2NO (1)
While most of the NOX that is emitted in automobile exhaust is in the form of NO nitrogen
dioxide begins to form by the reaction of NO with excess oxygen.
NO2 is a brown pungent gas. Concentrations of 20-50 ppm NO2 are irritable to the eyes. At
Only 150 ppm there is danger of strong local irritations especially to the respiratory organs.
This experiment is based upon the fact that NO2 dissolves in aqueous solutions to form nitrite ion.
Nitrite reacts with sulfanilic acid and 1-naphthylarnine in acetic acid medium to give an azo dye
which can be analyzed spectrophotometrically.
Procedure
(a) Sampling
• Obtain four membrane filters handling them only by edge. Finger prints on the surface will greatly
impair their filtering capacity. They should be handled gently to avoid poking holes in them
cracking them. Identify the filters by marking each with one or more dots on the edge using a felt
tip pen. Weigh each filter separately on an analytical balance to the nearest 0.0001 g.
• Place the first filter in the filter holder, and carefully connect the two holder halves tightening them
snugly and being sure that the filter seats property. Attach the membrane filter apparatus to an
empty 60 ml syringe.
• Rinse four other 60 ml syringes with a few milliliters of indicator reagent and then fill two with
exactly 25 m1 and two more with exactly 10 ml of the NOX indicator. Make sure in each case that
air bubbles have been expelled along with any excess solution. Cap the syringes and number them
following the same scheme that was used for the filters. Carry out duplicate determinations using
the following procedures on cigarette smoke and on automobile exhaust.
Cigarette smoke
• Connect the cigarette holder to the filter holder (see figure 1). Light a cigarette malting sure that
the entire tip is smoldering. Immediately place it in the cigarette holder and use the empty 60 ml
syringe to draw a 35 ml puff of two-seconds duration. Between puffs, the filter apparatus should
be disconnected from the syringe to expel the filtered smoke into the air. Any visible cloudiness
in the filtered smoke indicates that the millipore filter is either perforated or seated incorrectly.
Wait one minute and draw a second 35 ml puff. After the second puff, the cigarette and filter holder
should be transferred to the first indicator syringe containing 25 ml of reagent. When one minute
has elapsed since the second puff draw 35 ml, two-second puff through the filter into the indicator
syringe. This will necessitate pulling the plunger to the 60 ml mark.
• Disconnect the fitter holder from the syringe, cap the syringe, and shake vigorously. Allow the
filtered smoke to remain in the syringe for at least 30 minutes with occasional shaking. The
cigarette should be discarded and the membrane filter removed from its holder. When the colour
development is complete (at least 30 minutes) expel all gas from the syringe while retaining
exposed indicator in the syringe. Draw 25 ml of unexposed indicator in the syringe. This dilution
to a total of 50 ml is necessary to produce a colour intensity which can be read with the
spectrophotometer.
• Repeat this procedure with a second cigarette.
Filter holder
Cigarette
Holder
Cigarette
Tubing 60 ml syringe
Cigarette Smoke Analyzer
Figure 1
(1) Using a 5 ml syringe, add 0.5 ml of 5.0 µg/ml NO2- solution to a 25 ml graduated cylinder.
(2) Repeat the above procedure with 1.00 ml, 2.00 ml, 3.00 ml, 4.00 ml, 6.00 ml,8.00 ml and 10.00
ml of stock solution. The concentration of NO2- represented by the four standard am 0.20 µg/ml,
0.40 µg/ml, 0.60 µg/m1, and 0.80 µg/ml, respectively. All four standard solutions should be kept
in stoppered test tubes for 15 minutes or longer to ensure complete colour development.
• With the spectrophotometer set to a wavelength of 550 nm, measure the absorbance of the four
standards using unexposed NOX indicator as a blank. Measure the absorbance of the four exposed
indicator samples. Make a standard curve and use it to determine the concentration of nitrite ion
(NO2-) in each exposed indicator solution.
• Use equation (5) to calculate the number of micrograms of NOx per liter.
mg NOx / m3 = µg NOX / L = (µg N02-/ml) (Vi / Vg) (1.39) (1000 ml/L) -------- (5)
where Vi is the total volume of the indicator used, (50 ml for smoke, 10 ml for exhaust), V g is the
volume of gas sampled, (35 ml or 50 ml) and 1.39 is the factor for converting N02- to NO2.
Where R is gas constant (0.082 L atm/K mole), T is the absolute temperature (300°K), P is the
pressure (1 atm), and 46 is the molecular weight of NO2.
Discussion
1. What are the sources of NOX ?
2. Explain the effect of NOX on environment?
3. Explain the health effect of NOX ?