HGM1250, 1600

Molded Case Circuit Breakers


HGM1250, 1600
Molded Case Circuit Breakers
Applicable to Various Location

Easy to remove, simple


to install and repair with
inscription window

Residence Building

Reliable short circuit capacity


offering more stable and better
protection of electric appliances

Industry

IEC60947-2 certified for


industrial installation
Product Features

The HGM type maximizes diversity in product selection by developing a variety of products.
In addition, the newly developed HGM1250&1600 MCCB is an electronic type, so its characteristics can be adjusted.

1,250 AF
1: Long time delayed tripping current.
3: Short-time delayed tripping current
Upon Request Type 5: Instant opening current

I1 0,7 0,8
0,9
I2 5 6
7
I3 5 6
7
t1 0,6 0,95 4 8 4 8
0,5 1 xIn 3 10 xI1 3 10 xI1
0,4 2 2
t2 t1(s) t2(s) O n I ² t Of f L3 LED
8
4 12 0,3 0,05 0,1
L1 L2 L3
2 16 0,2 0,2
I1 I2 I3 @ 6 I1 1 20 0,1 0,05 0,3
Over current
0,5 I>0.2xIn I>I 1
LED

2: Long time delay interval L2 LED


4: Short time delay interval Operation LED
L1 LED

· The desired value can be set between %40 and %100 of I1 switch
and In breaker value.

· Long time delay setting range is from 0.5 to 20 seconds.


As tripping on 6I1 is time switched, tripping formula for over
current outside 6I1 (Tripping time)=[(6I1)2xt1]/I2

· I2 switches may be adjusted in 2 to 10 times the current I1

· I2t "OFF"; When larger current pass over circuit breaker other than
the set I2, trips the circuit breaker at the end of fixed time delays.
· I2t "ON"; There are time delay in proportion with (8xI1)2 at the "ON"
section. Card detects period of time in inverse proportion with the
square root of the tripping current. (Tripping time)=[(8xI1)2/I2]xt2

· I3 switch can be adjusted between 2 and 10 times the current I1.
There is no any delay function.

·L
 1, L2, L3; Indicates on which phase the over current passes through.
· I>0.2xIn; Indicates that the card is operational and current passes
through the circuit breaker.
· I>I1; Indicates that current passes through the circuit breaker and if
the situation does not return to normal, In accodance with release
curve the circuit breaker will trip after a while.

1,600 AF

Protection characteristics and current setting


Rated (CT) current [In] (A) 1,600
Rated current In x 0.4 0.5 0.6 0.7 0.8 0.9 0.95 1.0
LTD
setting [I1] (A) 640 800 960 1,120 1,250 1,440 1,520 1,600
Instantaneous current
INST I1×2-3-4-5-6-7-8-10
setting [Ii] (A)
Red light I>0A
LED
Green light I > 0.4×In
indication
Yellow light I > I1
Model Selection Table
Things in common Things in common
Rated insulation voltage, Ui 1000 V Suitablilty for isolation Yes
Rated operational voltage, Ue 690 V
Utilization category B
Impulse withstand voltage, Uimp 8 kV
Overload, short-circuit and Pollution degree 3
Protection function
instantaneous protection Reference standard IEC60947-2

Model HGM1000 HGM1250 HGM1600

Frame (AF) 1,000 1,250 1,600

Pole (P) 3,41) 3,41) 3

Rated current, at 40˚C, Electric (A) 1,000 1,000/1,250 1,600

Recognition code
S S S
for order

AC660/690 V 25 25 25
Rated short-circuit
breaking capacity AC480/500 V 35 35 35
[Icu] (kA rms)
AC440/460 V 45 45 45

AC380/415 V 70 70 70

AC220/240 V 100 100 100

AC660/690 V 12.5 12.5 17.5

AC480/500 V 17.5 17.5 24.5


Service breaking capacity
AC440/460 V 22.5 22.5 31.5
[Ics] (kA rms)
AC380/415 V 65 65 50

AC220/240 V 50 50 70

Rated short-time withstand current[Icw] (kA) 1s 15 15 12*In

Endurance Mechanical 10,000 10,000 10,000


(Durability) Electrical 3,000 3,000 3,000

Trip Device

● ● ●
Long time [LT, I1] 0.4-0.5-0.6-0.7-0.8-0.9-0.95-1×In 0.4-0.5-0.6-0.7-0.8-0.9-0.95-1×In 0.4-0.5-0.6-0.7-0.8-0.9-0.95-1×In
Electronic
Short time [STD, I2] 2–3–4–5–6–7–8-10×I1 2–3–4–5–6–7–8-10×I1 2–3–4–5–6–7–8-10×I1

Instantaneous [INST, I3] 2–3–4–5–6–7–8–10×I1 2–3–4–5–6–7–8–10×I1 2–3–4–5–6–7–8–10×I1

Accessory

Auxiliary switch AUX ● ● ●


Alarm switch ALT ● ● -

● ● ●
Internal
Shunt trip SHT

Undervoltage trip UVT ● ● ●


Rotary handle Extended TFH ● ● -

Motor operator MOT ● ● ●


Mechanical interlock MIF ● ● -

Lock Mechanism with Key ● ● -

Draw-out - - -

External TDM(LINE/LOAD) - - -
Plug-in
TDM(LINE Only) - - -

Cage terminal block CTB ● ● -

Insulation terminal cover TCF ● ● ●


Insulation barrier TQQ Standard Standard Standard

Terminal extentions TBB Standard Standard Standard

Installation and dimensions

Front connection Terminal busbar Terminal busbar Terminal busbar

Connection/Installation Rear connection - - -

Plug-in - - -

a (3/4P) 210/280 210/280 210


Dimensions
b 370 370 370
(mm)
c 124 124 155

※ 1) 4 pole arrangement : Basic specification is N-R-S-T


Dimensions

HGM1000/1250

Unit : mm
3P 4P
70 70 47 70 70 70
70 16 70 70

14.5
4-Ø6 or M6 Tap 6-Ø6 or M6 Tap
23 Mounting Screw
M6xL50
280

46 54.5
45 8
Ø13 46.5

14.5
70.25 40.25
40.25

338

340
110.5

274
325
370
496
110
61.25

105 Hexagon Head Bolt


M12xL55
71.5
23 Mounting Screw
M6xL50
70 70 70

14.5
45 45 Ø13 43.5 22.5 Ø13
210 121.5
124 45 45
138.5 280
181
264

40.25
40.5

40.5

40.5

40.25

40.25
110.5
110.5
111
111

186.75
186.75

105 209 209 105 280 280

Dimension of Dimension of Dimension of Dimension of Dimension of Dimension of


Panel Cover Cutting - Panel Cover Cutting - Panel Cover Cutting - Panel Cover Cutting - Panel Cover Cutting - Panel Cover Cutting -
Handle Exposure Handle Test Button Handle Trip Unit Handle Exposure Handle Test Button Handle Trip Unit
Exposure Exposure Exposure Exposure

HGM1600

Unit : mm
70 70 42,5
70 20

4-Ø6,5 or M6 Tap
16
Mounting Screw
M6 x L50
280
154
46
307,5

338
370
110

70,5
55,5

64

105
154

16 46
Mounting Screw 45
M6 x L50 70
15

Ø13 Ø13
152,5
32

45 45 Hexagon Head Bolt


159,5 M12 x L55
210
170
203
285
15

Ø13
Hexagon Head Bolt
32

M12 x L55
46
46

46
110
110

200

105 210 210

Dimension of Dimension of Dimension of


Panel Cover Cutting - Panel Cover Cutting - Panel Cover Cutting -
Handle Exposure Handle Test Button Handle Trip Unit
Exposure Exposure
Characteristic Curve

Operation Characteristic Curve

HGM1000/1250 Time Current Curves HGM1600 Time Current Curves

10000,00 10000,00

I1=(0,4-1)In I1=(0,4-1)In

1000,00 1000,00

t1=0,5-20s at 6I1 t1=0,5-20s at 6I1


t=(6I1)2/I2t1 t=(6I1)2/I2t1
100,00 100,00
Time (sec)

Time (sec)
10,00 10,00
I2=(2-10)I1 I2=(2-10)I1
t2=0.05-0,3s t2=0.05-0,3s

1,00 1,00

I2t on:t=(8I1)2/I2t2 I3:(2-10)I1 I2t on:t=(8I1)2/I2t2 I3:(2-10)I1

0,10 0,10
I2t off:t=t2 I2t off:t=t2

0,01 0,01
0,10 1,00 10,00 0,10 1,00 10,00

Current (xIn) Current (xIn)

Energy-Limiting Characteristic Curve

I2t Curve I2t Curve


HGM1000/1250 HGM1600
1,000,000 1,000,000

100,000

100,000
Energy (kA2s)

Energy (kA2s)

10,000

10,000

1,000

100 1,000
10 100 10 20 30 40 50 60 70 80 90 100

Current (kA) Current (kA)

Current-Limiting Characteristic Curve

HGM1000/1250 Ipeek Curve HGM1600 Ipeek Curve


1,000 1,000

100 100
Current (kApeek)

Current (kApeek)

10 10

1 1
10 20 30 40 50 60 70 80 90100 10 20 30 40 50 60 70 80 90100

Current (kA) Current (kA)


Order Information

Ordering guidelines

① HGM ② 1250 ③S ④ 3P ⑤ EN ⑥ BS ⑦ 00 ⑧ 00 ⑨C ⑩ 01250 ⑪

① Type

② Frame

③ Short-Circuit Breaking Capacity

④ Number of Poles

⑤ Product Description

⑥ Mounting

⑦ Auxiliary Contact & Alarm Switch(AUX/ALT)

⑧ Shunt Trip & Under Voltage Trip Devices(SHT/UVT)

⑨ Frequency

⑩ Rated Current

⑪ Trip Device

① Type ④ Number of Poles ⑦ Auxiliary Contact & Alarm Switch(AUX/ALT) ⑩ Rated Current

HGM MCCB 3P 3 pole 00 Without 01000 1,000 A


4PN2) 4 pole(NRST) 01250 1,250 A
01600 1,600 A

② Frame ⑤ Product Description ⑧ Shunt Trip & Under Voltage Trip Devices(SHT/UVT) ⑪ Trip Device

1000 1,000 AF MCCB Electronic 00 Without Electronic


1250 1,250 AF EN Normal - ETU
1600 1,600 AF

③ Short-Circuit Breaking Capacity ⑥ Mounting ⑨ Frequency


1)

S 70 kA Terminal Bus Bar C 50/60 Hz in common


BS3)
(Straight Type)

※ 1) In case that the rated voltage is AC380/415 V


2) In case of 4P, The N phase is located on the left.(NRST)
3) A straight busbar is provided as standard.
Korea

Head Office Hyundai Bldg, 75, Yulgok-ro, Jongno-gu, Seoul, Korea

Sales Office 5th Floor 55, Bundang-ro, Bundang-gu, Seongnam-si, Tel : +82-31-8006-6780, 6786 Fax : +82-31-8006-6629
Gyeonggi-do, Korea

Factories 700, Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea


223, Sapyong-ro, Nam-gu, Ulsan, Korea (Seonam)

R&D Center 17-10, Mabuk-ro 240beon-gil, Giheung-gu, Yongin-si,


Gyeonggi-do, Korea

Branch Offices

Atlanta 6100 Atlantic Boulevard, 2nd FL., Norcross, GA30071, U.S.A Tel : +1-678-823-7839 Fax : +1-678-823-7553

Osaka 5th Floor Nagahori Plaza Bldg. 2-4-8 Minami Senba, Chuo-ku, Tel : +81-6-6261-5766~7 Fax : +81-6-6261-5818
Osaka 542-0081, Japan

Moscow World Trade Center, Ent.3, #703, Krasnopresnenskaya Nab.12, Tel : +7-495-258-1381
Moscow, 123610, Russia

Dubai Unit 205, Emaar Square Building No.4 Sheikh Zayed Road, Tel : +971-4-425-7995 Fax : +971-4-425-7996
Dubai 252458, U.A.E

Frankfurt Mendelssohn strabe 55-59 Frankfurt 60325, Germany Tel : +49-69-4699-4988

Bangkok 19th Floor, Unit 1908, Sathorn Square Office Tower, 98 North Tel : +66-02-115-7920 Fax : +66-2-115-7898
Sathorn Road, Silom, Bangrak, Bangkok 10500, Thailand

www.hyundai-electric.com

You might also like