TECHNICAL DATA SHEET APPROVAL

REQUEST (TDS)
HCPL/02012021/01 Rev: 0 Page 1 of 1
PROJECT: PROPSED CANCER CARE FOUNDATION,CHANDRAPUR PROJECT No:
Contractor : Harsh Constructions Pvt. Ltd.

SERIAL NO: JUNE 1 5 3 REV No: R 0 DATE : - 07 JUNE 21

Item: INTEVIO CONTROLLER Manufacturer & Model No.: Honeywell BOQ Sr. No.: 14.19

HCU-2000
list of make praposed in tender : a. Tyco
b.Bosch
c. Arecont Vision
d. Honeywell
Location Of Use : Chandrapur Cancer Care Foundation Hospital Project
Technical Details : As attached
Attachments :
Sample Size Brochure Others
YES NO YES NO
Catalogues
attached

For Contractor : Technical Details Specification Attached for an approval.

Comments

Submitted by : Sanjay D Dalvi Date: Signature:


For CBRE
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:


For CLIENT: ( In Case Client Approval is Required )
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:


HCU-2000
INTEVIO
CONTROLLER
• Complies to international standards
• Plug-and-play for easy commissioning
• Intuitive set-up with step-by-step guided interaction with
the LCD front panel
• Fully configurable keys to achieve any task at the press of
a button
• Modular architecture : Expandable upto 128 speaker lines
• Dual channel audio capability
• Flexible amplifier backup modes to ensure low cost of
ownership and high reliability
• Digital volume control on all inputs/outputs
• Comprehensive fault detection and indication
• Integrated voice alarm and public address system
controller with built-in 500W amplifier
• Numerous user friendly design to increase operation
efficiency: plug and play, record and play, interaction
between LCD and buttons, etc
• Save total ownership cost by implanting recorder, timer,
audio monitor and onefor-all backup amplifier solution

ABOUT THE INTEVIO PUBLIC DESCRIPTION


ADDRESS AND VOICE ALARM
RANGE HCU-2000 controller is the core unit of INTEV IO VA/
PA system which performs the audio storage, signal
processing, routing, control and supervision functions
for the whole system. With the built-in 500W Class-D
Honeywell’s INTEVIO Public Address and Voice Alarm amplifier, the single controller can work as an
system is the ideal solution for single buildings. It is an 8-zone VA/PA system. When more power and speaker
integrated solution that can provide better stability, zones are needed, it can be expanded by using
costsavings, and higher user experience and external power amplifier HAM-2000 and zone
performance: expander HEX-8/HEX-24.
FUNCTIONS
The controller integrates multiple Allow all calls even when the CPU Cost saving amplifier backup solution
functions such as audio storage, malfunctions IHCU-2000 has built-in amplifier
playback, zone control, audio monitoring, If the CPU of the HCU-2000 fails the automatic switch-over function and
scheduled broadcast and fault diagnosis, INTEVIO system will still allow the user to allows different amplifier backup
etc. make paging announcements (All Call) configurations to address the needs of
using the PTT Microphone or the call different applications. To back up all the
stations in case of emergencies. amplifiers in the system, a minimum of
Intuitive interaction design between one standby amplifier is sufficient, which
buttons and screen Scheduled broadcast with built-in timer greatly reduces the ownership cost on
After pressing a button on the front panel, HCU-2000 has a built-in timer and standby amplifiers.
clear instructions will pop up on the LCD supports configurable scheduled
screen to guide the user what to do next. broadcast without extra timing device.
This increases the operational efficiency
Record and play
HCU-2000 allows Users to record the
Automatic fault diagnosis temporary messages into its built-in
The INTEVIO system is a fully monitored 1GB memory with the PTT microphone
system with the ability to supervise and or the call station and broadcast it
report faults related to the main power, without configuration. It’s a function for
backup power, CPU, microphone, operation efficiency improvement,
amplifiers, speaker circuits and the dry especially for the application such as
contacts. The fault details will be shopping mall/supermarket where the
displayed on the LCD screen and promotion message needs to be
fault .logs will be stored in the internal frequently updated.
memory
Technical Specification

Main power AMPLIFIER CONTROL INTERFACE


AC 220-240V, 50/60Hz
supply voltage
Channels 3 (channel 1, channel 2 and backup amplifier)
Backup power
supply voltage AC 220-240V, 50/60Hz
Output signal 1.4V
Main power THD <0.5%
T10AH 250V
supply fuse
Self-test signal, amplifier fault signal and
Control signal
Rated power 750 W power saving control signal
LOUDSPEAKER CIRCUITS
MICROPHONE INPUT

Input sensitivity -65±3dBV Output channels 8 (with group A and group B)

Input impedance 250Ω Maximum 500W


loudspeaker load
Frequency 90 Hz -13KHz
response CONTACT INPUT /OUTPUT

SNR >50dB (with A-Weight) Contact inputs 10 (monitored)


AUXILIARY INPUT 8 (NO, NC & COM), “fault”
Contact outputs
output, “emergency” output
Channels 2
Max . working
Input sensitivity 1V (0dBV) AC 250V/DC 30V
voltage for outputs

Input impedance 10 KΩ Max . working


2.5A
current for outputs
Frequency 85Hz-18KHz
response OTHERS

SNR >77dB (with A-Weight) DC power output 24V/1A

Monitoring 2W/8Ω
MIC/LINE INPUT
loudspeaker
Input sensitivity -50dBV/0dBV, selectable Ethernet port 10M/100M
Input impedance 10 KΩ Memory capacity 1GB
Frequency
85Hz-18KHz OPERATING CONDI TIONS
response
SNR >77dB (with A-Weight) Humidity < 95%, without condensation

Phantom power DC 24V, switchable Operating -10°C~+50°C (14°F~+122°F)


temperature
CALL STATION INTERFACE Storage
-40°C~+70°C (-40°F~+158°F)
temperature
Input signal 2V
WEIGHTS AND DIMENSIONS

Input impedance 20 KΩ Product dimension 482 mm×133.5 mm ×420 mm


(W×H×D)
Output signal 2V
Packagedimension 580 mm×279 mm ×552 mm
Output (W×H×D)
20 KΩ
impedance
Net weight 14.3Kg
Frequency
85Hz-18KHz
response

AUDIO OUTPUT

Channel 1, channel 2 and


Output channels
recording output

Output signal 1V (0dBV)

THD 2V
Certifications and Approvals Ordering Information
Category Region Certification Description Ordering Information
Safety Europe CE Certified
CONTROLLER HCU-2000
Safety Global CB Certified

For more information,


www.partnerconnect.honeywell.com
Call: 1-800-103-0339
Email: HoneywellSecurity&Fire@honeywell.com

Honeywell HBT India Buildings HCU-2000


Unitech Trade Center, 5th Floor, Sector-43, INTEVIO
Block C, Sushant Lok Phase - I, CONTROLLER
Gurgaon - 122 002

www.honeywell.com © 2019 Honeywell International Inc.

You might also like