Professional Documents
Culture Documents
BOQ OLT PKE06 To JAW-JI-PNG-2091
BOQ OLT PKE06 To JAW-JI-PNG-2091
1 OLT,AGG
1.1 OLT,AGG
Workload including but not limited to:
1.1.1 350000475604 OLT Outdoor cabinet (pole type,including the installation of ground cable and power cable) Installation & Acceptance The Sow includes installation of Mini OLT outdoor cabinet(Including OLT equipment and rectifier Module,600 mm (H) × 220 mm (W) × 380 mm unit S
(D))and Battery cabinet (Including one bank 14Ah battery with 4 units,600 mm (H) × 220 mm (W) × 380 mm (D)). Layout and connection of
power/grounding cables, optical cables, and laying AC cable to the existing Power meter box.
1.1.2 350000480387 Supply and install 700*800*800mm steel cage for outdoor pole mounted OLT cabinet (LN specification) set M+S
Workload including but not limited to:
1.1.4 350000475607 Supply and install of labelling for OLT Outdoor cabinet(pole type) 1.Provision and installation of 20 pcs label for OLT Outdoor as per specification. set M+S
2.Make OLT label (paint) according to Linknet standards and affixed to the device & then sprayed using pilox)
1.1.7 350000475610 Supply and install steel cage for outdoor cabinet (LN specification) Workload including but not limited to: set M+S
Construction of steel cage with pad lock for outdoor cabinet (LN specification) as per specification, including bolts and accessaries.
1.The actual space permit fee will escalate to LN with email and aprove by Linknet
1.1.8 350000480384 AGG site space Permit fee(Legworks + Payment) 2.Fund advance fee will 6% of the actual space permi fee unit S
3.Permit provide by Suncon with work permit and permit letter from space owner
1.1.10 350000475613 Service for Permit of New PLN connection 16A 1 phase Workload including but not limited to: Site S
Apply and payment to PLN Permit.For Termination of Upgrade PLN connection for 16A 1 phase.
Workload including but not limited to:
1.1.11 350000475614 Supply and Installation of KWH 1-Phase box with 2 MCB Supply and Installation of KWH 1-Phase Power Meter,2pcs 16A MCB and Power meter Box(The dimension of KWH Box is 90mm*20mm*60mm.) Site M+S
according to Indonesia PLN requirement, included new power cable if needed.
1.2 Survey and design for OLT