A WATERPROOFING
25mm thick smooth finish Lean concrete before damp proof/ WP membrane installation. (By others) BY OTHER
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapefoil-dpm
HYDROPHOBIC WP ADMIXTURE
To supply and does in "Mapei" IDROCRETE WP hydrophobic waterproofing admixture pore blocking waterproofing admixture certified by
Driveway Roof Singapore Green Label that significantly reduces the absorption of water (BS 1881: PT 122: 1983) and water permeability (DIN 1048:Part m³ 75.00
5) in cured concrete; dosed at 1.0 litre per 100kg cement, all in accordance to manufacturer's specification and instruction.
https://www.mapei.com/sg/en/products-and-solutions/lines/products/detail/idrocrete-wp
Self Adhesive Bituminious WP Membrane to Lower Basement Tank Slab & Upturn 300mm
Work Below Ground To supply and lay "Mapei" POLYSTICK TU PLUS, 2mm thick self adhesive (WITH ADESO TECHNOLOGY) bituminous membrane,
Floor Slab for Basement reinforced wih glass fibre with bi-adhesive surface at lateral and endlap for overlapping on the lean concrete and terminate at upstand of m2 75.00
carpark beam, all strictly in accordance to manufacturer's specification and instruction.
Treatment to pile head with 100mm upturn and 150mm overlapping with membrane on horizontal and tie with flexiband nos 25.00
SUPPLY ONLY
To form 50mm height angle fillet on pile head and ground beam with MAPEGROUT PATCH 218 high strength patch mortar (By others)
RM25/25kg bag
Upturn 100mm to ground beam by applying a coat of PLASTIMUL MY as primer and fix on position with flexiband m 15.00
https://cdnmedia.mapei.com/docs/librariesprovider52/products-documents/polystick-tu-plus.pdf?sfvrsn=769c84cf_8
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapegrout-patch-218
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/plastimul-my
3 To treat floor and internal wall corner with MAPEFLOOR EP 19 MT high strength epoxy mortar m 55.00
4 Protection Layer To supply and lay 1 layer of 0.25mm thk MAPEFOIL DPM 250, low density polyethylene sheet as protection layer m2 7.00
5 To be over-laid with reinforced concrete wearing layer for vehicular traffic (r.c. specification and design details by others) BY OTHER
At every 3rd panel interval cast straight down joints with MAPEJOINT FB Filler board and filled with MAPEFLEX PU 70 SL high
6 SUPPLY ONLY
performance PU sealant and MAPEFOAM, backer road (12.5mm width x 12.5mm depth)
To form surface contraction joints with 12.5mm width x 25mm depth groove to be introduced at every 1.5m x 1.5m span with filled with
7 MAPEFLEX PU70 SL high performance PU sealant to groove. BY OTHER
https://www.mapei.com/id/en/products-and-solutions/lines/products/detail/purtop-1000
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/primer-sn
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapefloor-ep19-mt
To form expansion joints gap with MAPEJOINT FB, bituminous impregnated fibre board and filled with MAPEFLEX PU 70 SL/45 FT high
performance PU sealant and MAPEFOAM, backer road (00 mm width x 00mm depth)
Joint Filler Board To fill expansion joint gap with "Mapei" MAPEJOINT FB bituminous impregnated fibre board joint filler (Supply Only)
MAPEJOINT FB 10mm (1.2x2.0m sheet) sheet 57.00
MAPEJOINT FB 12.5mm (1.2x2.0m sheet) sheet 67.00
MAPEJOINT FB 20mm (1.2x2.0m sheet) sheet 112.00
MAPEJOINT FB 25mm (1.2x2.0m sheet) sheet 122.00
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapejoint-fb
https://www.mapei.com/in/en/products-and-solutions/products/detail/mapefoam
https://www.mapei.com/it/en/products-and-solutions/products/detail/mapeflex-pu-45-ft
To supply and fill up joint gap to create unbonded surface with MAPEFLEX PU70 SL, two component PU sealant to form two way
Foam Backing Rod
movement with "Mapei" MAPEFOAM, foam backing rod
Construction joint To supply "Mapei" IDROSTOP PVC CJ PVC waterstop (Supply Only)
PVC Waterstop IDROSTOP CJ15 in 150mm 20M/Roll m 35.00
IDROSTOP CJ20 in 200mm 20M/Roll m 45.00
IDROSTOP CJ25 in 250mm 15M/Roll m 50.00
B FLOOR FINISHES
Flatness Control Burnish Slab with Non Metallic Cementitous Hardener & Curing Compound
EXTRA OVER COST
Extra over cost of casting of concrete (concrete by others) using superflat floor tools & equipment inclusive of setting level guide bar
(Wooden Formwork /Hyrib Mesh by others) to achieve surface flatness of FF30 FL20 as measured in accordance with ASTM-E1155 or
equivalent to ±5mm flatness tolerance over 3m straightedge (Category 2) by using Dipstick Profiler (F-Number System).
Warehouse Mapetop SP & Broadcast approved natural coloured dry shake floor hardener, MAPETOP SP with dosage of 4 kg/sq.m laid monolithically onto fresh
Mapecure SP concrete, mechanically floated and troweled to dense, burnished finish and cure with MAPECURE SP, curing compound. All in accordance
to manufacturer’s specification and instructions.
1 To floor m2 35.00
To diamond saw cut joint as crack inducer with size of 5mm x 20mm deep, install MAPEFOAM backer rod then follow with MAPEFLEX PU
2 m 28 to 30
45 FT joint sealant to seal the above saw cut joint
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapetop-sp
https://www.mapei.com/my/en/products-and-solutions/lines/products/detail/mapecure-sp
IMPORTANT Note: To obtain consistency of the resin floor thickness, the concrete base shall be casted by controling the levelness and
flatness during concreting process. For wet area, substrate shall cast to fall.
Substrate Requirement :
( a ) Power floated concreate without hardener. Suggest to specify floor flatness of SR 2 conditions.
( b ) Surface regularity is defined as the flatness or measure waviness of the screeded surface.
( c ) Compressive stregth of the concrete shall be minimum 25 N/mm2 and pull of strength at least 1.5N/mm2, and shall be allowed for full cured in 28 days.
( d ) The application of Moisture Tolerance System is required for Moisture Content more than 4 % prior any application of any resin floor.
( e ) The concrete floor shall provide movement joints, design spec shall be provided by Engineer.