Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

NFPA

Compliance

In today’s bulk handling systems, nearly all materials are combustible under the right conditions. With the right mixture of fine
particles, oxygen and an ignition source an explosion could happen at any time. It is up to the end user to make sure their
system is safe and compliant with the applicable NFPA standards. Schenck Process reviews each air filtration application
with the customer to select the best explosion mitigation strategy for the application.

Protection Options 
» Explosion venting 


» Ducted venting
» Flameless venting Containment Deflagration Venting Suppression Oxidant Reduction
» Containment
» Inert gas/oxygen reduction

Deflagration Isolation

Example – Flameless Venting Example – Indoor Vessel


Clean-air
exhaust-duct
to outside
Pressure sensor assembly
Isolation valve to detect deflagration in
for clean air its early stage and trigger
return to Passive chemical isolation
building isolation
valve

Flameless
explosion Deflagration
relief panel Cannon on dirty-air
relief vent Rotary airlock
to relieve the inlet-duct to
to isolate prevent deflagration
pressure of a hopper and
deflagration propagation
Rotary airlock to isolate prevent
hopper and prevent deflagration
deflagration propagation propagation
Engineering site surveys

When it comes to helping you meet NFPA compliance ■ Project management


Schenck Process offers dust collection users its on-site ■ Turn-key installation
air filtration surveys. Program participants receive a full ■ Start-up & commissioning
assessment of their current air filtration systems along ■ Recommended spare parts list
with recommendations on improving efficiencies. ■ Evaluate physical conditions of existing filters,
fans and airlocks
Engineering Surveys ■ Evaluate existing ductwork layout and sizing, dust
■ On-site dust collection analysis discharge design and pneumatic transfer system
■ Particle size analysis and emission testing ■ Consult with customer personnel to determine
■ Field measurement of dust producing equipment system rates, equipment functionality, problem
and plant layout areas and desired results from findings
■ Preliminary sketches of plant/equipment layout ■ Provide quotation for new and upgraded solutions
based on this analysis and current recommendation
to include appropriate NFPA compliance Filtration Audit Team
■ Full assessment including 3-D CAD drawings ■ Industrial Ventilation Design Specialists
& CFD modeling ■ 3D CAD Designer
■ NFPA & explosion protection recommendations ■ Application Specialists
■ Energy efficient designs ■ Explosion Protection Experts
■ Filtration test lab to guarantee emission compliance
© by Schenck Process LLC, 2021

Benefits
■ Improve energy efficiencies
■ Reduce the amount of required airflow
Schenck Process ■ Ensure employee health
7901 NW 107th Terrace ■ Manage plant expansion
Kansas City, MO 64153 ■ Meet NFPA compliance
816-891-9300 or Fax: 816-891-8336
E-mail: americas@schenckprocess.com
Web site: www.schenckprocess.com/us